Search NASA⌕ Search

SEARCH · Search NASA

Results for “millimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Demonstration of a MOT in a sub-millimeter membrane hole

Abstract We demonstrate the generation of a cold-atom ensemble within a sub-millimeter diameter hole in a transparent membrane, a so-called “membrane MOT”. With a sub-Doppler cooling process, the atoms trapped by the membrane MOT are cooled down to 10 $$\upmu$$ μ K. The atom number inside the unbridged/bridged membrane hole is about $$10^4$$ 10 4 to $$10^5$$ 10 5 , and the $$1/e^2$$ 1 / e 2 -diameter of the MOT cloud is about 180 $$\upmu$$ μ m for a 400 $$\upmu$$ μ m-diameter membrane hole. Such a membrane device can, in principle, efficiently load cold atoms into the evanescent-field optical trap generated by the suspended membrane waveguide for strong atom-light interaction and provide the capability of sufficient heat dissipation at the waveguide. This represents a key step toward the photonic atom trap integrated platform (ATIP).

74 ATOMIC AND MOLECULAR PHYSICS↗

Millimeter-wave Point Sources from the 2500 Square Degree SPT-SZ Survey: Catalog and Population Statistics

In this work, we present a catalog of emissive point sources detected in the SPT-SZ survey, a contiguous 2530- square-degree area surveyed with the South Pole Telescope (SPT) from 2008 - 2011 in three bands centered at 95, 150, and 220GHz. The catalog contains 4845 sources measured at a significance of 4.5σ or greater in at least one band, corresponding to detections above approximately 9.8, 5.8, and 20.4 mJy in 95, 150, and 220 GHz, respectively. Spectral behavior in the SPT bands is used for source classification into two populations based on the underlying physical mechanisms of compact, emissive sources that are bright at millimeter wavelengths: synchrotron radiation from active galactic nuclei and thermal emission from dust. The latter population includes a component of high-redshift sources often referred to as submillimeter galaxies (SMGs). In the relatively bright flux ranges probed by the survey, these sources are expected to be magnified by strong gravitational lensing. The survey also contains sources consistent with protoclusters, groups of dusty galaxies at high redshift undergoing collapse. We cross-match the SPT-SZ catalog with external catalogs at radio, infrared, and X-ray wavelengths and identify available redshift information. The catalog splits into 3980 synchrotron-dominated and 865 dust-dominated sources and we determine a list of 506 SMGs. Ten sources in the catalog are identified as stars. We calculate number counts for the full catalog, and synchrotron and dusty components, using a bootstrap method and compare our measured counts with models. This paper represents the third and final catalog of point sources in the SPT-SZ survey.

79 ASTRONOMY AND ASTROPHYSICS↗

EMISSA (Exploring Millimeter Indicators of Solar-Stellar Activity): I. The initial millimeter–centimeter main-sequence star sample

Due to their wide wavelength coverage across the millimeter to centimeter (mm–cm) range and their increased sensitivity, modern interferometric arrays facilitate observations of the thermal and non-thermal radiation that is emitted from different layers in the outer atmospheres of stars. We study the spectral energy distribution (S obs (ν)) of main-sequence stars based on archival observations in the mm–cm range with the aim to study their atmospheric stratification as a function of stellar type. The main-sequence stars with significant detection in mm bands were identified in the ALMA Science Archive. These data were then complemented with spectral flux data in the extreme ultraviolet to cm range as compiled from various catalogues and observatory archives. We compared the resultant S obs (ν) of each star with a photospheric emission model (S mod (ν)) calculated with the PHOENIX code. The departures of S obs (ν) from S mod (ν) were quantified in terms of a spectral flux excess parameter (ΔS/S mod ) and studied as a function of stellar type. The initial sample consists of 12 main-sequence stars across a broad range of spectral types from A1 to M3.5 and the Sun-as-a-star as reference. The stars with T eff = 3000–7000 K (F–M type) showed a systematically higher S obs (ν) than S mod (ν) in the mm–cm range. Their ΔS/S mod exhibits a monotonic rise with decreasing frequency. The steepness of this rise is higher for cooler stars in the T eff = 3000–7000 K range, although the single fully convective star (T eff ~ 3000 K) in the sample deviates from this trend. Meanwhile, Sobs(ν) of the A-type stars agrees with S mod (ν) within errors. The systematically high ΔS/S mod in F–M stars indicates hotter upper atmospheric layers, that is, a chromosphere and corona in these stars, like for the Sun. The mm–cm ΔS/S mod spectrum offers a way to estimate the efficiency of the heating mechanisms across various outer atmospheric layers in main-sequence stars, and thereby to understand their structure and activity. We emphasise the need for dedicated surveys of main-sequence stars in the mm–cm range.

