Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiparameter monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Achieving precise multiparameter measurements with distributed optical fiber sensor using wavelength diversity and deep neural networks

The development of advanced distributed optical fiber sensing systems that are capable of performing accurate and spatially resolved multiparameter measurements is of great interest to a wide range of scientific and industrial applications. Here, in this paper, we propose and experimentally demonstrate a wavelength diversity based advanced distributed optical fiber sensor system to accomplish multiparameter sensing while greatly enhancing measurement accuracy. A suite of deep neural network (DNN) algorithms are developed and verified for data denoising, rapid Brillouin frequency shift estimation, and vibration data event classification. As a proof-of-concept, we demonstrate the effectiveness of the proposed advanced wavelength diversity distributed fiber sensor system assisted by DNN for simultaneous, independent measurements of static strain, temperature, and acoustic vibrations over a 25 km long sensing fiber at 3 m spatial resolution. These results suggest the potential for an intelligent multiparameter monitoring system with enhanced performance in advanced structural health monitoring applications.

47 OTHER INSTRUMENTATION↗

Plasmonic Conducting Metal Oxide-Based Optical Fiber Sensors for Chemical and Intermediate Temperature-Sensing Applications

The demand for real-time sensors in harsh environments at elevated temperature is significant and increasing. In this manuscript, the chemical and temperature sensing using the optical response through the practical fiber platform is demonstrated, and principle component analysis is coupled with targeted experimental film characterization to understand the fundamental sensing layer properties, which dominate measured gas sensing responses in complex gas mixtures. More specifically, tin-doped indium oxide-decorated sensors fabricated with the sol–gel method show stable and stepwise transmission responses varying over a wide range of H2 concentration (5–100%) at 250–350 °C as well as responses to CH4 and CO to a lesser extent. Measured responses are attributed to modifications to the surface plasmon resonance absorption in the near-infrared range and are dominated by the highest concentrations of the most-reducing analyte based upon systematic mixed gas stream experiments. Principal component analysis is utilized for this type of sensor to improve the quantitative and qualitative understanding of responses, clearly identifying that the dominant principle component (PC #1) accounts for ~78% of total data variance. Correlations between PC #1 and the experimentally derived free carrier concentration confirm that this material property plays the strongest role on the ITO gas sensing mechanism, while correlations between the free carrier mobility and the second most important principle component (PC #2) suggest that this quantity may play a significant but secondary role. As such, the results presented here clarify the relationship between generalized principle components and fundamental sensing materials properties thereby suggesting the pathway toward improved multicomponent gas speciation through sensor layer engineering. Furthermore, the work presented represents a significant step toward the ultimate objective of optical waveguide sensors integrated with multivariate data analytics for multiparameter monitoring with a single sensor element.

47 OTHER INSTRUMENTATION↗

Retrospective analysis of pulse oximeter alarm settings in an intensive care unit patient population

Background: The cacophony of alerts and alarms in a hospital produced by medical devices results in alarm fatigue. The pulse oximeter is one of the most common sources of alarms. One of the ways to reduce alarm rates is to adjust alarm settings at the bedside. This study is aimed to retrospectively examine individual pulse oximeter alarm settings on alarm rates and inter- and intra- patient variability. Methods: Nine hundred sixty-two previously collected intensive care unit (ICU) patient records were obtained from the Multiparameter Intelligent Monitoring in Intensive Care II Database (Beth Israel Deaconess Medical Center, Boston, MA). Inclusion criteria included patient records that contained SpO 2 trend data sampled at 1 Hz for at least 1 h and a matching clinical record. SpO 2 alarm rates were simulated by applying a range of thresholds (84, 86, 88, and 90 %) and delay times (10 to 60 s) to the SpO 2 data. Patient records with at least 12 h of SpO 2 data were examined for the variability in alarm rate over time. Results: Decreasing SpO 2 thresholds and increasing delay times resulted in decreased alarm rates. A limited number of patient records accounted for most alarms, and this number increased as alarm settings loosened (the top 10 % of patient records were responsible for 57.4 % of all alarms at an SpO 2 threshold of 90 % and 15 s delay and 81.6 % at an SpO 2 threshold of 84 % and 45 s delay). Alarm rates were not consistent over time for individual patients with periods of high and low alarms for all alarm settings. Conclusion: Pulse oximeter SpO 2 alarm rates are variable between patients and over time, and the alarm rate and the extent of inter- and intra-patient variability can be affected by the alarm settings. Personalized alarm settings for a patient’s current status may help to reduce alarm fatigue for nurses.

59 BASIC BIOLOGICAL SCIENCES↗

Multiparameter fiber optic sensing system for monitoring enhanced geothermal systems

The goal of this project was to design, fabricate and test an optical fiber cable which supports multiple sensing modalities for measurements in the harsh environment of enhanced geothermal systems. To accomplish this task, optical fiber was tested at both high temperatures and strains for mechanical integrity, and in the presence of hydrogen for resistance to darkening. Both single mode (SM) and multimode (MM) commercially available optical fiber were identified and selected for the cable based on the results of these tests. The cable was designed and fabricated using a tube-within-tube construction containing two MM fibers and one SM fiber, and without supporting gel that is not suitable for high temperature environments. Commercial fiber optic sensing instruments using Raman DTS (distributed temperature sensing), Brillouin DTSS (distributed temperature and strain sensing), and Raleigh COTDR (coherent optical time domain reflectometry) were selected for field testing.

