Search NASA⌕ Search

SEARCH · Search NASA

Results for “multichannel analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multichannel analyzers at high rates of input

Multichannel analyzer, used with a gating system incorporating pole-zero compensation, pile-up rejection, and baseline-restoration, achieves good resolution at high rates of input. It improves resolution, reduces tailing and rate-contributed continuum, and eliminates spectral shift.

Rudnick, S. J.↗

Increased sensitivity of a vidicon optical multichannel analyzer with a detachable electrostatic image intensifier

A substantial gain in sensitivity is reported through the addition of a commercially available electrostatic image intensifier to a silicon-intensified target vidicon system. This comparatively low cost modification allows cooled or room temperature operation, CW or pulsed detection, and ease of removal or attachment. A 40-mm, first-generation technology image intensifier was used in a configuration in which the photocathode end was at negative high voltage and the phosphor end was at ground. Cooling the vidicon detector did not result in improved SNR; more generally, a 50-fold sensitivity increase was observed for the image intensifier/vidicon system.

Snow, J. B.↗

Faster optical-spectra recording and analysis

Optical spectra are recorded and rapidly analyzed by system that links multichannel analyzer and desk-top programable calculator. Cassette-memory storage is provided. System can be programed to automate background subtraction, axis expansion, and other data-analysis techniques and can store several hundred spectra for immediate or delayed analysis and comparisons.

Richmond, R. G.↗

Multichannel pulse height analyzer is inexpensive, features low power requirements

Consumption multichannel pulse height analyzer performs balloon and rocket investigations of solar neutrons with energies greater than 10 MeV. The lightweight unit can operate in a temperature range of minus 30 degrees to plus 70 degrees C and withstand storage temperatures from minus 50 degrees to plus 90 degrees C.

Ewald, C. J.↗

High-speed digital plotter

Modified typewriter mechanism with standard logic components provides digital plot of output of multichannel analyzer. Unit plots irregular curves at approximately 14 channels per second, and smooth curves at over 25 channels per second, and is not subject to analog error or drift.

Gray, J., Jr.↗

Thermospheric temperature measurement technique.

A method for measurement of temperature in the earth's lower thermosphere from a high-velocity probes is described. An undisturbed atmospheric sample is admitted to the instrument by means of a free molecular flow inlet system of skimmers which avoids surface collisions of the molecules prior to detection. Measurement of the time-of-flight distribution of an initially well-localized group of nitrogen metastable molecular states produced in an open, crossed electron-molecular beam source, yields information on the atmospheric temperature. It is shown that for high vehicle velocities, the time-of-flight distribution of the metastable flux is a sensitive indicator of atmospheric temperature. The temperature measurement precision should be greater than 94% at the 99% confidence level over the range of altitudes from 120-170 km. These precision and altitude range estimates are based on the statistical consideration of the counting rates achieved with a multichannel analyzer using realistic values for system parameters.

Hueser, J. E.↗

Device for recording the 20 Hz - 200 KHz sound frequency spectrum using teletransmission

The device described consists of two distinct parts: (1) The sound pickup system consisting of the wide-frequency band condenser microphone which contains in the same assembly the frequency-modulated oscillator and the output stage. Being transistorized and small, this system can be easily moved, so that sounds can be picked up even in places that are difficult to reach with larger devices. (2) The receiving and recording part is separate and can be at a great distance from the sound pickup system. This part contains a 72 MHz input stage, a frequency changer that gives an intermediate frequency of 30 MHz and a multichannel analyzer coupled to an oscilloscope and a recorder.

Baciu, I.↗

Nondestructive activation analysis of sample of lunar surface material returned by Luna 16 automatic station

The composition of a sample of lunar surface material returned by the Luna 16 automatic station from the Sea of Fertility was studied, using nondestructive activation analysis. The structure of the returned surface material is inhomogeneous; the surficial material is thin, quite homogeneous, and the granularity increases with depth. Based on grain size, the sample was separated into five zones. The activation analysis was conducted on a sample taken from the friable surficial layer, zone A. The content of Al, Mn, Na, Cr, Co, Fe, and Sc was determined by nondestructive activation analysis of the sample. In determining Cr, Co, Fe, and Sc, the sample was irradiated for 24 hours and cooled for 10 days. Gamma spectra of the samples were recorded with a semiconductor Ge(Li)-detector and a multichannel analyzer, and measurement data were processed with an electronic computer.

Chayko, M.↗

Measurements of H-beta, He D3, and Ca/+/ 8542-A line emission in quiescent prominences

Measurements of H-beta, He D3, and Ca(+) 8542-A line emission in 18 quiescent prominences are presented which were performed with a 25-cm coronagraph/coude spectrograph system and an optical multichannel analyzer utilizing a Si-vidicon detector assembly mounted at the single-pass spectrograph port. The data obtained show that the line profiles deviate in the wings from those calculated on the basis of an isothermal atmosphere and a Gaussian absorption coefficient. Both a non-Gaussian microturbulence component and a temperature gradient from prominence-core to coronal values can successfully account for this phenomenon. The line widths from a given line of sight of prominence material are reduced on the basis of a common core emitting region with a temperature of 7500 to 11,600 K and a microturbulent velocity of 4.5 to 7.1 km/s for the isothermal model (these values are 5% to 10% less for the two-temperature model). It is noted that long-period low-amplitude oscillations in the D3 line width and intensity were observed when a specific line of sight in a quiescent prominence was followed. These oscillations are found to remain coherent for as many as 3 or 4 cycles and to be associated with prominence structural activation.

