Search NASASearch

SEARCH · Search NASA

Results for “modulation transfer function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

LANDSAT-4 Thematic Mapper Modulation Transfer Function (MTF) evaluation

The Modulation Transfer Function (MTF) for thematic mapping (TM) bands 3, 4, 5 and 7 is reliably estimated with the San Mateo Bridge target in the 12/31/82 scene. These results are to be compared with those from the 8/12/83 scene. Bands 1, 2 and 6 are to be analyzed with a different target possessing greater contrast. This may be possible with the underflight data comparison currently underway. The registration of this data to the TM image of 8/12/83 for a region arround the Stockton sewage pond east of San Francisco has begun. This particular approach has the advantage that the full two-dimensional MFT will be measured instead of the MFT in only one azimuth as reported.

Schowengerdt, R.

Modulation Transfer Function of Infrared Focal Plane Arrays

Modulation transfer function (MTF) is the ability of an imaging system to faithfully image a given object. The MTF of an imaging system quantifies the ability of the system to resolve or transfer spatial frequencies. In this presentation we will discuss the detail MTF measurements of 1024x1024 pixels mid -wavelength and long- wavelength quantum well infrared photodetector, and 320x256 pixels long- wavelength InAs/GaSb superlattice infrared focal plane arrays (FPAs). Long wavelength Complementary Barrier Infrared Detector (CBIRD) based on InAs/GaSb superlattice material is hybridized to recently designed and fabricated 320x256 pixel format ROIC. The n-type CBIRD was characterized in terms of performance and thermal stability. The experimentally measured NE delta T of the 8.8 micron cutoff n-CBIRD FPA was 18.6 mK with 300 K background and f/2 cold stop at 78K FPA operating temperature. The horizontal and vertical MTFs of this pixel fully delineated CBIRD FPA at Nyquist frequency are 49% and 52%, respectively.

long-wave infrared

Measurements of ocean wave spectra and modulation transfer function with the airborne two frequency scatterometer

The directional spectrum and the microwave modulation transfer function of ocean waves can be measured with the airborne two frequency scatterometer technique. Similar to tower based observations, the aircraft measurements of the Modulation Transfer Function (MTF) show that it is strongly affected by both wind speed and sea state. Also detected are small differences in the magnitudes of the MTF between downwind and upwind radar look directions, and variations with ocean wavenumber. The MTF inferred from the two frequency radar is larger than that measured using single frequency, wave orbital velocity techniques such as tower based radars or ROWS measurements from low altitude aircraft. Possible reasons for this are discussed. The ability to measure the ocean directional spectrum with the two frequency scatterometer, with supporting MTF data, is demonstrated.

Weissman, D. E.

Measurements of ocean wave spectra and modulation transfer function with the airborne two-frequency scatterometer

The directional spectrum and the microwave modulation transfer function of ocean waves can be measured with the airborne two frequency scatterometer technique. Similar to tower based observations, the aircraft measurements of the Modulation Transfer Function (MTF) show that it is strongly affected by both wind speed and sea state. Also detected are small differences in the magnitudes of the MTF between downwind and upwind radar look directions, and variations with ocean wavenumber. The MTF inferred from the two frequency radar is larger than that measured using single frequency, wave orbital velocity techniques such as tower based radars or ROWS measurements from low altitude aircraft. Possible reasons for this are discussed. The ability to measure the ocean directional spectrum with the two frequency scatterometer, with supporting MTF data, is demonstrated.

Weissman, D. E.

Modulation transfer function measurement technique for small-pixel detectors

A modulation transfer function (MTF) measurement technique suitable for large-format, small-pixel detector characterization has been investigated. A volume interference grating is used as a test image instead of the bar or sine wave target images normally used. This technique permits a high-contrast, large-area, sinusoidal intensity distribution to illuminate the device being tested, avoiding the need to deconvolve raw data with imaging system characteristics. A high-confidence MTF result at spatial frequencies near 200 cycles/mm is obtained. We present results at several visible light wavelengths with a 6.8-micron-pixel CCD. Pixel response functions are derived from the MTF results.

