Search NASA⌕ Search

SEARCH · Search NASA

Results for “moisture buffering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Field measurement of moisture-buffering model inputs for residential buildings

Moisture adsorption and desorption in building materials impact indoor humidity. This effect should be included in building-energy simulations, particularly when humidity is being investigated or controlled. Several models can calculate this moisture-buffering effect, but accurate ones require model inputs that are not always known to the user of the building-energy simulation. This research developed an empirical method to extract whole-house model inputs for the effective moisture penetration depth (EMPD) model. The experimental approach was to subject the materials in the house to a square-wave relative-humidity profile, measure all of the moisture-transfer terms (e.g., infiltration, air-conditioner condensate), and calculate the only unmeasured term—the moisture sorption into the materials. We validated this method with laboratory measurements, which we used to measure the EMPD model inputs of two houses. After deriving these inputs, we measured the humidity of the same houses during tests with realistic latent and sensible loads and demonstrated the accuracy of this approach. Furthermore, these results show that the EMPD model, when given reasonable inputs, is an accurate moisture-buffering model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Whole-House Field Tests to Empirically Derive Moisture Buffering Model Inputs

Building energy simulations can be used to predict a building's interior conditions, along with the energy use associated with keeping these conditions comfortable. These models simulate the loads on the building (e.g., internal gains, envelope heat transfer), determine the operation of the space conditioning equipment, and then calculate the building's temperature and humidity throughout the year. The indoor temperature and humidity are affected not only by the loads and the space conditioning equipment, but also by the capacitance of the building materials, which buffer changes in temperature and humidity. This research developed an empirical method to extract whole-house model inputs for use with a more accurate moisture capacitance model (the effective moisture penetration depth model). The experimental approach was to subject the materials in the house to a square-wave relative humidity profile, measure all of the moisture transfer terms (e.g., infiltration, air conditioner condensate) and calculate the only unmeasured term: the moisture absorption into the materials. After validating the method with laboratory measurements, we performed the tests in a field house. A least-squares fit of an analytical solution to the measured moisture absorption curves was used to determine the three independent model parameters representing the moisture buffering potential of this house and its furnishings. Follow on tests with realistic latent and sensible loads showed good agreement with the derived parameters, especially compared to the commonly-used effective capacitance approach. These results show that the EMPD model, once the inputs are known, is an accurate moisture buffering model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Whole-House Field Tests to Empirically Derive Moisture Buffering Model Inputs

Building energy simulations can be used to predict a building's interior conditions, along with the energy use associated with keeping these conditions comfortable. These models simulate the loads on the building (e.g., internal gains, envelope heat transfer), determine the operation of the space conditioning equipment, and then calculate the building's temperature and humidity throughout the year. The indoor temperature and humidity are affected not only by the loads and the space conditioning equipment, but also by the capacitance of the building materials, which buffer changes in temperature and humidity. This research developed an empirical method to extract whole-house model inputs for use with a more accurate moisture capacitance model (the effective moisture penetration depth model). The experimental approach was to subject the materials in the house to a square-wave relative humidity profile, measure all of the moisture transfer terms (e.g., infiltration, air conditioner condensate) and calculate the only unmeasured term: the moisture absorption into the materials. After validating the method with laboratory measurements, we performed the tests in a field house. A least-squares fit of an analytical solution to the measured moisture absorption curves was used to determine the three independent model parameters representing the moisture buffering potential of this house and its furnishings. Follow on tests with realistic latent and sensible loads showed good agreement with the derived parameters, especially compared to the commonly-used effective capacitance approach. These results show that the EMPD model, once the inputs are known, is an accurate moisture buffering model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Effective Moisture Penetration Depth Model for Estimating Moisture Buffering in Buildings

This study examines the effective moisture penetration depth (EMPD) model, and its suitability for building simulations. The EMPD model is a compromise between the simple, inaccurate effective capacitance approach and the complex, yet accurate, finite-difference approach. Two formulations of the EMPD model were examined, including the model used in the EnergyPlus building simulation software. An error in the EMPD model we uncovered was fixed with the release of EnergyPlus version 7.2, and the EMPD model in earlier versions of EnergyPlus should not be used.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Effective Moisture Penetration Depth Model for Estimating Moisture Buffering in Buildings

This study examines the effective moisture penetration depth (EMPD) model, and its suitability for building simulations. The EMPD model is a compromise between the simple, inaccurate effective capacitance approach and the complex, yet accurate, finite-difference approach. Two formulations of the EMPD model were examined, including the model used in the EnergyPlus building simulation software. An error in the EMPD model we uncovered was fixed with the release of EnergyPlus version 7.2, and the EMPD model in earlier versions of EnergyPlus should not be used.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Soil Moisture Buffers the Impact of Precipitation Variability on Ecosystem Productivity

