Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplicative correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An algebraic convolution formulation for multiple-scattering correction in small-angle neutron scattering

Multiple scattering in small-angle neutron scattering (SANS) redistributes spectral weight and distorts structural interpretation, particularly for thick or strongly scattering samples. We develop a finite-dimensional spectral desmearing framework that corrects multiple scattering without resorting to integral transforms or model-dependent extrapolation. The primary intensity is expanded in an orthonormal basis adapted to the isotropic transverse-momentum measure, under which convolution reduces to a recursive tensor contraction, allowing the Poisson-weighted multiple-scattering series to be evaluated directly in a finite-dimensional basis representation. This formulation yields a stable forward–inverse mapping between apparent and primary spectra. Numerical tests demonstrate convergence under repeated convolution and accurate recovery of the single-scattering intensity. Application to SANS measurements collected at multiple neutron facilities, including the Spallation Neutron Source, the High Flux Isotope Reactor, and the Institut Laue-Langevin, shows the quantitative reconstruction of the underlying primary spectrum across a wide range of transmission conditions, including strongly attenuating samples. Here, the method provides a stable, model-agnostic framework for multiple-scattering correction in SANS and enables consistent structural interpretation across instruments and scattering regimes.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

Method for measuring multiple scattering corrections between liquid scintillators

In this study, a time-of-flight method is proposed to experimentally quantify the fractions of neutrons scattering between scintillators. An array of scintillators is characterized in terms of crosstalk with this method by measuring a californium source, for different neutron energy thresholds. The spectral information recorded by the scintillators can be used to estimate the fractions of neutrons multiple scattering. With the help of a correction to Feynman's point model theory to account for multiple scattering, these fractions can in turn improve the mass reconstruction of fissile materials under investigation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Broadband distortion modeling in Lyman-α forest BAO fitting

Recently, the Lyman-α absorption observed in the spectra of high-redshift quasars has been used as a tracer of large-scale structure by means of the three-dimensional Lyman-α forest auto-correlation function at redshift z≃ 2.3, but the need to fit the quasar continuum in every absorption spectrum introduces a broadband distortion that is difficult to correct and causes a systematic error for measuring any broadband properties. Here, we describe a k-space model for this broadband distortion based on a multiplicative correction to the power spectrum of the transmitted flux fraction that suppresses power on scales corresponding to the typical length of a Lyman-α forest spectrum. In implementing the distortion model in fits for the baryon acoustic oscillation (BAO) peak position in the Lyman-α forest auto-correlation, we find that the fitting method recovers the input values of the linear bias parameter b F and the redshift-space distortion parameter β F for mock data sets with a systematic error of less than 0.5%. Applied to the auto-correlation measured for BOSS Data Release 11, our method improves on the previous treatment of broadband distortions in BAO fitting by providing a better fit to the data using fewer parameters and reducing the statistical errors on βF and the combination b F (1+β F ) by more than a factor of seven. The measured values at redshift z=2.3 are βF=1.39 +0.11 +0.24 +0.38 -0.10 -0.19 -0.28 and bF(1+βF)=-0.374 +0.007 +0.013 +0.020 -0.007 -0.014 -0.022 (1σ, 2σ and 3σ statistical errors). Our fitting software and the input files needed to reproduce our main results are publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗

Towards the clinical implementation of iterative low-dose cone-beam CT reconstruction in image-guided radiation therapy: Cone/ring artifact correction and multiple GPU implementation

