Data conditioning and display for Apollo prelaunch checkout. Multi-parameter monitoring display
Multiparameter monitoring visual displays for Apollo prelaunch checkout
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Multiparameter monitoring visual displays for Apollo prelaunch checkout
The development of advanced distributed optical fiber sensing systems that are capable of performing accurate and spatially resolved multiparameter measurements is of great interest to a wide range of scientific and industrial applications. Here, in this paper, we propose and experimentally demonstrate a wavelength diversity based advanced distributed optical fiber sensor system to accomplish multiparameter sensing while greatly enhancing measurement accuracy. A suite of deep neural network (DNN) algorithms are developed and verified for data denoising, rapid Brillouin frequency shift estimation, and vibration data event classification. As a proof-of-concept, we demonstrate the effectiveness of the proposed advanced wavelength diversity distributed fiber sensor system assisted by DNN for simultaneous, independent measurements of static strain, temperature, and acoustic vibrations over a 25 km long sensing fiber at 3 m spatial resolution. These results suggest the potential for an intelligent multiparameter monitoring system with enhanced performance in advanced structural health monitoring applications.
A novel, unobtrusive and wearable, multiparameter ambulatory physiologic monitoring system for space and terrestrial applications, termed LifeGuard, is presented. The core element is a wearable monitor, the crew physiologic observation device (CPOD), that provides the capability to continuously record two standard electrocardiogram leads, respiration rate via impedance plethysmography, heart rate, hemoglobin oxygen saturation, ambient or body temperature, three axes of acceleration, and blood pressure. These parameters can be digitally recorded with high fidelity over a 9-h period with precise time stamps and user-defined event markers. Data can be continuously streamed to a base station using a built-in Bluetooth RF link or stored in 32 MB of on-board flash memory and downloaded to a personal computer using a serial port. The device is powered by two AAA batteries. The design, laboratory, and field testing of the wearable monitors are described.
The demand for real-time sensors in harsh environments at elevated temperature is significant and increasing. In this manuscript, the chemical and temperature sensing using the optical response through the practical fiber platform is demonstrated, and principle component analysis is coupled with targeted experimental film characterization to understand the fundamental sensing layer properties, which dominate measured gas sensing responses in complex gas mixtures. More specifically, tin-doped indium oxide-decorated sensors fabricated with the sol–gel method show stable and stepwise transmission responses varying over a wide range of H2 concentration (5–100%) at 250–350 °C as well as responses to CH4 and CO to a lesser extent. Measured responses are attributed to modifications to the surface plasmon resonance absorption in the near-infrared range and are dominated by the highest concentrations of the most-reducing analyte based upon systematic mixed gas stream experiments. Principal component analysis is utilized for this type of sensor to improve the quantitative and qualitative understanding of responses, clearly identifying that the dominant principle component (PC #1) accounts for ~78% of total data variance. Correlations between PC #1 and the experimentally derived free carrier concentration confirm that this material property plays the strongest role on the ITO gas sensing mechanism, while correlations between the free carrier mobility and the second most important principle component (PC #2) suggest that this quantity may play a significant but secondary role. As such, the results presented here clarify the relationship between generalized principle components and fundamental sensing materials properties thereby suggesting the pathway toward improved multicomponent gas speciation through sensor layer engineering. Furthermore, the work presented represents a significant step toward the ultimate objective of optical waveguide sensors integrated with multivariate data analytics for multiparameter monitoring with a single sensor element.
Background: The cacophony of alerts and alarms in a hospital produced by medical devices results in alarm fatigue. The pulse oximeter is one of the most common sources of alarms. One of the ways to reduce alarm rates is to adjust alarm settings at the bedside. This study is aimed to retrospectively examine individual pulse oximeter alarm settings on alarm rates and inter- and intra- patient variability. Methods: Nine hundred sixty-two previously collected intensive care unit (ICU) patient records were obtained from the Multiparameter Intelligent Monitoring in Intensive Care II Database (Beth Israel Deaconess Medical Center, Boston, MA). Inclusion criteria included patient records that contained SpO 2 trend data sampled at 1 Hz for at least 1 h and a matching clinical record. SpO 2 alarm rates were simulated by applying a range of thresholds (84, 86, 88, and 90 %) and delay times (10 to 60 s) to the SpO 2 data. Patient records with at least 12 h of SpO 2 data were examined for the variability in alarm rate over time. Results: Decreasing SpO 2 thresholds and increasing delay times resulted in decreased alarm rates. A limited number of patient records accounted for most alarms, and this number increased as alarm settings loosened (the top 10 % of patient records were responsible for 57.4 % of all alarms at an SpO 2 threshold of 90 % and 15 s delay and 81.6 % at an SpO 2 threshold of 84 % and 45 s delay). Alarm rates were not consistent over time for individual patients with periods of high and low alarms for all alarm settings. Conclusion: Pulse oximeter SpO 2 alarm rates are variable between patients and over time, and the alarm rate and the extent of inter- and intra-patient variability can be affected by the alarm settings. Personalized alarm settings for a patient’s current status may help to reduce alarm fatigue for nurses.
