Search NASA⌕ Search

SEARCH · Search NASA

Results for “microwave imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Accurate surface estimation from high-resolution 3D microwave images

Active millimeter and microwave imaging techniques can be used to create a high-resolution 3D image volume of a target’s reflectivity. Millimeter-wave imaging is commonly used for personnel security screening and numerous other applications. Backprojection based image reconstruction techniques form a 3D complex-valued volume. The complex-valued volume is commonly reduced to a real-valued volume by taking the magnitude. For anomaly detection and cross image registration of an object it is beneficial to generate an accurate representation of an object’s surface. Extracting a smooth and accurate surface from a magnitude only image is challenging. One difficulty is the magnitude image has limited resolution in the depth direction which normally limits precision to a moderate fraction of the depth resolution. Another difficulty is that the magnitude of the image depends heavily on the geometry and orientation of the object being imaged. The phase information in a complex-valued image volume provides a means to decouple the magnitude of the image from the geometry of an object and provide precision much finer than the depth resolution would indicate. This enables the generation of a smooth and accurate point cloud representation of the surface of an imaged object. A method to extract a point cloud from the phase information in a 3D complex-valued millimeter-wave image volume is developed and results with simulated and experimental data are presented.

Clark, Richard T.↗

The co-located arrangement of ECEI and MIR microwave imaging diagnostics on EAST tokamak

The co-located configuration of Passive Electron Cyclotron Emission Imaging (ECEI) and active Microwave Imaging Reflectometry (MIR) diagnostics systems has been successfully implemented on the EAST fusion reactor. These advanced 2D microwave diagnostic tools offer 10–20 mm poloidal spatial resolution through large aperture quasi optics. This arrangement not only optimizes the utilization of limited observation windows but also facilitates concurrent measurements of plasma density and electron temperature at specific toroidal positions. Furthermore, this co-located setup holds great promise for enhancing research into electron heat transport and other pivotal plasma phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microwave Imaging of Edge Conductivity in Graphene at Charge Neutrality and Quantum Hall States

Here, we report local conductivity imaging of edge states in monolayer graphene by millikelvin microwave impedance microscopy. At the charge-neutrality point, as the magnetic field increases, the local conductivity at the edge drops to zero more slowly than in the bulk. This behavior is consistent with the calculated spatial profile of the charge gap in the canted antiferromagnetic phase. For comparison, we also perform microwave imaging of integer quantum Hall states away from neutrality, which host dissipationless chiral edge channels. The evolution of the edge signal as a function of the bulk gap is fundamentally different between the Landau level filling factor 𝜈 = 0 and |𝜈| ≥ 1 integer quantum Hall states, which can be qualitatively explained by numerical simulations and theoretical analysis. Our results provide a comprehensive microscopic picture of the edge and bulk states as the Fermi level moves across the unique Landau-level spectrum of graphene.

Hall effect↗

Unveiling defect-mediated carrier dynamics in monolayer semiconductors by spatiotemporal microwave imaging

The optoelectronic properties of atomically thin transition-metal dichalcogenides are strongly correlated with the presence of defects in the materials, which are not necessarily detrimental for certain applications. For instance, defects can lead to an enhanced photoconduction, a complicated process involving charge generation and recombination in the time domain and carrier transport in the spatial domain. Here, we report the simultaneous spatial and temporal photoconductivity imaging in two types of WS 2 monolayers by laser-illuminated microwave impedance microscopy. The diffusion length and carrier lifetime were directly extracted from the spatial profile and temporal relaxation of microwave signals, respectively. Time-resolved experiments indicate that the critical process for photoexcited carriers is the escape of holes from trap states, which prolongs the apparent lifetime of mobile electrons in the conduction band. As a result, counterintuitively, the long-lived photoconductivity signal is higher in chemical-vapor deposited (CVD) samples than exfoliated monolayers due to the presence of traps that inhibits recombination. Overall, our work reveals the intrinsic time and length scales of electrical response to photoexcitation in van der Waals materials, which is essential for their applications in optoelectronic devices.

42 ENGINEERING↗

Ultra-Wideband Microwave Imaging System for Root Phenotyping

The roots are a vital organ for plant growth and health. The opaque surrounding environment of the roots and the complicated growth process means that in situ and non-destructive root phenotyping face great challenges, which thus spur great research interests. The existing methods for root phenotyping are either unable to provide high-precision and high accuracy in situ detection, or they change the surrounding root environment and are destructive to root growth and health. Thus,we propose and develop an ultra-wideband microwave scanning method that uses time reversal to achieve in situ root phenotyping nondestructively. To verify the method’s feasibility, we studied an electromagnetic numerical model that simulates the transmission signal of two ultra-wideband microwave antennas. The simulated signal of roots with different shapes shows the proposed system’s capability to measure the root size in the soil. Experimental validations were conducted considering three sets of measurements with different sizes, numbers and locations, and the experimental results indicate that the developed imaging system was able to differentiate root sizes and numbers with high contrast. The reconstruction from both simulations and experimental measurements provided accurate size estimation of the carrots in the soil, which indicates the system’s potential for root imaging.

