Search NASASearch

SEARCH · Search NASA

Results for “motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluating Sensory Augmentation as A Non-Pharmaceutical Tool to Mitigate Motion Sickness and Enhance Sensorimotor Task Performance: A Pilot Study Using Simulated Capsule Wave Motion

Wave motion during capsule recovery operations can result in motion sickness and performance decrements exacerbating reentry sickness following long duration spaceflight. The purpose of this pilot study was (1) to validate a capsule wave motion simulation as a platform to evaluate motion sickness countermeasures and (2) to evaluate a sensory augmentation belt providing vibrotactile feedback of gravitational upright. Ten healthy subjects ages 38.0 ± 10.1 (6M|4F) were exposed to complex wave motions on a six degree-of-freedom platform that included pitch, roll, and heave at provocative stimulus frequencies (0.1-0.25 Hz) while seated in an illuminated cabin deprived of external visual cues. Subjects reported acute symptoms for up to three consecutive 15 min trials or until they reached a motion sickness endpoint of 8 pts on the Pensacola Diagnostic Index (PDI). Five subjects were randomly assigned to the Sensory Augmentation (SA) group while the other five served as controls (CN group). Based on a Motion Sickness Susceptibility Questionnaire, the two groups had similar motion sickness histories (susceptibility percentile ranking of CN group = 27.5 ± 63.6 in the CN group versus 27.5 ± 37.0 in the SA group, median ± IQR). The vibrotactile feedback consisted of a single array of 8 electromechanical tactors positioned around the torso on an adjustable belt (Engineering Acoustics, Inc) that utilized an integrated inertial measurement unit (IMU) to indicate the direction of upright (e.g., subject’s back tactor on during forward tilt). During each wave motion trial subjects performed a battery of four different tasks: tracking Earth vertical using a joystick with and without a secondary task (Paced Auditory Serial Addition Test), an eye-hand target acquisition task on a cabin-fixed tablet, and the psychomotor vigilance test (PVT). All ten subjects reported varying levels of motion sickness with 6 of 10 reaching a symptom endpoint. Interestingly, subjects anecdotally reported that engagement in the joystick tracking task was less provocative than tasks involving the cabin-fixed tablet or periods of no activity. Sensory augmentation appeared to delay symptom onset, with 2 of 5 subjects reaching an endpoint within the first 15 min trial in the CN group versus none in the SA group (PDI after 15 min = 6.0 ± 2.5 in the CN group versus 3.4 ± 2.5 in the SA group, mean ±std). Sensory augmentation also improved performance on the joystick tracking task at lower stimulus frequencies (0.1 Hz in roll and 0.2 Hz in pitch). Both CN and SA groups maintained a consistent level of performance on the eye-hand target acquisition and PVT throughout the baseline (no motion) and wave motion periods. Our results validated that the simulated capsule wave motion paradigm provides an effective motion sickness stressor. This paradigm is currently being used to investigate the efficacy of intranasal scopolamine to mitigate motion sickness. Sensory augmentation using vibrotactile feedback appears to improve spatial awareness and delay symptom onset during complex passive motion. One advantage of this portable belt design is that it incorporates all tactor drive and IMU circuitry and therefore could continue to be worn by crewmembers and serve as a balance aid during egress and ambulation with recovery operations.

A M Bollinger

Evaluation of Intranasal Scopolamine for the Prevention of Wave Motion Induced Motion Sickness While Maintaining Performance on Operationally Relevant Tasks

