Search NASASearch

SEARCH · Search NASA

Results for “multispectral ground-based imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thermal surveillance of Cascade Range volcanoes using ERTS-1 multispectral scanner, aircraft imaging systems, and ground-based data communication platforms

A combination of infrared images depicting areas of thermal emission and ground calibration points have proved to be particularly useful in plotting time-dependent changes in surface temperatures and radiance and in delimiting areas of predominantly convective heat flow to the earth's surface in the Cascade Range and on Surtsey Volcano, Iceland. In an integrated experiment group using ERTS-1 multispectral scanner (MSS) and aircraft infrared imaging systems in conjunction with multiple thermistor arrays, volcano surface temperatures are relayed daily to Washington via data communication platform (DCP) transmitters and ERTS-1. ERTS-1 MSS imagery has revealed curvilinear structures at Lassen, the full extent of which have not been previously mapped. Interestingly, the major surface thermal manifestations at Lassen are aligned along these structures, particularly in the Warner Valley.

Friedman, J. D.

Highly Protable Airborne Multispectral Imaging System

A portable instrumentation system is described that includes and airborne and a ground-based subsytem. It can acquire multispectral image data over swaths of terrain ranging in width from about 1.5 to 1 km. The system was developed especially for use in coastal environments and is well suited for performing remote sensing and general environmental monitoring. It includes a small,munpilotaed, remotely controlled airplance that carries a forward-looking camera for navigation, three downward-looking monochrome video cameras for imaging terrain in three spectral bands, a video transmitter, and a Global Positioning System (GPS) reciever.

Lehnemann, Robert

Multispectral mapping of the lunar surface using ground-based telescopes

Images of the lunar surface were obtained at several wavelengths using a silicon vidicon imaging system and ground-based telescopes. These images were recorded and processed in digital form so that quantitative information was preserved. The photometric precision of the images is shown to be better than 1%. Ratio images calculated by dividing images obtained at two wavelengths (0.40/0.56 and 0.95/0.56 microns) are presented for about 50% of the lunar frontside. Spatial resolution is about 2 km at the subearth point. A complex of distinct units is evident in the images. Earlier work with the reflectance spectrum of lunar materials indicates that, for the most part, these units are compositionally distinct.

Mccord, T. B.

On-board multispectral classification study

The factors relating to onboard multispectral classification were investigated. The functions implemented in ground-based processing systems for current Earth observation sensors were reviewed. The Multispectral Scanner, Thematic Mapper, Return Beam Vidicon, and Heat Capacity Mapper were studied. The concept of classification was reviewed and extended from the ground-based image processing functions to an onboard system capable of multispectral classification. Eight different onboard configurations, each with varying amounts of ground-spacecraft interaction, were evaluated. Each configuration was evaluated in terms of turnaround time, onboard processing and storage requirements, geometric and classification accuracy, onboard complexity, and ancillary data required from the ground.

Ewalt, D.

Lunar and Planetary Science XXXV: Lunar Remote Sensing: Fire, Ice, and Regolith

The session "Lunar Remote Sensing: Fire, Ice, and Regolith" included the following:Compositional and Structural Study of the Aristarchus Plateau from Integrated UV-VIS-NIR Spectral Data; Clementine 2.7-?m Data: Mapping the Mare and Searching for Water; On the Search for Water at the Lunar Poles: Results of Forward Modeling of Permanently Shaded Areas and Lunar Prospector Measurements; Searching the Moon for Aluminous Mare Basalts Using Compositional Remote-Sensing Constraints I: Finding the Regions of Interest; Semi-automated Extraction of Contours from Lunar Topographic Maps; Basalts in Mare Humorum and S.E. Procellarum; The Hansteen and Helmet Volcanic Dome Regions on the Moon: Stratigraphy and Ages; Derivation of Elemental Abundance Maps at 15-km Spatial Resolution from the Merging of Clementine Optical and Lunar Prospector Geochemical Data; Remote Sensing and Geologic Studies of the Balmer Region of the Moon; Lava Flows in Mare Nubium and Mare Cognitum: A Geological History Based on Analysis of Multispectral Data; Development of Ground-based Lunar VIS/NEAR IR Spectral Imager; A BRDF Measurement Apparatus for Lab-based Samples; A New Source of High Resolution Lunar Images: Amateur Astronomers! ; Leakage of Gamma Rays and Neutrons from Thick Targets Bombarded by Energetic Protons; Progress on Reviving Lunar Orbiter: Scanning, Archiving, and Cartographic Processing at USGS; Modeling Lateral and Vertical Mixing by Impact Cratering with Applications for the Moon; Optical Maturity Study of Stuart#s Crater Candidate Impact; Evidence for Three Basins Beneath Oceanus Procellarum; and Ellipses of the South Pole-Aitken Basin: Implications for Basin Formation.

