Search NASA⌕ Search

SEARCH · Search NASA

Results for “microwave techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Strain-tunable microwave-resonance technique for quantum materials

By integrating a dielectric microwave resonator with a piezoelectric-based strain device, we develop an in situ strain-tunable microwave spectroscopy technique that enables contactless measurements of material properties under strain. To demonstrate the capability of this device, we measure the strain-dependent microwave surface impedance of the representative iron-based superconductor Ba⁢Fe 2 (As 1−𝑥 ⁢P 𝑥 ) 2 at the slightly overdoped composition. We successfully control and observe the suppression of superconductivity under both compressive and tensile anisotropic lattice distortions along the tetragonal [110] T direction, as manifested by changes in the quality factor and resonance frequency shifts of microwave resonance. Furthermore, strain-induced changes in microwave surface resistivity, an extension of conventional DC-limit transport elastoresistivity to the microwave regime, provide information on electronic anisotropy equivalent to that of DC elastoresistivity, while offering a contactless alternative. Furthermore, our strain-tunable cavity therefore serves as a powerful, contactless probe of fundamental material properties under strain and may also potentially facilitate the design of hybrid quantum systems with strain-engineered quantum degrees of freedom.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Circuit quantum electrodynamics detection of induced two-fold anisotropic pairing in a hybrid superconductor–ferromagnet bilayer

Abstract Hybrid systems represent one of the frontiers in the study of unconventional superconductivity and are a promising platform to realize topological superconducting states. These materials are challenging to probe using many conventional measurement techniques because of their mesoscopic dimensions, and therefore require new experimental probes so that they can be successfully characterized. Here, we demonstrate a probe that enables us to measure the superfluid density of micrometre-size superconductors using microwave techniques drawn from circuit quantum electrodynamics. We apply this technique to a superconductor–ferromagnet bilayer and find that the proximity-induced superfluid density is two-fold anisotropic within the plane of the sample. It also exhibits power-law temperature scaling that is indicative of a nodal superconducting state. These experimental results are consistent with the theoretically predicted signatures of induced triplet pairing with a nodal p -wave order parameter. Moreover, we observe modifications to the microwave response at frequencies near the ferromagnetic resonance, suggesting a coupling between the spin dynamics and induced superconducting order in the ferromagnetic layer. Our experimental technique can be employed more widely, for example to study fragile unconventional superconductivity in low-dimensional materials such as van der Waals heterostructures.

Bøttcher, C. G. L. (ORCID:0000000194898461)↗

Field programmable spin arrays for scalable quantum repeaters

The large scale control over thousands of quantum emitters desired by quantum network technology is limited by the power consumption and cross-talk inherent in current microwave techniques. Here we propose a quantum repeater architecture based on densely-packed diamond color centers (CCs) in a programmable electrode array, with quantum gates driven by electric or strain fields. This ‘field programmable spin array’ (FPSA) enables high-speed spin control of individual CCs with low cross-talk and power dissipation. Integrated in a slow-light waveguide for efficient optical coupling, the FPSA serves as a quantum interface for optically-mediated entanglement. We evaluate the performance of the FPSA architecture in comparison to a routing-tree design and show an increased entanglement generation rate scaling into the thousand-qubit regime. Our results enable high fidelity control of dense quantum emitter arrays for scalable networking.

42 ENGINEERING↗

Transmon qubit readout fidelity at the threshold for quantum error correction without a quantum-limited amplifier

Abstract High-fidelity and rapid readout of a qubit state is key to quantum computing and communication, and it is a prerequisite for quantum error correction. We present a readout scheme for superconducting qubits that combines two microwave techniques: applying a shelving technique to the qubit that reduces the contribution of decay error during readout, and a two-tone excitation of the readout resonator to distinguish among qubit populations in higher energy levels. Using a machine-learning algorithm to post-process the two-tone measurement results further improves the qubit-state assignment fidelity. We perform single-shot frequency-multiplexed qubit readout, with a 140 ns readout time, and demonstrate 99.5% assignment fidelity for two-state readout and 96.9% for three-state readout–without using a quantum-limited amplifier.

Chen, Liangyu (ORCID:0000000250722445)↗

Quantum Sensed Electron Spin Resonance Discovery Platform (Final Report)

The properties of materials can change dramatically at the nanoscale new and useful properties can emerge. An example is found in the paramagnetism in iron oxide magnetic nanoparticles. Using magnetically sensitive nitrogen-vacancy centers in diamond, we developed a platform to study electron spin resonance of nanoscale materials. To implement the platform, diamond substrates were prepared with nitrogen vacancy centers near the surface. Nanoparticles were placed on the surface using a drop casting technique. Using optical and microwave pulsing techniques, we demonstrated T1 relaxometry and double electron-electron resonance techniques for measuring the local electron spin resonance. The diamond NV platform developed in this project provides a combination of good magnetic field sensitivity and high spatial resolution and will be used for future investigations of nanomaterials and quantum materials.

