Search NASA⌕ Search

SEARCH · Search NASA

Results for “millimeter wave radiometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Precipitating Snow Retrievals from Combined Airborne Cloud Radar and Millimeter-Wave Radiometer Observations

An algorithm for retrieving snow over oceans from combined cloud radar and millimeter-wave radiometer observations is developed. The algorithm involves the use of physical models to simulate cloud radar and millimeter-wave radiometer observations from basic atmospheric variables such as hydrometeor content, temperature, and relative humidity profiles and is based on an optimal estimation technique to retrieve these variables from actual observations. A high-resolution simulation of a lake-effect snowstorm by a cloud-resolving model is used to test the algorithm. That is, synthetic observations are generated from the output of the cloud numerical model, and the retrieval algorithm is applied to the synthetic data. The algorithm performance is assessed by comparing the retrievals with the reference variables used in synthesizing the observations. The synthetic observation experiment indicates good performance of the retrieval algorithm. The algorithm is also applied to real observations from the Wakasa Bay field experiment that took place over the Sea of Japan in January and February 2003. The application of the retrieval algorithm to data from the field experiment yields snow estimates that are consistent with both the cloud radar and radiometer observations.

Grecu, Mircea↗

A millimeter-wave radiometer for detecting microbursts

This paper describes a millimeter-wave radiometer for the detection of wind shear from airborne platforms or at airport terminals. This proposed instrument will operate near the group of atmospheric oxygen absorptions centered near 60 GHz, which it will use to sense temperature from a distance. The instrument will use two channels to provide two different temperature measurements, providing the basis for solution of two equations in two unknowns, which are range to the wind shear plume and its temperature. A third channel will measure ambient atmospheric temperature. Depending on the temperature difference between the wind-shear plume and ambient, the standard deviation of range measurement accuracy is expected to be about 1 km at 5 km range, while the temperature measurement standard deviation will be about one-fourth the temperature difference between plume and ambient at this range. The instrument is expected to perform usefully at ranges up to 10 km, giving adequate warning of the presence of wind shear even for high performance jet aircraft. Other atmospheric hazards which might be detected by this radiometer include aircraft wakes and vortices, clear-air turbulence, and wind rotors, although the latter two phenomena would be detected by an airborne version of the instrument. A separate radiometer channel will be provided in the proposed instrument to detect aircraft wakes and vortices based on perturbation of the spectrum of microscopic atmospheric temperature fluctuations caused by the passage of large aircraft.

Mcmillan, Robert↗

A millimeter-wave radiometer technique for measuring ice thickness on the surface of the Space Shuttle's external fueltank

The presence of ice on the outside surface of the external tanks of a Space Shuttle can be detrimental to the launch and it is important to detect its presence and measure its thickness. A description is given of the design of a millimeter-wave radiometer system developed for this purpose. The design is based on model calculations and measurements of the emission properties of an external tank panel, performed at 35, 94 and 140 GHz.

Ulaby, F. T.↗

Sensitivity of Josephson-effect millimeter-wave radiometer

The noise temperature and the minimum detectable temperature of a Josephson junction in video detection of microwave and millimeter-wave radiation has been calculated. We use the well-known method based on a Fokker-Planck equation. The noise temperature can be very close to ambient temperature. Because its predetection bandwidth is very wide, a Josephson-effect radio telescope receiver can have a minimum detectable temperature better than that of a traveling-wave maser.

Ohta, H.↗

An upward looking airborne millimeter wave radiometer for atmospheric water vapor sounding and rain detection

A 90/180 GHz multichannel radiometer is currently under development for NASA's 1985 Hurricane Mission onboard the Convair 990 research aircraft. The radiometer will be a fixed beam instrument with dual corrugated horns and a common lens antenna designed to operate simultaneously at 90 and 180 GHz. The all solid state front-end will contain three double side band data channels at 90 + or - 3 GHz, 180 + or - 3 GHz, and 180 + or - 7 GHz. The airborne radiometer will mount in a window port on the CV-990 and will maintain a fixed beam view approximately 14 degrees off zenith. The radiometer design is a Dicke chopper arrangement selected to achieve maximum absolute temperature accuracy and minimum brightness temperature sensitivity. Analog outputs of the three data channels will be calibrated dc voltages representing the observed radiometric brightness temperatures over the selected integration time.

