Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multiple-beam laser–plasma interactions in inertial confinement fusion

The experimental evidence for multiple-beam laser-plasma instabilities of relevance to laser driven inertial confinement fusion at the ignition scale is reviewed, in both the indirect and direct-drive approaches. The instabilities described are cross-beam energy transfer (in both indirectly driven targets on the NIF and in direct-drive targets), multiple-beam stimulated Raman scattering (for indirect-drive), and multiple-beam two-plasmon decay instability (in direct drive). Advances in theoretical understanding and in the numerical modeling of these multiple beam instabilities are presented.

Myatt, J. F.↗

Realizing in-plane surface diffraction by x-ray multiple-beam diffraction with large incidence angle

Based on rigorous dynamical-theory calculations, we demonstrate in this paper the principle of an x-ray multiple-beam diffraction (MBD) scheme that overcomes the long-lasting difficulties of high-resolution in-plane diffraction from crystal surfaces. This scheme only utilizes symmetric reflection geometry with large incident angles but activates the out-of-plane and in-plane diffraction processes simultaneously and separately in the continuous MBD planes. The in-plane diffraction is realized by detoured MBD, where the intermediate diffracted waves propagate parallel to the surface, which corresponds to an absolute Bragg surface diffraction configuration that is extremely sensitive to surface structures. Finally, a series of MBD diffraction and imaging techniques may be developed from this principle to study surface/interface (misfit) strains, lateral nanostructures, and phase transitions of a wide range of (pseudo)cubic crystal structures, including ultrathin epitaxial films and multilayers, quantum dots, strain-engineered semiconductor or (multi)ferroic materials, etc.

36 MATERIALS SCIENCE↗

X-ray topography using the forward transmitted beam under multiple-beam diffraction conditions

X-ray topographs are taken for a sapphire wafer with the [0001] surface normal, as an example, by forward transmitted synchrotron x-ray beams combined with two-dimensional electronic arrays in the x-ray detector having a spatial resolution of 1 μm. They exhibit no shape deformation and no position shift of the dislocation lines on the topographs. Since the topography is performed under multiple-beam diffraction conditions, the topographic images of a single diffraction (two-wave approximation condition) or plural diffractions (six-wave approximation condition) can be recorded without large specimen position changes. As usual Lang topographs, it is possible to determine the Burgers vector of each dislocation line. Because of high parallelism of the incoming x-rays and linear sensitivity of the electronic arrays to the incident x-rays, the present technique can be used to visualize individual dislocations in single crystals of the dislocation density as high as 1 × 10{sup 5} cm{sup −2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wave coupling in sheet- and multiple-beam traveling-wave tubes

To increase the power level of the sources of coherent electromagnetic radiation at frequencies from 100 GHz up to the terahertz range it makes sense to develop devices with a spatially extended interaction space. Sheet-beam and multiple-beam devices belong to the category. In the present paper the small-signal theory of traveling-wave tubes with sheet-beam and multiple sheet-beam configurations is developed. It is shown that in such tubes the wave coupling on electron beams may occur even in small-signal regimes. The wave coupling and its role for amplification of forward and excitation of backward waves in such amplifiers is studied. Also the effect of transverse nonuniformity of the electromagnetic field on the device operation is analyzed and illustrated by several examples.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiple Beam Triode Driven RF Sources for Accelerator Applications Phase I Final Report

Calabazas Creek Research, Inc, (CCR), in collaboration with Microwave Power Products, Inc. (MPP), formerly Communications & Power Industries, LLC (CPI,) and JP Accelerator Works, Inc. (JPAW), embarked on a program to develop multiple beam triodes to produce RF power from 350 – 800 MHz with an average power exceeding 200 kW. The effort was motivated by the performance of a triode-based RF source which produces 25 kW of UHF power at 90% efficiency. The CCR effort focused on implementing this technology into a multiple beam device to increase the output power while retaining the low cost, compact size, and high efficiency. The program performed extensive simulations indicating that the goals could be achieved, and a prototype multiple beam triode was built, baked, and tested. Unfortunately, a grid to cathode short terminated the testing before the tube could generate RF power. Nevertheless, the effort demonstrated that a multiple beam triode could be designed, built, baked, and energized to high voltage. The multiple beam triode used oxide cathodes, which are only capable of pulsed operation. The multiple beam triode will be rebuilt using dispenser cathodes, which will allow high duty or continuous operation. The grids were also modified to be more robust to avoid previous issues. The MB triode will provide the beam power for RF generation. The RF is generated by surrounding the triode with input and output cavities to convert beam power to RF power. RF cavities to generate 200 kW CW at 350-450 MHz using the MB triode with dispenser cathodes was assembled during the program. The next Phase of this effort is to assemble the multiple beam triode using the subassemblies built in the Phase I program and test with the RF cavities. The Phase I program also initiated design of a higher frequency, higher power multiple beam triode. That design is forecast to produce approximately 500 kW CW from 350 - 500 MHz.

