At least 19 records

Isotherm Model for Moisture-Controlled CO 2 Sorption

Moisture-controlled sorption of CO 2 , the basis for moisture-swing CO 2 capture from air, is a novel phenomenon observed in strong-base anion exchange materials. Prior research has shown that Langmuir isotherms provide an approximate fit to moisture-controlled CO 2 sorption isotherm data. However, this fit still lacks a governing equation derived from an analytic model. As such, in this paper we derive an analytic form for an isotherm equation from a bottom-up approach, starting with a fundamental theory for an alkali liquid. In the range of interest relevant to CO 2 capture from air, an isotherm equation for an alkali liquid reduces to a simple analytic form with a single parameter, $K_{\text{eq}}$. In the limit $K_{\text{eq}} \gg 1$, a 2nd order approximation simplifies to a Langmuir isotherm that, however, deviates from experimental data. The isotherm theory for an alkali liquid has been generalized to a strong-base anion exchange material. In a strong-base anion exchange material, water concentration inside a sorbent, [H 2 O], is not large enough to be regarded as constant, which allows us to extend $K_{\text{eq}}$ to $K_{\text{eq(AEM)eff}} = K_{\text{eq(AEM)}} \times$ [H 2 O]$^{–n}$ according to the law of mass action. The final isotherm formula has been validated by experimental data from the literature. For a moisture-controlled CO 2 sorbent, $K_{\text{eq(AEM)eff}}$ varies significantly with moisture content of the sorbent. Depending on moisture level, the observed $K_{\text{eq(AEM)eff}}$ in a specific sorbent ranges from a few times to a few thousand times the value of $K_{\text{eq}}$ of a 2 mol L –1 alkali liquid.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Kinetic Model for Moisture-Controlled CO 2 Sorption

The understanding of the sorption/desorption kinetics is essential for practical applications of moisture-controlled CO 2 sorption. We introduce an analytic model of the kinetics of moisture-controlled CO 2 sorption and its interpretation in two limiting cases. In one case, chemical reaction kinetics on pore surfaces dominates, in the other case, diffusive transport through the sorbent defines the kinetics. Here, we show that reaction kinetics, which is dominant in the first case, can be expressed as a linear combination of 1st and 2nd order kinetics in agreement with the static isotherm equation derived and validated in a previous paper. The interior transport kinetics can be described by non-linear diffusion equations. By combining all carbon species into a single equation, we can eliminate — in certain limits — the source terms associated with chemical reactions. In this case, the governing equation is ∂θ/∂t = –∇ · (–D eff ∇ θ ). For a sorbent in a form of a flat sheet or a membrane, one can maintain the same functional form of a diffusion equation by introducing a generalized effective diffusivity D M that combines contributions from both surface chemical reaction kinetics and interior diffusive transport kinetics. Experimental data of transient CO 2 flux in a preconditioned commercial anion exchange membrane fit well to the 1st order model as long as very dry states are avoided, validating the theory. The observed DM for a preconditioned commercial anion exchange membrane ranges from 6.6× 10 -14 to 7.1× 10 -14 m 2 s -1 at 35°C. These small values compared to typical ionic diffusivities imply a very slow kinetics, which will be the largest issue that needs to be addressed for practical application. The collected transient CO 2 flux data are used to predict the magnitude of a continuous CO 2 pumping flux in an active membrane that transports CO 2 against a CO 2 concentration gradient. The pumped CO 2 flux is supported by water flux due to a water concentration gradient.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Upwind Moisture Controls on Interannual Variations of Precipitation and Vegetation in China's Drylands

Dryland precipitation depends on upwind and local moisture sources via moisture recycling. How upwind moisture variations affect interannual variations of downwind precipitation and vegetation in China's drylands remains unclear. We used high-resolution moisture tracking data sets and found terrestrial moisture (93%) was the dominant moisture source for China's drylands, especially from drylands themselves (46%). In most dryland grids, we observed strong correlations between precipitation and upwind moisture sources from 2003 to 2022 (median r = 0.55), with a more significant effect in drier areas. These demonstrated the upwind moisture control on interannual variations of dryland precipitation, in which internal moisture from drylands exceeds the influence of external terrestrial sources. The upwind moisture variations, especially the recycled moisture of drylands, propagate to influence downwind vegetation greenness in precipitation-sensitive dryland areas. Our findings revealed that upwind moisture variations induced by climate or land-cover changes have important implications for water and food security in China's drylands.