Purpose: Compressed sensing (CS)-based iterative reconstruction (IR) techniques are able to reconstruct cone-beam CT (CBCT) images from undersampled noisy data, allowing for imaging dose reduction. However, there are a few practical concerns preventing the clinical implementation of these techniques. On the image quality side, data truncation along the superior–inferior direction under the cone-beam geometry produces severe cone artifacts in the reconstructed images. Ring artifacts are also seen in the half-fan scan mode. On the reconstruction efficiency side, the long computation time hinders clinical use in image-guided radiation therapy (IGRT). Methods: Image quality improvement methods are proposed to mitigate the cone and ring image artifacts in IR. The basic idea is to use weighting factors in the IR data fidelity term to improve projection data consistency with the reconstructed volume. In order to improve the computational efficiency, a multiple graphics processing units (GPUs)-based CS-IR system was developed. The parallelization scheme, detailed analyses of computation time at each step, their relationship with image resolution, and the acceleration factors were studied. The whole system was evaluated in various phantom and patient cases. Results: Ring artifacts can be mitigated by properly designing a weighting factor as a function of the spatial location on the detector. As for the cone artifact, without applying a correction method, it contaminated 13 out of 80 slices in a head-neck case (full-fan). Contamination was even more severe in a pelvis case under half-fan mode, where 36 out of 80 slices were affected, leading to poorer soft tissue delineation and reduced superior–inferior coverage. The proposed method effectively corrects those contaminated slices with mean intensity differences compared to FDK results decreasing from ∼497 and ∼293 HU to ∼39 and ∼27 HU for the full-fan and half-fan cases, respectively. In terms of efficiency boost, an overall 3.1 × speedup factor has been achieved with four GPU cards compared to a single GPU-based reconstruction. The total computation time is ∼30 s for typical clinical cases. Conclusions: The authors have developed a low-dose CBCT IR system for IGRT. By incorporating data consistency-based weighting factors in the IR model, cone/ring artifacts can be mitigated. A boost in computational efficiency is achieved by multi-GPU implementation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiple-scattering Corrections to Measurements of the Prompt Fission Neutron Spectrum

The Chi-Nu project, conducted jointly by LANL and LLNL, aims to measure the shape of the prompt fission neutron spectrum (PFNS) for fission of {sup 239}Pu induced by neutrons from 50 keV to 15 MeV with accuracies of 3–5% in the outgoing energy from 50 keV to 9 MeV and 15% from 9 to 15 MeV. In order to meet this goal, detailed Monte Carlo simulations are being used to assess the importance and effect of every component in the experimental configuration. As part of this effort, we have also simulated some past PFNS measurements to identify possible sources of systematic error. We find that multiple scattering plays an important role in the target geometry, collimators, and detector response and that past experiments probably underestimated the extent of this effect.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An event-triggered coincidence algorithm for fast-neutron multiplicity assay corrected for cross-talk and photon breakthrough

Here, a model quantifying detector cross-talk and the misidentification of events in fast neutron coincidence distributions is described. This is demonstrated for two experimental arrangements comprising rings of 8 and 15 organic liquid scintillation detectors. Correction terms developed as part of this model are tested with 252 Cf and a relationship is developed between the 235 U enrichment of U 3 O 8 and the order of correlated, fast neutron multiplets induced by an americium–lithium source. The model is also supported by Geant4 simulations. The results suggest that a typical assay, for experimental arrangements that are similar to the examples investigated in this research, will exhibit cross-talk for less than 1% of all detected fast neutrons but, if not accounted for, this can bias the numerical analysis by a margin of 10% and 35% in second- and third-order coincidences (i.e. couplet and triplet counts), respectively. Further, for the case of 252 Cf, it is shown that a relatively low proportion of 4% breakthrough by rays (that is, photons misidentified as neutrons by the pulse-shape discrimination process) can lead to an erroneous increase of 20% in total neutron counts in the assay of a mixed-field, in this case of 252 Cf. These findings will help direct the developments needed to enable organic scintillation detectors with pulse shape discriminators to be applied reliably to nuclear safeguards and non-proliferation verification tasks.

42 ENGINEERING↗

MCNPX270 LLNL Fission Model

The LLNL fission model is an available option in MCNPX version 2.7.0. It was developed at Lawrence Livermore National Laboratory and we have collaborated to implement it in MCNPX. We report here our observations and assessments of the LLNL fission model in MCNPX relative to alternative treatments in MCNPX. The LLNL fission model is the only way for MCNPX to produce correlated prompt gammas from prompt fission, delayed fission, spontaneous fission, and photofission. The LLNL fission model also produces fission neutrons and gammas with the correct multiplicities for induced fission, spontaneous fission, and photofission. The exact modeling of the neutron- and photon-induced fission process enables coincidence counting of fission neutrons and gammas. Comparisons were made to the MCNPX default fission capability which uses ACE table physics and the default fmult fission multiplicity capability. Also, several corrections were made in MCNPX27E and these are described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of the Gill-Solent WindMaster-Pro “w-boost” firmware bug on eddy covariance fluxes and some simple recovery strategies