Motion sickness represents one of the greatest clinical challenges impacting crew activities during and following g-transitions. Our overall goal is to characterize the effectiveness of motion sickness countermeasures during controlled laboratory experiments using capsule wave motion simulation and during field testing in operational environments. This laboratory study focused on prevention of motion sickness using intranasal scopolamine using a double-blinded repeated measures design in 30 subjects (19M, 11F). Intranasal scopolamine was provided by Defender Pharmaceuticals, Inc. (DPI-386 Nasal Gel, referred to as Inscop) self-administered by a nasal pump (Aptar Pharma) that delivers 0.4 mg dose (0.2 mg / nostril). During each session, subjects were exposed to complex wave motion on a six degree-of-freedom platform that included pitch, roll and heave at provocative stimulus frequencies (0.1-0.25 Hz) while seated in an illuminated cabin deprived of external visual cues. Motion sickness symptoms were compared across treatment and placebo control sessions counterbalanced across subjects and separated by at least one week. The time-to-motion sickness endpoint was based on severe malaise, defined as symptom score of ≥8 points using the Pensacola Diagnostic Index [1]. The bioavailability of scopolamine for each session was estimated from plasma concentrations obtained every 15 min[2]. Side effects during the treatment session were minimal, and performance was not impaired on a test battery including motion perception tracking, tablet-based eye-hand coordination and psychomotor vigilance testing. The plasma concentration remained near-peak levels throughout the 45 min motion sickness testing for most subjects. The percentile ranking on the Motion Sickness Susceptibility Questionnaire [MSSQ, 3]was moderately correlated with the motion sickness time-to-endpoint during the placebo control session (rho = –0.3, p=0.056). Seventeen subjects did not reach an endpoint during their placebo session and were eliminated from subsequent analysis. Another subject was excluded due to insufficient plasma concentration during the treatment session. For the remaining 12 subjects, the change in time-to-motion sickness endpoint between placebo and treatment sessions was moderately correlated with plasma concentration (rho =0.48, p = 0.056), improving on average 4.4 ± 18.4 min, mean ± std with Inscop versus placebo. Our results are consistent with previous findings that intranasal delivery of scopolamine can be effective at reducing motion sickness symptoms with minimal cognitive or sedative side effects. Future work is needed to optimize the delivery of Inscop for rescue (treatment) of symptoms following g-transitions as one of the key advantages of this formulation is self-administration in a suited environment. We will also explore how the combination of Inscop with non-pharmaceutical sensory aids, e.g., vibrotactile feedback of Earth vertical, may further mitigate motion sickness and improve task performance.

S J Wood

Steady-State Pursuit Is Driven by Object Motion Rather Than the Vector Average of Local Motions

We have previously shown that humans can pursue the motion of objects whose trajectories can be recovered only by spatio-temporal integration of local motion signals. We now explore the integration rule used to derive the target-motion signal driving pursuit. We measured the pursuit response of 4 observers (2 naive) to the motion of a line-figure diamond viewed through two vertical bar apertures (0.2 cd/square m). The comers were always occluded so that only four line segments (93 cd/square m) were visible behind the occluding foreground (38 cd/square m). The diamond was flattened (40 & 140 degree vertex angles) such that vector averaging of the local normal motions and vertical integration (e.g. IOC) yield very I or different predictions, analogous to using a Type II plaid. The diamond moved along Lissajous-figure trajectories (Ax = Ay = 2 degrees; TFx = 0.8 Hz; TFy = 0.4 Hz). We presented only 1.25 cycles and used 6 different randomly interleaved initial relative phases to minimize the role of predictive strategies. Observers were instructed to track the diamond and reported that its motion was always coherent (unlike type II plaids). Saccade-free portions of the horizontal and vertical eye-position traces sampled at 240 Hz were fit by separate sinusoids. Pursuit gain with respect to the diamond averaged 0.7 across subjects and directions. The ratio of the mean vertical to horizontal amplitude of the pursuit response was 1.7 +/- 0.7 averaged across subjects (1SD). This is close to the prediction of 1.0 from vertical motion-integration rules, but far from 7.7 predicted by vector averaging and infinity predicted by segment- or terminator-tracking strategies. Because there is no retinal motion which directly corresponds to the diamond's motion, steady-state pursuit of our "virtual" diamond is not closed-loop in the traditional sense. Thus, accurate pursuit is unlikely to result simply from local retinal negative feedback. We conclude that the signal driving steady-state pursuit is not the vector average of local motion signals, but rather a more vertical estimate of object motion, derived in extrastriate cortical areas beyond V1, perhaps NIT or MST.

Stone, Leland S.