54 ENVIRONMENTAL SCIENCES↗

Evaluating Moisture Control of Variable-Capacity Heat Pumps in Mechanically Ventilated, Low-Load Homes in Climate Zone 2A

The well-sealed, highly insulated building enclosures constructed by today's home building industry coupled with efficient lighting and appliances are achieving significantly reduced heating and cooling loads. These low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. Even if fixed-capacity equipment can be properly specified for peak loads, it remains oversized for use during much of the year. During these part-load cooling hours, oversized equipment meets the target dry-bulb temperatures very quickly, often without sufficient opportunity for moisture control. The problem becomes more acute for high-performance houses in humid climates when meeting ASHRAE Standard 62.2 recommendations for wholehouse mechanical ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hygrothermal analyses of the moisture control and energy efficiency potential of an adaptive water-resistive barrier for building envelopes

A water-resistive barrier (WRB) is a material installed on the exterior side of the sheathing to prevent water intrusion so that building components are not damaged by moisture. A membrane that can change its water vapor permeability between two states to control water vapor transport into and out of residential and commercial building wall systems is being developed. This simulation study assesses if this membrane used as a WRB reduces moisture levels and mold growth risk in exterior walls and building energy consumption. The developed membrane may require modifications to fully function as a WRB in contact with liquid water. Hygrothermal component simulations were conducted for different climate zones, different wall assemblies, different switching points and permeabilities to identify the most beneficial application cases and their required perm range and switching control. The study details the required simulation settings and suggests that the switchable membrane can reduce the water content in the sheathing and reduce the mold growth risk in the cavity in all climate zones. The effect on energy consumption of the switchable membrane is not significant. The study also includes recommendations on how to model the material characteristics of a switchable membrane and recommendations on practical applications for the switchable membrane.

42 ENGINEERING↗

Re-evaluation of Moisture Controls During ARIES Oxide Processing, Packaging and Characterization

DOE-STD-3013 [1] requires limiting the relative humidity (RH) in the glovebox during processing of the oxide product for specific types of plutonium oxides. This requirement is mandated in order to limit corrosion of the stainless steel containers by deliquescence of chloride salts if present in the PuO2. DOE-STD-3013 also specifies the need to limit and monitor internal pressure buildup in the 3013 containers due to the potential for the generation of free H2 and O2 gas from the radiolysis of surfaceadsorbed water. DOE-STD-3013 requires that the oxide sample taken for moisture content verification be representative of the stabilized material in the 3013 container. This is accomplished by either limiting the time between sampling and packaging, or by control of the glovebox relative humidity (%RH). This requirement ensures that the sample is not only representative, but also conservative from the standpoint of moisture content.

36 MATERIALS SCIENCE↗

Evaluating Moisture Control of Variable-Capacity Heat Pumps in Mechanically Ventilated, Low-Load Homes in Climate Zone 2A

Low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. This report evaluates the performance of variable-capacity comfort systems, with a focus on inverter-driven, variable-capacity systems, as well as proposed system enhancements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Consumer Guide to Durable Attics

Learn about controlling moisture and ventilation in your attic, as well as the steps to create a durable attic. This fact sheet from Energy Saver includes information on why moisture control in attics is important and the strategies you can use to control moisture and ventilation in your attic.

attic, moisture, ventilation, Energy Saver↗

Technology Solutions Case Study: Improving Comfort in Hot-Humid Climates with a Whole-House Dehumidifier

In order to quantify the performance of a combined whole-house dehumidifier (WHD) AC system, researchers from the Consortium of Advanced Residential Buildings (CARB) team monitored the operation of two Lennox AC systems coupled with a Honeywell DH150 TrueDRY whole-house dehumidifier for a six-month period. By using a WHD to control moisture levels (latent cooling) and optimizing a central AC to control temperature (sensible cooling), improvements in comfort can be achieved while reducing utility costs. Indoor comfort for this study was defined as maintaining indoor conditions at below 60% RH and a humidity ratio of 0.012 lbm/lbm while at common dry bulb set point temperatures of 74°-80°F. In addition to enhanced comfort, controlling moisture to these levels can reduce the risk of other potential issues such as mold growth, pests, and building component degradation. Because a standard AC must also reduce dry bulb air temperature in order to remove moisture, a WHD is typically needed to support these latent loads when sensible heat removal is not desired.

air conditioning↗

Barriers to Developing Sustainable Supply of Lignocellulosic Feedstock for Production of Biofuels

Thirteen unique storage conditions of baled corn stover biomass were studied to examine the impact of bale type, baling technique, and storage practice on moisture control and product degradation over time. Square bales were found to outperform round bales in terms of moisture regulation and physical stability across all treatment types and at all sampling times. Within square bales, the control of moisture content in short term storage (3 months) is comparable between tarped and untarped stacks. In long term storage (9 months), bale wrapping outperforms both tarped and open stacks. In terms of overall moisture control, stack tarping allows moisture to leave initially wet bales, but allows dry bales to gain large amounts of moisture over time. Initial moisture content was found to drive self-heating and depend heavily on storage practice. While differences in dry matter loss over time are unclear, bale stability was lowest in the untarped stack, moderate in tarped stacks, and greatest in wrapped stacks. Overall, bale storage has been shown to be a dynamic system which requires special judgment to be made depending on the state of inbound material and the desired storage duration.