79 ASTRONOMY AND ASTROPHYSICS↗

Millimeter-wave Detections of Symbiotic Stars in SPT and ACT Data

We present the results of a joint targeted search of candidate symbiotic stars at millimeter wavelengths using the South Pole Telescope (SPT) and the Atacama Cosmology Telescope (ACT). Candidates are selected from the New Online Database of Symbiotic Variables, restricting to objects that are within either the SPT-3G or ACT~DR6 footprint, covering most of the southern hemisphere and up to a declination of $+20^\circ$. Forced photometry on the 828 candidate symbiotic star locations in SPT and ACT data results in 31 unique objects detected with more than a $3σ$ significance using two frequency bands: 18 confirmed and 13 suspected symbiotic stars. We provide the SPT and ACT 95/98, 150, and 220~GHz light curves, along with optical and infrared light curves from 2016--2026, as well as spectral energy distributions, physical parameters from the literature, and brief summaries regarding the nature of each individual object. Using Herschel SPIRE data from 2013, we place upper limits on millimeter flux for CN Cha near the beginning of the optical rise in its 2012/2013 nova, which suggests a strong variability and lag at millimeter wavelengths and results in a rare observance of a Galactic millimeter slow transient. In addition, we provide coadded thumbnails and light curves for the remaining 797 candidate symbiotic stars that did not pass our detection thresholds. Millimeter-wave emission from symbiotic stars is primarily a combination of free-free emission of the ionization region and optically thick blackbody emission of the cooler dust components of the system. When combined with contemporaneous multi-wavelength observations, millimeter-wave observations can be used to test binary models of symbiotic stars and provide insight on the geometry and physical properties of these systems.

Tandoi, C. [Illinois U., Urbana, Astron. Dept.] (O↗

Simultaneous Millimeter-wave, Gamma-Ray, and Optical Monitoring of the Blazar PKS 2326-502 during a Flaring State

Including millimeter-wave data in multiwavelength studies of the variability of active galactic nuclei (AGN) can provide insights into AGN physics that are not easily accessible at other wavelengths. We demonstrate in this work the potential of cosmic microwave background (CMB) telescopes to provide long-term, high-cadence millimeter-wave AGN monitoring over large fractions of sky. We report on a pilot study using data from the SPTpol instrument on the South Pole Telescope (SPT), which was designed to observe the CMB at arcminute and larger angular scales. Between 2013 and 2016, SPTpol was used primarily to observe a single 500 deg2 field, covering the entire field several times per day with detectors sensitive to radiation in bands centered at 95 and 150 GHz. We use SPT 150 GHz observations to create AGN light curves, and we compare these millimeter-wave light curves to those at other wavelengths, in particular γ-ray and optical. In this Letter, we focus on a single source, PKS 2326-502, which has extensive, day-timescale monitoring data in gamma-ray, optical, and now millimeter-wave between 2013 and 2016. We find PKS 2326-502 to be in a flaring state in the first 2 yr of this monitoring, and we present a search for evidence of correlated variability between millimeter-wave, optical R-band, and γ-ray observations. This pilot study is paving the way for AGN monitoring with current and upcoming CMB experiments such as SPT-3G, Simons Observatory, and CMB-S4, including multiwavelength studies with facilities such as Vera C. Rubin Observatories Large Synoptic Survey Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

Millimeter wave traveling wave tubes for the 21st Century

Traveling wave tubes are rapidly evolving to provide unprecedented power level in comparison to solid state devices in the millimeter waves region of the spectrum (80–300 GHz) thus enabling a wide range of applications. Wireless communications, imaging, plasma diagnostics, healthcare and many others will gain substantial features if high power at millimeter waves would be available from compact sources. The development of fabrication technologies is proving crucial for introducing new topologies and structures for millimeter wave vacuum electronic devices, compatible with the dimensions dictated by the short wavelength that poses substantial manufacturing challenges due to tight tolerances. This review paper will provide an overview of the principles, evolution and state of the art of one of the most widely utilized vacuum electronic device, the traveling wave tube (TWT). The wide band, high gain features of TWTs make those devices the most promising solutions for high power at millimeter waves and THz frequencies.