43 PARTICLE ACCELERATORS↗

A 200 MHz 35 MW Multiple Beam Klystron for Accelerator Applications Final Report

Calabazas Creek Research, Inc. (CCR) performed initial development of a compact and reliable 35 MW, multiple beam klystron (MBK) at 200 MHz with a pulse length of 0.125 ms and a 30 Hz repetition rate. The device was targeted for acceleration and ionization cooling of a muon collider, but there are several other potential applications in this frequency range. The klystron uses multiple beams propagating in individual beam tunnels to reduce space charge and allow reduction in the accelerating voltage. This allows a significant reduction in length over a single beam source. More importantly this allows more efficient and less expensive power supplies. At 200 MHz, the interaction circuit for a single beam klystron would be more than six meters long to obtain 50% efficiency and 50 dB gain. This would require a beam voltage of approximately 400 kV and current of 251 A for a microperveance of 1.0. For an eight beam MBK with the same beam perveance, a three meter long interaction circuit achieves the same power and gain. Each beam operates at 142 kV and 70A. The Phase I demonstrated that this device could be fabricated with funding available in a Phase II program and could achieve the program specifications.

43 PARTICLE ACCELERATORS↗

Design of a Ku band miniature multiple beam klystron

The design of a miniature multiple beam klystron (MBK) working in the Ku-band frequency range is presented in this article. Starting from the main design parameters, design of the electron gun, the input and output couplers and radio frequency section (RF-section) are presented. The design methodology using state of the art commercial electromagnetic design tools, analytical formulae as well as noncommercial design tools are briefly presented in this article.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent combining of pulses amplified in wideband parametric amplifiers under multiple-beam pumping

The influence of fluctuations of pump beam parameters on the coherent combining efficiency of femtosecond pulses amplified in parametric amplifies based on LBO crystals under multiple- beam pumping is analysed. It is shown that in transition from a single-beam to two-beam pumping, the sensitivity of the parameters of amplified radiation to angular instability of the pump beams sharply increases. With increasing number of the pump beams, the sensitivity of the parameters to fluctuations of the pump beam propagation angle weakly varies. It is found that if a substantial number (n ≫ 1) of 2-cm-diameter beams amplified in parametric amplifiers under multiple-beam pumping are coherently combined, then obtaining the 98 % efficiency of this process requires the angular stabilisation of the pump beams better than 50 μrad. Fluctuations of other pump beam parameters such as energy, phase aberrations, and relative jitter either affect only the amplitude of the pulse amplified or the influence on the phase profile of the amplified beam is at most 10{sup −2} rad, which should not noticeably affect the coherent combining of amplified pulses. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Raman signal enhancement by multiple beam excitation and its application for the detection of chemicals

In a typical Raman based sensor, a single laser beam is used for exciting the sample and the backscattered or forward scattered light is collected using collection optics and is analyzed by a spectrometer. We have investigated that by means of exciting the sample with multiple beams, i.e., by dividing the same input power of the single beam into two or three or more beams and exciting the sample from different angles, the Raman signal enhances significantly. Due to the presence of multiple beams passing through the same volume of the sample, an interference pattern is formed and the volume of interaction of excitation beams with the sample increases. By means of this geometry, the enhancement in the Raman signal is observed and it was found that the signal strength increases linearly with the increase in number of excitation beams. Experimental results of this scheme for excitation of the samples are reported for explosive detection at a standoff distance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the use of a multiple beam optical sensor for in situ curvature monitoring in liquids

Several methods have been developed since the early 1900 to extract thin film stresses from the curvature of the substrate to which it is attached. One robust method particularly suitable for in situ curvature monitoring is the multiple beam optical sensor, which consists in measuring the change in relative spacings between parallel laser beams reflecting off the curved substrate. Although the technique is already well established for curvature monitoring in low pressure, gaseous environments, its use in liquid media has not yet received similar attention. Moreover, in the majority of the published work so far, spot spacings have been assumed to depend linearly on curvature. In this paper, it is first shown that this assumption may induce significant errors, particularly at large curvature. A more accurate set of equations is proposed. Next, the relationship between spot spacings and curvature is established when the substrate of interest is in a liquid, and a constitutive formula is proposed in that case as well. Finally, some practical aspects of the multiple beam technique for performing curvature measurements in a liquid are discussed. Various factors disturbing the measurement resolution are identified, with a specific interest for thin film anodizing, and a cell design is proposed to minimize their effect.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A polarization-switch effect of silicon crystals under multiple-beam diffraction geometry

On the basis of rigorous dynamical-theory calculations, a complete X-ray polarization-switch effect of silicon crystals at the exact multiple-beam diffraction condition is demonstrated in this paper. The underlying physical mechanism of this unique phenomenon can be revealed using a simple multiple-wave propagation and interference model. The constructive and destructive interference of the multiple detoured-diffraction beams along the direction of the primary diffracted beam directly leads to the complete polarization switch. This phenomenon can be realized using both synchrotron and laboratory X-ray sources at many discrete wavelengths, and used to design a novel crystal-based polarizer to achieve a 90° polarization rotation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-of-Flight Calculations with Multiple Beam Phase Monitors: Calibration, Jitter Analysis & Energy Measurement

This report describes time-of-flight (ToF) beam energy measurements with multiple phase monitors in a beam line with no acceleration. Measurement uncertainty is quantified via rigorous treatment of beam-based phase monitor calibration and jitter analysis of the accelerator system. Experimental results in the Superconducting Linac (SCL) of the Spallation Neutron Source (SNS) are presented.

