Search NASA⌕ Search

SEARCH · Search NASA

Results for “monitoring demonstrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development and Certification of Station Development Test Objective (SDTO) Experiment # 15012-U, "Near RealTime Water Quality Monitoring Demonstration for ISS Biocides Using Colorimetric Solid Phase Extraction (CSPE)"

Scientists and engineers from the Wyle Integrated Science and Engineering Group are working with researchers at the University of Utah and Iowa State University to develop and certify an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE). The kit will be launched as a Station Development Test Objective (SDTO) experiment and evaluated on the International Space Station (ISS) to determine the acceptability of CSPE technology for routine inflight water quality monitoring. Iodine and silver, the biocides used in the US and Russian on-orbit water systems, will serve as test analytes for the technology evaluation. This manuscript provides an overview of the CSPE SDTO experiment and details the development and certification of the experimental water quality monitoring kit. Initial results from reagent and standard solution stability testing and environmental testing performed on the kit hardware are also reported.

Gazda, Daniel B.↗

Link monitor and control operator assistant: A prototype demonstrating semiautomated monitor and control

This article describes the approach, results, and lessons learned from an applied research project demonstrating how artificial intelligence (AI) technology can be used to improve Deep Space Network operations. Configuring antenna and associated equipment necessary to support a communications link is a time-consuming process. The time spent configuring the equipment is essentially overhead and results in reduced time for actual mission support operations. The NASA Office of Space Communications (Code O) and the NASA Office of Advanced Concepts and Technology (Code C) jointly funded an applied research project to investigate technologies which can be used to reduce configuration time. This resulted in the development and application of AI-based automated operations technology in a prototype system, the Link Monitor and Control Operator Assistant (LMC OA). The LMC OA was tested over the course of three months in a parallel experimental mode on very long baseline interferometry (VLBI) operations at the Goldstone Deep Space Communications Center. The tests demonstrated a 44 percent reduction in pre-calibration time for a VLBI pass on the 70-m antenna. Currently, this technology is being developed further under Research and Technology Operating Plan (RTOP)-72 to demonstrate the applicability of the technology to operations in the entire Deep Space Network.

Lee, L. F.↗

Integration and Demonstration of Monitoring, Modeling, and Prediction of DV-1 Amendment Performance at the Bench Scale: DV-1 Amendment Demonstration

During fiscal years 2024 and 2025, the U.S. Department of Energy’s Hanford Field Office commissioned Pacific Northwest National Laboratory to conduct applied research aimed at reducing the cost, time, and uncertainty associated with in situ treatment of vadose zone contaminants at the Hanford Site. This report outlines the integration of three key research efforts into a meso-scale demonstration designed to advance field-scale solutions that aim to (1) optimize the delivery of chemical amendments to contaminated soils, (2) reduce uncertainty in amendment delivery performance assessment using advanced monitoring techniques, and (3) provide real-time insights into when and where amendment-induced precipitation reactions occur in the subsurface. To achieve these objectives, the tank-scale (~ 1 cubic meter) Geophysical Imaging of Flow and Transport (GIFT) system was developed. GIFT enables experimental testing of amendment delivery while incorporating automated multi-modal monitoring approaches, including pressure measurements, direct fluid sampling, and remote time-lapse geophysical imaging. The data generated from these monitoring techniques will serve as inputs for a generative artificial-intelligence-driven digital twin – a numerical simulation model designed to honor observed data while quantifying uncertainty in simulation accuracy. Using this simulator, researchers will refine an amendment injection strategy to maximize delivery efficiency within a low-permeability soil zone. Monitoring data will be interpreted through simulated outputs to enhance understanding of the injection process. The efficacy of this integrated approach will be evaluated through direct sampling at the conclusion of the experiment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optical Multi-Gas Monitor Technology Demonstration on the International Space Station

