Search NASA⌕ Search

SEARCH · Search NASA

Results for “module cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Passive thermosyphon solar heating and cooling module with supplementary heating

A collection of three quarterly reports from Sigma Research, Inc., covering progress and status from January through September 1977 are presented. Three heat exchangers are developed for use in a solar heating and cooling system for installation into single-family dwellings. Each exchanger consists of one heating and cooling module and one submerged electric water heating element.

Source record↗

Development of a Turn Key Cryogenic Cooling Module for Space Flight Based on a Commercial Cryocooler

Commercial cryocoolers have significant price and lead time advantages over coolers built exclusively for the space market, but there are many challenges that must be overcome before using a COTS cooler for flight. The initial cost advantage is significantly narrowed by the cost of adapting the COTS cooler for flight. JPL is developing a “turnkey” cryogenic cooling solution based on a commercial cryocooler with the intention that it can become a standard product. The goal is to develop a complete, fully redundant cryogenic cooling solution based on the Thales 9310. The system includes the cooler, brackets to provide mounting and cooling, supporting structures, vibration isolation, thermal straps, thermal switches, and drive electronics. This paper discusses qualification of the various components for flight, including launch vibration and thermal performance testing, as well as a full up testing of the completed assembly.

Ramsey, Perry G.↗

Development of a Turn Key Cryogenic Cooling Module for Space Flight Based on a Commercial Cryocooler

Commercial cryocoolers have significant price and lead time advantages over coolers built exclusively for the space market, but there are many challenges that must be overcome before using a COTS cooler for flight. The initial cost advantage is significantly narrowed by the cost of adapting the COTS cooler for flight. JPL is developing a “turn key” cryogenic cooling solution based on a commercial cryocooler with the intention that it can become a standard product. The goal is to develop a complete, fully redundant cryogenic cooling solution based on the Thales 9310. The system includes the cooler, brackets to provide mounting and cooling, supporting structures, vibration isolation, thermal straps, thermal switches, and drive electronics. This paper discusses qualification of the various components for flight, including launch vibration and thermal performance testing, as well as a full up testing of the completed assembly.

Ramsey, Perry G.↗

Real-Time Closed Loop Modulated Turbine Cooling

It has been noted by industry that in addition to dramatic variations of temperature over a given blade surface, blade-to-blade variations also exist despite identical design. These variations result from manufacturing variations, uneven wear and deposition over the life of the part as well as limitations in the uniformity of coolant distribution in the baseline cooling design. It is proposed to combine recent advances in optical sensing, actuation, and film cooling concepts to develop a workable active, closed-loop modulated turbine cooling system to improve by 10 to 20 the turbine thermal state over the flight mission, to improve engine life and to dramatically reduce turbine cooling air usage and aircraft fuel burn. A reduction in oxides of nitrogen (NOx) can also be achieved by using the excess coolant to improve mixing in the combustor especially for rotorcraft engines. Recent patents filed by industry and universities relate to modulating endwall cooling using valves. These schemes are complex, add weight and are limited to the endwalls. The novelty of the proposed approach is twofold 1) Fluidic diverters that have no moving parts are used to modulate cooling and can operate under a wide range of conditions and environments. 2) Real-time optical sensing to map the thermal state of the turbine has never been attempted in realistic engine conditions.

turbines↗

Thermal-Fluid Analysis of a Liquid-Cooled Battery Module for Electrified Aircraft

The development of safe, energy-dense batteries is critical to advancing hybrid electric and fully electrified aircraft propulsion. Achieving this capability requires a thermal management system that can maintain battery performance and safety under demanding operational conditions. The objective of this project is to support the maturation of next-generation lithium-ion batteries for electrified aircraft by conducting performance testing on integrated battery modules, specifically a 2-cell series configuration module housed within an aluminum enclosure. Designed to operate at a nominal 7.2 V with discharge rates up to 2.5C, the module will eventually be used to power an electric motor and DC-DC converter, generating substantial thermal loads that must be effectively managed to increase the usable energy and power density of electrified aircraft. To address these thermal challenges, this study presents the development and thermal-fluid analysis of a liquid-cooled thermal management system. While the full aircraft architecture utilizes an eight-string configuration, the present work evaluates a representative single-string water coolant loop to characterize baseline performance. The active cooling loop circulates water through a reservoir, pump, the battery module, and a variable area flow meter. Key performance metrics including component-level temperatures, mass flow rates, and pressure drops are quantified across the loop. Across discharge rates ranging from 0.5C to 2.5C, the active thermal loop consistently and effectively removed heat from the module, validating the design approach and confirming readiness for further development. The validated thermal performance indicates a path toward scalable battery modules that could enable energy and power dense systems for hybrid electric aircraft.

