Search NASA⌕ Search

SEARCH · Search NASA

Results for “miniature mass spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Zero voltage mass spectrometry probes and systems

The invention generally relates to zero volt mass spectrometry probes and systems. In certain embodiments, the invention provides a system including a mass spectrometry probe including a porous material, and a mass spectrometer (bench-top or miniature mass spectrometer). The system operates without an application of voltage to the probe. In certain embodiments, the probe is oriented such that a distal end faces an inlet of the mass spectrometer. In other embodiments, the distal end of the probe is 5 mm or less from an inlet of the mass spectrometer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of thermionic filament and carbon nanotube field emitter-based electron ionization sources in cycloidal coded aperture mass analyzers

This report compares the coded aperture imaging performance of thermionic filament and carbon nanotube (CNT) field emitter-based electron sources in cycloidal-coded aperture mass spectrometers. The use of spatially coded apertures in mass spectrometry enables miniaturization by improving throughput without sacrificing resolution. CNT-based electron ionization sources for mass spectrometers provide several potential benefits over conventional thermionic emitters, including low voltage and low power consumption, room temperature operation, long lifetime, and ability to emit electrons in a pulsed mode. However, spatiotemporal variation in electron emission from CNTs is a major disadvantage. In this study, electron emission stability and spatiotemporal stability of the coded aperture image were compared for coded aperture cycloidal mass analyzers with either a CNT-based ion source or a thermionic filament-based ion source. We found that the thermionic filament-based ion source produced a significantly more stable coded aperture image than the CNT based ion source. The aperture image fluctuations in the CNT-based source are likely a result of adsorption and desorption of molecules on the CNT surface that cause local work function changes and induce spatiotemporal variation in electron emission and subsequent ion generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Temperature Dissociation of Neopentanol: Shock Tube/Photoionization Mass Spectrometry Studies

Herein, the pyrolysis mechanism of 2,2-dimethylpropan-1-ol (neopentanol) has been investigated at high temperatures (1128–1401K) and high pressures (5 and 15 bar). The experiments were performed in a miniature shock tube coupled to a time-of-flight mass spectrometer. Cations were generated by tunable vacuum ultraviolet photoionization resulting in multidimensional data sets containing mass and photoionization spectra and the time histories of species. At the elevated temperatures and pressures of this work, neopentanol was determined to dissociate primarily by the scission of a C–C bond yielding tert-butyl and hydroxymethyl radicals. These promptly form isobutene and formaldehyde by H-atom elimination. In the structurally similar molecule neopentane, roaming radical reactions have previously been found to be important under conditions close to the present work (1260–1459 K, 1.1 bar). There are two possible roaming radical reactions for neopentanol. However, no experimental evidence for these reactions was found at the elevated pressures in this study, and the dissociation of neopentanol is dominated by bond scission yielding radical products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Meteorological Conditions and Atmospheric Components Concentration in Urban Sites in Knoxville, USA. 2024

This dataset, which contains five csv files, reports several meteorological conditions such as temperature, wind speed, solar radiation, and net radiation measured in Cumberland Estates Park (CEP) and Socially Equal Energy Efficient Development (SEEED) sites in Knoxville, Tennessee, USA. Also, hourly concentration of particulate matter (PM) with different aerodynamic diameter and inorganic gases such as ozone and nitrogen dioxide measured in the two are included in this dataset. The concentrations of PM and inorganic gases were monitored using the MODULAIR, a low-cost sensor equipped with a solar power module. The measurement of the concentration of biogenic and anthropogenic volatile organic compounds (VOCs) of the two sites was determined using a High-Resolution Proton Transfer Reaction Time of Flight Mass Spectrometer (PTR-ToF-MS). The VOCs were collected using miniature canister (400 mL) equipped with female RAVEqc valve to 1/4” male compression fitting and an integrated passive air sampling kit. This work is a part of a larger study which investigates the impact of soil moisture and plant evapotranspiration on ambient temperature and relative humidity in several city parks in Knoxville, Tennessee.

54 ENVIRONMENTAL SCIENCES↗

Cloud condensation nuclei activity of internally mixed particle populations at a remote marine free troposphere site in the North Atlantic Ocean