The goal of this project was to design, fabricate and test an optical fiber cable which supports multiple sensing modalities for measurements in the harsh environment of enhanced geothermal systems. To accomplish this task, optical fiber was tested at both high temperatures and strains for mechanical integrity, and in the presence of hydrogen for resistance to darkening. Both single mode (SM) and multimode (MM) commercially available optical fiber were identified and selected for the cable based on the results of these tests. The cable was designed and fabricated using a tube-within-tube construction containing two MM fibers and one SM fiber, and without supporting gel that is not suitable for high temperature environments. Commercial fiber optic sensing instruments using Raman DTS (distributed temperature sensing), Brillouin DTSS (distributed temperature and strain sensing), and Raleigh COTDR (coherent optical time domain reflectometry) were selected for field testing.
Monitoring for neuroprotection, like surgery, has placed on emphasis on minimal or non-invasiveness. Monitoring of parameters that truly reflect the degree of injury to the nervous system is another goal. Thus, two themes for the coming decade in neuromonitoring will be: (1) less-invasive monitoring; and (2) parameters that more closely reflect the etiological factors in ischemic or other neuroinjury. In this paper, we review neuromonitoring techniques and devices that can be used readily in the operating room or intensive care unit setting. Those that require transport of the patient to a special facility (e.g., for computed tomography or magnetic resonance imaging/spectroscopy) and those that have been in standard practice for neuromonitoring (e.g., electrophysiological monitoring--EEG, evoked potentials) are not considered. The two techniques considered in detail are (1) continuous multiparameter local brain tissue monitoring with microprobes, and (2) non-invasive continuous local brain tissue oxygenation monitoring by near infrared spectroscopy. Both techniques have been cleared by the Food and Drug Administration (FDA) for clinical use. The rationale for their use, the nature of the devices, and clinical results to date are reviewed. It is expected that both techniques will gain wide acceptance during the coming decade; further advances in neuromonitoring that can be expected further into the twenty-first century are also discussed.
Linea Research Corporation has developed a neurodiagnostic tool that detects behavioral stress markers for astronauts on long-duration space missions. Lightweight and compact, the device is unobtrusive and requires minimal time and effort for the crew to use. The system provides a real-time functional imaging of cortical activity during normal activities. In Phase I of the project, Linea Research successfully monitored cortical activity using multiparameter sensor modules. Using electroencephalography (EEG) and functional near-infrared spectroscopy signals, the company obtained photoplethysmography and electrooculography signals to compute the heart rate and frequency of eye movement. The company also demonstrated the functionality of an algorithm that automatically classifies the varying degrees of cognitive loading based on physiological parameters. In Phase II, Linea Research developed the flight-capable neurodiagnostic device. Worn unobtrusively on the head, the device detects and classifies neurophysiological markers associated with decrements in behavior state and cognition. An automated algorithm identifies key decrements and provides meaningful and actionable feedback to the crew and ground-based medical staff.
Low-cost, multiparameter sensing and measurement devices enable cost-effective monitoring of the functional, operational reliability, efficiency, and resiliency of the electric grid. The National Renewable Research Laboratory (NREL) Solar Radiation Research Laboratory (SRRL), in collaboration with Arable Labs, Inc., deployed Arable Lab's Mark multiparameter sensor system. The device measures the downwelling and upwelling shortwave solar resource and longwave radiation, humidity, air temperature, and ground temperature. The system is also equipped with six downward-and upward-facing narrowband spectrometer channels that measure spectral radiation and surface spectral reflectance. This study describes the shortwave calibration, characterization, and validation of measurement accuracy of this instrument by comparison with existing instruments that are part of NREL-SRRL's Baseline Measurement System.
Research and proposed experiments for improving the capabilities of spaceborne imaging radars are discussed. The development of multiparameter research sensors, long-term and global monitoring sensors, planetary mapping sensors, and topographic three-dimensional imagers is examined. The properties and functions of these proposed sensors are described; examples of these various types of sensors are provided.