Gagliano, J. A.↗

Millimeter-Wave Radiometer Imager

A 3-mm radiometer system with mechanically scanned antenna built for use on small aircraft or helicopter to produce near-real-time moderate-resolution images of ground. Main advantage of passive imaging sensor able to provide information through clouds, smoke, and dust when visual and infrared (IR) systems unusable. Used also for variety of remote-sensing applications such as measurements of surface moisture, snow cover, vegetation type and extent, mineral type and extent, surface temperature, and thermal inertia. Possible to map fires and volcanic lava flows through obscuring clouds and smoke.

Wilson, W. J.↗

Passive millimeter wave radiometer system for calibration of infrared cameras

An apparatus for accurate measurement of surface and sub-surface temperatures of an object from a distance without contacting the object is provided. Illustrative embodiments provide for simultaneous measurement of thermal emission and emissivity in the mm-wave regime thereby enabling real-time non-contact measurement of emissivity. Corrected temperatures for the object which may be used for calibration of infrared thermographic cameras are determined from the measurement of emissivity.

Murphy, Ryan D.↗

The Millimeter-Wave Imaging Radiometer (MIR)

The Millimeter-Wave Imaging Radiometer (MIR) is a new instrument being designed for studies of airborne passive microwave retrieval of tropospheric water vapor, clouds, and precipitation parameters. The MIR is a total-power cross-track scanning radiometer for use on either the NASA ER-2 (high-altitude) or DC-8 (medium altitude) aircraft. The current design includes millimeter-wave (MMW) channels at 90, 166, 183 +/- 1,3,7, and 220 GHz. An upgrade for the addition of submillimeter-wave (SMMW) channels at 325 +/- 1,3,7 and 340 GHz is planned. The nadiral spatial resolution is approximately 700 meters at mid-altitude when operated aboard the NASA ER-2. The MIR consists of a scanhead and data acquisition system, designed for installation in the ER-2 superpod nose cone. The scanhead will house the receivers (feedhorns, mixers, local oscillators, and preamplifiers), a scanning mirror, hot and cold calibration loads, and temperature sensors. Particular attention is being given to the characterization of the hot and cold calibration loads through both laboratory bistatic scattering measurements and analytical modeling. Other aspects of the MIR and the data acquisition system are briefly discussed, and diagrams of the location of the MIR in the ER-2 superpod nosecone and of the data acquisition system are presented.

Gasiewski, A. J.↗

An Airborne Conical Scanning Millimeter-Wave Imaging Radiometer (CoSMIR)

An airborne Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) for high-altitude observations from the NASA Research Aircraft (ER-2) is discussed. The primary application of the CoSMIR is water vapor profile remote sensing. Four radiometers operating at 50 (three channels), 92, 150, and 183 (three channels) GHz provide spectral coverage identical to nine of the Special Sensor Microwave Imager/Sounder (SSMIS) high-frequency channels. Constant polarization-basis conical and cross-track scanning capabilities are achieved using an elevation-under-azimuth two-axis gimbals.

Piepmeier, J.↗

Millimeter-wave imaging radiometer for cloud, precipitation and atmospheric water vapor studies

A millimeter-wave imaging radiometer (MIR) developed by NASA Goddard Space Flight Center is described. The MIR is a nine-channel total power radiometer developed for atmospheric research. Three dual-pass band channels are centered about the strongly opaque 183-GHz water vapor absorption line; the frequencies are 183 +/- 1, +/- 3, and +/- 7 GHz. Another channel is located on the wing of this band at 150 GHz. These four channels have varying degrees of opacity from which the water vapor profile can be inferred. The design and salient characteristics of this instrument are discussed, together with its expected benefits.

Racette, P. E.↗

The Airborne Conical Scanning Millimeter-Wave Imaging Radiometer (CoSMIR)

Results of the first science flight of the airborne Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) for high-altitude observations from the NASA ER-2 is discussed. Imagery collected from the flight demonstrates CoSMIR's unique conical/cross-track imaging mode and provides comparison of CoSMIR measurements to those of the Special Sensor Microwave/Temperature-2 (SSM/T-2) satellite radiometer.