In late 2015 and early 2016, work done by the AmeriFlux Management Project Technical Team (amerilfux.lbl.gov) helped to uncover an issue with Gill WindMaster and WindMaster Pro sonic anemometers used by many researchers for eddy covariance flux measurements. Gill has addressed this issue and has since sent out a notice that the vertical wind speed component (a critical piece of all eddy covariance fluxes) was being erroneously computed and reported. The problem (known as the “w-boost” bug) ended in positive (upward) wind speeds being under-reported by 16.6% and negative (downward) wind speeds being under-reported by 28.9%. This has the possibility to cause similar under estimates in fluxes derived from measurements using these instruments. Additionally, the bug affects corrections for angle of attack as derived by Nakai and Shimoyama, rendering them invalid. Although the manufacturer has offered a firmware upgrade for existing instruments that will fix this issue, many existing data sets have been affected by it and are currently in use by the scientific community. To address the issue of affected data, currently in use, we analyzed multi-year and short-term data sets from a variety of ecosystems to assess methods of correcting existing flux data. We found that simple multiplicative correction factors (~1.18) may be used to remove most of the “w-boost” bias from fluxes in existing data sets that do not include angle of attack corrections.

54 ENVIRONMENTAL SCIENCES↗

AMICE2 measurements of lab-generated and ambient aerosols at BNL from 2025-07-21 to 2025-08-22

From July 21 through August 22, 2025 the Absorption Measurement Inter-Comparison Experiment phase 2 (AMICE2) was conducted at Brookhaven National Laboratory. The experiment included concurrent operation of several filter-based instruments and in situ instruments sampling from a common sample line. The common sample line provided all instruments with either lab-generated aerosols composed of external mixtures of nigrosin, cabojet, and ammonium sulfate, or with ambient aerosol drawn through an external stack. This data set contains measurements from the CAPS PMssa instrument taken as a reference instrument at 532 nm and against which the effectiveness of the filter corrections may be assessed. It also contains attenuation coefficients from all filter-based instruments and filter transmittances in order to permit correction for filter loading, and the SSA and COA to permit corrections for aerosol darkness. Finally, two sets of multiplicative corrections are provided for the AE-33, TAP, and MA-350 instruments: the first one, Corr1, corrects for filter amplification factor and loading, the second one, Corr2, corrects for the aerosol darkness in terms of the natural log of COA.

Aerosol Extinction↗

Decoupled recovery of energy and momentum with correction of n = 2 error fields

Experiments applying known n = 2 “proxy” error fields (EFs) find that the rotation braking introduced by the proxy EF cannot be completely alleviated through optimal n = 2 correction with poorly matched poloidal spectra. This imperfect performance recovery demonstrates the importance of correcting multiple components of the n = 2 field spectrum and is in contrast to previous results with n = 1 EFs despite similar execution. Measured optimal n = 2 proxy EF correction currents are consistent with those required to null dominant mode coupling to the resonant surfaces and minimize the neoclassical toroidal viscosity (NTV) torque, calculated using ideal MHD plasma response computation. Unlike rotation braking, density pumpout can be fully corrected despite poorly matched spectra, indicating density pumpout is driven only by a single component proportional to the resonant coupling. Through precise n = 2 spectral control density pumpout and rotation braking can thus be decoupled. Rotation braking with n = 2 fields is also found to be proportional to the level of concurrent toroidal rotation, consistent with NTV theory. Lastly, plasmas with modest countercurrent rotation are insensitive to the n = 2 field with neither rotation braking nor density pumpout observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RESOLVING THE COSMIC FAR-INFRARED BACKGROUND AT 450 AND 850 μm WITH SCUBA-2

