Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion profiles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigation of Needle Motion Profile Effect on Diesel Spray in Near-Nozzle Field

A variety of needle-motion profiles are used in diesel injectors. However, it is unclear what the underlying mechanism is to determine the needle-motion profiles and how they affect the spray dynamics. It has been of significant interest to examine how the spray dynamics will change if only altering the needle valve opening speed or closing speed while all other parameters are kept the same. The different needle-motion profiles were obtained using a piezo nozzle (Nozzle #P) and a solenoid nozzle (Nozzle #S), which have identical nozzle geometry. By utilizing the X-ray imaging technique, it was observed that the average needle valve speed of Nozzle #P was 51% higher at the opening stage but 17% lower at the closing stage than Nozzle #S. When the needle valve lift is low (approximately 200 μm), the needle valve opening speed has a crucial effect on spray dynamics. The faster needle valve opening of Nozzle #P results in a 42% larger spray spreading angle and 34% lower spray velocity at the downstream field. The spray dynamics may be controllable by properly designing the needle-motion profiles in the scenarios of the low needle lifts. However, when the needle valve is sufficiently open (approximately over 200 μm), almost identical spray characteristics were observed regardless of the needle-motion profiles.

47 OTHER INSTRUMENTATION↗

TH-EF-BRA-06: A Novel Retrospective 3D K-Space Sorting 4D-MRI Technique Using a Radial K-Space Acquisition MRI Sequence

Purpose: Current retrospective 4D-MRI provides superior tumor-to-tissue contrast and accurate respiratory motion information for radiotherapy motion management. The developed 4D-MRI techniques based on 2D-MRI image sorting require a high frame-rate of the MR sequences. However, several MRI sequences provide excellent image quality but have low frame-rate. This study aims at developing a novel retrospective 3D k-space sorting 4D-MRI technique using radial k-space acquisition MRI sequences to improve 4D-MRI image quality and temporal-resolution for imaging irregular organ/tumor respiratory motion. Methods: The method is based on a RF-spoiled, steady-state, gradient-recalled sequence with minimal echo time. A 3D radial k-space data acquisition trajectory was used for sampling the datasets. Each radial spoke readout data line starts from the 3D center of Field-of-View. Respiratory signal can be extracted from the k-space center data point of each spoke. The spoke data was sorted based on its self-synchronized respiratory signal using phase sorting. Subsequently, 3D reconstruction was conducted to generate the time-resolved 4D-MRI images. As a feasibility study, this technique was implemented on a digital human phantom XCAT. The respiratory motion was controlled by an irregular motion profile. To validate using k-space center data as a respiratory surrogate, we compared it with the XCAT input controlling breathing profile. Tumor motion trajectories measured on reconstructed 4D-MRI were compared to the average input trajectory. The mean absolute amplitude difference (D) was calculated. Results: The signal extracted from k-space center data matches well with the input controlling respiratory profile of XCAT. The relative amplitude error was 8.6% and the relative phase error was 3.5%. XCAT 4D-MRI demonstrated a clear motion pattern with little serrated artifacts. D of tumor trajectories was 0.21mm, 0.23mm and 0.23mm in SI, AP and ML directions, respectively. Conclusion: A novel retrospective 3D k-space sorting 4D-MRI technique has been developed and evaluated on human digital phantom. NIH (1R21CA165384-01A1)

60 APPLIED LIFE SCIENCES↗

Optimizing the fuel efficiency of an opposed piston engine for electric power generation

This paper investigates the optimal crankshaft motion for an opposed piston (OP) engine in a novel hybrid architecture to maximize fuel efficiency. The OP engine was selected for this work due to its inherent thermodynamic benefits and the balanced nature of the engine which can achieve downsizing through reducing the number of cylinders rather than the individual cylinder volume. The typical geartrain required on an OP engine was exchanged for two electric motors, reducing friction loss and decoupling the crankshafts. Using the motors to control the crankshaft motion profiles, this architecture introduces capabilities to dynamically vary compression ratio, combustion volume, and scavenging dynamics. To leverage these opportunities, an optimization scheme was developed utilizing nonlinear optimization of a 0-D model to compute the crankshaft motion profile that maximizes the work generated by the system. This optimization was then iteratively coupled with a high fidelity model which supplies the cylinder flow boundary conditions. This iterative approach reduces the model complexity used in the optimal control problem (OCP) while capturing the gas exchange dynamics critical to the 2-stroke cycle of the OP engine. By using the rate of change of motor torque as the input to the OCP, the torque fluctuation in a single cycle can be limited to ensure tracking feasibility. The results show crankshaft velocity slows during the compression stroke and conversely accelerates during the expansion stroke, reducing the peak motor torque required for control and thus reducing the motor losses. The extended residence time at top dead center, however, leads to an increase in heat transfer, illustrating the trade-off between the work extraction efficiency and the indicated engine efficiency.

