Search NASA⌕ Search

SEARCH · Search NASA

Results for “modified apertures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A novel sector mass spectrograph design for high-order coded aperture Mass Spectrometry with stigmatic aberration correction

Previous works experimentally demonstrated that the application of spatially-coded apertures to simple sector mass spectrographs can result in increased signal intensity while maintaining spectral resolution comparable to that of a conventional slit aperture.[Chen, E.X., et al.: J Am Soc Mass Spectr. 26, 1633 (2015)][Russell, Z.E., et al.: J Am Soc Mass Spectr. 26, 248 (2015)] This spatial coding technique was later applied to a double-focusing Mattauch-Herzog mass spectrograph, and shown to be generally compatible with the architecture.[Russell, Z.E., et al.: J Am Soc Mass Spectr. 27, 1 (2016)] However, the achieved signal gain was limited by the spatial size of the electric sector gap. In this work, we introduce a modified version of the Mattauch-Herzog mass spectrograph with a wide-gap electric sector that is enabled by a novel, segmented-electrode approach, and show via simulation that this modified architecture alone (without aperture coding) achieves a 1.8x improvement in mass resolving power compared to a conventional Mattauch-Herzog spectrograph of equivalent size. Further, simulation of an aperture-coded version of the instrument supports a predicted signal strength increase of 50x with minimal loss of aperture clarity on the sensor due to the increased open area of the high-order coded aperture which can be passed.

47 OTHER INSTRUMENTATION↗

Method of Green’s Potentials for Elliptic PDEs in Domains with Random Apertures

Problems with topological uncertainties appear in many fields ranging from nano-device engineering to the design of bridges. In many of such problems, a part of the domains boundaries is subjected to random perturbations making inefficient conventional schemes that rely on discretization of the whole domain. Here, we study elliptic PDEs in domains with boundaries comprised of a deterministic part and random apertures, and apply the method of modified potentials with Green’s kernels defined on the deterministic part of the domain. This approach allows to reduce the dimension of the original differential problem by reformulating it as a boundary integral equation posed on the random apertures only. The multilevel Monte Carlo method is then applied to this modified integral equation and its optimal ϵ -2 asymptotical complexity is shown. Finally, we provide the qualitative analysis of the proposed technique and support it with numerical results.

97 MATHEMATICS AND COMPUTING↗

A 3-Year Sample of Almost 1,600 Elves Recorded Above South America by the Pierre Auger Cosmic-Ray Observatory

Elves are a class of transient luminous events, with a radial extent typically greater than 250 km, that occur in the lower ionosphere above strong electrical storms. We report the observation of 1,598 elves, from 2014 to 2016, recorded with unprecedented time resolution (100 ns) using the fluorescence detector (FD) of the Pierre Auger Cosmic-Ray Observatory. The Auger Observatory is located in the Mendoza province of Argentina with a viewing footprint for elve observations of 3∙10sup>6 km ₂, reaching areas above the Pacific and Atlantic Oceans, as well as the Córdoba region, which is known for severe convective thunderstorms. Primarily designed for ultrahigh energy cosmic-ray observations, the Auger FD turns out to be very sensitive to the ultraviolet emission in elves. The detector features modified Schmidt optics with large apertures resulting in a field of view that spans the horizon, and year-round operation on dark nights with low moonlight background, when the local weather is favorable. The measured light profiles of 18% of the elve events have more than one peak, compatible with intracloud activity. Within the 3-year sample, 72% of the elves correlate with the far-field radiation measurements of the World Wide Lightning Location Network. The Auger Observatory plans to continue operations until at least 2025, including elve observations and analysis. To the best of our knowledge, this observatory is the only facility on Earth that measures elves with year-round operation and full horizon coverage.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and fabrication of a four-rod radio frequency quadrupole with a variable aperture