Water availability governs ecosystem productivity, yet estimates of vegetation sensitivity to water can differ greatly depending on whether the sensitivity is examined spatially or temporally. In particular, the spatial sensitivity is often reported to be much stronger than temporal sensitivities, leading to highly uncertain projections of ecosystem responses to future climate change when using space-for-time substitution. The large difference between spatial and temporal sensitivities remains unexplained. Prior research, however, primarily relied on precipitation as the water availability proxy, whereas vegetation responds to soil moisture. Here, we combined satellite estimates of vegetation productivity with soil moisture data across water-limited ecosystems of the continental United States (CONUS) to identify a convergent sensitivity of productivity to water availability. Using precipitation, we show that temporal sensitivity is 66% lower than spatial sensitivity overall. Our analysis identified the cause of the difference to be primarily driven by the seasonal variability of water availability, rooting depth, and soil properties. When using soil moisture instead of precipitation, we observed widespread convergence in the spatial and temporal sensitivities—that is, the two sensitivities became much more similar in magnitude across all water-limited ecosystems within CONUS. These results show that overlooking soil hydrology can inflate perceived discrepancies between spatial and temporal vegetation sensitivities, leading to biased projections of ecosystem dynamics under future hydro-climatic change.

Wang, Huiqi [University of California, Berkeley, C↗

Effective moisture penetration depth model for residential buildings: Sensitivity analysis and guidance on model inputs

Moisture buffering of building materials has a significant impact on the building's indoor humidity, and building energy simulations need to model this buffering to accurately predict the humidity. Researchers requiring a simple moisture-buffering approach typically rely on the effective-capacitance model, which has been shown to be a poor predictor of actual indoor humidity. This paper describes an alternative two-layer effective moisture penetration depth (EMPD) model and its inputs. While this model has been used previously, there is a need to understand the sensitivity of this model to uncertain inputs. In this paper, we use the moisture-adsorbent materials exposed to the interior air: drywall, wood, and carpet. We use a global sensitivity analysis to determine which inputs are most influential and how the model's prediction capability degrades due to uncertainty in these inputs. We then compare the model's humidity prediction with measured data from five houses, which shows that this model, and a set of simple inputs, can give reasonable prediction of the indoor humidity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity of occupant comfort models to humidity and their effect on cooling energy use

Residential building energy consumption in the United States has decreased steadily during the last several decades largely because of advances in building codes as well as voluntary efficiency and labeling programs, which have resulted in the reduction in building sensible loads. Building latent loads have not decreased by the same amount, and field and analytical research studies have concluded that high-efficiency, low-load homes often have elevated indoor humidity levels, possibly leading to occupant discomfort. There are discrepancies in the literature on occupant comfort as it relates to indoor humidity and recommended upper humidity limits. The choice of humidity limit could potentially change results and conclusions on the energy impacts of a new air conditioner or dehumidifier technology, changing ventilation rates, or an improved building envelope. In this study, we use building simulations to explore the impact of humidity control on cooling energy use in efficient residential buildings for different humidity limits. We look at limits based on humidity ratio (or dew point temperature), wet-bulb temperature, relative humidity, and constant slope lines based on the popular comfort models of both Fanger and Gagge. We quantify the additional energy use required to control humidity below these limits. We look at the sensitivity of the results to different temperature and humidity set points, occupant internal gains, moisture buffering levels, evaporator airflow rates, and dehumidifier energy factors. High-efficiency home predicted energy savings are more sensitive to the assumed humidity limit and cooling and dehumidification set points than the other parameters investigated in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of occupant behavior and air-conditioner controls on humidity in typical and high-efficiency homes

Increasing insulation levels and improved windows are reducing sensible cooling loads in high-efficiency homes. This trend raises concerns that the resulting shift in the balance of sensible and latent cooling loads may result in higher indoor humidity, occupant discomfort, and stunted adoption of high-efficiency homes. This study utilizes established moisture-buffering and air-conditioner latent degradation models in conjunction with an approach to stochastically model internal gains. Building loads and indoor humidity levels are compared for simulations of typical new construction homes and high-efficiency homes in 10 US cities. The sensitivity of indoor humidity to changes in cooling set point, air-conditioner capacity, and blower control parameters are evaluated. The results show that high-efficiency homes in humid climates have cooling loads with a higher fraction of latent loads than the typical new construction home, resulting in higher indoor humidity. Reducing the cooling set point is the easiest method to reduce indoor humidity, but it is not energy efficient, and overcooling may lead to occupant discomfort. Eliminating the blower operation at the end of cooling cycles and reducing the cooling airflow rate also reduce indoor humidity and with a smaller impact on energy use and comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Indoor Climate and Moisture Durability Performances of Houses with Unvented Attic Roof Constructions in a Mixed-Humid Climate