15 GEOTHERMAL ENERGY↗

Characterization of a Low-Cost Multiparameter Sensor for Solar Resource Applications

Low-cost, multiparameter sensing and measurement devices enable cost-effective monitoring of the functional, operational reliability, efficiency, and resiliency of the electric grid. The National Renewable Research Laboratory (NREL) Solar Radiation Research Laboratory (SRRL), in collaboration with Arable Labs, Inc., deployed Arable Lab's Mark multiparameter sensor system. The device measures the downwelling and upwelling shortwave solar resource and longwave radiation, humidity, air temperature, and ground temperature. The system is also equipped with six downward-and upward-facing narrowband spectrometer channels that measure spectral radiation and surface spectral reflectance. This study describes the shortwave calibration, characterization, and validation of measurement accuracy of this instrument by comparison with existing instruments that are part of NREL-SRRL's Baseline Measurement System.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-assimilated time-lapse visco-acoustic full-waveform inversion: Theory and application for injected CO 2 plume monitoring

Continuous seismic monitoring for quantifying CO 2 plume migration and detection of any potential leakages in the subsurface is essential for the security of long-term anthropogenic carbon dioxide geologic storage. Traditional time-lapse full-waveform inversion (TLFWI) methods aim to map the CO 2 distribution by estimating seismic velocity changes, but recent studies find that CO 2 -induced attenuation is an important complement to seismic velocity for tracking the CO 2 plumes and even quantifying the CO 2 saturation. We have developed a novel data-assimilated TLFWI method to construct high-resolution time-lapse velocity and attenuation changes from dense time-lapse monitoring data. This method consists of two theoretical developments: visco-acoustic full-waveform inversion (QFWI) and multiparameter hierarchical matrix-powered extended Kalman filter (mHiEKF). The method is capable of (1) posing temporal constraints to retrieve time-lapse information from dense monitoring data by using mHiEKF, (2) accurately recovering high-spatial-resolution velocity and attenuation perturbations using first-order equation system-based QFWI, and (3) providing the model uncertainty by estimating their model standard deviation. With numerical examples, we first find the effectiveness of the new QFWI on estimating accurate velocity and attenuation models simultaneously. Then, a CO 2 leakage case and a realistic Frio-II CO 2 monitoring case are presented to find the advantages and applicability of our data-assimilated QFWI method for estimating time-lapse changes using dense time-lapse monitoring surveys. Here, by assimilating time-lapse seismic monitoring data over time, our data-assimilated QFWI method can improve the resolution of velocity and attenuation changes and decrease their model uncertainties.

58 GEOSCIENCES↗

Multiparameter optical fiber sensing for energy infrastructure through nanoscale light–matter interactions: From hardware to software, science to commercial opportunities

Monitoring of energy infrastructure through robust yet economical sensing platforms is becoming an area of increased importance, with ubiquitous applications including the electrical grid, natural gas and oil transportation pipelines, H2 infrastructure (storage and transportation), carbon storage, power generation, and subsurface environments. Plasmonic and functional nanomaterial enabled fiber optic sensors show excellent promise for a wide range of sensing applications due to their versatility to be engineered for specific analytes of interest while retaining inherent advantages of the optical fiber sensor platform. Through the design of novel sensing layers, the optical transduction mechanism and wavelength dependence can also be tailored for ease of integration with low-cost interrogation systems enabling an inexpensive yet highly functional optical fiber sensing platform. In addition, recent advances in artificial intelligence and machine learning theoretical methods have been leveraged to simultaneously extract multiple parameters through multi-wavelength interrogation such that unique wavelengths can also serve as unique sensing elements, analogous to electronic nose sensor technologies. The concept of an optical fiber based “photonic nose” via multiple interrogation wavelengths and/or sensor nodes offers a compelling platform technology to realize multiparameter speciation of chemical analytes within complex gas mixtures. In this Perspective, we further generalize the notion of multiparameter sensing through the novel “photonic nervous system” concept based upon low-cost, functionalized optical fiber sensor probes monitoring a variety of distinct analyte classes (physical, chemical, electromagnetic, etc.) simultaneously to provide broad situational awareness via integrated sensors.

Su, Yang-Duan (ORCID:0000000214820902)↗

Multiparameter Outstation Agents for Cyber-Physical Electrical Grid Security and Restoration

This paper describes the development and deployment of cyberaware sensors to monitor the electrical grid and aid with disaster relief. These cyberaware sensors, outstation agents, provide information of multiple parameters simultaneously acting like a black box. The sensors embedded in the outstation agents and the communication architectures are described. These outstation agents are deployed around electrical substations in stationary and mobile platforms. The data collected from the outstation agents is sent to the utility control center providing information of the current status of the electrical grid. In the event of a disaster, the outstation agents make available information on the state of the grid, failures, and resources available to create an effective restoration pathway.