Electrified Aircraft↗

Preliminary design package for maxi-therm heat exchanger module

Heat exchangers were developed for use in a solar heating and cooling system installed in a single family dwelling. Each of the three exchangers consisted of a heating and cooling module and a submersed electric water heating element. Information necessary to evaluate the preliminary design of the heat exchanger is presented in terms of the development and verification plans, performance specifications, installation and maintenance, and hazard analysis.

Source record↗

Thermal and other tests of photovoltaic modules performed in natural sunlight

The nominal operating cell temperature (NOCT), an effective way to characterize the thermal performance of a photovoltaic module in natural sunlight, is developed. NOCT measurements for more than twenty different modules are presented. Changes in NOCT reflect changes in module design, residential roof mounting, and dirt accumulation. Other test results show that electrical performance is improved by cooling modules with water and by use of a phase change wax. Electrical degradation resulting from the marriage of photovoltaic and solar water heating modules is demonstrated. Cost-effectiveness of each of these techniques is evaluated.

Stultz, J. W.↗

Industrial and biomedical use of aerospace personal cooling garments

Liquid-cooled garments (LCG) have been developed which utilize liquid-cooled modules rather than the network of tygon tubing typical of Apollo LCG's. The ultra-thin, heat-sealed, polyurethane modules are situated over the body to cover 50 percent of the body surface area with special emphasis on the 'working' muscles and the head-neck area. These garments are being designed specifically for industrial and biomedical uses, such as: a head-neck cooling system which is being tested for race-car drivers, tractor drivers, truck drivers, or a head-neck cooling system tested for the reduction of the scalp hair loss which normally accompanies cancer treatments. A combined head-neck and thorax unit is being developed for use during mine distaster rescue operations, and for other hazardous hot applications. Finally applications for head-neck and partitional cooling are anticipated for military pilots, tank drivers, and heavy equipment operations.

Williams, B. A.↗

External Peltier Cooler For Low-Noise Amplifier

Inexpensive Peltier-effect cooling module made of few commercially available parts used to reduce thermal noise in microwave amplifier. Retrofitted to almost any microwave low-noise amplifier or receiver preamplifier used in communication, telemetry, or radar. Includes copper or aluminum cold plate held tightly against unit to be cooled by strap-type worm-gear clamps.

Soper, Terry A.↗

Air modulation apparatus

An air modulation apparatus, such as for use in modulating cooling air to the turbine section of a gas turbine engine is described. The apparatus includes valve means disposed around an annular conduit, such as a nozzle, in the engine cooling air circuit. The valve means, when in a closed position, blocks a portion of the conduit, and thus reduces the amount and increases the velocity of cooling air flowing through the nozzle. The apparatus also includes actuation means, which can operate in response to predetermined engine conditions, for enabling opening and closing of the valve means.

