Search NASA⌕ Search

SEARCH · Search NASA

Results for “multipactor coating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

High Average Power RF Window with Improved Multipactor Coating

Multipactor emission can be a serious issue for vacuum electron devices operating at megawatt power levels. It can lead to catastrophic failure from surface arcs or excessive heating of ceramic windows. Titanium nitride is effective at suppressing multipactor emission; however, sputter coating is not strongly bonded to surfaces and issue related to lifetime have arisen. It’s difficult to ensure a uniform coating over large surfaces. This research investigated atomic layer deposition (ALD) as an improved alternative to sputtered coatings. Test windows were fabricated and coated with TiN using ALD, then tested for RF loss and secondary emission. All ALD samples showed RF loss less than 0.01dB with secondary emission yield equal to or better than reported measurements with sputter coated windows. The program also designed a preliminary ALD system capable of coating windows up to 24 inches in diameter.

43 PARTICLE ACCELERATORS↗

Update on the Development of Externally Powered Dielectric-Loaded Accelerating Structures

We report on recent progress in a program to develop an RF-driven Dielectric-Loaded Accelerating (DLA) structure, capable of supporting high gradient acceleration. Previous high power tests revealed that the earlier DLA structures suffered from multipactor and arcing at the dielectric joint. A few new DLA structures have been designed to alleviate this limitation including the coaxial coupler based DLA structure and the clamped DLA structure. These structures were recently fabricated and high power tested at the NRL X-band Magnicon facility. Results show the multipactor can be reduced by the TiN coating on the dielectric surface. Gradient of 15 MV/m has also been tested without dielectric breakdown in the test of the clamped DLA structure. Detailed results are reported, and future plans discussed.

43 PARTICLE ACCELERATORS↗

Update on the development of externally powered dielectric-loaded accelerating structures.

We report on recent progress in a program to develop an RF-driven Dielectric-Loaded Accelerating (DLA) structure, capable of supporting high gradient acceleration. Previous high power tests revealed that the earlier DLA structures suffered from multipactor and arcing at the dielectric joint. A few new DLA structures have been designed to alleviate this limitation including the coaxial coupler based DLA structure and the clamped DLA structure. These structures were recently fabricated and high power tested at the NRL X-band Magnicon facility. Results show the multipactor can be reduced by the TiN coating on the dielectric surface. Gradient of 15 MV/m has also been tested without dielectric breakdown in the test of the clamped DLA structure. Detailed results are reported, and future plans discussed.

36 MATERIALS SCIENCE↗

Progress toward externally powered x-band dielectric-loaded accelerating structures.

We summarize recent progress in a program to develop externally powered dielectric-loaded accelerating (DLA) structures that can sustain high accelerating gradients. High-power RF tests of earlier structures showed strong multipactor loading. In addition, arcing at dielectric joints between the uniform DLA structure and matching sections at either end limited the achievable gradient. In this paper, we study the onset of multipactor in a DLA structure. We also study the effect of thin-film TiN coatings applied by atomic layer deposition and the effect of a reduction in the inner diameter of the structure. Test results of these structures show significant decreases in multipactor loading. We also test new structure designs that eliminate separate dielectric matching sections and, thus, the requirement for dielectric joints, including a DLA structure using a coaxial coupler and a clamped DLA structure. The clamped structure demonstrated a significantly improved gradient without breakdown.

36 MATERIALS SCIENCE↗

Multipactor theory for multicarrier signals

This work presents a new theory of multipactor under multicarrier signals for parallel-plate geometries, assuming a homogeneous electric field and one-dimensional electron motion. It is the generalization of the nonstationary multipactor theory for single-carrier signals [S. Anza et al.,Phys. Plasmas 17, 062110 (2010)]. It is valid for multicarrier signals with an arbitrary number of carriers with different amplitude, arbitrary frequency, and phase conditions and for any material coating. This new theory is able to model the real dynamics of the electrons during the multipactor discharge for both single and double surface interactions. Among other parameters of the discharge, it calculates the evolution in time of the charge growth, electron absorption, and creation rates as well as the instantaneous secondary emission yield and order. An extensive set of numerical tests with particle-in-cell software has been carried out in order to validate the theory under many different conditions. This theoretical development constitutes the first multipactor theory which completely characterizes the multipactor discharge for arbitrary multicarrier signals, setting the first step for further investigations in the field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of internal dark current in a 17 GHz, high gradient accelerator structure