Translational Vestibulo-Ocular Reflex and Motion Perception During Interaural Linear Acceleration: Comparison of Different Motion Paradigms

The neural mechanisms to resolve ambiguous tilt-translation motion have been hypothesized to be different for motion perception and eye movements. Previous studies have demonstrated differences in ocular and perceptual responses using a variety of motion paradigms, including Off-Vertical Axis Rotation (OVAR), Variable Radius Centrifugation (VRC), translation along a linear track, and tilt about an Earth-horizontal axis. While the linear acceleration across these motion paradigms is presumably equivalent, there are important differences in semicircular canal cues. The purpose of this study was to compare translation motion perception and horizontal slow phase velocity to quantify consistencies, or lack thereof, across four different motion paradigms. Twelve healthy subjects were exposed to sinusoidal interaural linear acceleration between 0.01 and 0.6 Hz at 1.7 m/s/s (equivalent to 10 tilt) using OVAR, VRC, roll tilt, and lateral translation. During each trial, subjects verbally reported the amount of perceived peak-to-peak lateral translation and indicated the direction of motion with a joystick. Binocular eye movements were recorded using video-oculography. In general, the gain of translation perception (ratio of reported linear displacement to equivalent linear stimulus displacement) increased with stimulus frequency, while the phase did not significantly vary. However, translation perception was more pronounced during both VRC and lateral translation involving actual translation, whereas perceptions were less consistent and more variable during OVAR and roll tilt which did not involve actual translation. For each motion paradigm, horizontal eye movements were negligible at low frequencies and showed phase lead relative to the linear stimulus. At higher frequencies, the gain of the eye movements increased and became more inphase with the acceleration stimulus. While these results are consistent with the hypothesis that the neural computational strategies for motion perception and eye movements differ, they also indicate that the specific motion platform employed can have a significant effect on both the amplitude and phase of each.

Beaton, K. H.

Human comfort response to dominant random motions in longitudinal modes of aircraft motion

The effects of random vertical and longitudinal accelerations and pitching velocity passenger ride comfort responses were examined on the NASA Langley Visual Motion Simulator. Effects of power spectral density shape were studied for motions where the peak was between 0 and 2 Hz. The subjective rating data and the physical motion data obtained are presented without interpretation or detailed analysis. There existed motions in all other degrees of freedom as well as the particular pair of longitudinal airplane motions studied. These unwanted motions, caused by the characteristics of the simulator may have introduced some interactive effects on passenger responses.

Stone, R. W., Jr.

Motion sickness - Acquisition and retention of adaptation effects compared in three motion environments

The acquisition and retention of adaptation effects in motion sickness was invetigated using a sudden-stop vestibulovisual interaction test for measuring susceptibility to motion sickness (Graybiel and Lackner, 1980). The test procedure included four successive assessments that provide not only an index of susceptibility to motion sickness but also the rates of acquisition and decay of adaptation effects. The 14 subjects who had participated in this test had previously served as subjects in parabolic flight experiments and seven of them had also taken part in the assessment of antimotion-sickness remedies in a slow rotation room. A study was conducted to determine whether these subjects' rates of acquisition and decay of adaptation to stressful motion represent consistent general features of their response across motion environments. It is found that an individual's rates of acquiring and losing adaptation are quite consistent in very different situations. In addition, the pattern of results indicate modifications of the sudden-stop vestibulovisual test that should increase its effectiveness as a motion-sickness screening procedure, both for orbital flight and for terrestrial conditions.

Graybiel, A.

An Analytical Comparison of the Fidelity of "Large Motion" Versus "Small Motion" Flight Simulators in a Rotorcraft Side-Step Task

This paper presents an analytical and experimental methodology for studying flight simulator fidelity. The task was a rotorcraft bob-up/down maneuver in which vertical acceleration constituted the motion cue. The task considered here is aside-step maneuver that differs from the bob-up one important way: both roll and lateral acceleration cues are available to the pilot. It has been communicated to the author that in some Verticle Motion Simulator (VMS) studies, the lateral acceleration cue has been found to be the most important. It is of some interest to hypothesize how this motion cue associated with "outer-loop" lateral translation fits into the modeling procedure where only "inner-loop " motion cues were considered. This Note is an attempt at formulating such an hypothesis and analytically comparing a large-motion simulator, e.g., the VMS, with a small-motion simulator, e.g., a hexapod.

Hess, Ronald A.