Landman, D. A.↗

OAST Space Theme Workshop. Volume 2: Theme summary. 3: Search for extraterrestrial intelligence (no. 9). A: Theme statement. B. 26 April 1976 presentation. C. Summary. D. Newer initiatives (form 4). E. Initiative actions (form 5)

Preliminary (1977-1983), intermediate (1982-1988), and long term (1989+) phases of the search for extraterrestrial intelligence (SETI) program are examined as well as the benefits to be derived in radioastronomy and the problems to be surmounted in radio frequency interference. The priorities, intrinsic value, criteria, and strategy for the search are discussed for both terrestrial and lunar-based CYCLOPS and for a space SETI system located at lunar liberation point L4. New initiatives related to antenna independent technology, multichannel analyzers, and radio frequency interference shielding are listed. Projected SETI program costs are included.

Source record↗

Daylight spectra of individual lightning flashes in the 370-690 nm region

An optical multichannel analyzer slit spectrometer coupled to a minicomputer was used to record lightning spectra. This is the first successful application of a slit spectrometer to the study of individual lightning flashes and it was accomplished in the daytime. Over 300 spectra were obtained in 1978 and 1979 and are correlated with other experiments in the Thunderstorm Research International Program (TRIP). The spectra duplicate previously published nighttime data but reveal for the first time the relative intensity of H-alpha (656.3 nm) and H-beta (486.1 nm) emissions above their daytime absorption features. These are the characteristic Fraunhofer C and F lines in the solar spectrum. This result suggests that the observation of lightning from space may be accomplished by monitoring the hydrogen emissions from lightning which occur on earth, or on other planets with hydrogen in their atmospheres, such as Jupiter and Venus where lightning recently has been reported.

Orville, R. E.↗

Single-pulse broad-band rotational CARS thermometry of cold N2 gas

Coherent anti Stokes Raman scattering (CARS) from the pure rotational Raman lines of N2 was employed to measure the instantaneous (10 nsec) rotational temperature of the gas at room temperature and below. An entire rotational CARS spectrum was generated by a single laser pulse using a broad bandwidth dye laser and was recorded on an optical multichannel analyzer. A best fit temperature obtained for individual experimental spectra by comparison with calculated spectra. Good agreement between CARS temperatures and thermocouple temperatures was observed.

Chang, R. K.↗

Quiescent prominence spectrophotometry - Sodium D1,2, helium D3, and calcium /plus/ lambda 8498

The reported observations were carried out by means of a 25 cm coronagraph/coude spectrograph with a Si vidicon Optical Multichannel Analyzer (OMA) detector. The results of the investigation are presented in a number of tables, and the main conclusions concerning the studies are discussed. The relative behavior of prominence Na D line emission shows that the employed observing techniques yield reliable measures of prominence line strengths, not degraded to any substantial extent, in particular, by possible slit-filling effects. This conclusion is limited principally by the assumption that systematic vertical velocity fields in the prominences are not greater than 1.5 km/s. The Na D line profiles are well fitted by a one-component (i.e., homogeneous) line-forming region, thus reinforcing previous conclusions regarding the source of the enhanced wing emission.

Landman, D. A.↗

Partial discharge testing under direct voltage conditions

DC partial discharge (PD) (corona) testing is performed using a multichannel analyzer for pulse storing, and data is collected during increase of voltage and at quiescent voltage levels. Thus high voltage ceramic disk capacitors were evaluated by obtaining PD data interspersed during an accelerated life test. Increased PD activity was found early in samples that later failed catastrophically. By this technique, trends of insulation behavior are revealed sensitively and nondestructively in high voltage dc components.

Bever, R. S.↗

Field investigation of techniques for remote laser sensing of oceanographic parameters

A laser fluorosensor, previously studied in the laboratory, was deployed at a pier in lower Chesapeake Bay for field testing. A Q-switched Nd:YAG laser doubled to 532 nm in conjunction with a gated optical multichannel analyzer (OMA) allow spectra with high signal-to-noise ratios to be recorded in full daylight at a distance of 20 m. As a test of the system a study was conducted of the spatial and temporal variations of the phytopigments phycoerythrin and chlorophyll. The phycoerythrin feature was resolved into two components, one attributable to cyanophytes and the other to cryptophytes. A comparison was also made with spectra obtained by the NASA airborne oceanographic lidar (AOL).

Houghton, W. M.↗

Simultaneous observation of rotational coherent Stokes Raman scattering and coherent anti-Stokes Raman scattering in air and nitrogen

Rotational coherent Stokes Raman scattering (CSRS) and coherent anti-Stokes Raman scattering (CARS) in air and in nitrogen were observed simultaneously by using broadband generation and detection. In the broadband technique used, the entire CARS and CSRS spectrum was generated in a single laser pulse; the CSRS and CARS signals were dispersed by a spectrograph and detected simultaneously by an optical multichannel analyzer. A three-dimensional phase-matching geometry was used to achieve spatial resolution of the CSRS and CARS beams from the input beams. Under resonant conditions, similar experiments may provide a means of investigating the possible interaction between the CSRS and CARS processes in driving the rotational levels.

Snow, J. B.↗