We use the SCUBA-2 submillimeter camera mounted on the James Clerk Maxwell Telescope to obtain extremely deep number counts at 450 and 850 μm. We combine data on two cluster lensing fields, A1689 and A370, and three blank fields, CDF-N, CDF-S, and COSMOS, to measure the counts over a wide flux range at each wavelength. We use statistical fits to broken power law representations to determine the number counts. This allows us to probe to the deepest possible level in the data. At both wavelengths our results agree well with the literature in the flux range over which they have been measured, with the exception of the 850 μm counts in CDF-S, where we do not observe the counts deficit found by previous single-dish observations. At 450 μm, we detect significant counts down to ∼1 mJy, an unprecedented depth at this wavelength. By integrating the number counts above this flux limit, we measure 113.9{sup +49.7}{sub -28.4} Jy deg{sup –2} of the 450 μm extragalactic background light (EBL). The majority of this contribution is from sources with S{sub 450{sub μm}} between 1-10 mJy, and these sources are likely to be the ones that are analogous to the local luminous infrared galaxies. At 850 μm, we measure 37.3{sup +21.1}{sub -12.9} Jy deg{sup –2} of the EBL. Because of the large systematic uncertainties on the COBE measurements, the percentage of the EBL we resolve could range from 48%-153% (44%-178%) at 450 (850) μm. Based on high-resolution Submillimeter Array observations of around half of the 4 σ 850 μm sample in CDF-N, we find that 12.5{sup +12.1}{sub -6.8}% of the sources are blends of multiple fainter sources. This is a low multiple fraction, and we find no significant difference between our original SCUBA-2 850 μm counts and the multiplicity-corrected counts.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte Carlo calculation of the average neutron depolarization for the NPDGamma experiment

The NPDGamma experiment measures the asymmetry in γ-ray emission in the capture of polarized neutrons on liquid parahydrogen. The beam polarization is measured using 3 He spin analysis, but this measurement does not account for the contribution of depolarization from spin–flip scattering primarily due to orthohydrogen in the bulk liquid. This is a systematic effect that dilutes the experimental asymmetry and is modeled using Monte Carlo. Finally, methods for tracking neutron spin in MCNPX were developed in order to calculate the average neutron polarization upon capture for use as a multiplicative correction to the measured beam polarization for the NPDGamma experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reply to ''Comment on 'Modal expansion approach to optical-frequency-comb generation with monolithic whispering-gallery-mode resonators'''

In a Comment [Deych, Phys. Rev. A 84, 017801 (2011)] on our recent article [Chembo and Yu, Phys. Rev. A 82, 033801 (2010)] on Kerr comb generation in monolithic whispering-gallery-mode (WGM) resonators, the author claims that even though our main results ''remain intact'', the framework of our analysis contains some mathematical errors. In this Reply, we demonstrate that the author's criticisms and his alternative theory are incorrect, and that all the disagreeing claims come from the author's misunderstanding of the physical system under investigation. In particular, the main conceptual error in the Comment is the confusion between evanescent and radiative coupling mechanisms for WGM resonators (in terms of Q factor, this is in our case a confusion between {approx}10{sup 9} and {approx}10{sup 2000}, respectively). This essential misconception leads for example the author to introduce a nonphysical {approx}10{sup 2000} multiplicative correction factor for the laser pump power. We show in this Reply that our WGM resonators are radiatively closed (because of the quasi-infinite radiative Q factor), so that the Mie scattering formalism proposed by Deych, which relies on radiative coupling, can only lead to erroneous results. We also show that the modal expansion approach in our original paper is appropriate, and all our approximations are physically well justified. We therefore stand by our modeling results, which are moreover in excellent agreement with the experiments reported in [Chembo, Strekalov, and Yu, Phys. Rev. Lett. 104, 103902 (2010)].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Final Technical Report for DE-SC0012297

This is the final report on the work performed in award DE-SC0012297, Cosmic Frontier work in support of the LSST Dark Energy Science Collaboration's work to develop algorithms, simulations, and statistical tests to ensure optimal extraction of the dark energy properties from galaxy clusters observed with LSST. This work focused on effects that could produce a systematic error on the measurement of cluster masses (that will be used to probe the effects of dark energy on the growth of structure). These effects stem from the deviations from pure ellipticity of the gravitational lensing signal and from the blending of light of neighboring galaxies. Both these effects are expected to be more significant for LSST than for the stage III experiments such as the Dark Energy Survey. We calculate the magnitude of the mass error (or bias) for the first time and demonstrate that it can be treated as a multiplicative correction and calibrated out, allowing mass measurements of clusters from gravitational lensing to meet the requirements of LSST's dark energy investigation.