Engineering↗

THE EFFECT OF UNRESOLVED BINARIES ON GLOBULAR CLUSTER PROPER-MOTION DISPERSION PROFILES

High-precision kinematic studies of globular clusters (GCs) require an accurate knowledge of all possible sources of contamination. Among other sources, binary stars can introduce systematic biases in the kinematics. Using a set of Monte Carlo cluster simulations with different concentrations and binary fractions, we investigate the effect of unresolved binaries on proper-motion dispersion profiles, treating the simulations like Hubble Space Telescope proper-motion samples. Since GCs evolve toward a state of partial energy equipartition, more-massive stars lose energy and decrease their velocity dispersion. As a consequence, on average, binaries have a lower velocity dispersion, since they are more-massive kinematic tracers. We show that, in the case of clusters with high binary fractions (initial binary fractions of 50%) and high concentrations (i.e., closer to energy equipartition), unresolved binaries introduce a color-dependent bias in the velocity dispersion of main-sequence stars of the order of 0.1–0.3 km s{sup −1} (corresponding to 1%−6% of the velocity dispersion), with the reddest stars having a lower velocity dispersion, due to the higher fraction of contaminating binaries. This bias depends on the ability to distinguish binaries from single stars, on the details of the color–magnitude diagram and the photometric errors. We apply our analysis to the HSTPROMO data set of NGC 7078 (M15) and show that no effect ascribable to binaries is observed, consistent with the low binary fraction of the cluster. Our work indicates that binaries do not significantly bias proper-motion velocity-dispersion profiles, but should be taken into account in the error budget of kinematic analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-194: Dynamic Tumor Tracking End-To-End Testing Using a 4D Thorax Phantom and EBT3 Films

Purpose: To quantify the Vero linac dosimetric accuracy of the tumor dynamic tracking treatment using EBT3 film embedded in a 4D thorax phantom. Methods: A dynamic thorax phantom with tissue equivalent materials and a film insert were used in this study. The thorax phantom was scanned in 4DCT mode with a viscoil embedded in its film insert composed of lung equivalent material. Dynamic tracking planning was performed using the 50% phase CT set with 5 conformal beams at gantry angles of 330, 15, 60, 105 and 150 degrees. Each field is a 3cm by 3cm square centered at viscoil since there was no solid mass target. Total 3 different 1–2cos4 motion profiles were used with varied motion magnitude and cycle frequency. Before treatment plan irradiation, a 4D motion model of the target was established using a series of acquired fluoroscopic images and infrared markers motion positions. During irradiation, fluoroscopic image monitoring viscoil motion was performed to verify model validity. The irradiated films were scanned and the dose maps were compared to the planned Monte Carlo dose distributions. Gamma analyses using 3%–3mm, 2%–3mm, 3%–2mm, 2%–2mm criteria were performed and presented. Results: For each motion pattern, a 4D motion model was built successfully and the target tracking performance was verified with fluoroscopic monitoring of the viscoil motion and its model predicted locations. The film gamma analysis showed the average pass rates among the 3 motion profiles are 98.14%, 96.2%, 91.3% and 85.61% for 3%–3mm, 2%–3mm, 3%–2mm, 2%–2mm criteria. Conclusion: Target dynamic tracking was performed using patient-like breathing patterns in a 4D thorax phantom with EBT3 film insert and a viscoil. There was excellent agreement between acquired and planned dose distributions for all three target motion patterns. This study performed end-to-end testing and verified the treatment accuracy of tumor dynamic tracking.