Marchywka, Mike

Modulation Transfer Function (MTF) measurement techniques for lenses and linear detector arrays

Application is the determination of the Modulation Transfer Function (MTF) for linear detector arrays. A system set up requires knowledge of the MTF of the imaging lens. Procedure for this measurement is described for standard optical lab equipment. Given this information, various possible approaches to MTF measurement for linear arrays is described. The knife edge method is then described in detail.

Schnabel, J. J., Jr.

Parametric dependence of ocean wave-radar modulation transfer functions

Microwave techniques at X and L band were used to determine the dependence of ocean-wave radar modulation transfer functions (MTFs) on various environmental and radar parameters during the Marine Remote Sensing experiment of 1979 (MARSEN 79). These MIF are presented, as are coherence functions between the AM and FM parts of the backscattered microwave signal. It is shown that they both depend on several of these parameters. Besides confirming many of the properties of transfer functions reported by previous authors, indications are found that MTFs decrease with increasing angle between wave propagation and antenna-look directions but are essentially independent of small changes in air-sea temperature difference. However, coherence functions are much smaller when the antennas are pointed perpendicular to long waves. It is found that X band transfer functions measured with horizontally polarized microwave radiation have larger magnitudes than those obtained by using vertical polarization.

Plant, W. J.

On-Orbit Lunar Modulation Transfer Function Measurements for the Moderate Resolution Imaging Spectroradiometer

Spatial quality of an imaging sensor can be estimated by evaluating its modulation transfer function (MTF) from many different sources such as a sharp edge, a pulse target, or bar patterns with different spatial frequencies. These well-defined targets are frequently used for prelaunch laboratory tests, providing very reliable and accurate MTF measurements. A laboratory-quality edge input source was included in the spatial-mode operation of the Spectroradiometric Calibration Assembly (SRCA), which is one of the onboard calibrators of the Moderate Resolution Imaging Spectroradiometer (MODIS). Since not all imaging satellites have such an instrument, SRCA MTF estimations can be used as a reference for an on-orbit lunar MTF algorithm and results. In this paper, the prelaunch spatial quality characterization process from the Integrated Alignment Collimator and SRCA is briefly discussed. Based on prelaunch MTF calibration using the SRCA, a lunar MTF algorithm is developed and applied to the lifetime on-orbit Terra and Aqua MODIS lunar collections. In each lunar collection, multiple scan-directionMoon-to-background transition profiles are aligned by the subpixel edge locations from a parametric Fermi function fit. Corresponding accumulated edge profiles are filtered and interpolated to obtain the edge spread function (ESF). The MTF is calculated by applying a Fourier transformation on the line spread function through a simple differentiation of the ESF. The lifetime lunar MTF results are analyzed and filtered by a relationship with the Sun-Earth-MODIS angle. Finally, the filtered lunarMTF values are compared to the SRCA MTF results. This comparison provides the level of accuracy for on-orbit MTF estimations validated through prelaunch SRCA measurements. The lunar MTF values had larger uncertainty than the SRCA MTF results; however, the ratio mean of lunarMTF fit and SRCA MTF values is within 2% in the 250- and 500-m bands. Based on the MTF measurement uncertainty range, the suggested lunar MTF algorithm can be applied to any on-orbit imaging sensor with lunar calibration capability.

Choi, Taeyong

Imaging performance of annular apertures. III - Apodization and modulation transfer functions

Apodization functions with decreasing transmission and their opposite, functions with increasing transmission, are investigated for various central obstruction ratios. The resultant modulation transfer functions are presented for various transmission functions and central obstruction ratios. Conclusions applicable to the improvement of imaging performance are discussed.

Tschunko, H. F. A.