A sealed or unvented attic is an energy-efficient envelope component that can reduce the amount of energy a house consumes for space conditioning if the air handler and/or ducts are located in the attic. The attic is typically sealed by using spray foam on the underside of the roof deck and covering the soffit, ridge and gable vents to minimize air leakage from the attic to the outside. This approach can save up to 10% in space-conditioning energy when ducts are located in the attic (DOE 2013). Past research done by ORNL and Florida Solar Energy Center suggests that in more hot, humid climates, an unvented attic could potentially create a more humid, uncomfortable living environment than a vented attic (Colon 2011, Boudreaux, Pallin et al. 2013). Research showed that controlling the higher indoor humidity could reduce the energy savings from the sealed, unvented attic, which in turn would decrease the energy savings payback. Research also showed that the roof assembly (5.5 inches of open-cell foam, 1inch of closed-cell foam, OSB, felt paper, and asphalt shingles) stored moisture, thus acting as a moisture buffer. During the fall and winter, the roof assembly stored moisture and during the spring and summer it released moisture. This phenomenon is not seen in a vented attic, in which the air exchange rate to the outside is greater and, in the winter, helps to dehumidify the attic air. It was also seen that in a vented attic, the direction of water vapor diffusion is on average from the attic to the interior of the house. Air leakage from the attic to the interior also occurs during more of the year in a house with an unvented attic than in one with a vented attic. These discoveries show that the moisture dynamics in a house with an unvented attic are much different from those in a house with a vented attic. This study reports on a series of computer model investigations completed to determine the key variables impacting indoor comfort and the durability of roof assemblies against moisture. The key variables investigated were the leakage area from the attic to the outside, leakage area from the attic to the interior, leakage area from the interior to the outside, supply duct leakage in the attic, and interior moisture generation. These investigations are described in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of contaminant storage on indoor air quality: Model development

A first-order, lumped capacitance model is used to describe the buffering of airborne chemical species by building materials and furnishings in the indoor environment. The model is applied to describe the interaction between formaldehyde in building materials and the concentration of the species in the indoor air. Storage buffering can decrease the effect of ventilation on the indoor concentration, compared to the inverse dependence of indoor concentration on the air exchange rate that is consistent with a constant emission rate source. If the exposure time of an occupant is long relative to the time scale of depletion of the compound from the storage medium, however, the total exposure will depend inversely on the air exchange rate. This lumped capacitance model is also applied to moisture buffering in the indoor environment, which occurs over much shorter depletion timescales of the order of days. This model provides a framework to interpret the impact of storage buffering on time-varying concentrations of chemical species and resulting occupant exposure. Pseudo-steady state behavior is validated using field measurements. Model behavior over longer times is consistent with formaldehyde and moisture concentration measurements in previous studies.

54 ENVIRONMENTAL SCIENCES↗

Recent California tree mortality portends future increase in drought-driven forest die-off

Vegetation tolerance to drought depends on an array of site-specific environmental and plant physiological factors. This tolerance is poorly understood for many forest types despite its importance for predicting and managing vegetation stress. We analyzed the relationships between precipitation variability and forest die-off in California's Sierra Nevada and introduce a new measure of drought tolerance that emphasizes plant access to subsurface moisture buffers. We applied this metric to California's severe 2012-2015 drought, and show that it predicted the patterns of tree mortality. We then examined future climate scenarios, and found that the probability of droughts that lead to widespread die-off increases threefold by the end of the 21st century. Our analysis shows that tree mortality in the Sierra Nevada will likely accelerate in the coming decades and that forests in the Central and Northern Sierra Nevada that largely escaped mortality in 2012-2015 are vulnerable to die-off.

54 ENVIRONMENTAL SCIENCES↗

Active synthetic soil

A synthetic soil/fertilizer for horticultural application having all the agronutrients essential for plant growth is disclosed. The soil comprises a synthetic apatite fertilizer having sulfur, magnesium, and micronutrients dispersed in a calcium phosphate matrix, a zeolite cation exchange medium saturated with a charge of potassium and nitrogen cations, and an optional pH buffer. Moisture dissolves the apatite and mobilizes the nutrient elements from the apatite matrix and the zeolite charge sites.

Ming, Douglas W.↗

Active synthetic soil

A synthetic soil/fertilizer for horticultural application having all the agronutrients essential for plant growth is disclosed. The soil comprises a synthetic apatite fertilizer having sulfur, magnesium and micronutrients dispersed in a calcium phosphate matrix, a zeolite cation exchange medium saturated with a charge of potassium and nitrogen cations, and an optional pH buffer. Moisture dissolves the apatite and mobilizes the nutrient elements from the apatite matrix and the zeolite charge sites.