60 APPLIED LIFE SCIENCES↗

Analytical Solution to the Pneumatic Transient Rod System at ACRR

The ACRR pulse is pneumatically driven by nitrogen in a system of pipes, valves and hoses up to the connection of the pneumatic system and mechanical linkages of the transient rod (TR). The main components of the TR pneumatic system are the regulator, accumulator, solenoid valve and piston-cylinder assembly. The purpose of this analysis is to analyze the flow of nitrogen through the TR pneumatic system in order to develop a motion profile of the piston during the pulse and be able to predict the pressure distributions inside both the cylinder and accumulators. The predicted pressure distributions will be validated against pressure transducer data, while the motion profile will be compared to proximity switch data. By predicting the motion of the piston, pulse timing will be determined and provided to the engineers/operators for verification. The motion profile will provide an acceleration distribution to be used in Razorback to more accurately predict reactivity insertion into the system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initial Characterization of the NREL Large-Amplitude Motion Platform

The Large Amplitude Motion Platform (LAMP) at NREL represents a significant advancement in the controlled testing of Wave Energy Converters (WECs) under laboratory conditions. Originally designed by E2M as a six-degree-of-freedom (DOF) Stewart platform for flight simulation, LAMP has been adapted by NREL to facilitate the mounting and evaluation of WECs. This adaptation enables dry testing of WECs using motion profiles similar to the ocean, facilitating the iterative design, testing, and validation of WEC performance prior to ocean deployments. This report presents the initial work completed to characterize LAMP, with particular emphasis on its stability and operational capabilities across various single and multi-degree-of-freedom (DOF) motion profiles. The report includes planned comparisons at three distinct mass payloads, aimed at assessing the platform's positional accuracy, frequency response, and endurance over extended runtime periods. These experimental tests are critical for establishing the platform's limitations and ensuring that the data generated during WEC validation is both accurate and reproducible. The outcomes of this study not only contribute to a deeper understanding of LAMP's capabilities but also lay the groundwork for future advancements in WEC testing methodologies. By providing robust and reliable performance data within a controlled laboratory setting, the findings are expected to significantly enhance the development and commercialization of marine energy technologies. This report presents the initial findings of the LAMP Characterization work and proposed steps to further understand and characterize LAMP. Data collected during this work can be found on MHKDR at: https://mhkdr.openei.org/submissions/602 Note that this report shares the measured/found instantaneous maximum operating range of LAMP. For most applications the maximum operating range cannot be used for system health and longevity. The operating range and capabilities of LAMP will be evaluated on a case-by-case basis, single-DOF position, velocity, and acceleration values presented in Table 4a-c, and Table 5 should be taken as instantaneous absolute maximum values. Future use of LAMP will likely be limited to smaller values.

16 TIDAL AND WAVE POWER↗

SU-F-I-58: Image Quality Comparisons of Different Motion Magnitudes and TR Values in MR-PET

Purpose: The aim of this work is to evaluate the accuracy and sensitivity of a respiratory-triggered MR-PET protocol in detecting four different sized lesions at two different magnitudes of motion, with two different TR values, using a novel PET-MR-CT compatible respiratory motion phantom. Methods: The eight-compartment torso phantom was setup adjacent to the motion stage, which moved four spherical compartments (28, 22, 17, 10 mm diameter) in two separate (1 and 2 cm) linear motion profiles, simulating a 3.5 second respiratory cycle. Scans were acquired on a 3T MR-PET system (Biograph mMR; Siemens Medical Solutions, Germany). MR measurements were taken with: 1) Respiratory-triggered T2-weighted turbo spin echo (BLADE) sequence in coronal orientation, and 2) Real-time balanced steady-state gradient echo sequence (TrueFISP) in coronal and sagittal planes. PET was acquired simultaneously with MR. Sphere geometries and motion profiles were measured and compared with ground truths for T2 BLADE-TSE acquisitions and real time TrueFISP images. PET quantification and geometry measurements were taken using standardized uptake values, voxel intensity plots and were compared with known values, and examined alongside MR-based attenuation maps. Contrast and signal-to-noise ratios were also compared for each of the acquisitions as functions of motion range and TR. Results: Comparison of lesion diameters indicate the respiratory triggered T2 BLADE-TSE was able to maintain geometry within −2 mm for 1 cm motion for both TR values, and within −3.1 mm for TR = 2000 ms at 2 cm motion. Sphere measurements in respiratory triggered PET images were accurate within +/− 5 mm for both ranges of motion for 28, 22, and 17 mm diameter spheres. Conclusion: Hybrid MR-PET systems show promise in imaging lung cancer in non-compliant patients, with their ability to acquire both modalities simultaneously. However, MR-based attenuation maps are still susceptible to motion derived artifacts and pose the potential to affect PET accuracy.