36 MATERIALS SCIENCE↗

Improved receiver noise calibration for ADMX axion search: 4.54 to 5.41 μeV

Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Because of the weak coupling of axions to photons, however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra-low-noise electronics. In this paper, we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280 MHz taken during ADMX’s most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and Josephson Parametric Amplifier as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX

Axion dark matter can satisfy the conditions needed to account for all of the dark matter and solve the strong 𝐶⁢𝑃 problem. The Axion Dark Matter eXperiment (ADMX) is a direct dark matter search using a haloscope to convert axions to photons in an external magnetic field. Key to this conversion is the use of a microwave resonator that enhances the sensitivity at the frequency of interest. The ADMX experiment boosts its sensitivity using a dilution refrigerator and near quantum-limited amplifier to reduce the noise level in the experimental apparatus. In the most recent run, ADMX searched for axions between 1.10 and 1.31 GHz to extended Kim-Shifman-Vainshtein-Zakharov sensitivity. This Letter reports on the results of that run, as well as unique aspects of this experimental setup.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

N - V –Diamond Magnetic Microscopy Using a Double Quantum 4-Ramsey Protocol

We introduce a double quantum (DQ) 4-Ramsey measurement protocol that enables wide-field magnetic imaging using nitrogen-vacancy (N-V) centers in diamond, with enhanced homogeneity of the magnetic sensitivity relative to conventional single quantum (SQ) techniques. The DQ 4-Ramsey protocol employs microwave-phase alternation across four consecutive Ramsey (4-Ramsey) measurements to isolate the desired DQ magnetic signal from any residual SQ signal induced by microwave pulse errors. In a demonstration experiment employing a 1-μm-thick N-V layer in a macroscopic diamond chip, the DQ 4-Ramsey protocol provides a volume-normalized dc magnetic sensitivity of η V = 34nTHz –1/2 μm 3/2 across a 125 μm × 125 μm field of view, with about 5× less spatial variation in sensitivity across the field of view compared to a SQ measurement. Furthermore, the improved robustness and magnetic sensitivity homogeneity of the DQ 4-Ramsey protocol enables imaging of dynamic broadband magnetic sources such as integrated circuits and electrically active cells.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Circularly Polarized Light-Induced Microwave Conductivity Measurement: Rapid Screening Technique of Electronic Conductivity in Chiral Molecular Materials

Here, we developed circularly polarized light-time-resolved microwave conductivity (CPL-TRMC) for investigation of the CPL-dependent photoinduced charge carrier dynamics in chiral materials with chiroptical properties. Chiral R- or S-perylenediimide (PDI) molecular thin films were paired with handedness-sorted (6,5) and (11,-5) single-walled carbon nanotube (SWCNT) films to compose a donor (D)-acceptor (A) system for the spin-dependent charge separation process, and the D-A system was examined through linear and circular polarization-dependent steady-state and time-resolved measurements. The R-PDI-(6,5) film exhibited strong enhancement in circular dichroism (CD) and revealed a reversed transient conductivity signal, relative to the polarity of CD in CPL-TRMC measurement upon excitation of the E 11 state, which is interpreted as arising from a spin-dependent initial charge separation process. Through linear polarization-dependent flash photolysis TRMC and circular polarization-resolved femtosecond transient absorption, we could deduce that sub-picosecond intertubular charge separation upon E 11 excitation in SWCNT was responsible for the spin-dependent photoconductivity transients observed in CPL-TRMC measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microwave-Mediated Extraction of Critical Metals from LED E-Waste

This study introduces a microwave-assisted technique for extracting critical minerals from LED electronic waste. The process begins with microwave irradiation, which thermally decomposes the LED’s plastic lens into a brittle, charred residue. During this stage, the LED chip undergoes deflagration—being rapidly ejected from the reflective cavity and becoming embedded within the decomposed lens material. Consequently, the chip is encapsulated in the resulting charred residue. This composite, consisting of the charred lens and the LED chip, can be easily separated from the metallic pins (Fe, Ni, Ag), which remain almost undamaged. Subsequent calcination of the charred material in air exposes the materials making up the LED chip, which contain critical metals (e.g., Ga, As, In, Y, Au). These metals are then extracted through a two-step acid leaching process involving aqua regia followed by hot concentrated hydrochloric acid, yielding them in potentially recoverable forms. The synergistic effect of microwave irradiation and acid treatment achieves an average extraction efficiency of 96% for critical metals. Notably, this approach enables complete and loss-free recovery of the LED chip, offering a practical and efficient solution for LED e-waste recycling.