Ming, Douglas W.↗

Moisture Modeling: Effective Moisture Penetration Depth Versus Effective Capacitance

This paper compares two moisture models in the context of residential whole-building simulations - the effective moisture penetration depth (EMPD) model and the effective capacitance (EC) model. Previous research has shown that the EMPD model provides a more physically realistic response to humidity-load fluctuations than the EC model. But it is unclear how the choice of moisture model affects overall conclusions informing building design and equipment selection. In this study, the models are evaluated based on their ability to predict relative humidity, predict energy use, and to select HVAC equipment. Whole building simulations indicate that the EC and EMPD models are not equivalent, and that combining the capacitance of the building materials with the indoor air capacitance in the EC model is the root cause of this discrepancy. It means that the EC model cannot dampen humidity loads of different frequencies. This study also showed that a simulation using a certain value of EC in one city can agree with the EMPD results, but that the same EC value in a different city may not agree with the EMPD results. However, the results showed that some conclusions drawn from simulations using the EMPD model and the EC model may often be the same, even if the results differ.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of occupant behavior on peak cooling and dehumidification loads in typical and high-efficiency homes

Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure, installing the ductwork in conditioned space, and improving the building's airtightness results in significant reductions in externally-driven sensible and latent cooling loads. As a building's efficiency is improved, occupant-related internal gains become a larger portion of the building sensible and latent loads. Additionally, internal gains are highly uncertain compared to other load components. In this study, we use a stochastic approach to simulate occupant-related internal gains and compare the internal gains to other sensible and latent heat sources in four house efficiency levels in 10 U.S. climates using whole-building energy simulation software. We compare the expected range in occupant-related internal gains to other building characteristics such as cooling set point, air infiltration rate, and mechanical ventilation rate. We show that in high-efficiency homes, sensible internal gains vary from less than 10% to greater than 40% of the building sensible load under peak total cooling conditions depending on climate and internal gain profile. Likewise, latent internal gains vary from less than 10% to more than 60% of the building latent load under peak total cooling and peak dehumidification conditions depending on climate and internal gain profile.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of an ERT‐Based Framework for Bentonite Buffers Monitoring From Laboratory Tests: 2. Quantitative Moisture Dynamics Estimation Model

Abstract The long‐term containment of high‐level radioactive waste in geological disposal repositories relies on Engineered Barrier Systems (EBS), with bentonite clay emerging as a candidate material due to its unique properties. Understanding moisture dynamics within bentonite buffers is crucial for EBS performance, as it directly influences the material's swelling capacity, thermal and hydraulic conductivity, mechanical properties, and long‐term evolution under complex thermal‐hydrological‐mechanical (THM) processes. This study develops an advanced Electrical Resistivity Tomography (ERT)‐based framework to quantitatively monitor moisture dynamics under THM conditions. Our framework extends the Waxman‐Smits model to incorporate the coupled effects of temperature, water content, fluid chemistry, and mechanical changes on bentonite's electrical properties. Utilizing HotBENT‐Lab data from our companion paper, which includes electrical conductivity, CT density, and thermocouple measurements, this study offers a novel methodological framework bridging different scales of the model. Our results show that the extended model can estimate water content from ERT data, capturing spatial and temporal variations in moisture distribution within bentonite columns. However, the model tends to overestimate water content compared to CT density‐derived measurements. We address this discrepancy by incorporating a simplified swelling effect model, which improves agreement between ERT and CT density‐based water content estimates. We also discuss model limitations, including simplified treatment of swelling and micropore effects, and propose a conceptual framework for transitioning from laboratory to field applications, addressing challenges such as parameter scalability, field validation methods, and integration of diverse data sources. This ERT‐based framework can potentially advance real‐world moisture monitoring of bentonite‐based EBS in nuclear waste repositories. Plain Language Summary Safely containing high‐level radioactive waste depends on barriers made from materials like bentonite clay, which is effective because it swells and seals in the waste. To ensure these barriers work well over time, it's important to understand how moisture moves through the clay. Our study developed a new method using ERT to monitor moisture levels in bentonite under conditions that mimic those in actual storage sites, including changes in temperature, water content, and mechanical stress. This study improved an existing model to better account for how these factors affect the clay, allowing us to create more accurate moisture maps. Initially, the proposed model overestimated the amount of water in the clay, but its accuracy was improved by factoring in how the clay swells when wet. This study also identified some limitations of the model and suggested ways to adapt it for use in real‐world waste storage sites. This new approach could lead to better monitoring and safety checks for nuclear waste storage systems, helping to ensure long‐term containment. Key Points This work develops an ERT‐based framework extending the Waxman‐Smits model to monitor bentonite moisture dynamics during coupled THM processes The extended model accurately estimates water content from Electrical Resistivity Tomography data, incorporating swelling effects to improve precision This work proposes a conceptual framework for transitioning from laboratory to field applications, advancing EBS monitoring in nuclear waste repositories

Chen, Hang↗