Morales Rodriguez, Marissa↗

Water Quality Trends in the Entiat River Subbasin: Final Annual Report to BPA and NOAA Fisheries, 2008.

The Integrated Status and Effectiveness Monitoring Project (ISEMP) program monitors the status and trend of water quality elements that may affect restoration project effectiveness in the Entiat subbasin. As part of this effort, the PNW Research Station (PNW) measures, analyzes and interprets temporal trends in natural stream water pH, dissolved oxygen, specific conductance and temperature. The Entiat River is currently on the Clean Water Act 303(d) list for pH exceedence, and there is insufficient information to determine the spatial and temporal extent or potential causes of this exceedence. In the late spring 2007, PNW deployed data-logging, multiparameter probes at four locations in the Entiat subbasin to measure water quality parameters, focusing on pH. Data collection was seasonally interrupted by river ice in early December. Daily average pH did not exceed the water quality standard of 8.5 at any of the measurements sites. However, instantaneous values did exceed this standard near the mouth of the Entiat River during late summer-fall period. This suggested that in the lowest portion of the river peaks in pH may be occurring because of photosynthesis caused by high rates of periphyton productivity in response to increased sunlight, temperature, and possible nutrient enrichment. Conversely, dissolved oxygen reached annual low levels during this same late summer-fall period, in part because of increased water temperatures and increased biochemical oxygen demand.

13 HYDRO ENERGY↗

Water Quality Trends in the Entiat River Subbasin: Final 2008 Annual Report.

The ISEMP program monitors the status and trend of water quality elements that may affect restoration project effectiveness in the Entiat subbasin. As part of this effort, the PNW Research Station (PNW) measures, analyzes and interprets temporal trends in natural stream water pH, dissolved oxygen, specific conductivity and temperature. The Entiat River is currently on the Clean Water Act 303(d) list for pH exceedence, and there is insufficient information to determine the spatial and temporal extent or potential causes of this exceedence. In the spring 2008, PNW redeployed data-logging, multiparameter probes at four locations in the Entiat subbasin to measure water quality parameters, focusing on pH. This resumed previous data collection that was interrupted by river ice in early December 2007. Instruments were again removed from the river in early December 2008. This annual report covers the period from December 2007 through December 2008. The highest pH values occurred during the low-flow period from midsummer through the following midspring then dropped sharply during the annual snowmelt runoff period from late spring through early summer. Water temperature began rapidly increasing during the receding limb of the annual snowmelt hydrograph. Highest mean monthly temperatures occurred in July and August, while instantaneous maxima occurred during the period July-September. Dissolved oxygen reached its lowest levels during the period of highest water temperature in July-September. Specific conductivity remained very low at all sites throughout the year.

13 HYDRO ENERGY↗

Characterization of a Low-Cost Multi-Parameter Sensor for Resource Applications: Preprint

Low-cost multi-parameter sensing and measurement devices enable cost-effective monitoring of the functional, operational reliability, efficiency, and resiliency of the electrical grid. The National Renewable Research Laboratory (NREL) Solar Radiation Research Laboratory (SRRL), in collaboration with Arable Labs Inc., deployed Arable Lab's Mark multi-parameter sensor system. The unique suite of system sensors measures the down-welling and upwelling shortwave solar resource and longwave radiation, humidity, air temperature, and ground temperature. This study describes the shortwave calibration, characteriza-tion, and validation of measurement accuracy of this instrument by comparison with existing instruments that are part of NREL-SRRL's Baseline Measurement System.

14 SOLAR ENERGY↗

Sensor-Equipped Unmanned Surface Vehicle for High-Resolution Mapping of Water Quality in Low- to Mid-Order Streams

Longitudinal profiling of water quality via the deployment of sensors from watercraft has advanced the understanding of spatial patterns in large rivers and lakes; however, a similar approach in low- to mid-order streams is lacking. To fill this gap, we developed an unmanned surface vehicle (USV)-water quality measurement platform (the “AquaBOT”). The components of the AquaBOT included a nitrate sensor, multiparameter sonde (temperature, conductivity, turbidity, dissolved oxygen, chlorophyll), quantum sensor, and global positioning system (GPS) mounted to a small pontoon-style USV. The AquaBOT was tested in four streams and rivers in Iowa and Tennessee. All measured water quality parameters varied longitudinally, and greater ranges were generally observed along the low-order, agriculturally influenced streams in Iowa. Nitrate, in particular, was spatially heterogeneous. For example, during one run in early June, concentrations ranged from 10.5 to 12.5 mg N L –1 along a 2.3 km reach and hotspots were observed directly downstream of some tile drains. The spatial resolution of AquaBOT data collected in June was 10× higher than grab sampling data, and measurements were collected in less time and at a comparable cost. Here, the AquaBOT can complement existing measurement approaches and will lead to advancements in understanding the processes driving water quality along the stream-to-river continuum.

47 OTHER INSTRUMENTATION↗