There are a variety of both portable and fixed gas monitors onboard the International Space Station (ISS). Devices range from rack-mounted mass spectrometers to hand-held electrochemical sensors. An optical Multi-Gas Monitor has been developed as an ISS Technology Demonstration to evaluate long-term continuous measurement of 4 gases. Based on tunable diode laser spectroscopy, this technology offers unprecedented selectivity, concentration range, precision, and calibration stability. The monitor utilizes the combination of high performance laser absorption spectroscopy with a rugged optical path length enhancement cell that is nearly impossible to misalign. The enhancement cell serves simultaneously as the measurement sampling cell for multiple laser channels operating within a common measurement volume. Four laser diode based detection channels allow quantitative determination of ISS cabin concentrations of water vapor (humidity), carbon dioxide, ammonia and oxygen. Each channel utilizes a separate vertical cavity surface emitting laser (VCSEL) at a different wavelength. In addition to measuring major air constituents in their relevant ranges, the multiple gas monitor provides real time quantitative gaseous ammonia measurements between 5 and 20,000 parts-per-million (ppm). A small ventilation fan draws air with no pumps or valves into the enclosure in which analysis occurs. Power draw is only about 3 W from USB sources when installed in Nanoracks or when connected to 28V source from any EXPRESS rack interface. Internal battery power can run the sensor for over 20 hours during portable operation. The sensor is controlled digitally with an FPGA/microcontroller architecture that stores data internally while displaying running average measurements on an LCD screen and interfacing with the rack or laptop via USB. Design, construction and certification of the Multi-Gas Monitor were a joint effort between Vista Photonics, Nanoracks and NASA-Johnson Space Center (JSC). Vista Photonics developed the core technology and built the sensor. Nanoracks designed, constructed the enclosure, interfaces, and battery power management circuitry, integrated all subsystems into the enclosure, and then managed the certification tests, documentation and manifesting. The unit was calibrated in the JSC Toxicology Laboratory. The Multi-Gas Monitor is manifested to fly as a technology demonstration to the ISS in November 2013 and will operate for at least 6 months with data sent to the ground for evaluation. The primary goal is to demonstrate long term interference free operation in the real spacecraft environment.

Pilgrim, Jeffrey S.↗

Registration and fusion of large-scale melt pool temperature and morphology monitoring data demonstrated for surface topography prediction in LPBF

In-situ monitoring technologies for laser powder bed fusion (LPBF) additive manufacturing often face one key challenge, extracting the ultrafast melt pool (MP) signatures for understanding the localized part properties. Further, the spatial information of each monitored MP signature is essential for correlating the MP – part property. This spatial information is often unavailable especially from commercial LPBF printers. Many MP monitoring methods have been reported and utilized. However, very few of these have the MP’s spatial information. To overcome this challenge, in this work we report a method for spatially registering the key MP signatures (MP intensity, temperature, and area) to the monitored print parts. The MP signatures are obtained from our coaxial high-speed single-camera based two-wavelength imaging pyrometry (STWIP) system and the MP spatial information is obtained from an off-axis camera system. A machine learning aided image analysis method is employed to retrieve the spatial distribution of MPs within the corresponding part’s coordinates system. Then, the MP signature maps (MPSMs) are reconstructed by mapping the STWIP measured MP signatures to the registered MP coordinates. Further, a long short-term memory (LSTM) neural network is developed for estimating the layer surface topography from the registered MPSMs. The obtained results indicate that the layer surface topography can be more accurately estimated by using MP temperature signature rather than MP intensity and/or area signatures as in common practice. Finally, our developed methods for MP monitoring, registration, and MP-surface topography prediction offer advanced capabilities for the online detection of process anomalies and part defects.

36 MATERIALS SCIENCE↗

Monitoring, Verification, and Accounting (MVA) Strategy for a North Dakota Carbon Capture and Storage Project Integrated with Ethanol Production: Developing and Demonstrating Sustainable Monitoring Techniques

Conference presentation at American Association of Petroleum Geologists (AAPG) Carbon Capture, Utilization, and Storage (CCUS) Conference, Houston, Texas, March 28–30, 2022. An overview of the novel and sustainable monitoring techniques developed by the University of North Dakota's Energy & Environmental Research Center (EERC) and its commercial partners for the Red Trail Energy (RTE) carbon capture and storage (CCS) project.

01 COAL, LIGNITE, AND PEAT↗

Optical Multi-Gas Monitor Technology Demonstration on the International Space Station

The International Space Station (ISS) employs a suite of portable and permanently located gas monitors to insure crew health and safety. These sensors are tasked with functions ranging from fixed mass spectrometer based major constituents analysis to portable electrochemical sensor based combustion product monitoring. An all optical multigas sensor is being developed that can provide the specificity of a mass spectrometer with the portability of an electrochemical cell. The technology, developed under the Small Business Innovation Research program, allows for an architecture that is rugged, compact and low power. A four gas version called the Multi-Gas Monitor was launched to ISS in November 2013 aboard Soyuz and activated in February 2014. The portable instrument is comprised of a major constituents analyzer (water vapor, carbon dioxide, oxygen) and high dynamic range real-time ammonia sensor. All species are sensed inside the same enhanced path length optical cell with a separate vertical cavity surface emitting laser (VCSEL) targeted at each species. The prototype is controlled digitally with a field-programmable gate array/microcontroller architecture. The optical and electronic approaches are designed for scalability and future versions could add three important acid gases and carbon monoxide combustion product gases to the four species already sensed. Results obtained to date from the technology demonstration on ISS are presented and discussed.