Bourlinos, Athanasios B.↗

Characterization of Nb films with varying RRR values at low temperatures [Poster]

Superconducting properties of Nb in microwave fields vary significantly with lattice defects and impurity content, where sub-at.% impurity level can reduce or increase microwave surface resistance by an order of magnitude. In this study, we studied the microwave properties of Nb films, deposited by different PVD techniques, at low microwave fields correlating microwave properties at dilution fridge temperatures with material properties characterized with surface science techniques. We are studying the microwave properties of Nb films, deposited by different PVD techniques, at low microwave fields and low temperatures. The first Nb film, deposited onto an elliptical niobium cavity by HiPIMS technique at CERN, was tested at low temperatures. The first results show that film performance was similar to that of the bulk niobium cavities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rapid and Energy‐Efficient Synthesis of Disordered Rocksalt Cathodes

Abstract Lithium‐rich transition metal oxides with a cation‐disordered rocksalt structure (disordered rocksalt oxides or DRX) are promising candidates for sustainable, next‐generation Li‐ion cathodes due to their high energy densities and compositional flexibility, enabling Co‐ and Ni‐free battery chemistries. However, current methods to synthesize DRX compounds require either high temperature (≈1000 °C) sintering for several hours, or high energy ball milling for several days in an inert atmosphere. Both methods are time‐ and energy‐intensive, limiting the scale up of DRX production. The present study reports the rapid synthesis of various DRX compositions in ambient air via a microwave‐assisted solid‐state technique resulting in reaction times as short as 5 min, which are more than two orders of magnitude faster than current synthesis methods. The DRX compounds synthesized via microwave are phase‐pure and have a similar short‐ and long‐range structure as compared to DRX materials synthesized via a standard solid‐state route, resulting in nearly identical electrochemical performance. In some cases, microwave heating allows for better particle size and morphology control. Overall, the rapid and energy‐efficient microwave technique provides a more sustainable route to produce DRX materials, further incentivizes the development of next‐generation DRX cathodes, and is key to accelerating their optimization via high‐throughput studies.

25 ENERGY STORAGE↗

Thin-Entrance Window Process for Soft X-Ray Sensors

New free electron lasers, such as SLAC’s LCLS-II, will provide unique scientific imaging opportunities. In order to fully utilize these facilities, we need to develop detectors with shallow entrance windows that will enable detection of soft x-rays from 250 eV to 1.5 KeV. Achieving adequately shallow entrance windows is challenging because the high temperature anneal needed to activate the dopant also drives the dopant profile deeper, growing the region that is insensitive to soft x-rays. A new microwave annealing technology provides an efficient way to achieve shallow entrance windows in fully depleted high-resistivity silicon sensors. The microwave anneal technique can activate dopants at low substrate temperature, with minimal dopant diffusion, and can be used to fabricate both n-type and p-type entrance windows. SRP and SIMS measurements were used to verify dopant activation with negligible dopant diffusion. We then applied the microwave anneal process to a planar sensor wafer, using the new process to create the backside diode contact. Electrical test of the resulting sensors shows good reverse bias characteristics. The sensors have been bump-bonded to a read-out ASIC and used successfully to measure an Fe-55 x-ray spectrum. Process and device simulations were performed to characterize the quantum efficiency of the entrance window for soft x-rays. This technique is useful for other sensor applications requiring a shallow entrance window, including detectors for UV photons, low energy ions and low energy electrons.

47 OTHER INSTRUMENTATION↗

Core-Shell Oxidative Aromatization Catalysts for Single Step Liquefaction of Distributed Shale Gas (Final Technical Report)