60 APPLIED LIFE SCIENCES↗

Lifecycle of updrafts and mass flux in isolated deep convection over the Amazon rainforest: insights from cell tracking

Long-term observations of deep convective cloud (DCC) vertical velocity and mass flux were collected during the Observations and Modelling of the Green Ocean Amazon (GoAmazon2014/5) experiment. Precipitation echoes from a surveillance weather radar near Manaus, Brazil, are tracked to identify and evaluate the isolated DCC lifecycle evolution during the dry and wet seasons. A radar wind profiler (RWP) provides precipitation and air motion profiles to estimate the vertical velocity, mass flux, and mass transport rates within overpassing DCC cores as a function of the tracked cell lifecycle stage. The average radar reflectivity factor (Z), DCC area (A), and surface rainfall rate (R) increased with DCC lifetime as convective cells were developing, reached a peak as the cells matured, and decreased thereafter as cells dissipated. As the convective cells mature, cumulative DCC properties exhibit stronger updraft behaviors with higher upward mass flux and transport rates above the melting layer (compared with initial and later lifecycle stages). In comparison, developing DCCs have the lowest Z associated with weak updrafts, as well as negative mass flux and transport rates above the melting layer. Over the DCC lifetime, the height of the maximum downward mass flux decreased, whereas the height of the maximum net mass flux increased. During the dry season, the tracked DCCs had higher Z, propagation speed, and DCC area, and were more isolated spatially compared with the wet season. Dry season DCCs exhibit higher Z, mass flux, and mass transport rate while developing, whereas wet season DCCs exhibit higher Z, mass flux, and mass transport rates at later stages.

54 ENVIRONMENTAL SCIENCES↗

HERO WEC Belt Test Data

The following submission includes raw and processed data from the 2024 Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC) belt tests conducted using NREL's Large Amplitude Motion Platform (LAMP). A description of the motion profiles run during testing can be found in the run log document. Data was collected using NREL's Modular Ocean Data AcQuisition (MODAQ) system in the form of TDMS files. Data was then processed using Python and MATLAB and converted to MATLAB workspace, parquet, and csv file formats. During Data processing, a low pass filter was applied to each array and the arrays were then resampled to common 10Hz timestamps. A MATLAB data viewer script is provided to quickly visualize these data sets. The following arrays are contained in each test data file: - Time: Unix seconds timestamp - Test_Time: Time in seconds since beginning of test - POS_OS_1001: Encoder position in degrees (the encoder is located on the secondary shaft of the spring return and is driven by the winch after a 4.5:1 gear reduction) - LC_ST_1001: Anchor load cell data in lbf - PRESS_OS_2002: Air spring pressure in psi This data set has been developed by the National Renewable Energy Laboratory, operated by Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

Improving best-phase image quality in cardiac CT by motion correction with MAM optimization

Purpose: Research in image reconstruction for cardiac CT aims at using motion correction algorithms to improve the image quality of the coronary arteries. The key to those algorithms is motion estimation, which is currently based on 3-D/3-D registration to align the structures of interest in images acquired in multiple heart phases. The need for an extended scan data range covering several heart phases is critical in terms of radiation dose to the patient and limits the clinical potential of the method. Furthermore, literature reports only slight quality improvements of the motion corrected images when compared to the most quiet phase (best-phase) that was actually used for motion estimation. In this paper a motion estimation algorithm is proposed which does not require an extended scan range but works with a short scan data interval, and which markedly improves the best-phase image quality. Methods: Motion estimation is based on the definition of motion artifact metrics (MAM) to quantify motion artifacts in a 3-D reconstructed image volume. The authors use two different MAMs, entropy, and positivity. By adjusting the motion field parameters, the MAM of the resulting motion-compensated reconstruction is optimized using a gradient descent procedure. In this way motion artifacts are minimized. For a fast and practical implementation, only analytical methods are used for motion estimation and compensation. Both the MAM-optimization and a 3-D/3-D registration-based motion estimation algorithm were investigated by means of a computer-simulated vessel with a cardiac motion profile. Image quality was evaluated using normalized cross-correlation (NCC) with the ground truth template and root-mean-square deviation (RMSD). Four coronary CT angiography patient cases were reconstructed to evaluate the clinical performance of the proposed method. Results: For the MAM-approach, the best-phase image quality could be improved for all investigated heart phases, with a maximum improvement of the NCC value by 100% and of the RMSD value by 81%. The corresponding maximum improvements for the registration-based approach were 20% and 40%. In phases with very rapid motion the registration-based algorithm obtained better image quality, while the image quality of the MAM algorithm was superior in phases with less motion. The image quality improvement of the MAM optimization was visually confirmed for the different clinical cases. Conclusions: The proposed method allows a software-based best-phase image quality improvement in coronary CT angiography. A short scan data interval at the target heart phase is sufficient, no additional scan data in other cardiac phases are required. The algorithm is therefore directly applicable to any standard cardiac CT acquisition protocol.