Continuous seismic monitoring for quantifying CO 2 plume migration and detection of any potential leakages in the subsurface is essential for the security of long-term anthropogenic carbon dioxide geologic storage. Traditional time-lapse full-waveform inversion (TLFWI) methods aim to map the CO 2 distribution by estimating seismic velocity changes, but recent studies find that CO 2 -induced attenuation is an important complement to seismic velocity for tracking the CO 2 plumes and even quantifying the CO 2 saturation. We have developed a novel data-assimilated TLFWI method to construct high-resolution time-lapse velocity and attenuation changes from dense time-lapse monitoring data. This method consists of two theoretical developments: visco-acoustic full-waveform inversion (QFWI) and multiparameter hierarchical matrix-powered extended Kalman filter (mHiEKF). The method is capable of (1) posing temporal constraints to retrieve time-lapse information from dense monitoring data by using mHiEKF, (2) accurately recovering high-spatial-resolution velocity and attenuation perturbations using first-order equation system-based QFWI, and (3) providing the model uncertainty by estimating their model standard deviation. With numerical examples, we first find the effectiveness of the new QFWI on estimating accurate velocity and attenuation models simultaneously. Then, a CO 2 leakage case and a realistic Frio-II CO 2 monitoring case are presented to find the advantages and applicability of our data-assimilated QFWI method for estimating time-lapse changes using dense time-lapse monitoring surveys. Here, by assimilating time-lapse seismic monitoring data over time, our data-assimilated QFWI method can improve the resolution of velocity and attenuation changes and decrease their model uncertainties.
Monitoring of energy infrastructure through robust yet economical sensing platforms is becoming an area of increased importance, with ubiquitous applications including the electrical grid, natural gas and oil transportation pipelines, H2 infrastructure (storage and transportation), carbon storage, power generation, and subsurface environments. Plasmonic and functional nanomaterial enabled fiber optic sensors show excellent promise for a wide range of sensing applications due to their versatility to be engineered for specific analytes of interest while retaining inherent advantages of the optical fiber sensor platform. Through the design of novel sensing layers, the optical transduction mechanism and wavelength dependence can also be tailored for ease of integration with low-cost interrogation systems enabling an inexpensive yet highly functional optical fiber sensing platform. In addition, recent advances in artificial intelligence and machine learning theoretical methods have been leveraged to simultaneously extract multiple parameters through multi-wavelength interrogation such that unique wavelengths can also serve as unique sensing elements, analogous to electronic nose sensor technologies. The concept of an optical fiber based “photonic nose” via multiple interrogation wavelengths and/or sensor nodes offers a compelling platform technology to realize multiparameter speciation of chemical analytes within complex gas mixtures. In this Perspective, we further generalize the notion of multiparameter sensing through the novel “photonic nervous system” concept based upon low-cost, functionalized optical fiber sensor probes monitoring a variety of distinct analyte classes (physical, chemical, electromagnetic, etc.) simultaneously to provide broad situational awareness via integrated sensors.
Understanding the role of circulating peptide hormones in the pathogenesis of space-flight induced disorders would be greatly facilitated by a method which monitors chronic levels of hormones and their effects upon in vivo cell physiology. Single and simultaneous multiparameter flow cytometry analysis was employed to identify subpopulations of mononuclear cells bearing receptors for ACTH, Endorphin, and Somatomedin-C using monoclonal antibodies and monospecific antisera with indirect immunofluorescence. Blood samples were obtained from normal donors and subjects participating in decompression chamber studies (acute stress), medical student academic examination (chronic stress), and a drug study (Dexamethasone). Preliminary results indicate most ACTH and Endorphin receptor positive cells are monocytes and B-cells, exhibit little diurnal variation but the relative percentages of receptor positive cells are influenced by exposure to various stressors and ACTH inhibition. This study demonstrates the capability of flow cytometry analysis to study cell surface hormone receptor regulation which should allow insight into neuroendocrine modulation of the immune and other cellular systems during exposure to stress or microgravity.
This paper describes the development and deployment of cyberaware sensors to monitor the electrical grid and aid with disaster relief. These cyberaware sensors, outstation agents, provide information of multiple parameters simultaneously acting like a black box. The sensors embedded in the outstation agents and the communication architectures are described. These outstation agents are deployed around electrical substations in stationary and mobile platforms. The data collected from the outstation agents is sent to the utility control center providing information of the current status of the electrical grid. In the event of a disaster, the outstation agents make available information on the state of the grid, failures, and resources available to create an effective restoration pathway.
The imaging radar experiments on SEASAT and on the space shuttle (SIR-A and SIR-B) have led to a wide interest in the use of spaceborne imaging radars in Earth and planetary sciences. The radar sensors provide unique and complimentary information to what is acquired with visible and infrared imagers. This includes subsurface imaging in arid regions, all weather observation of ocean surface dynamic phenomena, structural mapping, soil moisture mapping, stereo imaging and resulting topographic mapping. However, experiments up to now have exploited only a very limited range of the generic capability of radar sensors. With planned sensor developments in the late 80's and early 90's, a quantum jump will be made in our ability to fully exploit the potential of these sensors. These developments include: multiparameter research sensors such as SIR-C and X-SAR, long-term and global monitoring sensors such as ERS-1, JERS-1, EOS, Radarsat, GLORI and the spaceborne sounder, planetary mapping sensors such as the Magellan and Cassini/Titan mappers, topographic three-dimensional imagers such as the scanning radar altimeter and three-dimensional rain mapping. These sensors and their associated research are briefly described.