The objective of this project was to design and demonstrate a core-shell structured multifunctional catalyst to convert the light (dry) components of shale gas into liquid aromatic compounds (primarily benzene and toluene) in a single step. Operated in a modular oxidative aromatization system (OAS) under a cyclic redox scheme, the novel catalyst and process can significantly improve the value and transportability of distributed shale gas. Since the project started, each quarter addressed a different set of tasks related to the completion of the milestone detailed in the project award. The yearly summaries of these tasks are summarized below: Q1-Q4: • Conducted project planning and literature search. • Investigated a number of SHC redox catalysts using thermogravimetric analysis and fixed-bed reactor experiments. • Initiated process modeling towards generating two process models for the methane DHA base case and OAS process. • Developed DHA catalysts capable of producing >500 g/kg-cat-hr aromatics at 80% or greater aromatics selectivity at 700°C. Q5-Q8: • Developed alternative approaches with sequential bed configurations to enhance the aromatic yields based on OCM+DHA • Improved the zeolite synthesis efficiency by using the microwave-assisted technique and investigated the synthesis conditions on the zeolite yield, crystalline structure and morphology • Constructed a set of Aspen Plus process models with significant energy savings for OAS as compared to the base case non-oxidative DHA. • Adapted conventional hydrothermal method to be applicable to the microwave synthesizer unit for more efficient catalyst synthesis. • Studied the structure of the OCM catalyst and the dispersion of the carbonate in the redox reactions and in methane flow with Raman Spectroscopy. Q9-Q12: • Scaled up the catalyst synthesis with the microwave synthesis method. Based on its performance, procedural characterizations and catalytic performance testing were further conducted for the new microwave synthesized catalysts with the newly-developed product analysis procedure. • Developed the reaction system setup for the C2-DHA or OCM+DHA reaction product and achieved a better product collection-analysis method for the aromatic products with an improved carbon balance. The product from the OCM reaction exhibited complicated effects on the DHA catalyst. • Conducted additional OCM catalyst characterization using Near Ambient Pressure X-ray Photoelectron Spectroscopy and in situ Raman characterization • Validated the significant energy savings for OAS as compared to the base case non-oxidative DHA. Successfully set up the simulation model for the OCM+DHA+SHC reaction system based on the updated experimental results from NCSU. Q13-End of project: • Synthesized new zeolite catalysts by the microwave method, conducted characterizations (XRD, SEM, and TEM) and catalytic behavior testing. • Explored the “wet” C 2 H 6 and C 2 H 4 DHA reactions with using steam co-feed. A subsequent reduction as the regeneration step can regenerate the DHA catalyst and recover 99% activity of the fresh performance. • Achieved a 15.3% single-pass aromatic yield from methane by rationally combining the OCM and DHA at different temperatures. • Conducted a 105-hour stability test with an improved regeneration procedure, with an average aromatic yield of 13.8%. • Developed new catalyst and achieved a record-high 23.2% yield.

03 NATURAL GAS↗

Microwave Meissner screening properties of proximity-coupled topological-insulator / superconductor bilayers

The proximity-coupled topological-insulator / superconductor (TI/SC) bilayer system is a representative system to realize topological superconductivity. In order to better understand this unique state and enable future applications of the TI/SC bilayer, a comprehensive characterization and understanding of the microscopic properties of the bilayer are required. In this work, a microwave Meissner screening study, which exploits a high-precision microwave resonator technique, is conducted on the SmB 6 /YB 6 thin-film bilayers as an example TI/SC system. The study reveals spatially dependent electrodynamic screening response of the TI/SC system that is not accessible to other techniques, from which the corresponding microscopic properties of a TI/SC bilayer can be obtained. The TI thickness dependence of the effective penetration depth suggests the existence of a bulk insulating region in the TI layer. The spatially dependent electrodynamic screening model analysis provides an estimate for the characteristic lengths of the TI/SC bilayer: normal penetration depth, normal coherence length, and the thickness of the surface states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Floquet-engineered fast SNAP gates in weakly coupled circuit-QED systems

Superconducting cavities with high quality factors, coupled to a fixed-frequency transmon, provide a state-of-the-art platform for quantum information storage and manipulation. The commonly used selective number-dependent arbitrary phase ( SNAP ) gate faces significant challenges in ultrahigh-coherence cavities, where the weak dispersive shifts necessary for preserving high coherence typically result in prolonged gate times. Here, in this work, we propose a protocol to achieve high-fidelity SNAP gates that are orders of magnitude faster than the standard implementation, surpassing the speed limit set by the bare dispersive shift. We achieve this enhancement by dynamically amplifying the dispersive coupling via sideband interactions, followed by quantum optimal control on the Floquet-engineered system. We also present a unified perturbation theory that explains both the gate acceleration and the associated benign drive-induced decoherence, corroborated by Floquet-Markov simulations. These results pave the way for the experimental realization of high-fidelity, selective control of weakly coupled, high-coherence cavities, and expanding the scope of optimal control techniques to a broader class of Floquet quantum systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterizing Midcircuit Measurements on a Superconducting Qubit Using Gate Set Tomography

Measurements that occur within the internal layers of a quantum circuit—midcircuit measurements—are a useful quantum-computing primitive, most notably for quantum error correction. Midcircuit measurements have both classical and quantum outputs, so they can be subject to error modes that do not exist for measurements that terminate quantum circuits. In this work, we show how to characterize midcircuit measurements, modeled by quantum instruments, using a technique that we call quantum instrument linear gate set tomography (QILGST). We then apply this technique to characterize a dispersive measurement on a superconducting transmon qubit within a multiqubit system. By varying the delay time between the measurement pulse and subsequent gates, we explore the impact of residual cavity photon population on measurement error. QILGST can resolve different error modes and quantify the total error from a measurement; in our experiment, for delay times above 1000 ns we measure a total error rate (i.e., half diamond distance) of ϵ$\diamond$ = 8.1 ± 1.4%, a readout fidelity of 97.0 ± 0.3%, and output quantum-state fidelities of 96.7 ± 0.6% and 93.7 ± 0.7 % when measuring 0 and 1, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