Search NASA⌕ Search

SEARCH · Search NASA

Results for “millimeter wave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Detecting the Presence of Intrusive Drilling in Secure Transport Containers Using Non-Contact Millimeter-Wave Radar

We employ a 77–81 GHz frequency-modulated continuous-wave (FMCW) millimeter-wave radar to sense anomalous vibrations during vehicle transport at highway speeds for the first time. Secure metallic containers can be breached during transport by means of drilling into their sidewalls but detecting a drilling signature is difficult because the large vibrations of transport drown out the small vibrations of drilling. For the first time, we demonstrate that it is possible to use a non-contact millimeter-wave radar sensor to detect this micron-scale intrusive drilling while highway-speed vehicle movement shakes the container. With the millimeter-wave radar monitoring the microdoppler signature of the container’s vibrating walls, we create a novel signal-processing pipeline consisting of range–angle tracking, time–frequency analysis, horizontal stripe image convolution, and principal component analysis to create a robust and powerful detection statistic to alarm if drilling is present. To support this pipeline, we develop a statistical model combining the vibrating container and the random vibrations induced by vehicle movement to explore the robustness of the sensor’s detection capabilities. The presented results strongly support the inclusion of a millimeter-wave radar vibration sensor into a transport security system.

Wagner, Samuel↗

Millimeter-wave Point Sources from the 2500 Square Degree SPT-SZ Survey: Catalog and Population Statistics

In this work, we present a catalog of emissive point sources detected in the SPT-SZ survey, a contiguous 2530- square-degree area surveyed with the South Pole Telescope (SPT) from 2008 - 2011 in three bands centered at 95, 150, and 220GHz. The catalog contains 4845 sources measured at a significance of 4.5σ or greater in at least one band, corresponding to detections above approximately 9.8, 5.8, and 20.4 mJy in 95, 150, and 220 GHz, respectively. Spectral behavior in the SPT bands is used for source classification into two populations based on the underlying physical mechanisms of compact, emissive sources that are bright at millimeter wavelengths: synchrotron radiation from active galactic nuclei and thermal emission from dust. The latter population includes a component of high-redshift sources often referred to as submillimeter galaxies (SMGs). In the relatively bright flux ranges probed by the survey, these sources are expected to be magnified by strong gravitational lensing. The survey also contains sources consistent with protoclusters, groups of dusty galaxies at high redshift undergoing collapse. We cross-match the SPT-SZ catalog with external catalogs at radio, infrared, and X-ray wavelengths and identify available redshift information. The catalog splits into 3980 synchrotron-dominated and 865 dust-dominated sources and we determine a list of 506 SMGs. Ten sources in the catalog are identified as stars. We calculate number counts for the full catalog, and synchrotron and dusty components, using a bootstrap method and compare our measured counts with models. This paper represents the third and final catalog of point sources in the SPT-SZ survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Aerosol-Jet Printed Transferable Millimeter-Wave Circuits

Printed millimeter wave (mmW) electronics have been of high interest in the field of communications for some time now due to the potential ability to fabricate mmW systems that utilize 3-Dimension Heterogeneous Integration (3DHI) to improve performance beyond traditional systems. Here, in this paper, a method for fabricating transferable mmW structures via aerosol-jet printing (AJP) is presented. A PDMS stamp assisted liftoff procedure is developed to separate the printed part from a rigid printing support surface and apply it to an adhesive target surface. Several microstrip (MS) line structures are demonstrated to characterize the effect of stamp transfer on the RF performance of the printed circuits. The effects of printed vias on RF probe pads and shifts in the resonant frequencies of a Beatty standard line after transfer are considered and characterized using S-parameter measurements.

