The UCB/MPE Cassegrain Submillimeter Heterodyne Spectrometer

The UCB/MPE Submillimeter Heterodyne Spectrometer is a system for astronomical spectroscopy in the high-frequency atmospheric windows from 500 to 1000 GHz. It contains a molecular laser local oscillator, a cooled Schottky open structure mixer, a quasi-optical coupling system, and an acoustooptical spectrometer. The compact receiver mounts at the Cassegrain focus of large infrared astronomical telescopes. The receiver noise temperature on the telescope is approximately 3500 K (DSB) during observations of the CO J = 7-6 line at 806.652 GHz. The spectrometer's frequency resolution and instantaneous bandwidth (less than 2 MHz resolution across 1.1 GHz) are well suited for observations of molecular emission lines from a variety of astronomical sources.

Harris, A. I.↗

Indium Single-Ion Frequency Standard

A single laser-cooled indium ion is a promising candidate for an ultimate resolution optical time or frequency standard. It can be shown that single ions from group IIIA of the periodic table (indium, thallium, etc.) can have extremely small systematic errors. In addition to being free from Doppler, transit-time and collisional shifts, these ions are also quite insensitive to perturbations from ambient magnetic and electric fields (mainly due to the use of a J=0-0 transition for spectroscopy). Of all group IIIA ions, indium seems to be the most practical, since it is heavy enough to have a tolerable intercombination cooling transition rate and (unlike thallium) has transitions which are easily accessible with frequency multiplied continuous-wave lasers. A single indium ion standard has a potential inaccuracy of one part in 10(exp 18) for integration times of 10(exp 6) seconds. We have made substantial progress during the grant period in constructing a frequency standard based upon a single indium ion. At the beginning of the grant period, single indium ions were being successfully trapped, but the lasers and optical systems were inadequate to achieve the desired goal. We have considerably improved the stability of the dye laser used to cool the ions and locked it to a molecular resonance line, making it possible to observe stable cooling-line fluorescence from a single indium ion for reasonable periods of time, as required by the demands of precision spectroscopy. We have substantially improved the single-ion fluorescence signal with significant benefits for the detection efficiency of forbidden transitions using the 'shelving' technique. Finally, we have constructed a compact, efficient UV 'clock' laser and observed 'clock' transitions in single indium ions using this laser system. We will elaborate on these accomplishments.

Nagourney, Warren↗

Plasma dust crystallization

In a ground-based definition study, a concept for a new type of microgravity experiment is developed. We formed a new state of matter: a crystalline lattice structure of charged micron-size spheres, suspended in a charge-neutral plasma. The plasma is formed by a low-pressure radio-frequency argon discharge. Solid microspheres are introduced, and they gain a negative electric charge. They are cooled by molecular drag on the ambient neutral gas. They are detected by laser light scattering and video photography. Laboratory experiments have demonstrated that a two-dimensional nonquantum lattice forms through the Coulomb interaction of these spheres. Microgravity is thought to be required to observe a three-dimensional structure.

Goree, John↗

Solar-pumped electronic-to-vibrational energy transfer lasers

The possibility of using solar-pumped lasers as solar energy converters is examined. The absorbing media considered are halogens or halogen compounds, which are dissociated to yield excited atoms, which then hand over energy to a molecular lasing medium. Estimates of the temperature effects for a Br2-CO2-He system with He as the cooling gas are given. High temperatures can cause the lower energy levels of the CO2 laser transition to be filled. The inverted populations are calculated and lasing should be possible. However, the efficiency is less than 0.001. Examination of other halogen-molecular lasant combinations (where the rate coefficients are known) indicate efficiencies in all cases of less than 0.005.

Harries, W. L.↗

Polar nephelometer for atmospheric particulate studies

A polar nephelometer for use in studying atmospheric aerosols was developed. The nephelometer detects molecular scatter from air and measures scattering from very clean air using pure molecular scattering for calibration. A compact system using a folded light path with an air cooled argon laser for the light source was designed. A small, sensitive detector unit permits easy angular rotation for changing the scattering angle. A narrow detector field of view of + or - 1/4 degree of scattering along with a single wavelength of incident light is used to minimize uncertainties in the scattering theory. The system is automated for data acquisition of the scattering matrix elements over an angular range from 2 degrees to 178 degrees of scattering. Both laser output and detector sensitivity are monitored to normalize the measured light scattering.