Piepmeier, J. R.↗

Remote Measurements of Snowfalls in Wakasa Bay, Japan with Airborne Millimeter- wave Imaging Radiometer and Cloud Radar

In this paper we explore the application of combined millimeter-wave radar and radiometry to remotely measure snowfall. During January-February of 2003, a field campaign was conducted with the NASA P-3 aircraft in Wakasa Bay, Japan for the validation of the AMSRE microwave radiometer on board the Aqua satellite. Among the suite of instruments-on board the P-3 aircraft were the Millimeter-wave Imaging Radiometer (MIR) from the NASA Goddard Space Flight Center and the 94 GHz Airborne Cloud Radar (ACR) which is co-owned and operated by NASA Jet Propulsion Laboratory/University of Massachusetts. MIR is a total power, across-track scanning radiometer that measures radiation at the frequencies of 89, 150, 183.3 +/- 1, 183.3 +/- 3, 183.3 +/-7, 220, and 340 GHz. The MIR has flown many successful missions since its completion in May 1992. ACR is a newer instrument and flew only a few times prior to the Wakasa Bay deployment. These two instruments which are particularly well suited for the detection of snowfall functioned normally during flights over snowfall and excellent data sets were acquired. On January 14, 28, and 29 flights were conducted over snowfall events. The MIR and ACR detected strong signals during periods of snowfall over ocean and land. Results from the analysis of these concurrent data sets show that (1) the scattering of millimeter-wave radiation as detected by the MIR is strongly correlated with ACR radar reflectivity profiles, and (2) the scattering is highly frequency-dependent, the higher the frequency the stronger the scattering. Additionally, the more transparent channels of the MIR (e.g., 89, 150, and 220 GHz) are found to display ambiguous signatures of snowfall because of their exposure to surface features. Thus, the snowfall detection and retrievals of snowfall parameters, such as the ice water path (IWP) and median mass diameter (D(me)) are best conducted at the more opaque channels near 183.3 GHz and 340 GHz. Retrievals of IWP and D(me) using the MIR measurements at 183.3 and 340 GHZ are currently in progress, and the results will be compared with those derived from the ACR reflectivity profiles. Implication from this comparison will be discussed.

Wang, J. R.↗

Millimeter-wave imaging radiometer data processing and development of water vapor retrieval algorithms

This document describes the current status of Millimeter-wave Imaging Radiometer (MIR) data processing and the technical development of the first version of a water vapor retrieval algorithm. The algorithm is being used by NASA/GSFC Microwave Sensors Branch, Laboratory for Hydrospheric Processes. It is capable of a three dimensional mapping of moisture fields using microwave data from airborne sensor of MIR and spaceborne instrument of Special Sensor Microwave/T-2 (SSM/T-2).

Chang, L. Aron↗

Millimeter-Wave Imaging Radiometer (MIR) Data Processing and Development of Water Vapor Retrieval Algorithms

This document describes the final report of the Millimeter-wave Imaging Radiometer (MIR) Data Processing and Development of Water Vapor Retrieval Algorithms. Volumes of radiometric data have been collected using airborne MIR measurements during a series of field experiments since May 1992. Calibrated brightness temperature data in MIR channels are now available for studies of various hydrological parameters of the atmosphere and Earth's surface. Water vapor retrieval algorithms using multichannel MIR data input are developed for the profiling of atmospheric humidity. The retrieval algorithms are also extended to do three-dimensional mapping of moisture field using continuous observation provided by airborne sensor MIR or spaceborne sensor SSM/T-2. Validation studies for water vapor retrieval are carried out through the intercomparison of collocated and concurrent measurements using different instruments including lidars and radiosondes. The developed MIR water vapor retrieval algorithm is capable of humidity profiling under meteorological conditions ranging from clear column to moderately cloudy sky. Simulative water vapor retrieval studies using extended microwave channels near 183 and 557 GHz strong absorption lines indicate feasibility of humidity profiling to layers in the upper troposphere and improve the overall vertical resolution through the atmosphere.

Chang, L. Aron↗

Millimeter-wave Imaging Radiometer (MIR) data processing and development of water vapor retrieval algorithms

This document describes the progress of the task of the Millimeter-wave Imaging Radiometer (MIR) data processing and the development of water vapor retrieval algorithms, for the second six-month performing period. Aircraft MIR data from two 1995 field experiments were collected and processed with a revised data processing software. Two revised versions of water vapor retrieval algorithm were developed, one for the execution of retrieval on a supercomputer platform, and one for using pressure as the vertical coordinate. Two implementations of incorporating products from other sensors into the water vapor retrieval system, one from the Special Sensor Microwave Imager (SSM/I), the other from the High-resolution Interferometer Sounder (HIS). Water vapor retrievals were performed for both airborne MIR data and spaceborne SSM/T-2 data, during field experiments of TOGA/COARE, CAMEX-1, and CAMEX-2. The climatology of water vapor during TOGA/COARE was examined by SSM/T-2 soundings and conventional rawinsonde.

Chang, L. Aron↗