Long-term motion in a restricted problem of rotational motion

A method of general perturbations, based on the use of Lie series to generate approximate canonical transformations, is applied to study the long-term effects of gravity-gradient torque and orbital evolution on the rotational motion of a triaxial, rigid satellite. The center of mass of the satellite is constrained to move in an elliptic orbit about an attracting point mass. The orbit, which has a constant inclination, is constrained to precess and spin with constant rates. The method of general perturbations is used to obtain the Hamiltonian for the nonresonant secular and long-period rotational motion of the satellite to second order in n/omega sub 0, where n is the orbital mean motion of the center of mass and omega sub 0 is a reference value of the magnitude of the satellite's rotational angular velocity. The differential equations derivable from the transformed Hamiltonian are integrable, and the solution for the long-term motion may be expressed in terms of Jacobian elliptic functions and elliptic integrals. Geometrical aspects of the long-term rotational motion are discussed, and a comparison of theoretical results with observations is made.

Cochran, J. E.

Human comfort response to random motions with combined yawing and rolling motions

The effects of random yawing and rolling velocities on passenger ride comfort responses were examined on a visual motion simulator. The effects of power spectral density shape and frequency ranges of peak power from 0 to 2 Hz were studied. The subjective rating data and the physical motion data obtained are presented. No attempt at interpretation or detailed analysis of the data is made. There existed during this study motions in all other degrees of freedom as well as the yawing and rolling motions, because of the characteristics of the simulator. These unwanted motions may have introduced some interactive effects on passenger responses which should be considered in any analysis of the data.

Stone, R. W., Jr.

Human comfort response to random motions with a dominant pitching motion

The effects of random pitching velocities on passenger ride comfort response were examined on the NASA Langley Visual Motion Simulator. The effects of power spectral density shape and frequency ranges from 0 to 2 Hz were studied. The subjective rating data and the physical motion data obtained are presented. No attempt at interpretation or detailed analysis of the data is made. Motions in all degrees of freedom existed as well as the intended pitching motion, because of the characteristics of the simulator. These unwanted motions may have introduced some interactive effects on passenger responses which should be considered in any analysis of the data.

Stone, R. W., Jr.

Self-Motion Perception and Motion Sickness

Motion sickness typically is considered a bothersome artifact of exposure to passive motion in vehicles of conveyance. This condition seldom has significant impact on the health of individuals because it is of brief duration, it usually can be prevented by simply avoiding the eliciting condition and, when the conditions that produce it are unavoidable, sickness dissipates with continued exposure. The studies conducted examined several aspects of motion sickness in animal models. A principle objective of these studies was to investigate the neuroanatomy that is important in motion sickness with the objectives of examining both the utility of putative models and defining neural mechanisms that are important in motion sickness.

Robert A Fox

Motion Cueing Algorithm Development: New Motion Cueing Program Implementation and Tuning

A computer program has been developed for the purpose of driving the NASA Langley Research Center Visual Motion Simulator (VMS). This program includes two new motion cueing algorithms, the optimal algorithm and the nonlinear algorithm. A general description of the program is given along with a description and flowcharts for each cueing algorithm, and also descriptions and flowcharts for subroutines used with the algorithms. Common block variable listings and a program listing are also provided. The new cueing algorithms have a nonlinear gain algorithm implemented that scales each aircraft degree-of-freedom input with a third-order polynomial. A description of the nonlinear gain algorithm is given along with past tuning experience and procedures for tuning the gain coefficient sets for each degree-of-freedom to produce the desired piloted performance. This algorithm tuning will be needed when the nonlinear motion cueing algorithm is implemented on a new motion system in the Cockpit Motion Facility (CMF) at the NASA Langley Research Center.

Houck, Jacob A.

A Fully Nonlinear, Dynamically Consistent Numerical Model for Solid-Body Ship Motion. I. Ship Motion with Fixed Heading

In this paper, we describe the details of our numerical model for simulating ship solidbody motion in a given environment. In this model, the fully nonlinear dynamical equations governing the time-varying solid-body ship motion under the forces arising from ship wave interactions are solved with given initial conditions. The net force and moment (torque) on the ship body are directly calculated via integration of the hydrodynamic pressure over the wetted surface and the buoyancy effect from the underwater volume of the actual ship hull with a hybrid finite-difference/finite-element method. Neither empirical nor free parametrization is introduced in this model, i.e. no a priori experimental data are needed for modelling. This model is benchmarked with many experiments of various ship hulls for heave, roll and pitch motion. In addition to the benchmark cases, numerical experiments are also carried out for strongly nonlinear ship motion with a fixed heading. These new cases demonstrate clearly the importance of nonlinearities in ship motion modelling.