Radiofrequency quadrupole (RFQ) linear accelerators with variable aperture cell parameters offer an effective means of accelerating high-intensity ion beams exceeding 100 mA and have been implemented in various RFQ designs. However, in a four-rod RFQ, the use of dielectric perturbation methods to measure the voltage distribution behind the rod electrodes is not applicable when implementing variable aperture geometries, because changes in the rod shape influence the electric field at the location of the perturbation element. Therefore, it was necessary to design the rod profile for each cell such that the electric field distribution behind the rods remains unaffected by changes in the aperture. In this study, we present a method to adjust the voltage distribution by modifying the geometry of the rod electrodes according to each cell's aperture parameters. This design approach enables the integration of variable aperture cells into a four-rod RFQ linac, significantly enhancing the achievable beam current. To ensure uniform capacitance and maintain a constant rod-electrode voltage despite variations in the average aperture radius, we developed a systematic method for shaping the rod electrodes. This method was refined using two-dimensional (2D) and three-dimensional (3D) electromagnetic field simulations to optimize the electrode cross-sectional profiles. The fabricated rod electrodes were then installed in a four-rod RFQ, and the electric field distribution was measured using the perturbation method and tuned by adjusting the base plates. As a result, the measured variation of ±1.1 % confirms that this design methodology can produce a sufficiently uniform voltage distribution for high-current beam acceleration. These results demonstrate the practical feasibility of a variable-aperture four-rod RFQ linac.

43 PARTICLE ACCELERATORS↗

Improving the electrostatic design of the Jefferson Lab 300 kV DC photogun

The 300 kV DC high voltage photogun at Jefferson Lab was redesigned to deliver electron beams with a much higher bunch charge and improved beam properties. The original design provided only a modest longitudinal electric field ( E z ) at the photocathode, which limited the achievable extracted bunch charge. To reach the bunch charge goal of approximately few nC with 75 ps full-width at half-maximum Gaussian laser pulse width, the existing DC high voltage photogun electrodes and anode–cathode gap were modified to increase E z at the photocathode. In addition, the anode aperture was spatially shifted with respect to the beamline longitudinal axis to minimize the beam deflection introduced by the non-symmetric nature of the inverted insulator photogun design. We present the electrostatic design of the original photogun and the modified photogun and beam dynamics simulations that predict vastly improved performance. We also quantify the impact of the photocathode recess on beam quality, where recess describes the actual location of the photocathode inside the photogun cathode electrode relative to the intended location. A photocathode unintentionally recessed/misplaced by sub-millimeter distance can significantly impact the downstream beam size.

47 OTHER INSTRUMENTATION↗

Room temperature slot-die coated perovskite layer modified with sulfonyl-γ-AApeptide for high performance perovskite solar devices

Perovskite solar cells (PSCs) exhibited remarkable progress for small aperture area cells, however, the performance of its counterpart, large aperture area cells, lags due to non-uniform and defective perovskite layers. Here, we fabricate reproducible large area homogeneous perovskite films at room temperature and without controlling humidity (up to 40 % RH) with a slot die coater on a c-TiO 2 layer deposited using a large area chemical bath. A new artificial peptide – sulfonyl-γ-AApeptide (F-GLU-S) was employed to modify the slot-die coated perovskite surface, grain boundaries and electronic defects. The multi-functional F-GLU-S with carbonyl, carboxyl, sulfonyl, benzene, and chloro groups was capable of strongly interacting with the perovskite layer and repairing the uncoordinated Pb 2+ ions and halide vacancies. As a result, both the electron and hole densities of defects were significantly suppressed; consequently, the non-radiative recombination was effectively suppressed for the modified device which can be explicitly seen in the device performance where both V oc and FF of the modified device improved considerably. Therefore, F-GLU-S modified slot-die coated MAPbI 3 – based devices demonstrated outstanding performance of 21.44 % PCE with a V oc of 1.13 V, J sc of 24.64 cm –2 , and FF 76.99 %. Furthermore, F-GLU-S passivation impeded the infiltration of moisture and oxygen due to its hydrophobic nature and defect repair potential. As a result, the modified device retained above 92 % of its original PCE after 720 h in air (room temperature and 40–60 % RH).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Delineation of the impact on temporal behaviors of off-axis photoemission in an ultrafast electron microscope