A brief history of the U.S. geosynchronous weather satellite program is presented. The introduction of multiparameter observation systems on the Geostationary Synchronous Environmental Satellite (GOES) is discussed, with emphasis given to the visible spin-scan radiometer (VISSR); Data Collection System (DCS); and the Space Environment Monitor (SEM). A synopsis of current measurement capabilities of the GOES satellites is given with respect to temperature and mositure parameters. Several examples of GOES satellite imagery are provided.
Hybrid or all-electric aircraft are being developed as the next generation of aircraft to both allow new forms of aviation and decrease environmental impact. Since these types of aircraft are based on high-capacity battery technology, safe operation of these batteries becomes increasingly important. In particular, the potential for battery failure due to uncontrolled chemical reactions resulting in thermal runaway, catastrophic failure, and battery fires must be addressed in order for such battery technology to have the level of safety needed for standard aviation implementation. Efforts to ensure battery safety often involve engineering solutions that seek to contain rather than prevent such events by early detection. Such approaches increase the system weight and decrease the power per unit mass provided by the battery system. Existing methods for measuring battery parameters to determine the battery state-of-health are limited. These methods include electrical measurements of the cell current and/or voltage output as well as temperature measurements taken externally on the cell surface. Such external temperature measurements are limited in their ability to provide early warning of impending battery failure. In response, an effort to develop sensors operating internal to battery for health monitoring has been ongoing in the NASA Sensor-based Prognostics to Avoid Runaway Reactions & Catastrophic Ignition (SPARRCI) project. The basic approach associated with this sensor work is the deposition of thin film sensors on the battery separator located between the anode and cathode of the battery. These thin film sensors are then monitored to determine changes in battery parameters and health. Microfabrication techniques are employed to minimize the overall impact of the sensors on battery operation through the implementation of sensors with minimal size, weight, and power consumption. The thickness of the films, which are fabricated through physical vapor deposition (sputtering), are on the order of thousands of angstroms and can have minimal surface area. Thin film sensors for system health management have been implemented for a many decades on complex components for aerospace applications. However, the application of thin films of this type on a battery separator for internal battery monitoring applications has not previously been demonstrated to our knowledge. This paper describes the development of sensors for the internal battery monitoring through the use of thin film sensor technology. Thin metal films were successfully deposited on a battery separator polymer material with good adherence and electrical continuity. Multiple types of sensors have been deposited, as well as lead connections from the sensor to the edge of the separator material. The ability of these thin film sensors immersed in electrolyte to perform multiple types of battery parameter measurements has been demonstrated. For example, a multiparameter sensor system measured multiple properties simultaneously inside of a pouch cell over a wide temperature range. Further, real time measurement of interior temperature changes in a battery pouch cell with an integrated interior temperature sensor was demonstrated. These changes include detecting a fault in the battery (shorting) in situ with rapid response time (less than a minute) corresponding to a more limited response by a temperature sensor mounted externally. Other aspects of monitoring battery health were also explored, such as real-time measurement of simulated dendrite growth/metal deposition by sensor on separator material demonstrated. Future efforts will include improvements in the durability of the sensor structure to allow introduction of the approach into standard battery fabrication techniques. Overall, this work is a step forward in providing a method to prevent catastrophic battery failures and provide a foundation for safer, lighter, and higher energy batteries for the electric aircraft industry.
The Integrated Status and Effectiveness Monitoring Project (ISEMP) program monitors the status and trend of water quality elements that may affect restoration project effectiveness in the Entiat subbasin. As part of this effort, the PNW Research Station (PNW) measures, analyzes and interprets temporal trends in natural stream water pH, dissolved oxygen, specific conductance and temperature. The Entiat River is currently on the Clean Water Act 303(d) list for pH exceedence, and there is insufficient information to determine the spatial and temporal extent or potential causes of this exceedence. In the late spring 2007, PNW deployed data-logging, multiparameter probes at four locations in the Entiat subbasin to measure water quality parameters, focusing on pH. Data collection was seasonally interrupted by river ice in early December. Daily average pH did not exceed the water quality standard of 8.5 at any of the measurements sites. However, instantaneous values did exceed this standard near the mouth of the Entiat River during late summer-fall period. This suggested that in the lowest portion of the river peaks in pH may be occurring because of photosynthesis caused by high rates of periphyton productivity in response to increased sunlight, temperature, and possible nutrient enrichment. Conversely, dissolved oxygen reached annual low levels during this same late summer-fall period, in part because of increased water temperatures and increased biochemical oxygen demand.