59 BASIC BIOLOGICAL SCIENCES↗

Flux Channeling Induced Nanoconfinement and Enhancement of Microwaves Imaged by Rabi Oscillation Mapping

With rapid advances in qubit technologies, techniques for localizing, modulating, and measuring RF fields and their impact on qubit performance are of the utmost importance. Here, we demonstrate that flux-channeling from a permalloy nanowire can be used to achieve localized spatial modulation of an RF field and that the modulated field can be mapped with high resolution by using the Rabi oscillations of an NV center. Rabi maps reveal ∼100 mm wavelength microwaves concentrated in sub-300 nm regions with up to ∼16× power enhancement. This modulation is robust over a 20 dBm power range and has no adverse impact on NV T 2 coherence time. Micromagnetic simulations confirm that the modulated field results from the nanowire’s stray field through its constructive/destructive interference with the incident RF field. Our findings provide a new pathway for controlling qubits, amplifying RF signals, and mapping local fields in various on-chip RF technologies.

Diamond↗

System-on-chip approach microwave imaging reflectometer on DIII-D tokamak

System-on-chip millimeter wave integrated circuit technology is used on the two-dimensional millimeter-wave imaging reflectometer (MIR) upgrade for density fluctuation imaging on the DIII-D tokamak fusion plasma. Customized CMOS chips have been successfully developed for the transmitter module and receiver module array, covering the 55–75 GHz working band. The transmitter module has the capability of simultaneously launching eight tunable probe frequencies (>0 dBm output power each). The receiver enclosure contains 12 receiver modules in two vertical lines. The quasi-optical local oscillator coupling of previous MIR systems has been replaced with an internal active frequency multiplier chain for improved local oscillator power delivery and flexible installation in a narrow space together with improved shielding against electromagnetic interference. The 55–75 GHz low noise amplifier, used between the receiver antenna and the first-stage mixer, significantly improves module sensitivity and suppresses electronics noise. The receiver module has a 20 dB gain improvement compared with the mini-lens approach and better than –75 dBm sensitivity, and its electronics noise temperature has been reduced from 55 000 K down to 11 200 K. Further, the V-band MIR system is developed for co-located multi-field investigation of MHD-scale fluctuations in the pedestal region with W-band electron cyclotron emission imaging on DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Millimeter-Wave Imaging Technology Development for Real-Time 2D and 3D Fusion Plasma Diagnostics

Including a one year No-Cost Extension, The University of California, Davis has been funded since 2020 to advance innovative millimeter-wave diagnostics for fusion plasma research. This work includes: (1) Developing and applying cutting-edge System-on-Chip millimeter wave Integrated Circuit (IC) technology for Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometry (MIR) on the DIII-D tokamak and the NSTX-U spherical tokamak. (2) Development of radiation-hardened millimeter-wave chip for diagnostics in harsh environments, utilizing wide bandgap Gallium Nitride (GaN) semiconductors. (3) Integrating forward-modeling synthetic diagnostics to enable advanced, real-time plasma prediction and feedback control. Originally planned as a three-year program (2020–2023), the project was granted a one-year no-cost extension, extending its duration through the end of 2024.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects↗

System-on-chip integrated circuit technology applications on the DIII-D tokamak for multi-field measurements

Several mm-wave diagnostics on the DIII-D tokamak provide multi-scale and multi-dimensional measurements of plasma profile evolution and turbulence fluctuations. Mm-wave fusion plasma diagnostics that adopt system-on-chip integrated circuit technology can provide better space utilization, flexible installation, and improved sensitivity. In order to further extend this technology for additional fusion facilities with a higher toroidal magnetic field, V-band (55–75 GHz) and F-band (90–140 GHz) chips for Microwave Imaging Reflectometer (MIR) and Electron Cyclotron Emission Imaging (ECEI) instruments are developed and tested in the Davis Millimeter Wave Research Center (DMRC). Current measurement data show that correlation between these SoC-based diagnostic instruments with other state-of-the-art diagnostics enables co-located multi-field turbulence fluctuation measurement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A global daily soil moisture dataset derived from Chinese FengYun Microwave Radiation Imager (MWRI)(2010–2019)

Surface soil moisture (SSM) is an important variable in drought monitoring, floods predicting, weather forecasting, etc. and plays a critical role in water and heat exchanges between land and atmosphere. SSM products from L-band observations, such as the Soil Moisture Active Passive (SMAP) Mission, have proven to be optimal global estimations. Although X-band has a lower sensitivity to soil moisture than that of L-band, Chinese FengYun-3 series satellites (FY-3A/B/C/D) have provided sustainable and daily multiple SSM products from X-band since 2008. This research developed a new global SSM product (NNsm-FY) from FY-3B MWRI from 2010 to 2019, transferred high accuracy of SMAP L-band to FY-3B X-band. The NNsm-FY shows good agreement with in-situ observations and SMAP product and has a higher accuracy than that of official FY-3B product. With this new dataset, Chinese FY-3 satellites may play a larger role and provide opportunities of sustainable and longer-term soil moisture data record for hydrological study.