60 APPLIED LIFE SCIENCES↗

Phantom and Clinical Study of Differences in Cone Beam Computed Tomographic Registration When Aligned to Maximum and Average Intensity Projection

Purpose: To determine whether maximum or average intensity projection (MIP or AIP, respectively) reconstructed from 4-dimensional computed tomography (4DCT) is preferred for alignment to cone beam CT (CBCT) images in lung stereotactic body radiation therapy. Methods and Materials: Stationary CT and 4DCT images were acquired with a target phantom at the center of motion and moving along the superior–inferior (SI) direction, respectively. Motion profiles were asymmetrical waveforms with amplitudes of 10, 15, and 20 mm and a 4-second cycle. Stationary CBCT and dynamic CBCT images were acquired in the same manner as stationary CT and 4DCT images. Stationary CBCT was aligned to stationary CT, and the couch position was used as the baseline. Dynamic CBCT was aligned to the MIP and AIP of corresponding amplitudes. Registration error was defined as the SI deviation of the couch position from the baseline. In 16 patients with isolated lung lesions, free-breathing CBCT (FBCBCT) was registered to AIP and MIP (64 sessions in total), and the difference in couch shifts was calculated. Results: In the phantom study, registration errors were within 0.1 mm for AIP and 1.5 to 1.8 mm toward the inferior direction for MIP. In the patient study, the difference in the couch shifts (mean, range) was insignificant in the right-left (0.0 mm, ≤1.0 mm) and anterior–posterior (0.0 mm, ≤2.1 mm) directions. In the SI direction, however, the couch position significantly shifted in the inferior direction after MIP registration compared with after AIP registration (mean, −0.6 mm; ranging 1.7 mm to the superior side and 3.5 mm to the inferior side, P=.02). Conclusions: AIP is recommended as the reference image for registration to FBCBCT when target alignment is performed in the presence of asymmetrical respiratory motion, whereas MIP causes systematic target positioning error.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design of a pilot scale directly irradiated, high temperature, and low pressure moving particle cavity chamber for metal oxide reduction

Recently a novel design concept of a reactor—the cascading pressure reactor—for the thermochemical fuel production, using a solar-driven redox cycle, was proposed. In this concept, thermal reduction of metal oxide particles is completed in multiple stages, at successively lower pressures. This leads to an order of magnitude decrease in the pumping power demand as compared to a single stage, which in turn increases the solar to fuel efficiency. An important step in the process is the transfer of heat in the form of concentrated solar radiation to the particles, while providing reducing conditions in the space surrounding the particles. In this context, a novel system for heating and reducing particles, with a focus on operating at the small prototype scale (below 20 kW), is investigated. The key goals of the system are continuous operation, uniform heating of the reactive material, the ability to heat reactive material to 1723 K or higher, and flexibility of control. These criteria have led to the conceptual design of a continuous thin-layer particle conveyor, contained in an apertured, windowed cavity and enclosed in a vacuum chamber. This chamber, in combination with a water-splitting chamber and other system components, allows the possibility of testing multiple redox materials without any significant change in the reactor design. The present work shows a potential design for the proposed component, feasibility tests of the physics of moving particles with relevant materials, and series of interconnected numerical models and calculations that can be used to size such a system for the appropriate scales of power and mass flow rates. The use of a unified design strategy has led to efficient development of the system. Experimental investigations of the horizontal motion plate allowed effective determination of motion profiles and bed uniformity. We note the most important factors determined through the modeling effort were the aperture diameter, which serves as the coupling point between the solar simulator lamp array and the cavity particle heating, and the particle bed thickness, which has a strong effect on the outlet temperature of the particles.

42 ENGINEERING↗

Mechanical joining with self piercing solid-rivets at elevated tool velocities

In the present paper the influence of a higher setting velocity in the joining process of self piercing solid-rivets is shown. In the conventional process tool velocities well below 1 m/s are common. The present research results show the potential of increasing them in the range of about 5 m/s. The results are especially relevant for joining high-strength steels. These steel sheets often cause problems in the process of riveting mixed materials, e. g. aluminium-steel compound. The high strength of the steel sometimes leads to undesirable material flow in the joining process or unwanted burr development. These effects, which are described in detail in the article, can be reduced significantly for the investigated cases by the use of higher tool velocities. Using a high speed camera and a load cell, a test setup based on a drop tower was realized. It was used to time the force signals and the motion profile of the high speed riveting process. The results of the force analysis show an oscillating force progression. Within a numerical research the principal effects influencing the results of the riveting process can be shown. It was found that the pulse-like force transmission between riveting machine and punch, results in various vibrations especially of long and thin tool parts. Hence the rivet penetrates the sheet metal with non-uniform velocities. As a result the early indentation of die into the lower sheet metal at the beginning of the process is reduced, so that the final process step provides a sufficient material flow into the circular rivet groove. A strain-rate dependent process model with elastic tool properties and consideration of inertia effects is presented.