42 ENGINEERING↗

Low-loss millimeter-wave resonators with an improved coupling structure

Millimeter-wave superconducting resonators are a useful tool for studying quantum device coherence in a new frequency domain. However, improving resonators is difficult without a robust and reliable method for coupling millimeter-wave signals to 2D structures. We develop and characterize a tapered transition structure coupling a rectangular waveguide to a planar slotline waveguide with better than 0.5 dB efficiency over 14 GHz, and use it to measure ground-shielded resonators in the W band (75–110 GHz). Having decoupled the resonators from radiative losses, we consistently achieve single-photon quality factors above 10 5 , with a two-level-system loss limit above 10 6 , and verify the effectiveness of oxide removal treatments to reduce loss. These values are 4–5 times higher than those previously reported in the W band, and much closer to typical planar microwave resonators. The improved losses demonstrated by these on-chip millimeter-wave devices shed new light on quantum decoherence in a different frequency regime, offer increased selectivity for high-frequency detectors, and enables new possibilities for hybrid quantum experiments integrating millimeter-wave frequencies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated millimeter-wave cavity electro-optic transduction

Emerging communications and computing technologies will rely ever-more on expanding the useful radio frequency spectrum into the millimeter-wave and terahertz frequency range. Both classical and quantum applications would benefit from advancing integration and incorporation of millimeter-wave and electro-optic technologies into common devices, such as modulators. Here we demonstrate an integrated triply-resonant, superconducting electro-optic transducer. Our design incorporates an on-chip 107 GHz niobium titanium nitride superconducting resonator, modulating a thin-film lithium niobate optical racetrack resonator operating at telecom wavelengths. We observe a maximum photon transduction efficiency of η OE ≈ 0.82 × 10 −6 and an average single-photon electro-optic interaction rate of g 0 /2π ≈ 0.7 kHz. We also present a study and analysis of the challenges associated with the design of integrated millimeter-wave resonators and propose possible solutions to these challenges. Our work paves the way for further advancements in resonant electro-optic technologies operating at millimeter-wave frequencies.

47 OTHER INSTRUMENTATION↗

Detecting the Presence of Intrusive Drilling in Secure Transport Containers Using Non-Contact Millimeter-Wave Radar

We employ a 77–81 GHz frequency-modulated continuous-wave (FMCW) millimeter-wave radar to sense anomalous vibrations during vehicle transport at highway speeds for the first time. Secure metallic containers can be breached during transport by means of drilling into their sidewalls but detecting a drilling signature is difficult because the large vibrations of transport drown out the small vibrations of drilling. For the first time, we demonstrate that it is possible to use a non-contact millimeter-wave radar sensor to detect this micron-scale intrusive drilling while highway-speed vehicle movement shakes the container. With the millimeter-wave radar monitoring the microdoppler signature of the container’s vibrating walls, we create a novel signal-processing pipeline consisting of range–angle tracking, time–frequency analysis, horizontal stripe image convolution, and principal component analysis to create a robust and powerful detection statistic to alarm if drilling is present. To support this pipeline, we develop a statistical model combining the vibrating container and the random vibrations induced by vehicle movement to explore the robustness of the sensor’s detection capabilities. The presented results strongly support the inclusion of a millimeter-wave radar vibration sensor into a transport security system.

Wagner, Samuel↗

Millimeter-Wave Imaging Technology Development for Real-Time 2D and 3D Fusion Plasma Diagnostics

Including a one year No-Cost Extension, The University of California, Davis has been funded since 2020 to advance innovative millimeter-wave diagnostics for fusion plasma research. This work includes: (1) Developing and applying cutting-edge System-on-Chip millimeter wave Integrated Circuit (IC) technology for Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometry (MIR) on the DIII-D tokamak and the NSTX-U spherical tokamak. (2) Development of radiation-hardened millimeter-wave chip for diagnostics in harsh environments, utilizing wide bandgap Gallium Nitride (GaN) semiconductors. (3) Integrating forward-modeling synthetic diagnostics to enable advanced, real-time plasma prediction and feedback control. Originally planned as a three-year program (2020–2023), the project was granted a one-year no-cost extension, extending its duration through the end of 2024.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Full-polarization millimeter wavelength variability of Sagittarius A * during the 2018 EHT campaign