54 ENVIRONMENTAL SCIENCES↗

A Parameterization of the Cloud Scattering Polarization Signal Derived From GPM Observations for Microwave Fast Radative Transfer Models

Microwave cloud polarized observations have shown the potential to improve precipitation retrievals since they are linked to the orientation and shape of ice habits. Stratiform clouds show larger brightness temperature (TB) polarization differences (PDs), defined as the vertically polarized TB (TBV) minus the horizontally polarized TB (TBH), with ~10 K PD values at 89 GHz due to the presence of horizontally aligned snowflakes, while convective regions show smaller PD signals, as graupel and/or hail in the updraft tend to become randomly oriented. The launch of the global precipitation measurement (GPM) microwave imager (GMI) has extended the availability of microwave polarized observations to higher frequencies (166 GHz) in the tropics and midlatitudes, previously only available up to 89 GHz. This study analyzes one year of GMI observations to explore further the previously reported stable relationship between the PD and the observed TBs at 89 and 166 GHz, respectively. The latitudinal and seasonal variability is analyzed to propose a cloud scattering polarization parameterization of the PD-TB relationship, capable of reconstructing the PD signal from simulated TBs. Given that operational radiative transfer (RT) models do not currently simulate the cloud polarized signals, this is an alternative and simple solution to exploit the large number of cloud polarized observations available. Finally, the atmospheric radiative transfer simulator (ARTS) is coupled with the weather research and forecasting (WRF) model, in order to apply the proposed parameterization to the RT simulated TBs and hence infer the corresponding PD values, which show to reproduce the observed GMI PDs well.

54 ENVIRONMENTAL SCIENCES↗

Microwave Microscopy and Its Applications

Understanding the nanoscale electrodynamic properties of a material at microwave frequencies is of great interest for materials science, condensed matter physics, device engineering, and biology. With specialized probes, sensitive detection electronics, and improved scanning platforms, microwave microscopy has become an important tool for cutting-edge materials research in the past decade. In this article, we review the basic components and data interpretation of microwave imaging and its broad range of applications. In addition to the general-purpose mapping of permittivity and conductivity, microwave microscopy is now exploited to perform quantitative measurements on semiconductor devices, photosensitive materials, ferroelectric domains and domain walls, and acoustic-wave systems. Implementation of the technique in low-temperature and high-magnetic-field chambers has also led to major discoveries in quantum materials with strong correlation and topological order. We conclude the review with an outlook of the ultimate resolution, operation frequency, and future industrial and academic applications of near-field microwave microscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Negative Index Metamaterial Lens for Subwavelength Microwave Detection

Metamaterials are engineered periodic structures designed to have unique properties not encountered in naturally occurring materials. One such unusual property of metamaterials is the ability to exhibit negative refractive index over a prescribed range of frequencies. A lens made of negative refractive index metamaterials can achieve resolution beyond the diffraction limit. This paper presents the design of a metamaterial lens and its use in far-field microwave imaging for subwavelength defect detection in nondestructive evaluation (NDE). Theoretical formulation and numerical studies of the metamaterial lens design are presented followed by experimental demonstration and characterization of metamaterial behavior. Finally, a microwave homodyne receiver-based system is used in conjunction with the metamaterial lens to develop a far-field microwave NDE sensor system. A subwavelength focal spot of size 0.82λ was obtained. The system is shown to be sensitive to a defect of size 0.17λ × 0.06λ in a Teflon sample. Consecutive positions of the defect with a separation of 0.23λ was resolvable using the proposed system.

47 OTHER INSTRUMENTATION↗

Multiscale and multidimensional modeling of particle acceleration and transport in solar flares