We report the measurement of the internal dark current in a 17 GHz, high gradient accelerator cavity and its comparison with theory. The cavities were fabricated from copper and had a sidewall that was either uncoated or coated with diamondlike carbon or TiN. The dark current was monitored by a downstream detector and by detectors behind two small slits made in the cavity sidewall. With an increasing gradient, the downstream current increased monotonically, as expected for field emission. The variation of the internal, side dark current was not monotonic but showed the onset of peaks at gradients near 45 and 65 MV / m . These were identified as the N = 2 and N = 1 single point multipactor resonances. The total internal dark current was estimated at ~ 15 – 30 A . The magnitude of the internal dark current and its dependence on the gradient were in good agreement with simulations using the cst code as well as an in-house code. Processing to a higher gradient, ~ 90 MV / m , eliminated the N = 2 mode, but the N = 1 mode persisted. The coated sidewall cavities showed the same multipactor resonances as the uncoated structure. However, at the highest gradient achieved in testing, the coated structures showed a modest reduction in the internal dark current.

43 PARTICLE ACCELERATORS↗

Measurement of internal dark current in a 17 GHz, high gradient accelerator structure

We report the measurement of the internal dark current in a 17 GHz, high gradient accelerator cavity and its comparison with theory. The cavities were fabricated from copper and had a sidewall that was either uncoated or coated with diamond-like carbon or TiN. The dark current was monitored by a downstream detector and by detectors behind two small slits made in the cavity side wall. With an increasing gradient, the downstream current increased monotonically, as expected for field emission. The variation of the internal, side dark current was not monotonic but showed the onset of peaks at gradients near 45 and 65 MV/m. These were identified as the N = 2 and N = 1 single point multipactor resonances. The total internal dark current was estimated at ∼15–30 A. The magnitude of the internal dark current and its dependence on the gradient were in good agreement with simulations using the CST code as well as an in-house code. Processing to a higher gradient, ∼90 MV/m, eliminated the N = 2 mode, but the N = 1 mode persisted. The coated sidewall cavities showed the same multipactor resonances as the uncoated structure. However, at the highest gradient achieved in testing, the coated structures showed a modest reduction in the internal dark current.

43 PARTICLE ACCELERATORS↗

High power RF window deposition apparatus, method, and device

A process for forming a coating for an RF window which has improved secondary electron emission and reduced multipactor for high power RF waveguides is formed from a substrate with low loss tangent and desirable mechanical characteristics. The substrate has an RPAO deposition layer applied which oxygenates the surface of the substrate to remove carbon impurities, thereafter has an RPAN deposition layer applied to nitrogen activate the surface of the substrate, after which a TiN deposition layer is applied using Titanium tert-butoxide. The TiN deposition layer is capped with a final RPAN deposition layer of nitridation to reduce the bound oxygen in the TiN deposition layer. The resulting RF window has greatly improved titanium layer adhesion, reduced multipactor, and is able to withstand greater RF power levels than provided by the prior art.

36 MATERIALS SCIENCE↗

Testing of PIP-II pre-production 650 MHz couplers in warm test stand and in cryomodule

650 MHz fundamental power couplers were developed for PIP-II project to deliver RF power for low-beta and high-beta elliptical cavities. Few prototypes were built and tested and after some modification we built 8 pre-production couplers (with few spares for vacuum side) for HB650 cryomodule. All couplers were successfully tested in pulse mode (up to 100kW) and in CW mode (up to 50kW) in test stand at full reflection at 8 phases. In baseline configuration with DC bias we do not see any multipactoring activity after short processing. We also tested power processing without bias for uncoated and TiN coated ceramic window. Results of these studies presented in this paper. One of the coupler was assembled on LB650 cavity and tested at cryogenic environment in STC cryostat at ~20kW power with full reflection at different reflection phase. We also demonstrated good result from power processing without bias for warm and cold cavity. Six couplers were assembled on HB650 cavities in pre-production cryomodule. Test results from cryomodule qualification is discussing in this paper.