42 ENGINEERING↗

Low-loss millimeter-wave resonators with an improved coupling structure

Millimeter-wave superconducting resonators are a useful tool for studying quantum device coherence in a new frequency domain. However, improving resonators is difficult without a robust and reliable method for coupling millimeter-wave signals to 2D structures. We develop and characterize a tapered transition structure coupling a rectangular waveguide to a planar slotline waveguide with better than 0.5 dB efficiency over 14 GHz, and use it to measure ground-shielded resonators in the W band (75–110 GHz). Having decoupled the resonators from radiative losses, we consistently achieve single-photon quality factors above 10 5 , with a two-level-system loss limit above 10 6 , and verify the effectiveness of oxide removal treatments to reduce loss. These values are 4–5 times higher than those previously reported in the W band, and much closer to typical planar microwave resonators. The improved losses demonstrated by these on-chip millimeter-wave devices shed new light on quantum decoherence in a different frequency regime, offer increased selectivity for high-frequency detectors, and enables new possibilities for hybrid quantum experiments integrating millimeter-wave frequencies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simultaneous Millimeter-wave, Gamma-Ray, and Optical Monitoring of the Blazar PKS 2326-502 during a Flaring State

Including millimeter-wave data in multiwavelength studies of the variability of active galactic nuclei (AGN) can provide insights into AGN physics that are not easily accessible at other wavelengths. We demonstrate in this work the potential of cosmic microwave background (CMB) telescopes to provide long-term, high-cadence millimeter-wave AGN monitoring over large fractions of sky. We report on a pilot study using data from the SPTpol instrument on the South Pole Telescope (SPT), which was designed to observe the CMB at arcminute and larger angular scales. Between 2013 and 2016, SPTpol was used primarily to observe a single 500 deg2 field, covering the entire field several times per day with detectors sensitive to radiation in bands centered at 95 and 150 GHz. We use SPT 150 GHz observations to create AGN light curves, and we compare these millimeter-wave light curves to those at other wavelengths, in particular γ-ray and optical. In this Letter, we focus on a single source, PKS 2326-502, which has extensive, day-timescale monitoring data in gamma-ray, optical, and now millimeter-wave between 2013 and 2016. We find PKS 2326-502 to be in a flaring state in the first 2 yr of this monitoring, and we present a search for evidence of correlated variability between millimeter-wave, optical R-band, and γ-ray observations. This pilot study is paving the way for AGN monitoring with current and upcoming CMB experiments such as SPT-3G, Simons Observatory, and CMB-S4, including multiwavelength studies with facilities such as Vera C. Rubin Observatories Large Synoptic Survey Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

Millimeter wave traveling wave tubes for the 21st Century

Traveling wave tubes are rapidly evolving to provide unprecedented power level in comparison to solid state devices in the millimeter waves region of the spectrum (80–300 GHz) thus enabling a wide range of applications. Wireless communications, imaging, plasma diagnostics, healthcare and many others will gain substantial features if high power at millimeter waves would be available from compact sources. The development of fabrication technologies is proving crucial for introducing new topologies and structures for millimeter wave vacuum electronic devices, compatible with the dimensions dictated by the short wavelength that poses substantial manufacturing challenges due to tight tolerances. This review paper will provide an overview of the principles, evolution and state of the art of one of the most widely utilized vacuum electronic device, the traveling wave tube (TWT). The wide band, high gain features of TWTs make those devices the most promising solutions for high power at millimeter waves and THz frequencies.

42 ENGINEERING↗

High-precision millimeter-wave frequency determination through plasmonic photomixing

We present a technique for high-precision millimeter-wave frequency determination through plasmonic photomixing. Our technique utilizes a plasmonic photomixer pumped by an optical frequency comb with a high-stability millimeter-wave beat frequency. The plasmonic photomixer down-converts the millimeter-wave signal to the radio frequency regime at which high-accuracy frequency counters are available. The precision of this technique is determined by the frequency stability of the optical beat frequency, which can be directly characterized in the presented experimental setup. We demonstrate frequency measurement precision as low as 3.9×10 −10 at 95 GHz through plasmonic photomixing without phase-locking the optical frequency comb.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrated millimeter-wave cavity electro-optic transduction