Here, this study reports results from research conducted at the Observatory of Mount Pico (OMP), 2225 m above mean sea level on Pico Island in the Azores archipelago in June and July 2017. We investigated the chemical composition, mixing state, and cloud condensation nuclei (CCN) activities of long-range transported free tropospheric (FT) particles. FLEXible PARTicle Lagrangian particle dispersion model (FLEXPART) simulations reveal that most air masses that arrived at the OMP during the sampling period originated in North America and were highly aged (average plume age > 10 days). We probed size-resolved chemical composition, mixing state, and hygroscopicity parameter ($\mathcal{κ}$) of individual particles using computer-controlled scanning electron microscopy with an energy-dispersive X-ray spectrometer (CCSEM-EDX). Based on the estimated individual particle mass from elemental composition, we calculated the mixing state index, $χ$. During our study, FT particle populations were internally mixed ($χ$ of samples are between 53% and 87%), owing to the long atmospheric aging time. We used data from a miniature Cloud Condensation Nucleus Counter (miniCCNC) to derive the hygroscopicity parameter, $\mathcal{κ}$ CCNC . Combining $\mathcal{κ}$ CCNC and FLEXPART, we found that air masses recirculated above the North Atlantic Ocean with lower mean altitude had higher $\mathcal{κ}$ CCNC due to the higher contribution of sea salt particles. We used CCSEM-EDX and phase state measurements to predict single-particle $\mathcal{κ}$ ($\mathcal{κ}$ CCSEM-EDX ) values, which overlap with the lower range of $\mathcal{κ}$ CCNC measured below 0.15 % SS. Therefore, CCSEM-EDX measurements can be useful in predicting the lower bound of $\mathcal{κ}$, which can be used in climate models to predict CCN activities, especially in remote locations where online CCN measurements are unavailable.

54 ENVIRONMENTAL SCIENCES↗

Improved Single-Cell Proteome Coverage Using Narrow-Bore Packed NanoLC Columns and Ultrasensitive Mass Spectrometry

Single-cell proteomics can provide unique insights into biological processes by resolving heterogeneity that is obscured by bulk measurements. Gains in the overall sensitivity and proteome coverage through improvements in sample processing and analysis increase the information content obtained from each cell, particularly for less abundant proteins. Here we report on improved single-cell proteome coverage through the combination of the previously developed Nanodroplet Processing in One Pot for Trace Samples (nanoPOTS) platform with further miniaturization of liquid chromatography (LC) separations and implementation of an ultrasensitive latest-generation mass spectrometry (MS) instrument. Following nanoPOTS sample preparation, protein digest from single cells were separated using a 20-µm-i.d. in-house-packed nanoLC column. Separated peptides were ionized using an etched fused silica emitter capable of stable ionization at the ~20 nL/min flow rate provided by the LC separation. Ultrasensitive LC-MS analysis was achieved using the Orbitrap Eclipse Tribrid mass spectrometer. An average of 362 protein groups were identified by MS/MS from single HeLa cells, and 874 protein groups were identified using the Match Between Runs (MBR) feature of MaxQuant. This represents a >70% increase in label-free proteome coverage for single cells relative to previous efforts using larger-bore (30-µm-i.d.) LC columns coupled to a previous-generation MS (Orbitrap Fusion Lumos).

Cong, Yongzheng↗

A Miniature Multilevel Structures for Lossless Ion Manipulations Ion Mobility Spectrometer with Wide Mobility Range Separation Capabilities

Here, ion mobility spectrometry employing structures for lossless ion manipulations (SLIM-IMS) is an attractive gas-phase separation technique due to its ability to achieve unprecedented effective ion path lengths (>1 km) and IMS resolving powers in a small footprint. The emergence of multilevel SLIM technology, where ions are transferred between vertically stacked SLIM electrode surfaces, has subsequently allowed for ultralong single pass path lengths (>40 m) to be achieved, enabling ultrahigh resolution IMS measurements to be performed over the entire mobility range in a single experiment. The implementation of multiple SLIM levels requires very little additional space for the SLIM system, and we developed a miniature SLIM module (miniSLIM) based on multilevel SLIM technology and report the performance here. The module is 11.1 cm x 6.7 cm x 1.4 cm (L x W x H) and consists of three SLIM levels totaling 1-meter path length. Ion trajectory simulations were used to optimize the SLIM board spacings and SLIM board thicknesses of the miniSLIM IMS system. Methods of efficiently transferring ions between SLIM levels were examined and a new approach using asymmetric traveling waves (TWs) was developed and implemented in the miniSLIM. We experimentally characterized the performance of the --meter multilevel miniSLIM IMS-MS relative to a drift tube IM--MS using an Agilent tuning mixture and tetraalkylammonium cations. The 1-meter miniSLIM achieved a resolving power of up to 131 (CCS/ΔCCS), ~1.5x higher than achievable with a 78 cm path length drift tube IMS, and successfully transmitted the entire ion mobility range in a single separation. We also demonstrated the miniSLIM’s performance as a standalone IMS system (i.e., without MS), showing baseline separation between Agilent tuning mixture cations with the full mobility range observed, and a standard peptide mixture with different charge states readily differentiated. Overall the miniSLIM provides a compact alternative to high performance IMS instruments possessing similar path lengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