Context. Sagittarius A* (Sgr A*), the supermassive black hole at the center of the Milky Way, provides a unique laboratory to study accretion dynamics and plasma processes near the event horizon. Aims. We investigated the variability and polarization properties of Sgr A* using ALMA observations during the 2018 Event Horizon Telescope campaign. Methods. We analyzed high-cadence full-polarization light curves from ALMA at millimeter wavelengths, performed time-series analysis, and investigated the temporal behavior during an X-ray flare observed by Chandra on 2018 April 24. The variability characteristics are compared with expectations from standard accretion flow models. Results. We find low variability in total intensity (σ/μ < 10%), but significantly higher variability in linear and circular polarization (∼30% and ∼50%, respectively). A time-series analysis reveals red-noise variability, with power spectral densities between −2 and −3 across all Stokes parameters. Polarized intensity shows stable intra-day timescales, while total intensity exhibits more variable timescales, suggesting distinct emission regions, with polarization likely arising from a coherent structure. On April 24, a statistically significant inter-band delay in polarized intensity coincides with a near-simultaneous X-ray and millimeter peak that deviates from the typical delayed flare scenario. This event also features enhanced millimeter variability and coherent polarization loop evolution. The observed simultaneity challenges standard models of transient synchrotron emission with cooling delays, favoring instead a scenario of continuous energy injection in an optically thin region. Conclusions. Our results offer new constraints on the physical mechanisms driving variability in Sgr A*, and provide key observational input for refining theoretical models of accretion and plasma behavior in the vicinity of supermassive black holes.

Galaxy: center↗

High-precision millimeter-wave frequency determination through plasmonic photomixing

We present a technique for high-precision millimeter-wave frequency determination through plasmonic photomixing. Our technique utilizes a plasmonic photomixer pumped by an optical frequency comb with a high-stability millimeter-wave beat frequency. The plasmonic photomixer down-converts the millimeter-wave signal to the radio frequency regime at which high-accuracy frequency counters are available. The precision of this technique is determined by the frequency stability of the optical beat frequency, which can be directly characterized in the presented experimental setup. We demonstrate frequency measurement precision as low as 3.9×10 −10 at 95 GHz through plasmonic photomixing without phase-locking the optical frequency comb.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of Millimeter-wavelength Flares from Two Accreting White Dwarf Systems in the SPT-3G Galactic Plane Survey

Blind discoveries of millimeter-wave transient events in nontargeted surveys, as opposed to follow-up or pointed observations, have only become possible in the past decade using cosmic microwave background surveys. Here we present the first results from the SPT-3G Galactic Plane Survey—the first dedicated high-sensitivity, wide-field, time-domain, millimeter-wave survey of the Galactic Plane, conducted with the South Pole Telescope (SPT) using the SPT-3G camera. The survey field covers approximately 100 deg 2 near the Galactic center. In 2023 and 2024, this survey consisted of roughly 1500 individual 20 minute observations in three bands centered at 95, 150, and 220 GHz, with plans for more observations in the coming years. We report the detection of two transient events exceeding a 5σ threshold in both the 95 and 150 GHz bands in the first 2 yr of SPT-3G Galactic Plane Survey data. Both events are unpolarized and exhibit durations of approximately 1 day, with peak flux densities at 150 GHz of at least 50 mJy. The peak isotropic luminosities at 150 GHz are on the order of 10 31 erg s −1 . Both events are associated with previously identified accreting white dwarfs. Magnetic reconnection in the accretion disk is a likely explanation for the observed millimeter flares. In the future, we plan to expand the transient search in the Galactic Plane by lowering the detection threshold, enabling single-band detections, analyzing lightcurves on a range of timescales, and including additional data from future observations.