Feedstock↗

Spray Foam in Accessible Spaces: Best Practices and Case Studies for Retrofit in Mixed-Humid Climates

Heating and cooling the house is one of the homeowners major expenses. Reducing these costs, saving energy, and creating a healthier, more comfortable indoor environment are good reasons to consider improving the building thermal envelope. Improvements usually consider increasing the amount of insulation, reducing the infiltration of outside air, and controlling moisture in existing buildings. This report describes the use of spray foam materials to insulate, seal, and control moisture. This discussion is limited to treating areas that are accessible. What is accessible, however, can vary depending on the type of renovation. If the building has been gutted or exterior surfaces removed, there are more options. This report will look at areas to consider for spray foam application and discuss the types of spray foams available and their uses. A number of case studies are presented to show the effectiveness of this retrofit in existing houses based on performance data.

Best practices↗

Improving Comfort in Hot-Humid Climates with a Whole-House Dehumidifier, Windermere, Florida [Fact Sheet]

Maintaining comfort in a home can be challenging in hot-humid climates. At the common summer temperature set point of 75°F, the perceived air temperature can vary by 11°F because higher indoor humidity reduces comfort. Often the air conditioner (AC) thermostat set point is lower than the desirable cooling level to try to increase moisture removal so that the interior air is not humid or "muggy." However, this method is not always effective in maintaining indoor relative humidity (RH) or comfort. In order to quantify the performance of a combined whole-house dehumidifier (WHD) AC system, researchers from the U.S. Department of Energy's Building America team Consortium of Advanced Residential Buildings (CARB) monitored the operation of two Lennox AC systems coupled with a Honeywell DH150 TrueDRY whole-house dehumidifier for a six-month period. By using a WHD to control moisture levels (latent cooling) and optimizing a central AC to control temperature (sensible cooling), improvements in comfort can be achieved while reducing utility costs. Indoor comfort for this study was defined as maintaining indoor conditions at below 60% RH and a humidity ratio of 0.012 lbm/lbm while at common dry bulb set point temperatures of 74°-80°F. In addition to enhanced comfort, controlling moisture to these levels can reduce the risk of other potential issues such as mold growth, pests, and building component degradation. Because a standard AC must also reduce dry bulb air temperature in order to remove moisture, a WHD is typically needed to support these latent loads when sensible heat removal is not desired.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Manipulative experiments demonstrate how long-term soil moisture changes alter controls of plant water use

Tree transpiration depends on biotic and abiotic factors that might change in the future, including precipitation and soil moisture status. Although short-term sap flux responses to soil moisture and evaporative demand have been the subject of attention before, the relative sensitivity of sap flux to these two factors under long-term changes in soil moisture conditions has rarely been determined experimentally. We tested how long-term artificial change in soil moisture affects the sensitivity of tree-level sap flux to daily atmospheric vapor pressure deficit (VPD) and soil moisture variations, and the generality of these effects across forest types and environments using four manipulative sites in mature forests. Exposure to relatively long-term (two to six years) soil moisture reduction decreases tree sap flux sensitivity to daily VPD and relative extractable water (REW) variations, leading to lower sap flux even under high soil moisture and optimal VPD. Inversely, trees subjected to long-term irrigation showed a significant increase in their sensitivity to daily VPD and REW, but only at the most water-limited site. The ratio between the relative change in soil moisture manipulation and the relative change in sap flux sensitivity to VPD and REW variations was similar across sites suggesting common adjustment mechanisms to long-term soil moisture status across environments for evergreen tree species. Overall, our results show that long-term changes in soil water availability, and subsequent adjustments to these novel conditions, could play a critical and increasingly important role in controlling forest water use in the future.

acclimation↗

Requirements and Conceptual Design of Off-gas Systems for the Reprocessing of Metallic Fuels