Emerging communications and computing technologies will rely ever-more on expanding the useful radio frequency spectrum into the millimeter-wave and terahertz frequency range. Both classical and quantum applications would benefit from advancing integration and incorporation of millimeter-wave and electro-optic technologies into common devices, such as modulators. Here we demonstrate an integrated triply-resonant, superconducting electro-optic transducer. Our design incorporates an on-chip 107 GHz niobium titanium nitride superconducting resonator, modulating a thin-film lithium niobate optical racetrack resonator operating at telecom wavelengths. We observe a maximum photon transduction efficiency of η OE ≈ 0.82 × 10 −6 and an average single-photon electro-optic interaction rate of g 0 /2π ≈ 0.7 kHz. We also present a study and analysis of the challenges associated with the design of integrated millimeter-wave resonators and propose possible solutions to these challenges. Our work paves the way for further advancements in resonant electro-optic technologies operating at millimeter-wave frequencies.

47 OTHER INSTRUMENTATION↗

Millimeter-Wave Imaging Technology Development for Real-Time 2D and 3D Fusion Plasma Diagnostics

Including a one year No-Cost Extension, The University of California, Davis has been funded since 2020 to advance innovative millimeter-wave diagnostics for fusion plasma research. This work includes: (1) Developing and applying cutting-edge System-on-Chip millimeter wave Integrated Circuit (IC) technology for Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometry (MIR) on the DIII-D tokamak and the NSTX-U spherical tokamak. (2) Development of radiation-hardened millimeter-wave chip for diagnostics in harsh environments, utilizing wide bandgap Gallium Nitride (GaN) semiconductors. (3) Integrating forward-modeling synthetic diagnostics to enable advanced, real-time plasma prediction and feedback control. Originally planned as a three-year program (2020–2023), the project was granted a one-year no-cost extension, extending its duration through the end of 2024.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rotational Millimeter-Wave Shoe Scanner Using the Discrete Fourier Transform for Backprojection-Based Image Reconstruction

An active 3D microwave / millimeter-wave shoe scanner was previously developed at the Pacific Northwest National Laboratory (PNNL) using two linear arrays scanned over a rectilinear aperture. The radar system chirps a frequency sweep from 10-40 GHz. These frequencies allow imaging through optically opaque material such as leather, rubber, plastics, and other dielectrics. The system was designed to detect concealed items in the soles of shoes while allowing people to leave their shoes on through a security checkpoint. To shrink the footprint of the system, a new iteration of the design has been developed that scans the two linear arrays over a circular aperture. This new footprint opens the possibility of it being installed in the floor of a cylindrical millimeter-wave body scanner. The backprojection-based multilayer dielectric image reconstruction developed at PNNL can easily handle arbitrary spatial sampling, accommodating the new rotational shoe scanner design. Commonly, the fast Fourier transform (FFT) is used to efficiently compute the range response from the data collected by the system as a preprocessing step to the backprojection algorithm. It was found that converting to range using the discrete Fourier transform (DFT) directly has some advantages over the FFT. For example, nonlinear and non-uniform frequency sweeps can easily be compensated for during the computation of the DFT and only the range bins of interest need to be computed and their spacing can be chosen arbitrarily. Because the range conversion step of the image reconstruction is the fastest part of the process there is very little speed penalty for using the DFT over the FFT and it can even increase the speed of image reconstruction when the ranges of interest are fewer than the total span that is calculated in the FFT.

Millimeter-wave imaging, microwave imaging, shoe s↗

In-Band Scattering and Absorption of Infrared Blocking Foam Filters for Millimeter-wave Cameras