Efforts to push the spatiotemporal imaging-resolution limits of femtosecond laser-driven ultrafast electron microscopes (UEMs) to the combined angstrom–fs range will benefit from stable sources capable of generating high bunch charges. Recent demonstrations of unconventional off-axis photoemitting geometries are promising, but connections to the observed onset of structural dynamics are yet to be established. Here we use the in-situ photoexcitation of coherent phonons to quantify the relative time-of-flight (r-TOF) of photoelectron packets generated from the Ni Wehnelt aperture and from a Ta cathode set-back from the aperture plane. We further support the UEM experiments with particle-tracing simulations of the precise electron-gun architecture and photoemitting geometries. In this way, we measure discernible shifts in electron-packet TOF of tens of picoseconds for the two photoemitting surfaces. Furthermore, these shifts arise from the impact that the Wehnelt-aperture off-axis orientation has on the electron-momentum distribution, which modifies both the collection efficiency and the temporal-packet distribution relative to on-axis emission. Future needs are identified; we expect this and other developments in UEM electron-gun configuration to expand the range of material phenomena that can be directly imaged on scales commensurate with fundamental structural dynamics.

47 OTHER INSTRUMENTATION↗

Single-shot measurement of the nonlinear refractive index of air at 92 µm with a picosecond terawatt CO 2 laser

We developed a simple, accurate single-shot method to determine the nonlinear refractive index of air by measuring the evolution of the spatial shape of a laser beam propagating through the atmosphere. A distinctive feature of this new method, which relies on a modified Fresnel propagation model for data analysis, is the use of a hard aperture for producing a welldefined, high-quality beam from a comparatively nonuniform quasi-flat-top beam which is typical for highpeak-power lasers. The nonlinear refractive index of air for a very short (2 ps) long-wave infrared (LWIR) laser pulse was measured for the first time, yielding n 2 = 3.0 × 10 -23 m 2 /W at 9.2 µm. This result is 40% lower than a corresponding measurement with longer (200 ps) LWIR pulses at a similar wavelength.

43 PARTICLE ACCELERATORS↗

Incident beam optics optimization for the single crystal neutron diffractometer Pioneer with a polarized beam option

Pioneer, a next-generation single-crystal neutron diffractometer, is under development for Oak Ridge National Laboratory’s Second Target Station. Designed to address a wide range of scientific questions, Pioneer will deliver homogeneous neutron beams with customizable size and divergence and provide a polarized beam option. This article introduces its incident beam optics, highlighting the optimization methodology and the simulated performance. Pioneer will utilize a modified elliptical-straight guide for neutron transport and deploy slit packages and insertable apertures to control beam size and divergence. The optimized guide geometry matches the optimal-and-full-sample-illumination condition, and the beam control system effectively filters out unwanted neutrons while preserving the desired ones. In addition, we have found that polygon-approximated guides provide satisfactory transport efficiency and beam homogeneity, eliminating the need for truly curved guides. Further, to enhance neutronics performance and reduce cost, the coatings of supermirror elements are individually optimized to the lowest half-integer m-values that are sufficient to deliver the desired neutrons. After evaluating polarizing V-cavities and 3 He spin filters over the default polarized wavelength band of 1.2–5.5 Å, we selected a translatable multichannel polarizing V-cavity as the incident beam polarizer. Strategically placed at a location where the beam divergence is low and a large in-guide gap has negligible impact on transport efficiency, the optimized V-cavity achieves an average P 2 T of ~35%.

47 OTHER INSTRUMENTATION↗

Combined Function Magnets for the Fermilab PIP-II Booster Upgrade

The Proton Improvement Plan II (PIP-II) is an enhancement to the Fermilab accelerator complex enabling a high intensity proton beam to support the laboratory’s experiments. The heart of PIP-II is a superconducting linac which will increase the injection energy in the booster from the existing 400 MeV to 800 MeV. To make room for the modified injection into the booster, two shorter defocusing gradient magnets have been designed. Two wide aperture defocusing gradient magnets have also been designed to go on either side of the extraction septa to reduce extractions losses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A coded aperture microscope for X-ray fluorescence full-field imaging