Modulation-transfer-function analysis for sampled image systems

Sampling generally causes the response of a digital imaging system to be locally shift-variant and not directly amenable to Modulation Transfer Function (MTF) analysis. However, this paper demonstrates that a meaningful system response can be calculated by averaging over an ensemble of point-source system inputs to yield an MTF which accounts for the combined effects of image formation, sampling, and image reconstruction. As an illustration, the MTF of the Landsat MSS system is analyzed to reveal an average effective instantaneous field of view which is significantly larger than the commonly accepted value, particularly in the along-track direction where undersampling contributes markedly to an MTF reduction and resultant increase in image blur.

Park, S. K.

Ocean wave-radar modulation transfer functions from the West Coast experiment

Short gravity-capillary waves, the equilibrium, or the steady state excitations of the ocean surface are modulated by longer ocean waves. These short waves are the predominant microwave scatterers on the ocean surface under many viewing conditions so that the modulation is readily measured with CW Doppler radar used as a two-scale wave probe. Modulation transfer functions (the ratio of the cross spectrum of the line-of-sight orbital speed and backscattered microwave power to the autospectrum of the line-of-sight orbital speed) were measured at 9.375 and 1.5 GHz (Bragg wavelengths of 2.3 and 13 cm) for winds up to 10 m/s and ocean wave periods from 2-18 s. The measurements were compared with the relaxation-time model; the principal result is that a source of modulation other than straining by the horizontal component of orbital speed, possibly the wave-induced airflow, is responsible for most of the modulation by waves of typical ocean wave period (10 s). The modulations are large; for unit coherence, spectra of radar images of deep-water waves should be proportional to the quotient of the slope spectra of the ocean waves by the ocean wave frequency.

Wright, J. W.

Quickbird Satellite in-orbit Modulation Transfer Function (MTF) Measurement Using Edge, Pulse and Impulse Methods for Summer 2003

The spatial characteristics of an imaging system cannot be expressed by a single number or simple statement. However, the Modulation Transfer Function (MTF) is one approach to measure the spatial quality of an imaging system. Basically, MTF is the normalized spatial frequency response of an imaging system. The frequency response of the system can be evaluated by applying an impulse input. The resulting impulse response is termed the Point Spread function (PSF). This function is a measure of the amount of blurring present in the imaging system and is itself a useful measure of spatial quality. An underlying assumption is that the imaging system is linear and shift-independent. The Fourier transform of the PSF is called the Optical Transfer Function (OTF) and the normalized magnitude of the OTF is the MTF. In addition to using an impulse input, a knife-edge in technique has also been used in this project. The sharp edge exercises an imaging system at all spatial frequencies. The profile of an edge response from an imaging system is called an Edge Spread Function (ESF). Differentiation of the ESF results in a one-dimensional version of the Point Spread Function (PSF). Finally, MTF can be calculated through use of Fourier transform of the PSF as stated previously. Every image includes noise in some degree which makes MTF of PSF estimation more difficult. To avoid the noise effects, many MTF estimation approaches use smooth numerical models. Historically, Gaussian models and Fermi functions were applied to reduce the random noise in the output profiles. The pulse-input method was used to measure the MTF of the Landsat Thematic Mapper (TM) using 8th order even functions over the San Mateo Bridge in San Francisco, California. Because the bridge width was smaller than the 30-meter ground sample distance (GSD) of the TM, the Nyquist frequency was located before the first zero-crossing point of the sinc function from the Fourier transformation of the bridge pulse. To avoid the zero-crossing points in the frequency domain from a pulse, the pulse width should be less than the width of two pixels (or 2 GSD's), but the short extent of the pulse results in a poor signal-to-noise ratio. Similarly, for a high-resolution satellite imaging system such as Quickbird, the input pulse width was critical because of the zero crossing points and noise present in the background area. It is important, therefore, that the width of the input pulse be appropriately sized. Finally, the MTF was calculated by taking ratio between Fourier transform of output and Fourier transform of input. Regardless of whether the edge, pulse and impulse target method is used, the orientation of the targets is critical in order to obtain uniformly spaced sub-pixel data points. When the orientation is incorrect, sample data points tend to be located in clusters that result in poor reconstruction of the edge or pulse profiles. Thus, a compromise orientation must be selected so that all spectral bands can be accommodated. This report continues by outlining the objectives in Section 2, procedures followed in Section 3, descriptions of the field campaigns in Section 4, results in Section 5, and a brief summary in Section 6.