Lenahan, D. T.↗

Controllable Multi-Functional Heat Exchanger for Space Applications

Team Spacering will design SpaceRing, a cooling and waste heat recycling system that addresses NASA’s interest for a cooling and power-generating unit in its prototype deep space habitat[1]. The merits of this system are as follows: - Controllable cooling is critical in maintaining a habitable environment and in the functionality of life support systems, powering electronics and other devices in a spacecraft. - Power is expensive to produce in a space environment. Converting wasted thermal energy into electricity will save energy and money for the space station. Space habitation is a highly complex endeavor. Consequently, the SpaceRing must adhere to additional constraints, which include: - Lack of natural fluid or gas convection due to micro-gravity environment - Limited range for heat source and cold sink temperature - Subject to high fluctuations of incoming thermal energy - Minimal weight due to the high cost of transporting items into space After consulting with NASA and experts in thermal studies, several design objectives were identified and are listed below in order of importance: - High cooling capacity - Reliable safety control and alert system - Maximization of energy generation from wasted heat - Optimization of cooling capability and power generation - Long operational life and minimization of maintenance In space, conventional cooling systems utilize passive heat pipe systems for small-scale heat rejection and pumped pipes with heat exchangers for large-scale heat rejection. Thermal power generation in space is mainly achieved by using thermoelectric material that produces electric energy from temperature differentials. We propose a design that combines cooling and thermoelectric power generation. Using a hot pipe connected to a heat source, a cold pipe connected to a radiator, a heat exchanger in contact with both pipes, and a pump in each pipe to move the fluid, we make an active cooling system. The thermoelectric material is inserted in the heat exchanger between the hot and cold pipes to extract energy from the maximum temperature difference coming from the two pipes. It also provides controllable cooling capacity through the use of the thermoelectric material as cooling modules. We have tested our system under target heat source and sink conditions and measured the temperatures and flow rates. Our preliminary results are promising, demonstrating the output of 25 Watts of power on average. We are in the process of running control tests to compare the heat transfer performance without the thermoelectric generators, which is vital in determining whether or not the generators introduce an unacceptable amount of thermal resistance. While some control tests have been run already, the results have been noisy. We have modified our testing environment and data acquisition methods to allow for simple comparison between the control test results and thermoelectric performance results. Lastly, we have modified the heat exchanger design slightly to include acrylic baffles. This will allow the heat to flow through the heat exchanger more efficiently. We have presented our preliminary results to NASA and will deliver the final product by the end of May 2014.

Lee Xiong↗

High density electronic packaging module with improved cooling assembly

Cold plate increases heat transfer within high density electronic module. Tapered pins improve heat transfer process by providing larger surface pressure with increased planar area. Cooling technique increases thermal contact where planar area is limited, interface pressure increases the heat transfer coefficient.

Martin, J. H.↗

Rotational modulation in IUE spectra of cool dwarf chromospheres: Data analysis and period search techniques

The IUE spectra of bright F-K dwarfs were used to investigate rotational modulation in chromospheric and transition region emission lines, with Stellingwerf's phase dispersion minimization (PDM) technique as the basis of time series analysis. Sampling-related aliases are found to dominate the PDM spectra in these sparsely sampled, irregularly spaced time series. The star chosen to illustrate the techniques is epsilon Eridani, a young, chromospherically active K2 dwarf. Strong indications of a rotation period close to 2.8 days in epsilon Eridani from 2 seasons of observations, with evidence for the persistence in longitude of the active area(s) over several hundred rotation cycles are found.

Altner, B.↗

Rotational modulation in IUE spectra of cool dwarf chromospheres. I - Data analysis and period search techniques

Time-sequenced IUE spectra of a number of a bright F-K dwarfs have been used to investigate rotational modulation in several important chromospheric and transition emission lines. Stellingwerf's phase dispersion minimization (PDM) technique forms the basis of this time-series analysis of these sparsely sampled, irregularly spaced observational sequences, which consist of no more than 13 spectra in any one season. In such highly sample-limited time series, the resultant PDM spectrum is greatly complicated by overlapping alias orders which invariably produce strong interference effects, but the deliberately irregular sampling has proven of value in the development of techniques to identify the intrinsic stellar flux modulation period. Two stars are selected to illustrate these new techniques in detail.

Hallam, K. L.↗

Thermal and other tests of photovoltaic modules performed in natural sunlight

The bulk of the testing was the characterization of twenty-nine modules according to their nominal operating cell temperature (NOCT) and the effect on NOCT of changes in module design, various residential roof mounting configurations, and dirt accumulation. Other tests, often performed parallel with the NOCT measurements, evaluated the improvement in electrical performance by cooling the modules with water and by channeling the waste heat into a phase change material (wax). Electrical degradation resulting from the natural marriage of photovoltaic and solar water heating modules was also demonstrated. Cost effectiveness of each of these techniques are evaluated in light of the LSA cost goal of $0.50 per watt.

Stultz, J. W.↗