Expanded closed-cell polymer foams are widely used as thermal infrared (IR) blocking filters in millimeter-wave cameras, particularly for Cosmic Microwave Background observations. Precise knowledge of their millimeter-wave properties is essential for optimizing sensitivity. We present broadband (150 GHz - 2 THz) transmittance spectroscopy of Styroace-II and several Zotefoam filters, fitting their spectra with a radiative transfer model incorporating dielectric absorption and Rayleigh, Mie, and higher-order scattering. For a typical 5~cm thick filter stack at 280~GHz, Styroace-II exhibits ${\sim}10\%$ scattering with absorption estimated as ${\lesssim}5\%$ by effective-medium theory, while Zotefoam HD30 offers superior performance at ${\sim}3\%$ scattering and absorption likewise bounded to ${{\lesssim}0.3\%}$. Each model component is constrained at the ${\sim}0.1\%$ transmittance level for millimeter wavelengths. We observe batch-to-batch scattering variability of up to 2 percentage points in foams with multiple tested batches. Less commonly used Zotefoam formulations (LD15 and LD24) can further reduce in-band scattering to ${<}1\%$ while maintaining negligible in-band absorption and likely comparable IR blocking due to shared polyethylene absorption features and similar cell sizes. Based on this work, a filter constructed from the best measured LD24 batch has replaced the Styroace-II filter in a Simons Observatory 220/280 GHz Small Aperture Telescope.

Thomas, Alex [Chicago U., Astron. Astrophys. Ctr.;↗

System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma

Monolithic, millimeter wave “system-on-chip” technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75–110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements for edge and core region transport physics studies. An F-band receiver chip (up to 140 GHz) is under development for additional fusion facilities with a higher toroidal magnetic field. Visualization diagnostics provide multi-scale and multi-dimensional data in plasma profile evolution. Finally, a significant aspect of imaging measurement is focusing on artificial intelligence for science applications.

47 OTHER INSTRUMENTATION↗

Flaring Stars in a Non-targeted mm-wave Survey with SPT-3G

We present a flare star catalog from four years of non-targeted millimeter-wave survey data from the South Pole Telescope (SPT). The data were taken with the SPT-3G camera and cover a 1500-square-degree region of the sky from $20^{h}40^{m}0^{s}$ to $3^{h}20^{m}0^{s}$ in right ascension and $-42^{\circ}$ to $-70^{\circ}$ in declination. This region was observed on a nearly daily cadence from 2019-2022 and chosen to avoid the plane of the galaxy. A short-duration transient search of this survey yields 111 flaring events from 66 stars, increasing the number of both flaring events and detected flare stars by an order of magnitude from the previous SPT-3G data release. We provide cross-matching to Gaia DR3, as well as matches to X-ray point sources found in the second ROSAT all-sky survey. We have detected flaring stars across the main sequence, from early-type A stars to M dwarfs, as well as a large population of evolved stars. These stars are mostly nearby, spanning 10 to 1000 parsecs in distance. Most of the flare spectral indices are constant or gently rising as a function of frequency at 95/150/220 GHz. The timescale of these events can range from minutes to hours, and the peak $\nu L_{\nu}$ luminosities range from $10^{27}$ to $10^{31}$ erg s$^{-1}$ in the SPT-3G frequency bands.

79 ASTRONOMY AND ASTROPHYSICS↗

Systems, devices, and methods for millimeter wave communication for unmanned aerial vehicles

Systems, devices, and methods are described for controlling, and communicating with, unmanned aerial vehicles (UAVs) over a millimeter wave (mmWave) communication network established between a base station and the UAVs. A communication system may include one or more unmanned aerial vehicles (UAVs). The communication system may further include one or more base stations including millimeter wave (mmWave) antennas configured to generate control signals to the one or more UAVs over an mmWave communication network.