Hansen, M. Z.↗

Study of Injection of Helium into Supersonic Air Flow Using Rayleigh Scattering

A study of the transverse injection of helium into a Mach 3 crossflow is presented. Filtered Rayleigh scattering is used to measure penetration and helium mole fraction in the mixing region. The method is based on planar molecular Rayleigh scattering using an injection-seeded, frequency-doubled ND:YAG pulsed laser and a cooled CCD camera. The scattered light is filtered with an iodine absorption cell to suppress stray laser light. Preliminary data are presented for helium mole fraction and penetration. Flow visualization images obtained with a shadowgraph and wall static pressure data in the vicinity of the injection are also presented.

Seaholtz, Richard G.↗

Fluorine and Lithium at the Kimberley Outcrop, Gale Crater

ChemCam is an active remote sensing instrument which has operated successfully on MSL since landing in August, 2012. Its laser pulses remove dust and to profile through weathering coatings of rocks up to 7 m away. Laser-induced breakdown spectroscopy (LIBS) produces emission spectra of materials ablated from the samples in electronically excited states. As the plasma cools, elements can recombine and molecular emission lines are observed. Recent experiments have shown that some of these molecular emissions can be much brighter than the associated atomic lines, especially when halo-gens and rare earth elements are present. We observed these molecular emissions in some of the ChemCam spectra and report the first detection of chlorine and fluorine with ChemCam. It is also the first time ever that fluorine has been detected on the surface of Mars. Among all the F-bearing observations, one third are observed in the Kimberley outcrop. We will dis-cuss the potential mineralogies related to these observations as well as the related elemental correlations and propose interpretations.

Forni, O.↗

Application of Laser Mass Spectrometry to Art and Archaeology

REMPI laser mass spectrometry is a combination of resonance enhanced multiphoton ionization spectroscopy and time of flight mass spectrometry, This technique enables the collection of mass specific optical spectra as well as of optically selected mass spectra. Analytes are jet-cooled by entrainment in a molecular beam, and this low temperature gas phase analysis has the benefit of excellent vibronic resolution. Utilizing this method, mass spectrometric analysis of historically relevant samples can be simplified and improved; Optical selection of targets eliminates the need for chromatography while knowledge of a target's gas phase spectroscopy allows for facile differentiation of molecules that are in the aqueous phase considered spectroscopically indistinguishable. These two factors allow smaller sample sizes than commercial MS instruments, which in turn will require less damage to objects of antiquity. We have explored methods to optimize REMPI laser mass spectrometry as an analytical tool to archaeology using theobromine and caffeine as molecular markers in Mesoamerican pottery, and are expanding this approach to the field of art to examine laccaic acid in shellacs.

Gulian, Lase Lisa E.↗

Fullerene Machines

Recent computational efforts at NASA Ames Research Center and computation and experiment elsewhere suggest that a nanotechnology of machine phase functionalized fullerenes may be synthetically accessible and of great interest. We have computationally demonstrated that molecular gears fashioned from (14,0) single-walled carbon nanotubes and benzyne teeth should operate well at 50-100 gigahertz. Preliminary results suggest that these gears can be cooled by a helium atmosphere and a laser motor can power fullerene gears if a positive and negative charge have been added to form a dipole. In addition, we have unproven concepts based on experimental and computational evidence for support structures, computer control, a system architecture, a variety of components, and manufacture. Combining fullerene machines with the remarkable mechanical properties of carbon nanotubes, there is some reason to believe that a focused effort to develop fullerene nanotechnology could yield materials with tremendous properties.

Globus, Al↗

Thermodynamic processes induced by coherent radiation

It is shown by quantum statistics that under certain stated conditions the entropy of coherent radiation is zero and it is still negligible for multimode laser operation. This makes possible gas kinetic processes which, to a small extent, have already been observed or even utilized, but which can be greatly enhanced by an optimized choice of molecular structures and radiation conditions. Radiative cooling of gases is discussed in detail. The conditions for maximum heat withdrawal are derived, and it is proposed that the processes of cooling and relaxation heating can be sufficiently separated in time to achieve certain effects and thermodynamic cycles. One of these is the complete conversion, possible in principle, of coherent radiation into work. This concept is based on a heat pump process followed by heat-to-work conversion, the heat rejected being just equal to that withdrawn by radiation. The conditions for complete conversion turn out to be the same as for maximum heat withdrawal. The feasibility of these processes depends on the degree to which practical conditions can be met, and on the validity of certain assumptions which have to await experimental verification.