The design and construction of an instrument for full-field imaging of the X-ray fluorescence emitted by a fully illuminated sample are presented. The aim is to produce an X-ray microscope with a few micrometers spatial resolution, which does not need to scan the sample. Since the fluorescence from a spatially inhomogeneous sample may contain many fluorescence lines, the optic which will provide the magnification of the emissions must be achromatic, i.e. its optical properties must be energy-independent. The only optics which fulfill this requirement in the X-ray regime are mirrors and pinholes. The throughput of a simple pinhole is very low, so the concept of coded apertures is an attractive extension which improves the throughput by having many pinholes, and retains the achromatic property. Modified uniformly redundant arrays (MURAs) with 10 µm openings and 50% open area have been fabricated using gold in a lithographic technique, fabricated on a 1 µm-thick silicon nitride membrane. The gold is 25 µm thick, offering good contrast up to 20 keV. The silicon nitride is transparent down into the soft X-ray region. MURAs with various orders, from 19 up to 73, as well as their respective negative (a mask where open and closed positions are inversed compared with the original mask), have been made. Having both signs of mask will reduce near-field artifacts and make it possible to correct for any lack of contrast.

36 MATERIALS SCIENCE↗

Improved Electrostatic Design of the Jefferson Lab 300 kV DC Photogun and the Minimization of Beam Deflection

An electron beam with high bunch charge and high repetition rate is required for electron cooling of the ion beam to achieve the high luminosity required for the proposed electron-ion colliders. An improved design of the 300 kV DC high voltage photogun at Jefferson Lab was incorporated toward overcoming the beam loss and space charge current limitation experienced in the original design. To reach the bunch charge goal of ~ few nC within 75 ps bunches, the existing DC high voltage photogun electrodes and anode-cathode gap were modified to increase the longitudinal electric field (Ez) at the photocathode. The anode-cathode gap was reduced to increase the Ez at the photocathode, and the anode aperture was spatially shifted with respect to the beamline longitudinal axis to minimize the beam deflection introduced by the geometric asymmetry of the inverted insulator photogun. The electrostatic design and beam dynamics simulations were performed to determine the required modification. Beam-based measurement from the modified gun confirmed the reduction of the beam deflection, which is presented in this contribution.

Mamun, M. A.↗

Application and performance of the novel Elcomat 5000 autocollimator in slope-measuring profilometry of beamline optics

Autocollimators are used in profilometers for the precise form measurement of beam-shaping optics for synchrotron light sources and x-ray free-electron lasers. This application requires using an aperture stop, typically 2.5 mm in diameter, which limits the footprint of the autocollimator’s measuring beam on the optics to achieve a sufficiently high lateral resolution. Central to the development of profilometry has been the availability of commercial autocollimators, such as the Elcomat 3000 from Möller–Wedel Optical. Although autocollimators are generally not designed for use with small apertures, this device has proven capable and has become the de facto standard. Now that it has been replaced by the Elcomat 5000, we evaluate the performance of several autocollimators of this type at small apertures, including the characterization of instrument transfer functions with a chirped height profile. We demonstrate that the Elcomat 5000 is capable of repeatable angle measurements with a standard deviation of 0.014 arcsec at an aperture diameter of 1.6 mm, whereas the Elcomat 3000 achieves 0.03 arcsec at 2.5 mm, comparing models with modified reticle designs. Here, we also investigate the influence of optical aberrations of the autocollimator’s objective and their changes with the path length to the surface under test. We characterize the sensitivity of the angle measurement to changes in environmental parameters, in particular, barometric pressure. These efforts are aimed at approaching fundamental limits in the characterization of the shape of optical surfaces with autocollimator-based profilometers so that these are ready for characterizing the next generation of synchrotron and XFEL beamline optics.

angle metrology↗

Neutron source reconstruction using a generalized expectation–maximization algorithm on one-dimensional neutron images from the Z facility

Magnetized Liner Inertial Fusion experiments have been performed at the Z facility at Sandia National Laboratories. These experiments use deuterium fuel, which produces 2.45 MeV neutrons on reaching thermonuclear conditions. To study the spatial structure of neutron production, the one-dimensional imager of neutrons diagnostic was fielded to record axial resolved neutron images. In this diagnostic, neutrons passing through a rolled edge aperture form an image on a CR-39-based solid state nuclear track detector. In this report we present a modified generalized expectation–maximization algorithm to reconstruct an axial neutron emission profile of the stagnated fusion plasma. We validate the approach by comparing the reconstructed neutron emission profile to an x-ray emission profile provided by a time-integrated pinhole camera.