79 ASTRONOMY AND ASTROPHYSICS↗

BASS. XXV. DR2 Broad-line-based Black Hole Mass Estimates and Biases from Obscuration

We present measurements of broad emission lines and virial estimates of supermassive black hole masses (M BH ) for a large sample of ultrahard X-ray-selected active galactic nuclei (AGNs) as part of the second data release of the BAT AGN Spectroscopic Survey (BASS/DR2). Our catalog includes M BH estimates for a total of 689 AGNs, determined from the Hα, Hβ, Mg II λ2798, and/or C IV λ1549 broad emission lines. The core sample includes a total of 512 AGNs drawn from the 70 month Swift/BAT all-sky catalog. We also provide measurements for 177 additional AGNs that are drawn from deeper Swift/BAT survey data. We study the links between M BH estimates and line-of-sight obscuration measured from X-ray spectral analysis. We find that broad Hα emission lines in obscured AGNs ($\mathrm{log}({N}_{{\rm{H}}}/{\mathrm{cm}}^{-2})\gt 22.0$) are on average a factor of ${8.0}_{-2.4}^{+4.1}$ weaker relative to ultrahard X-ray emission and about ${35}_{-12}^{\,+7}$% narrower than those in unobscured sources (i.e., $\mathrm{log}({N}_{{\rm{H}}}/{\mathrm{cm}}^{-2})\lt 21.5$). This indicates that the innermost part of the broad-line region is preferentially absorbed. Consequently, current single-epoch M BH prescriptions result in severely underestimated (>1 dex) masses for Type 1.9 sources (AGNs with broad Hα but no broad Hβ) and/or sources with $\mathrm{log}({N}_{{\rm{H}}}/{\mathrm{cm}}^{-2})\gtrsim 22.0$. We provide simple multiplicative corrections for the observed luminosity and width of the broad Hα component (L[bHα] and FWHM[bHα]) in such sources to account for this effect and to (partially) remedy M BH estimates for Type 1.9 objects. As a key ingredient of BASS/DR2, our work provides the community with the data needed to further study powerful AGNs in the low-redshift universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Demystifying Piecewise and Localized Scatter Correction Methods

Multiplicative scatter is a common source of noise in near-infrared spectroscopy and other related instrumental techniques. A wide variety of methods are commonly used for the correction of multiplicative scatter. However, the majority of such methods assume that the parameters that describe the scatter are constant throughout the measured spectrum, which is often not the case. This work investigates a family of methods that perform scatter correction using local regions of neighboring wavelengths in order to better account for wavelength-dependent scattering. The methods in question are piecewise standard normal variate, localized standard normal variate, piecewise multiplicative scatter correction, and localized multiplicative scatter correction. This work describes the theoretical and algorithmic foundations of the family of local region-based scatter correction methods and compares their application and optimization at a qualitative and quantitative level using several datasets.

NIR spectroscopy↗

SPITZER SECONDARY ECLIPSE DEPTHS WITH MULTIPLE INTRAPIXEL SENSITIVITY CORRECTION METHODS OBSERVATIONS OF WASP-13b, WASP-15b, WASP-16b, WASP-62b, AND HAT-P-22b

We measure the 4.5 μ m thermal emission of five transiting hot Jupiters, WASP-13b, WASP-15b, WASP-16b, WASP-62b, and HAT-P-22b using channel 2 of the Infrared Array Camera (IRAC) on the Spitzer Space Telescope . Significant intrapixel sensitivity variations in Spitzer IRAC data require careful correction in order to achieve precision on the order of several hundred parts per million (ppm) for the measurement of exoplanet secondary eclipses. We determine eclipse depths by first correcting the raw data using three independent data reduction methods. The Pixel Gain Map (PMAP), Nearest Neighbors (NNBR), and Pixel Level Decorrelation (PLD) each correct for the intrapixel sensitivity effect in Spitzer photometric time-series observations. The results from each methodology are compared against each other to establish if they reach a statistically equivalent result in every case and to evaluate their ability to minimize uncertainty in the measurement. We find that all three methods produce reliable results. For every planet examined here NNBR and PLD produce results that are in statistical agreement. However, the PMAP method appears to produce results in slight disagreement in cases where the stellar centroid is not kept consistently on the most well characterized area of the detector. We evaluate the ability of each method to reduce the scatter in the residuals as well as in the correlated noise in the corrected data. The NNBR and PLD methods consistently minimize both white and red noise levels and should be considered reliable and consistent. The planets in this study span equilibrium temperatures from 1100 to 2000 K and have brightness temperatures that require either high albedo or efficient recirculation. However, it is possible that other processes such as clouds or disequilibrium chemistry may also be responsible for producing these brightness temperatures.

79 ASTRONOMY AND ASTROPHYSICS↗