An assessment has been conducted to determine how key regulations regarding volatile radionuclide emissions to the atmosphere may apply to the off-gas streams associated with electrochemical reprocessing. The scope of this assessment was based upon a generic electrochemical reprocessing scheme with a throughput rate of 200 MTIHM/y applied to metallic fuel discharged from a sodium fast reactor (SFR), but the findings are able to be translated to other advanced nuclear scenarios as merited. Air dispersion modeling was performed using the EPA CAP-88 model and evaluated the uncontrolled decontamination factors (DFs) that would be required to achieve regulatory compliance with the dose-based limits set forth by EPA regulation 40 CFR 190.10(a). These DFs were compared to those required by fuel cycle–based limits set forth by EPA regulation 40 CFR 190.10(b). Two theoretical sites with disparate climatological conditions were selected for air dispersion modeling (Idaho and Tennessee). The radionuclides modeled included 3 H, 85 Kr, 129 I, and selected alpha-emitting transuranic isotopes (referred to here as 239 Pu-TRU <1y ). It was found that the fuel cycle-based limits in 40 CFR 190.10(b) are most restrictive for 85 Kr and 239 Pu-TRU <1y , with DFs of 3 and 6.1E+09, respectively. The dose-based limit as derived from 40 CFR 190.10(a) could require mitigation of tritium in some scenarios, with an estimated DF of about 3 for the reference scenarios. The fuel cycle-based limit for 129 I resulted in a DF of about 240 for the reference scenario. The need for iodine mitigation based on dose to the public depended upon the physical form of iodine as either particulate or vapor-phase species. Emission of iodine from the facility as a vapor necessitated DFs of about 2 but emission as a particulate would require DFs >6,000 to meet thyroid dose-based limits. Effects of physical form on needed iodine mitigation are significant, but the understanding of speciation of iodine both during electrochemical reprocessing and after release to the atmosphere is limited. The electrochemical processing unit operations were evaluated to identify potential release points for the volatile radionuclides and to assess the potential for retention of the radionuclides within the process (thus decreasing the need for mitigation). Mitigation strategies for 3 H, 85 Kr, 129 I, and 239 Pu-TRU <1y were identified. In all cases, there are reasonably achievable pathways to regulatory compliance, although in some cases additional R&D is merited to verify the chemical speciation of these isotopes and to develop and demonstrate potential treatment technologies for this application. Whether or not additional off-gas controls (beyond common operations such as HEPA filtration and oxygen and moisture control) are needed for any of these regulated or volatile radionuclides depends on the (a) type of facility (NRC-regulated or DOE), (b) used fuel process rate, (c) used fuel burnup and composition, (d) speciation and retention of volatile radionuclides in the process and in the cell gas cleanup system, (e) site-specific parameters such as location, meteorology, stack height, and site boundaries, and (f) levels of conservatism and safety factors used in assessing compliance to air emissions regulations. Performance of this assessment revealed several areas where information is lacking or additional research is required in order to better determine if or what kinds of off-gas control might be needed. First, and most significantly, the understanding of the chemical speciation and physical form and partitioning of iodine during electrochemical processing operations is lacking and prevents the ability to accurately assess the potential iodine mitigation requirements. Future research in this area should be multifaceted and include thermodynamic modeling of iodine speciation in different process steps, experiments to quantify the kinetics of vapor-phase and melt-phase transitions, bench-scale experiments to determine the potential chemical and physical form of iodine emissions from the electrorefining process, and verification of iodine behavior with experiments utilizing operational facilities. Similarly, an improved understanding of iodine behavior in the environment after release from the facility stack will be required to refine dose estimations, as particulate and vapor-phase emissions result in significantly different doses to the MEI.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wall Upgrades for Residential Deep Energy Retrofits: A Literature Review

In the United States, 39% of total energy consumption comes from the building sector, 20% of which is attributed to residential buildings. New, high-performance homes incorporate a combination of tight building envelopes, mechanical ventilation and efficient components to ensure comfort, adequate airflow and moisture control. These systems work together to create energy efficient homes that employ measures to manage moisture and indoor pollutants. Older homes, built before 1992 when DOE’s Building Energy Codes Program was established represent approximately 68% of building stock in the country, and often have significant air leakage and inadequate insulation. Homes with little to no air sealing or insulation result in heating and cooling losses, which can represent a substantial portion of utility bills. Done correctly, deep energy retrofits (DERs) can significantly improve the energy performance of a home’s thermal envelope, decrease indoor pollutants and increase homeowner comfort. This literature review summarizes current practices for exterior wall retrofits for existing homes, provides an overview of techno-economic approaches to investigate residential wall systems, and discusses thermal and hygrothermal modeling strategies. Accompanying this literature review is a larger effort to identify state-of-the-art technologies for existing wall energy efficiency retrofit systems that can be applied over existing siding and are suitable for the cold/very cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