36 MATERIALS SCIENCE↗

An Approach to Realize Generalized Optimal Motion Primitives Using Physics Informed Neural Networks

Autonomous manipulation is a challenging problem in field robotics due to uncertainty in object properties, constraints, and coupling phenomenon with robot control systems. Humans learn motion primitives over time to effectively interact with the environment. We postulate that autonomous manipulation can be enabled by basic sets of motion primitives as well, but do not necessitate mimicking human motion primitives. Here, this work presents an approach to generalized optimal motion primitives using physics-informed neural networks. Our simulated and experimental results demonstrate that optimality is notionally maintained where the mean maximum observed final position percent error was 0.564% and the average mean error for all the trajectories was 1.53%. These results indicate that notional generalization is attained using a physics-informed neural network approach that enables near optimal real-time adaptation of primitive motion profiles.

97 MATHEMATICS AND COMPUTING↗

ARM - Midlatitude Continental Convective Clouds Experiment (MC3E): Multi-Frequency Profilers, Vertical Air Motion (williams-vertair)

This data was collected by the NOAA 449-MHz and 2.8-GHz profilers in support of the Department of Energy (DOE) and NASA sponsored Mid-latitude Continental Convective Cloud Experiment (MC3E). The profiling radars were deployed in Northern Oklahoma at the DOE Atmospheric Radiation Mission (ARM) Southern Great Plans (SGP) Central Facility from 22 April through 6 June 2011. NOAA deployed three instruments: a Parsivel disdrometer, a 2.8-GHz profiler, and a 449-MHz profiler. The parasivel provided surface estimates of the raindrop size distribution and is the reference used to absolutely calibrate the 2.8 GHz profiler. The 2.8-GHz profiler provided unattenuated reflectivity profiles of the precipitation. The 449-MHz profiler provided estimates of the vertical air motion during precipitation from near the surface to just below the freezing level. By using the combination of 2.8-GHz and 449-MHz profiler observations, vertical profiles of raindrop size distributions can be retrieved. The profilers are often reference by their frequency band: the 2.8-GHz profiler operates in the S-band and the 449-MHz profiler operates in the UHF band. The raw observations are available as well as calibrated spectra and moments. This document describes how the instruments were deployed, how the data was collected, and the format of the archived data.

54 ENVIRONMENTAL SCIENCES↗

Doppler Lidar Motion-Correction Wind Profiles (DLMCPROF-WIND) Value-Added Product Report

Wind speed and direction, together with pressure, temperature, and relative humidity, are the most fundamental atmospheric state parameters. Accurate measurement of these parameters is crucial for numerical weather prediction. Vertically resolved wind measurements in the atmospheric boundary layer are particularly important for modeling pollutant and aerosol transport. The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility currently operates several scanning coherent Doppler lidar (DL) systems that provide accurate height-resolved measurements of wind speed and direction. These instruments operate in the near infrared (IR;1.5 microns) and provide range-resolved measurements of radial velocity, attenuated aerosol backscatter, and signal-to-noise ratio (SNR). The systems are operated using a fixed scan schedule consisting of plan position indicator (PPI) or Doppler Beam-Swing (DBS) scans. PPI scans are performed by scanning the beam in azimuth while maintaining a fixed elevation angle, and DBS scans are similar but typically also include a vertical beam. Radial velocity data from these scans are processed to yield profiles of wind speed direction. For stationary ground-based deployments, the Doppler Lidar Horizontal Wind Profiles (DLPROF-WIND) Value-Added-Product (VAP) provides height- and time-resolved measurements of the winds (Newsom and Krishnamurthy 2022). For operation on a moving platform, modifications to the existing DLPROF-WIND VAP are required to compensate for the effects of the platform motion. This report describes a parallel VAP, DLMCPROF-WIND, that was developed for computing motion-compensated wind profiles from ARM Doppler lidar data acquired during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) campaign, when the lidar was deployed on the German icebreaker Polarstern.

54 ENVIRONMENTAL SCIENCES↗