Lin, Ray-Quing

Charged particle motions in a magnetic field which reduce to motions in a potential

If the Hamiltonian for the motion of a charged particle in a magnetic field has one or more cyclic coordinates it may often be viewed as representing the motion of a particle subject to a potential V. The use of V provides qualitative insight about the motion even in some cases where a solution of the motion cannot be obtained. Several examples using this concept are reviewed and discussed.

Stern, D. P.

Head movements in non-terrestrial force environments elicit motion sickness - Implications for the etiology of space motion sickness

Space motion sickness has become an operational concern in manned space flight. Considerable evidence exists that head movements in free fall, especially pitch movements, are provocative until adaptation occurs. The question arises whether space motion sickness is an unique nosological entity or is due to body movements in a nonterrestrial force environment, a force environment for which the body's dynamic sensory-motor adaptions to 1 G are no longer appropriate. To evaluate this issue, subjects were asked to make controlled head movements during exposure to high gravitoinertial force levels, 1.8-2.0 G, in parabolic flight maneuvers. Head movements in pitch with eyes open were most evocative of motion sickness, yaw movements with eyes covered were least provocative. This pattern is identical to that which occurs when the same types of head movements are made in the free fall phase of parabolic maneuvers. It appears that space motion sickness is the consequence of prolonged exposure to a nonterrestrial force background rather than of exposure to free fall per se.

Lackner, J. R.

Dual motion valve with single motion input

A dual motion valve includes two dual motion valve assemblies with a rotary input which allows the benefits of applying both rotary and axial motion to a rotary sealing element with a plurality of ports. The motion of the rotary sealing element during actuation provides axial engagement of the rotary sealing element with a stationary valve plate which also has ports. Fluid passages are created through the valve when the ports of the rotary sealing element are aligned with the ports of the stationary valve plate. Alignment is achieved through rotation of the rotary sealing element with respect to the stationary valve plate. The fluid passages provide direct paths which minimize fluid turbulence created in the fluid as it passes through the valve.

Belew, Robert

Quantitative assessment of human motion using video motion analysis

In the study of the dynamics and kinematics of the human body a wide variety of technologies has been developed. Photogrammetric techniques are well documented and are known to provide reliable positional data from recorded images. Often these techniques are used in conjunction with cinematography and videography for analysis of planar motion, and to a lesser degree three-dimensional motion. Cinematography has been the most widely used medium for movement analysis. Excessive operating costs and the lag time required for film development, coupled with recent advances in video technology, have allowed video based motion analysis systems to emerge as a cost effective method of collecting and analyzing human movement. The Anthropometric and Biomechanics Lab at Johnson Space Center utilizes the video based Ariel Performance Analysis System (APAS) to develop data on shirtsleeved and space-suited human performance in order to plan efficient on-orbit intravehicular and extravehicular activities. APAS is a fully integrated system of hardware and software for biomechanics and the analysis of human performance and generalized motion measurement. Major components of the complete system include the video system, the AT compatible computer, and the proprietary software.

Probe, John D.

Motion-Contrast Sensitivity: Visibility of Motion Gradients of Various Spatial Frequencies

The purpose of our experiments was to estimate basic sensitivity to motion gradients and to evaluate the evidence for second-order integration and differentiation of motion signals. We measured sensitivity to spatially sinusoidal contrast modulation between two oppositely moving bandpass-filtered noise images. The motion-contrast sensitivity function, defined as the inverse of threshold modulation amplitude as a function of modulation spatial frequency, was bandpass in shape with declines at both highest and lowest frequencies. The functions for three noise spatial frequencies had approximately the same shape when modulation frequency was expressed as a fraction of noise frequency. We compared the data with a model in which linear motion filters, whose outputs are squared or rectified, are followed by a second stage of excitatory or inhibitory pooling. The data are consistent with a model in which (1) all excitatory pooling occurs at the linear stage and (2) the second stage contains a large inhibitory pooling area, with a radius approximately eight times that of the linear receptive field.

Watson, Andrew B.