Pilgrim, Jeffrey S.↗

Integrated Atmosphere Resource Recovery and Environmental Monitoring Technology Demonstration for Deep Space Exploration

Exploring the frontiers of deep space continues to be defined by the technological challenges presented by safely transporting a crew to and from destinations of scientific interest. Living and working on that frontier requires highly reliable and efficient life support systems that employ robust, proven process technologies. The International Space Station (ISS), including its environmental control and life support (ECLS) system, is the platform from which humanity's deep space exploration missions begin. The ISS ECLS system Atmosphere Revitalization (AR) subsystem and environmental monitoring (EM) technical architecture aboard the ISS is evaluated as the starting basis for a developmental effort being conducted by the National Aeronautics and Space Administration (NASA) via the Advanced Exploration Systems (AES) Atmosphere Resource Recovery and Environmental Monitoring (ARREM) Project.. An evolutionary approach is employed by the ARREM project to address the strengths and weaknesses of the ISS AR subsystem and EM equipment, core technologies, and operational approaches to reduce developmental risk, improve functional reliability, and lower lifecycle costs of an ISS-derived subsystem architecture suitable for use for crewed deep space exploration missions. The most promising technical approaches to an ISS-derived subsystem design architecture that incorporates promising core process technology upgrades will be matured through a series of integrated tests and architectural trade studies encompassing expected exploration mission requirements and constraints.

Perry, Jay L.↗

Demonstration of acoustic monitoring for structural health of microreactors: Through use of neural networks and resonant ultrasound spectroscopy

Nuclear microreactors prioritize modularity and portability and are intended to be a cost-effective technology for non-conventional nuclear markets. As such, the development of microreactors into a safe and feasible solution for energy security applications will necessitate the development of non-destructive technologies to monitor the integrity of inaccessible reactors components during operation. This demonstration applies linear and nonlinear acoustic techniques, in combination with machine learning, to detect and classify mechanical changes (stress and damage) in a test article which are broadly representative of potential operating challenges within a functioning microreactor. All necessary data has been collected for this demonstration, with minor experimental issues identified that can be addressed in follow-on work. Motivated by the expected conditions within a functioning microreactor, we have demonstrated our monitoring techniques on a core-block-like test article using an unstructured excitation source that approximates the noisy acoustic environment expected during reactor operation. At all stress states mechanically applied to the test article, a machine learning model using an artificial neural network was able to classify with 100% accuracy whether a 3D laser vibrometry point measurement was made on an intact or artificially defective test article. Further, model predictions about whether the defect interface was rough or smooth were 95% accurate, indicating the ability of acoustic techniques to recover defect characteristics. Resonant ultrasound spectroscopy (RUS) was also applied to the dataset to provide further quantitative insights about material properties. RUS analysis was ultimately hampered by several minor experimental and data issues, limiting results to certain cases for this demonstration. Last, analysis using nonlinear RUS exhibited sensitivity to changing levels of applied stresses for each intact and defective state. As presented in this demonstration, acoustic monitoring exhibits sensitivity to stress changes, which are of concern due to high thermal gradients expected during startup and operation. Further, our techniques distinguish between measurements made on intact and damaged test articles.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effectiveness and outcomes of invasive species removal in Hawaiian streams

Despite aquatic invasive species (AIS) being a widely recognized threat to native biodiversity in streams on subtropical and tropical oceanic islands across the Pacific, AIS management has been constrained by concerns that methods of removal could result in more harm than good. In this study, we assessed the effectiveness and outcomes of combining hand-netting and streamside sequestration of native species with AIS removal via three-pass electrofishing tailored for Hawaiian Island watersheds. Removals were conducted in 13 watersheds on the island of O‘ahu following a before-after, control-impact design to assess how AIS removal and post-removal community reassembly varied by surface flow and target species of interest. We found that removals resulted in a sharp reduction in AIS densities without altering native species densities. Removal efficacy was greatest in streams with intermediate mean discharge irrespective of target group or pre-removal AIS densities. Long-term monitoring demonstrated that removals led to persistent shifts in community composition reflecting sustained reductions in AIS densities. These findings indicate that electrofishing can be a valuable tool for AIS management in Hawaiian and other subtropical Pacific island streams, so long as steps are taken to minimize potential harm to at-risk and culturally important native species.