Helder, Dennis

On-orbit Modulation Transfer Function (MTF) Measurements for IKONOS and QuickBird

Point Spread Function is a method of evaluation the spatial resolution of an imaging system. It is also a measure of the spread of a single point of light. Modulation Transfer Function (MTF) is a measure of the spatial frequency response. It is often calculated from th point spread function (PSF). System response at the Nyquist frequency (or 0.5 cycle/pixel) is often used as a figure of merit

Helde, Dennis

LANDSAT-4 thematic mapper Modulation Transfer Function (MTF) evaluation

A power spectrum (PS) analysis technique was used to compare thematic mapper (TM) A and P-tape data for a Washington, DC scene in two orthogonal directions, along scan and along track. The resulting effective modulation transfer functions (MTF) between the A and P data are repeatable from area to area and consistent with theoretical expectations. The average x-direction (along scan) MTF calculated with the PS technique is compared to the MTF of the cubic convolution resampling function used to create P data from A data. The two curves are nearly identical, indicating that the major factor affecting the image quality of P data relative to A data is the cubic convolution resampling.

Schowengerdt, R.

Pre-Launch Analysis and Test of the Ocean Color Instrument Modulation Transfer Function

Launched in February 2024, the Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. The Ocean Color Instrument (OCI) is the primary instrument supporting PACE by collecting accurate radiometric data of the Earth by observing the top of atmosphere reflectance and is a combination hyperspectral (ultra-violet to near infrared) / multiband imager (shortwave infrared). An important aspect of the radiometry is the ability of OCI to resolve contrast from scene to scene to achieve data accuracy requirements. This paper reviews the analysis that was performed to verify the modulation transfer function requirement levied against the instrument and presents the supportive test data collected during pre-launch instrument testing to supplement the analysis. The requirements levied against OCI drove to a 1.2 km2 ground resolution leading to a Nyquist period of 2.4 km (0.417 cycles / km). The analysis is comprehensive with incorporation of as many contributors as practical to provide the clearest possible picture of the margin against requirements. The analysis provided input for additional design trade studies and insight into the aspects of the design that required the most attention during the implementation phase. We describe four separate MTF contributor networks based on the instrument design and mutual exclusivity of contributing factors. The various networks represent the hyperspectral and multiband detection systems separately as well as the along track and cross track imaging dimensions. Ground-test was performed against the MTF primary contributors and the results were used to validate the analysis as will be presented here.

OCI

Pre-Launch Analysis and Test of the Ocean Color Instrument Modulation Transfer Function

Launched in February 2024, the Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. The Ocean Color Instrument (OCI) is the primary instrument supporting PACE by collecting accurate radiometric data of the Earth by observing the top of atmosphere reflectance and is a combination hyperspectral (ultra-violet to near infrared) / multiband imager (shortwave infrared). An important aspect of the radiometry is the ability of OCI to resolve contrast from scene to scene to achieve data accuracy requirements. This paper reviews the analysis that was performed to verify the modulation transfer function requirement levied against the instrument and presents the supportive test data collected during pre-launch instrument testing to supplement the analysis. The requirements levied against OCI drove to a 1.2 km2 ground resolution leading to a Nyquist period of 2.4 km (0.417 cycles / km). The analysis is comprehensive with incorporation of as many contributors as practical to provide the clearest possible picture of the margin against requirements. The analysis provided input for additional design trade studies and insight into the aspects of the design that required the most attention during the implementation phase. We describe four separate MTF contributor networks based on the instrument design and mutual exclusivity of contributing factors. The various networks represent the hyperspectral and multiband detection systems separately as well as the along track and cross track imaging dimensions. Ground-test was performed against the MTF primary contributors and the results were used to validate the analysis as will be presented here.

OCI