47 OTHER INSTRUMENTATION↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FastrSHWFS Analysis

This code analyzes the reflection geometry of modified Shack-Hartmann Wavefront Sensor (SHWFS) masks, with a focus on the fastrSHWFS designs. It takes a height map of a reflective mask, divides it into sub apertures, removes the global focus term by referencing a central block, and fits local surface planes to each sub aperture. From these fits it computes reflection angles and propagates the corresponding rays downstream to determine spot positions and the overall reflected beam footprint as a function of distance. The implementation is parameterized in sub aperture size, number of sub apertures, focal length, and mask dimensions, so it can be adapted to different mask designs beyond the two current fastrSHWFS masks. The code: Converts mask bitmaps into physical height in microns and reconstructs a focus subtracted mask, divides the mask into a grid of sub apertures and assigns pixel and micron coordinates to each block, excludes user specified unused sub apertures from the analysis, fits a plane to each sub aperture to obtain local surface normals, propagates reflected rays to a range of z positions to compute ray spots and the full reflected beam width, computes the effective mask tilt angle with respect to the incoming beam as a function of propagation distance, and provides helper routines for plotting the grid over the mask and for visualizing the beam geometry. These tools are intended for iterating on fastrSHWFS mask designs and for planning downstream optical layouts, for example choosing lens positions and apertures that capture the reflected beam given known focal plane distances and beam widths.

Gerard, BenjaminL [Lawrence Livermore National Lab↗

Probing cosmic velocities with the pairwise kinematic Sunyaev-Zel’dovich signal in DESI Bright Galaxy Sample DR1 and ACT DR6

We present a measurement of the pairwise kinematic Sunyaev-Zel’dovich (kSZ) signal using the Dark Energy Spectroscopic Instrument (DESI) Bright Galaxy Sample (BGS) Data Release 1 (DR1) galaxy sample overlapping with the Atacama Cosmology Telescope (ACT) CMB temperature map. Our analysis makes use of 1.6 million galaxies with stellar masses log⁡ 𝑀 ⋆ /𝑀 ⊙ >10, and we explore measurements across a range of aperture sizes (2.1′ <𝜃 ap <3.5′) and stellar mass selections. This statistic directly probes the velocity field of the large-scale structure, a unique observable of cosmic dynamics and modified gravity. In particular, at low redshifts, this quantity is especially interesting, as deviations from General Relativity are expected to be largest. Notably, our result represents the highest-significance low-redshift (𝑧 ∼ 0.3) detection of the kSZ pairwise effect yet. In our most optimal configuration (𝜃 ap =3.3′, log⁡ 𝑀 ⋆ >11), we achieve a 5⁢𝜎 detection. Assuming that an estimate of the optical depth and galaxy bias of the sample exists via e.g., external observables, this measurement constrains the fundamental cosmological combination 𝐻 0 ⁡𝑓⁡𝜎$^2_8$. A key challenge is the degeneracy with the galaxy optical depth. We address this by combining CMB lensing, which allows us to infer the halo mass and galaxy population properties, with hydrodynamical simulation estimates of the mean optical depth, $\bar{𝜏}$ . We stress that this is a proof-of-concept analysis; with BGS DR2 data we expect to improve the statistical precision by roughly a factor of two, paving the way toward robust tests of modified gravity with kSZ-informed velocity-field measurements at low redshift.

Hadzhiyska, Boryana [Institute of Astronomy; Kavli↗

Ultrasound waveform tomography with spatial and edge regularization

Synthetic-aperture ultrasound tomography systems and methods using scanning arrays and algorithms configured to simultaneously acquire ultrasound transmission and reflection data, and process the data for improved ultrasound tomography imaging, wherein the tomography imaging comprises total-variation regularization, or a modified total variation regularization, particularly with edge-guided or spatially variant regularization.

Huang, Lianjie↗