43 PARTICLE ACCELERATORS↗

Uniformity simulation of multiple-beam irradiation of a spherical laser target with the inclusion of radiation absorption and refraction

We consider the physicomathematical model for the simulation of the angular laser flux distribution in a spherical target with the inclusion of radiation refraction in the corona. The irradiation uniformity is simulated using the target irradiation scheme on a megajoule multiple-beam laser facility. Calculations are made of the time-dependent angular distribution of absorbed flux and of the angular distribution of the time-integrated characteristic – the absorbed energy with allowance for the temporal shape of laser pulses – as well as of the time dependence of absorption efficiency. Different versions of target irradiation are considered. Under conventional irradiation it is assumed that the axes of all laser beams of equal energy pass through the target centre and the irradiation nonuniformity is due to its geometry only. Also examined are three unconventional irradiation versions: when there is a small spread of beam energies, when the target is displaced from the common beam pointing centre, and when the beam axes have small random deviations from the target centre. It is shown that the nonuniformity of the angular distribution of absorbed flux is greatest when the target is displaced from the beam pointing centre. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DXRD : a user-friendly suite of two- and multiple-beam dynamical X-ray diffraction programs

The DXRD program suite consisting of a series of dynamical theory programs is introduced for computing dynamical X-ray diffraction from single crystals. Its interactive graphical user interfaces (GUIs) allow general users to make complicated calculations with minimal effort. It can calculate plane-wave Darwin curves of single crystals (or multiple crystals) for both the Bragg and Laue cases, including grazing-incidence diffraction and backward diffraction (with Bragg angles approaching 90°). It is also capable of simulating rocking curves for divergent incident X-ray beams with finite bandwidths. A unique feature of DXRD is that it provides a convenient GUI-based multiple-beam diffraction program that can accurately compute arbitrary N-beam diffraction of any geometry using a universal 4N × 4N matrix method. DXRD also provides a mapping program for plotting all the multiple-beam diffraction lines (monochromator glitches) in the azimuth–energy coordinate system. All these functions make DXRD a convenient and powerful software tool for designing crystal-based synchrotron/X-ray optics (monochromators, analyzers, polarizers, phase plates etc.) and for crystal characterization, X-ray spectroscopy and X-ray diffraction teaching.

Bragg reflection↗

Multiple Beam Two-Plasmon Decay: Linear Threshold to Nonlinear Saturation in Three Dimensions

The linear stability of multiple coherent laser beams with respect to two-plasmon-decay instability in an inhomogeneous plasma in three dimensions has been determined. Cooperation between beams leads to absolute instability of long-wavelength decays, while shorter-wavelength shared waves are shown to saturate convectively. The multibeam, in its absolutely unstable form, has the lowest threshold for most cases considered. Finally, nonlinear calculations using a three-dimensional extended Zakharov model show that Langmuir turbulence created by the absolute instability modifies the convective saturation of the shorter-wavelength modes, which are seen to dominate at late times.

42 ENGINEERING↗

Comparing Radiation Treatments Using Intensity-Modulated Beams, Multiple Arcs, and Single Arcs

Purpose: A dosimetric comparison of multiple static-field intensity-modulated radiation therapy (IMRT), multiarc intensity-modulated arc therapy (IMAT), and single-arc arc-modulated radiation therapy (AMRT) was performed to evaluate their clinical advantages and shortcomings. Methods and Materials: Twelve cases were selected for this study, including three head-and-neck, three brain, three lung, and three prostate cases. An IMRT, IMAT, and AMRT plan was generated for each of the cases, with clinically relevant planning constraints. For a fair comparison, the same parameters were used for the IMRT, IMAT, and AMRT planning for each patient. Results: Multiarc IMAT provided the best plan quality, while single-arc AMRT achieved dose distributions comparable to those of IMRT, especially in the complicated head-and-neck and brain cases. Both AMRT and IMAT showed effective normal tissue sparing without compromising target coverage and delivered a lower total dose to the surrounding normal tissues in some cases. Conclusions: IMAT provides the most uniform and conformal dose distributions, especially for the cases with large and complex targets, but with a delivery time similar to that of IMRT; whereas AMRT achieves results comparable to IMRT with significantly faster treatment delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