Wan, Y. [Univ. of Illinois at Urbana-Champaign, IL↗

A Search for Millimeter-bright Blazars as Astrophysical Neutrino Sources

The powerful jets of blazars have been historically considered as likely sites of high-energy cosmic-ray acceleration. However, the particulars of the launched jet and the locations of leptonic and hadronic jet loading remain unclear. In the case when leptonic and hadronic particle injection occur jointly, a temporal correlation between synchrotron radiation and neutrino production is expected. We use a first catalog of millimeter wavelength (95–225 GHz) blazar light curves from the Atacama Cosmology Telescope for a time-dependent correlation with 12 yr of muon neutrino events from the IceCube South Pole Neutrino Observatory. Such millimeter emission traces activity of the bright jet base, which is often self-absorbed at lower frequencies and potentially gamma-ray opaque. We perform an analysis of the population, as well as analyses of individual, selected sources. We do not observe a significant signal from the stacked population. TXS 0506+056 is found as the most significant, individual source, though this detection is not globally significant in our analysis of selected active galactic nuclei. Our results suggest that the majority of millimeter-bright blazars are neutrino dim. In general, it is possible that many blazars have lighter, leptonic jets, or that only selected blazars provide exceptional conditions for neutrino production.

Abbasi, R. [Loyola University, Chicago, IL (United↗

In-Band Scattering and Absorption of Infrared Blocking Foam Filters for Millimeter-wave Cameras

Expanded closed-cell polymer foams are widely used as thermal infrared (IR) blocking filters in millimeter-wave cameras, particularly for Cosmic Microwave Background observations. Precise knowledge of their millimeter-wave properties is essential for optimizing sensitivity. We present broadband (150 GHz - 2 THz) transmittance spectroscopy of Styroace-II and several Zotefoam filters, fitting their spectra with a radiative transfer model incorporating dielectric absorption and Rayleigh, Mie, and higher-order scattering. For a typical 5~cm thick filter stack at 280~GHz, Styroace-II exhibits ${\sim}10\%$ scattering with absorption estimated as ${\lesssim}5\%$ by effective-medium theory, while Zotefoam HD30 offers superior performance at ${\sim}3\%$ scattering and absorption likewise bounded to ${{\lesssim}0.3\%}$. Each model component is constrained at the ${\sim}0.1\%$ transmittance level for millimeter wavelengths. We observe batch-to-batch scattering variability of up to 2 percentage points in foams with multiple tested batches. Less commonly used Zotefoam formulations (LD15 and LD24) can further reduce in-band scattering to ${<}1\%$ while maintaining negligible in-band absorption and likely comparable IR blocking due to shared polyethylene absorption features and similar cell sizes. Based on this work, a filter constructed from the best measured LD24 batch has replaced the Styroace-II filter in a Simons Observatory 220/280 GHz Small Aperture Telescope.

Thomas, Alex [Chicago U., Astron. Astrophys. Ctr.;↗

Rotational Millimeter-Wave Shoe Scanner Using the Discrete Fourier Transform for Backprojection-Based Image Reconstruction

An active 3D microwave / millimeter-wave shoe scanner was previously developed at the Pacific Northwest National Laboratory (PNNL) using two linear arrays scanned over a rectilinear aperture. The radar system chirps a frequency sweep from 10-40 GHz. These frequencies allow imaging through optically opaque material such as leather, rubber, plastics, and other dielectrics. The system was designed to detect concealed items in the soles of shoes while allowing people to leave their shoes on through a security checkpoint. To shrink the footprint of the system, a new iteration of the design has been developed that scans the two linear arrays over a circular aperture. This new footprint opens the possibility of it being installed in the floor of a cylindrical millimeter-wave body scanner. The backprojection-based multilayer dielectric image reconstruction developed at PNNL can easily handle arbitrary spatial sampling, accommodating the new rotational shoe scanner design. Commonly, the fast Fourier transform (FFT) is used to efficiently compute the range response from the data collected by the system as a preprocessing step to the backprojection algorithm. It was found that converting to range using the discrete Fourier transform (DFT) directly has some advantages over the FFT. For example, nonlinear and non-uniform frequency sweeps can easily be compensated for during the computation of the DFT and only the range bins of interest need to be computed and their spacing can be chosen arbitrarily. Because the range conversion step of the image reconstruction is the fastest part of the process there is very little speed penalty for using the DFT over the FFT and it can even increase the speed of image reconstruction when the ranges of interest are fewer than the total span that is calculated in the FFT.

Millimeter-wave imaging, microwave imaging, shoe s↗