Bhuyan, Arupjyoti↗

Millimeter-wave Detections of Symbiotic Stars in SPT and ACT Data

We present the results of a joint targeted search of candidate symbiotic stars at millimeter wavelengths using the South Pole Telescope (SPT) and the Atacama Cosmology Telescope (ACT). Candidates are selected from the New Online Database of Symbiotic Variables, restricting to objects that are within either the SPT-3G or ACT~DR6 footprint, covering most of the southern hemisphere and up to a declination of $+20^\circ$. Forced photometry on the 828 candidate symbiotic star locations in SPT and ACT data results in 31 unique objects detected with more than a $3σ$ significance using two frequency bands: 18 confirmed and 13 suspected symbiotic stars. We provide the SPT and ACT 95/98, 150, and 220~GHz light curves, along with optical and infrared light curves from 2016--2026, as well as spectral energy distributions, physical parameters from the literature, and brief summaries regarding the nature of each individual object. Using Herschel SPIRE data from 2013, we place upper limits on millimeter flux for CN Cha near the beginning of the optical rise in its 2012/2013 nova, which suggests a strong variability and lag at millimeter wavelengths and results in a rare observance of a Galactic millimeter slow transient. In addition, we provide coadded thumbnails and light curves for the remaining 797 candidate symbiotic stars that did not pass our detection thresholds. Millimeter-wave emission from symbiotic stars is primarily a combination of free-free emission of the ionization region and optically thick blackbody emission of the cooler dust components of the system. When combined with contemporaneous multi-wavelength observations, millimeter-wave observations can be used to test binary models of symbiotic stars and provide insight on the geometry and physical properties of these systems.

Tandoi, C. [Illinois U., Urbana, Astron. Dept.] (O↗

A 3D-Printed Millimeter-Wave Inline Waveguide-to-Coplanar-Waveguide Transition to Enable Dense Spectrometer Arrays for Intensity Mapping Surveys

We present a 3D-printed millimeter-wave, octave-bandwidth, in-line waveguide-to-coplanar-waveguide transition designed to enable focal planes with dense arrays of on-chip spectrometers. These arrays will enable compelling surveys of the large-scale structure of the universe through millimeter-wave intensity mapping. The transition consists of a four-step ridge-waveguide transformer that couples light from a rectangular waveguide onto a coplanar waveguide via an electrical connection made with indium bump bonds. We develop a tolerance-aware optimization approach to identify high-performance transition geometries that are robust to manufacturing variations; the same formulation can be applied to other tolerance-sensitive design problems. We also describe the implementation of a custom apparatus and procedure for bump-bonding a silicon chip to a metallized 3D-printed component. We detail the fabrication of the coplanar waveguide chip and three-dimensional waveguide structure, simulations and metrology of a test device, and room temperature reflectance measurements of this device. The room temperature metrology and reflection measurements are consistent with a model that predicts a coupling efficiency of $\mathord{\sim} 95\%$ at cryogenic temperatures in the 85-170 GHz frequency range.

Stover, Austin [Chicago U.; Chicago U., KICP] (ORC↗

In-situ monitoring for liquid metal jetting using a millimeter-wave impedance diagnostic

Abstract This article presents a millimeter-wave diagnostic for the in-situ monitoring of liquid metal jetting additive manufacturing systems. The diagnostic leverages a T-junction waveguide device to monitor impedance changes due to jetted metal droplets in real time. An analytical formulation for the time-domain T-junction operation is presented and supported with a quasi-static full-wave electromagnetic simulation model. The approach is evaluated experimentally with metallic spheres of known diameters ranging from 0.79 to 3.18 mm. It is then demonstrated in a custom drop-on-demand liquid metal jetting system where effective droplet diameters ranging from 0.8 to 1.6 mm are detected. Experimental results demonstrate that this approach can provide information about droplet size, timing, and motion by monitoring a single parameter, the reflection coefficient amplitude at the input port. These results show the promise of the impedance diagnostic as a reliable in-situ characterization method for metal droplets in an advanced manufacturing system.

42 ENGINEERING↗

Systems, devices, and methods for authenticating millimeter wave devices

Systems, devices, and methods are described for millimeter wave device authentication. A system may include one or more access points. Each access point of the one or more access points is configured to extract, from one or more beam patterns generated via a client device, a beam feature associated with the client device. Each access point may also be configured to transmit the beam feature. The system may also include a server communicatively coupled to the one or more access points and including a database for storing known beam features. The server may be configured to receive the beam feature associated with the client device from at least one access point of the one or more access points. Also, the server may be configured to authenticate the client device in response to the received beam feature matching a known beam feature stored in the at least one database.

Bhuyan, Arupjyoti↗