Multi-messenger, multi-viewpoint, and time-resolved observations of solar flares are now providing unprecedented constraints on particle acceleration sites, energy conversion, and energy transport. The interpretation of current observations, including microwave imaging spectroscopy from EOVSA, hard x-ray (HXR) imaging from Solar Orbiter/STIX, gamma-ray diagnostics from Fermi, and in situ measurements from Parker Solar Probe and Solar Orbiter, collectively demands modeling frameworks that go beyond traditional spatially unresolved, one-zone models or single-mechanism descriptions. This review surveys multiscale and multidimensional modeling approaches, including kinetic, magnetohydrodynamic (MHD), and macroscopic particle models, that are being developed to meet the need. Kinetic simulations reveal that three-dimensional (3D) effects, including field-line chaos and self-generated turbulence, are essential for sustained power-law particle acceleration. MHD simulations now capture flux-rope eruptions, plasmoid-unstable current sheets, and turbulent flare regions in realistic magnetic topologies. Macroscopic models coupling MHD with energetic-particle models produce spatially resolved electron distributions and synthetic HXR and microwave emissions for direct comparison with observations. Despite these advances, outstanding challenges remain in bridging kinetic and global scales, improving MHD simulations and macroscopic particle models, and achieving quantitative model-observation closure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Frontier system-on-chip (SoC) technology for microwave diagnostics (invited)

The next generation of fusion reactors, exemplified by projects such as the Demonstration Power Plant following the International Thermonuclear Experimental Reactor, faces the monumental challenge of proving the viability of generating electricity through thermonuclear fusion. This pursuit introduces heightened complexities in diagnostic methodologies, particularly in microwave-based diagnostics. The increased neutron fluence necessitates significant reductions in vessel penetrations and the elimination of internal diagnostics, posing substantial challenges. SoC technology offers a promising solution by enabling the miniaturization, modularization, integration, and enhancing the reliability of microwave systems. After seven years of research, our team successfully pioneered the V- and W-band system-on-chip approach, leading to the development of active transmitters and passive receiver modules applied in practical settings, notably within the DIII-D tokamak project. Arrays of these modules have supported microwave imaging diagnostics. New physics measurement results from the Electron Cyclotron Emission Imaging system on DIII-D provide compelling evidence of improved diagnostics following the adoption of SoC technology. Furthermore, we achieved a breakthrough in developing an F-band SoC, advancing higher frequency capabilities for fusion devices. These achievements represent a significant leap forward in fusion diagnostic technology, marking substantial progress toward establishing reliable and efficient plasma diagnostics for future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrating LEO and GEO Observations: Toward Optimal Summertime Satellite Precipitation Retrieval

Abstract Reliable quantitative precipitation estimation with a rich spatiotemporal resolution is vital for understanding the Earth’s hydrological cycle. Precipitation estimation over land and coastal regions is necessary for addressing the high degree of spatial heterogeneity of water availability and demand, and for resolving the extremes that modulate and amplify hazards such as flooding and landslides. Advancements in computation power along with unique high spatiotemporal and spectral resolution data streams from passive meteorological sensors aboard geosynchronous Earth-orbiting (GEO) and low Earth-orbiting (LEO) satellites offer exciting opportunities to retrieve information about surface precipitation phenomena using data-driven machine learning techniques. In this study, the capabilities of U-Net–like architecture are investigated to map instantaneous, summertime surface precipitation intensity at the spatial resolution of 2 km. The calibrated brightness temperature products from the Global Precipitation Measurement (GPM) Microwave Imager (GMI) radiometer are combined with multispectral images (visible, near-infrared, and infrared bands) from the Advanced Baseline Imager (ABI) aboard the GOES-R satellites as main inputs to the U-Net–like precipitation algorithm. Total precipitable water and 2-m temperature from the Global Forecast System (GFS) model are also used as auxiliary inputs to the model. The results show that the U-Net–like algorithm can capture fine-scale patterns and intensity of surface precipitation at high spatial resolution over stratiform and convective precipitation regimes. The evaluations reveal the potential of extracting relevant, high spatial features over complex surface types such as mountainous regions and coastlines. The algorithm allows users to interpret the inputs’ importance and can serve as a starting point for further exploration of precipitation systems within the field of hydrometeorology.

Meteorology & Atmospheric Sciences↗

System-on-Chip approach microwave diagnostics development for burning plasma

System-on-chip (SoC) millimeter wave integrated circuit technology has been developed and employed in chip heterodyne radiometers in Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometer (MIR) on the DIII-D tokamak for 2D electron temperature and density fluctuation diagnostics. The W-band (75-110 GHz) ECEI system has been employed with 20 poloidal horn receiver modules with customized monolithic integrated circuit chips and internal local oscillator coupling path. The new SoC approach demonstrates > 30 dB additional gain on the receiver and 95% electronics noise suppression compared to the previous Schottky diode mixer array . An F-band (110-140 GHz) receiver chip has been developed to measure MHD and turbulence behavior on the DIII-D high-field side, such as Alfven eigenmodes. Furthermore, it can image pedestal structure evolution on fusion facilities with stronger magnetic fields, such as ASDEX-U, EAST, HL-2M, and LHD. The F-band chip performance has been tested in the laboratory. Also, V-band (55-75 GHz) transmitter and receiver modules (55-75 GHz) have been developed for DIII-D and NSTX-U Furthermore, microwave Imaging Reflectometer (MIR) application suitability for 2D density fluctuation imaging on the pedestal region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