59 BASIC BIOLOGICAL SCIENCES↗

Status of the development and testing of in-vessel and ECH-protection components for the ITER low-field side reflectometer

The ITER Low-Field Side Reflectometer (LFSR) is a critical diagnostic system designed to measure edge electron density profiles, fluctuations, and plasma rotation in ITER. This paper presents the latest developments in the design, testing, and validation of key in-vessel and Electron Cyclotron Heating (ECH) protection components. The LFSR antenna array has been optimized to provide robust coverage over expected plasma vertical displacements and a Doppler measurement for plasma rotation. Further, a comprehensive assessment of a 170-GHz diffraction grating and a novel stray-ECH power monitor demonstrates effectiveness in mitigating the impact of stray ECH power on sensitive microwave electronics. Additionally, an advancement in anti-reflective technology for millimeter waves significantly improves transmission of LFSR's vacuum window while meeting ITER's stringent safety and operational requirements. These results support the continued integration of LFSR into ITER, ensuring its diagnostic capabilities remain resilient under reactor-relevant conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Site 300 Bat Survey Report

A review of prior bat records in literature and museum collections for the five counties around Site 300 (Alameda, Contra Costa, San Joaquin, Santa Clara, and Stanislaus) identified 1038 specimens of 15 species. No roosting bats or bat sign indicating roosting were observed in examining samples of structures on Site 300 both day and night. Acoustic monitoring and visual observation detected seven to nine species, including three special status species -- the pallid bat, Antrozous pallidus, the western red bat, Lasiurus blossevillii and the Yuma myotis, Myotis yumanensis. An additional special status species, the long-legged myotis, Myotis volans was possibly present. As a consequence of the windy conditions typically encountered, no bats were caught in mist net sampling, though simultaneous acoustic monitoring demonstrated bats were present at those locations.

54 ENVIRONMENTAL SCIENCES↗

Clean assembly and integration techniques for the Hubble Space Telescope High Fidelity Mechanical Simulator

A mechanical simulator of the Hubble Space Telescope (HST) Aft Shroud was built to perform verification testing of the Servicing Mission Scientific Instruments (SI's) and to provide a facility for astronaut training. All assembly, integration, and test activities occurred under the guidance of a contamination control plan, and all work was reviewed by a contamination engineer prior to implementation. An integrated approach was followed in which materials selection, manufacturing, assembly, subsystem integration, and end product use were considered and controlled to ensure that the use of the High Fidelity Mechanical Simulator (HFMS) as a verification tool would not contaminate mission critical hardware. Surfaces were cleaned throughout manufacturing, assembly, and integration, and reverification was performed following major activities. Direct surface sampling was the preferred method of verification, but access and material constraints led to the use of indirect methods as well. Although surface geometries and coatings often made contamination verification difficult, final contamination sampling and monitoring demonstrated the ability to maintain a class M5.5 environment with surface levels less than 400B inside the HFMS.

Hughes, David W.↗

A Dynamic/Anisotropic Low Earth Orbit (LEO) Ionizing Radiation Model

The International Space Station (ISS) provides the proving ground for future long duration human activities in space. Ionizing radiation measurements in ISS form the ideal tool for the experimental validation of ionizing radiation environmental models, nuclear transport code algorithms, and nuclear reaction cross sections. Indeed, prior measurements on the Space Transportation System (STS; Shuttle) have provided vital information impacting both the environmental models and the nuclear transport code development by requiring dynamic models of the Low Earth Orbit (LEO) environment. Previous studies using Computer Aided Design (CAD) models of the evolving ISS configurations with Thermo Luminescent Detector (TLD) area monitors, demonstrated that computational dosimetry requires environmental models with accurate non-isotropic as well as dynamic behavior, detailed information on rack loading, and an accurate 6 degree of freedom (DOF) description of ISS trajectory and orientation.

Badavi, Francis F.↗