43 PARTICLE ACCELERATORS↗

Development and Testing of Advanced Accelerator Structures and Technologies at 11.424 GHz (Final Report)

The areas of activity are grouped by Task. Task 1 involved a study of the key physics issues associated with the use of high gradient dielectric-loaded accelerating (DLA) structures in rf linear accelerators, and was carried out in collaboration with Argonne National Laboratory (ANL) and Euclid Techlabs LLC; Task 2 involved a study of high-gain active microwave pulse compressors, and was carried out in collaboration with Omega-P, Inc. and the Institute of Applied Physics of the Russian Academy of Sciences. The experiments were carried out in the X-band Magnicon Laboratory at the Naval Research Laboratory (NRL). The studies under Task 1 were focused on multipactor and breakdown in externally driven DLA structures at the 200-ns timescale. Suppression of multipactor and breakdown are essential to the practical application of dielectric structures in rf linear accelerators. During the first year of this program, we carried out a study of a doubly tapered clamped quartz traveling-wave (TW) structure that operated at up to 15 MV/m without breakdown by eliminating dielectric joints, thus avoiding the joint breakdown that had characterized many earlier experiments. However, strong multipactor loading was observed in the structure. In the second year, we carried out a successful test of a TW DLA structure with a sputtered copper exterior coating that eliminated the need for a clamped metal enclosure to form the outer metallic boundary, thus simplifying the fabrication of the structure. In the second year, we also carried out the first test of a dielectric-loaded standing-wave (SW) accelerating structure. Multipactor loading limited the achievable accelerating gradient in the structure to 9 MV/m, but the SW structure proved to be a useful configuration for studying multipactor physics. To continue this study, a new standing-wave structure is in preparation that will permit direct measurements of the energy stored in the structure for new studies of multipactor physics. Finally, in the third year of the program, we focused on the suppression of multipactor loading using an applied axial magnetic field, as proposed by Chang et al. [C. Chang et al., J. Appl. Phys. 110, 063304 (2011).]. Chang used an analytic model and PIC simulations to show that an axial magnetic field can reduce the period of the secondary electron trajectories on the dielectric surface, and thus spoil the multipactor resonance condition. The optimum effect occurs when the ratio of the gyrofrequency to the rf frequency is in the range of ~ 0.7 to 1. For an X-band structure, this is equivalent to a solenoidal field of 2.8–4 kG. This approach to multipactor suppression is attractive because it maintains the advantages of a DLA structure and is independent of other accelerator parameters.

43 PARTICLE ACCELERATORS↗

Testing and Processing of Pre-production 325 MHz Single Spoke Resonator Power Couplers for PIP-II Project

Fundamental 325 MHz power couplers are designed, built and tested for SSR cavities in PIP-II project. Couplers should work in CW mode at power level 7.5kW w/o beam and ~15 kW with the 2 mA beam. At pre-production stage we built and tested 6 couplers, produced by CPI (FNAL) and PMB (IJCLab) and 4 more couplers will be tested soon. Two of tested couplers had TiN coated ceramic window. In warm test stand two couplers were mounted on the coupling chamber and tested in SW regime at full reflection with phase controlled by position of short and reflection insert. Couplers were tested at pulse mode (up to 25kW) and cw mode (12kW) with HV bias or without bias. Test results demonstrated that 3.5 kV DC bias completely suppresses multipactor in coupler. Vacuum activity in coupler was controlled by e-pickups and build-in vacuum gauges, located near the vacuum side of window. Power processing without DC bias was done for several couplers with and without TiN coating on ceramic window. Test results are presented and discussing in paper.

43 PARTICLE ACCELERATORS↗

TESTING AND PROCESSING OF PRE-PRODUCTION 325 MHZ SINGLE SPOKE RESONATOR POWER COUPLERS FOR PIP-II PROJECT

Fundamental 325 MHz power couplers are designed, built and tested for SSR cavities in PIP-II project [1]. Couplers should work in CW mode at power level 7.5kW w/o beam and ~15 kW with the 2 mA beam. At pre-production stage we built and tested 6 couplers, produced by CPI (FNAL) and PMB (IJCLab) and 4 more couplers will be tested soon. Two of tested couplers had TiN coated ceramic window. In warm test stand two couplers were mounted on the coupling chamber and tested in SW regime at full reflection with phase controlled by position of short and reflection insert. Couplers were tested at pulse mode (up to 25kW) and cw mode (12kW) with HV bias or without bias. Test results demonstrated that 3.5 kV DC bias completely suppresses multipactor in coupler. Vacuum activity in coupler was controlled by e-pickups and build-in vacuum gauges, located near the vacuum side of window. Power processing without DC bias was done for several couplers with and without TiN coating on ceramic window. Test results are presented and discussing in paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