Garbuny, M.↗

Laser supported detonation wave source of atomic oxygen for aerospace material testing

A pulsed high-flux source of nearly monoenergetic atomic oxygen was developed to perform accelerated erosion testing of spacecraft materials in a simulated low-earth orbit (LEO) environment. Molecular oxygen is introduced into an evacuated conical expansion nozzle at several atmospheres pressure through a pulsed molecular beam valve. A laser-induced breakdown is generated in the nozzle throat by a pulsed CO2 TEA laser. The resulting plasma is heated by the ensuing laser-supported detonation wave, and then it rapidly expands and cools. An atomic oxygen beam is generated with fluxes above 10 to the 18th atoms per pulse at 8 + or - 1.6 km/s with an ion content below 1 percent for LEO testing. Materials testing yielded the same surface oxygen enrichment in polyethylene samples as observed on the STS mission, and scanning electron micrographs of the irradiated polymer surfaces showed an erosion morphology similar to that obtained on low earth orbit.

Krech, Robert H.↗

Pulsed source of energetic atomic oxygen

A pulsed high flux source of nearly monoenergetic atomic oxygen was designed, built, and successfully demonstrated. Molecular oxygen at several atmospheres pressure is introduced into an evacuated supersonic expansion nozzle through a pulsed molecular beam valve. An 18 J pulsed CO2 TEA laser is focused to intensities greater than 10(9) W/sq cm in the nozzle throat to generate a laser-induced breakdown. The resulting plasma is heated in excess of 20,000 K by a laser supported detonation wave, and then rapidly expands and cools. Nozzle geometry confines the expansion to provide rapid electron-ion recombination into atomic oxygen. Average O atom beam velocities from 5 to 13 km/s were measured at estimated fluxes to 10(18) atoms per pulse. Preliminary materials testing has produced the same surface oxygen enrichment in polyethylene samples as obtained on the STS-8 mission. Scanning electron microscope examinations of irradiated polymer surfaces reveal an erosion morphology similar to that obtained in low Earth orbit, with an estimated mass removal rate of approx. 10(-24) cu cm/atom. The characteristics of the O atom source and the results of some preliminary materials testing studies are reviewed.

Caledonia, George E.↗

Infrared laser spectroscopy of jet-cooled carbon clusters: the nu 5 band of linear C9

The nu 5 antisymmetric stretching vibration of 1 sigma+g C9 has been observed using direct infrared diode laser absorption spectroscopy of a pulsed supersonic cluster beam. Twenty-eight rovibrational transitions measured in the region of 2079-2081 cm-1 were assigned to this band. A combined least squares fit of these transitions with previously reported nu 6 transitions yielded the following molecular constants for the nu 5 band: nu 0 = 2 079.673 58(17) cm-1, B"= 0.014 321 4(10) cm-1, and B'=0.014 288 9(10) cm-1. The IR intensity of the nu 5 band relative to nu 6 was found to be 0.108 +/- 0.006. Theoretical predictions for the relative intensities vary widely depending upon the level of theory employed, and the experimental value reported here is in reasonable agreement only with the result obtained from the most sophisticated ab initio calculation considered (CCSD).

Non-NASA Center↗

Performance of a Herriott Cell, Designed for Variable Temperatures between 296 and 20 K

We designed, fabricated and tested a multipath Herriott cell (or off-axis spherical mirror interferometer) to achieve low temperature absorption measurements. The cell is fabricated entirely from copper and the 15 cm radius of curvature copper mirrors have gold coated reflective surfaces. The cell was tested at temperatures between 296 and 30 K with a folded absorption path length of 5.37 m utilizing a lead salt tunable diode laser. Short term temperature stability (1 h) of the Herriott cell is better than 0.005 K under normal operating conditions with a temperature uniformity better than 0.01 K (not measurable). The cell was tested by performing collisional cooling experiments on 13C16O2 in helium at temperatures between 70 and 20 K and by performing more traditional pressure broadening and shift measurements on molecular infrared absorption lines at temperatures between 300 and about 80 K on 13C16O2 methane.

Mondelain, Didier↗