Search NASA⌕ Search

SEARCH · Search NASA

Results for “microvalve”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

High-temperature, adhesive-based microvalves and uses thereof

The present invention relates to adhesive-based microvalves, as well as assemblies and cartridges having such microvalves. In particular examples, substantially planar layers of adhesive materials are used to construct both normally-open and normally-closed microvalves for fluid control within microfluidic laminate cartridges. Such microvalves and cartridges can be useful for medical, chemical, and biological investigations.

42 ENGINEERING↗

Electrokinetic Sample Preconcentration and Hydrodynamic Sample Injection for Microchip Electrophoresis Using a Pneumatic Microvalve

A microfluidic platform was developed to perform online electrokinetic sample preconcentration and rapid hydrodynamic sample injection for electrophoresis using a single microvalve. The PDMS microchip consists of a separation channel, a side channel for sample introduction, and a control channel which is used as a pneumatic microvalve aligned at the intersection of the two flow channels. The closed microvalve, created by multilayer soft lithography, can serve as a preconcentrator under an applied electric potential, enabling current to pass through while blocking bulk flow. Once analytes are concentrated, the valve is briefly opened and the stacked sample is pressure injected into the separation channel for electrophoretic separation. Fluorescently labeled peptides were enriched by a factor of ~450 in 230 s. The performance of the platform was validated by the online preconcentration, injection and electrophoretic separation of fluorescently labeled peptides. This method enables both rapid analyte concentration and controlled injection volume for high sensitivity, high resolution capillary electrophoresis.

capillary↗

Pneumatic Microvalve-Based Hydrodynamic Sample Injection for High-Throughput, Quantitative Zone Electrophoresis in Capillaries

A hybrid microchip/capillary CE system was developed to allow unbiased and lossless sample loading and high throughput repeated injections. This new hybrid CE system consists of a polydimethylsiloxane (PDMS) microchip sample injector featuring a pneumatic microvalve that separates a sample introduction channel from a short sample loading channel and a fused silica capillary separation column that connects seamlessly to the sample loading channel. The sample introduction channel is pressurized such that when the pneumatic microvalve opens briefly, a variable-volume sample plug is introduced into the loading channel. A high voltage for CE separation is continuously applied across the loading channel and the fused silica capillary separation column. Analytes are rapidly separated in the fused silica capillary with high resolution. High sensitivity MS detection after CE separation is accomplished via a sheathless CE/ESI-MS interface. The performance evaluation of the complete CE/ESI-MS platform demonstrated that reproducible sample injection with well controlled sample plug volumes could be achieved by using the PDMS microchip injector. The absence of band broadening from microchip to capillary indicated a minimum dead volume at the junction. The capabilities of the new CE/ESI-MS platform in performing high throughput and quantitative sample analyses were demonstrated by the repeated sample injection without interrupting an ongoing separation and a good linear dependence of the total analyte ion abundance on the sample plug volume using a mixture of peptide standards. The separation efficiency of the new platform was also evaluated systematically at different sample injection times, flow rates and CE separation voltages.

Eletrophoresis↗

End-hole Versus Microvalve Infusion Catheters in Patients Undergoing Drug-Eluting Microspheres-TACE for Solitary Hepatocellular Carcinoma Tumors: A Retrospective Analysis

Introduction: Pre-transplant locoregional therapy for hepatocellular carcinoma (HCC) during bridge-to-transplant impacts recurrence and survival rates following liver transplantation. Optimizing the effectiveness of transarterial chemoembolization (TACE) in this population is imperative, and microvalve infusion catheters offer a means of such improvement. Methods: All treatment-naive patients with solitary HCC tumors < 6.5 cm who underwent drug-eluting microspheres (DEM) TACE between 04/2015 and 08/2017 were retrospectively reviewed. Eighty-eight included patients underwent DEM-TACE with either standard end-hole catheters (EH) or microvalve infusion catheters (MVI). The EH (n = 70) and MVI (n = 18) cohorts had similar baseline tumor size, laboratory values, and tumor etiologies. Results: Initial objective response rates were significantly higher in MVI vs. EH (100% vs. 76.5%, p = 0.019). There was no difference in adverse events between groups (p = 0.265). MVI patients exhibited lower AST (p = 0.003) and ALT (p = 0.044) at 6 months. Blinded pathological analysis of explanted livers showed greater concentrations of microspheres within the tumor relative to the surrounding tissue in MVI explants (88.7 ± 10.6%) versus the EH explants (55.3 ± 32.7%) (p = 0.002). There was significantly higher percentage tumor necrosis in the MVI group (89.0 ± 2.2%) compared with the EH group (56.1 ± 44.5%) (p = 0.006). Conclusion: In this retrospective study of a single-center cohort, DEM-TACE procedures with MVI were associated with improved tumor response, increased deposition of microspheres within tumor tissue, and higher percentage tumor necrosis at explant relative to those performed using EH catheters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PNEUMATIC MICROVALVE FOR ELECTROKINETIC SAMPLE PRECONCENTRATION AND CAPILLARY ELECTROPHORESIS INJECTION

Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefly opened and the sample is hydrodynamically injected onto an integrated microchip or capillary electrophoresis (CE) column. In contrast to existing preconcentration approaches, the membrane-based method described here enables both rapid analyte concentration as well as high resolution separations.

Environmental Molecular Sciences Laboratory↗

Novel volumetric method for highly repeatable injection in microchip electrophoresis

A novel injector for microchip electrophoresis (MCE) has been designed and evaluated that achieves very high repeatability of injection volume suitable for quantitative analysis. It eliminates the injection biases in electrokinetic injection and the dependence on pressure and sample properties in hydrodynamic injection. The microfluidic injector, made of poly(dimethylsiloxane) (PDMS), operates similarly to an HPLC injection valve. It contains a channel segment (chamber) with a well-defined volume that serves as an “injection loop”. Using on-chip microvalves, the chamber can be connected to the sample source during the “loading” step, and to the CE separation channel during the “injection” step. Once the valves are opened in the second state, electrophoretic potential is applied to separate the sample. For evaluation and demonstration purposes, the microinjector was connected to a 75 μm ID capillary and UV absorbance detector. For single compounds, a relative standard deviation (RSD) of peak area as low as 1.04% (n = 11) was obtained, and for compound mixtures, RSD as low as 0.40% (n = 4) was observed. Using the same microchip, the performance of this new injection technique was compared to hydrodynamic injection and found to have improved repeatability and less dependence on sample viscosity. Furthermore, a non-radioactive version of the positron-emission tomography (PET) imaging probe, FLT, was successfully separated from its known 3 structurally-similar byproducts with baseline resolution, demonstrating the potential for rapid, quantitative analysis of impurities to ensure the safety of batches of short-lived radiotracers. Both the separation efficiency and injection repeatability were found to be substantially higher when using the novel volumetric injection approach compared to electrokinetic injection (performed in the same chip). This novel microinjector provides a straightforward way to improve the performance of hydrodynamic injection and enables extremely repeatable sample volume injection in MCE. It could be used in any MCE application where volume repeatability is needed, including the quantitation of impurities in pharmaceutical or radiopharmaceutical samples.

60 APPLIED LIFE SCIENCES↗

Bidirectional shape memory device

A resistively heated shape memory polymer device is operated using resistive heating to heat the shape memory polymer device. The resistively heated shape memory polymer device is made by providing a wire that includes a resistive medium. The wire is coated with a first shape memory polymer. The wire is exposed and electrical leads are attached to the wire. In one embodiment the shape memory polymer device is in the form of a clot destruction device. In another embodiment the shape memory polymer device is in the form of a microvalve. In another embodiment the shape memory polymer device is in the form of a micropump. In yet another embodiment the shape memory polymer device is in the form of a thermostat or relay switch.

36 MATERIALS SCIENCE↗

Bidirectional shape memory device

A resistively heated shape memory polymer device is operated using resistive heating to heat the shape memory polymer device. The resistively heated shape memory polymer device is made by providing a wire that includes a resistive medium. The wire is coated with a first shape memory polymer. The wire is exposed and electrical leads are attached to the wire. In one embodiment the shape memory polymer device is in the form of a clot destruction device. In another embodiment the shape memory polymer device is in the form of a microvalve. In another embodiment the shape memory polymer device is in the form of a micropump. In yet another embodiment the shape memory polymer device is in the form of a thermostat or relay switch.

Marion, III, John E.↗