Source record

Lunar multispectral maps - Part II of the lunar nearside

Images of the lunar surface are being obtained at several wavelengths using a silicon vidicon imaging system and ground-based telescopes. These images are recorded and processed in digital form so that quantitative information is preserved; their photometric precision has been shown to be 1% or better. Ratio images, calculated by dividing those obtained at two wavelengths (0.40/0.56 and 0.95/0.56 micron), were presented in an earlier article, and more are presented here for a total coverage of about 60% of the lunar frontside. Spatial resolution is about 2 km at the subearth point. A complex of distinct units is evident in the images. Earlier work with the reflectance spectrum of lunar materials indicates that for the most part these units are compositionally distinct. These digital images are being used by lunar geologists to interpret the history of the lunar surface.

Mccord, T. B.

A Portable Ground-Based Atmospheric Monitoring System (PGAMS) for the Calibration and Validation of Atmospheric Correction Algorithms Applied to Aircraft and Satellite Images

Detecting changes in the Earth's environment using satellite images of ocean and land surfaces must take into account atmospheric effects. As a result, major programs are underway to develop algorithms for image retrieval of atmospheric aerosol properties and atmospheric correction. However, because of the temporal and spatial variability of atmospheric transmittance it is very difficult to model atmospheric effects and implement models in an operational mode. For this reason, simultaneous in situ ground measurements of atmospheric optical properties are vital to the development of accurate atmospheric correction techniques. Presented in this paper is a spectroradiometer system that provides an optimized set of surface measurements for the calibration and validation of atmospheric correction algorithms. The Portable Ground-based Atmospheric Monitoring System (PGAMS) obtains a comprehensive series of in situ irradiance, radiance, and reflectance measurements for the calibration of atmospheric correction algorithms applied to multispectral. and hyperspectral images. The observations include: total downwelling irradiance, diffuse sky irradiance, direct solar irradiance, path radiance in the direction of the north celestial pole, path radiance in the direction of the overflying satellite, almucantar scans of path radiance, full sky radiance maps, and surface reflectance. Each of these parameters are recorded over a wavelength range from 350 to 1050 nm in 512 channels. The system is fast, with the potential to acquire the complete set of observations in only 8 to 10 minutes depending on the selected spatial resolution of the sky path radiance measurements

Schiller, Stephen

Radiometric Characterization of IKONOS Multispectral Imagery

A radiometric characterization of Space Imaging's IKONOS 4-m multispectral imagery has been performed by a NASA funded team from the John C. Stennis Space Center (SSC), the University of Arizona Remote Sensing Group (UARSG), and South Dakota State University (SDSU). Both intrinsic radiometry and the effects of Space Imaging processing on radiometry were investigated. Relative radiometry was examined with uniform Antarctic and Saharan sites. Absolute radiometric calibration was performed using reflectance-based vicarious calibration methods on several uniform sites imaged by IKONOS, coincident with ground-based surface and atmospheric measurements. Ground-based data and the IKONOS spectral response function served as input to radiative transfer codes to generate a Top-of-Atmosphere radiance estimate. Calibration coefficients derived from each vicarious calibration were combined to generate an IKONOS radiometric gain coefficient for each multispectral band assuming a linear response over the full dynamic range of the instrument. These calibration coefficients were made available to Space Imaging, which subsequently adopted them by updating its initial set of calibration coefficients. IKONOS imagery procured through the NASA Scientific Data Purchase program is processed with or without a Modulation Transfer Function Compensation kernel. The radiometric effects of this kernel on various scene types was also investigated. All imagery characterized was procured through the NASA Scientific Data Purchase program.

Pagnutti, Mary

Radiometric Calibration of the AWiFS Using Vicarious Calibration Techniques

A radiometric calibration assessment of the AWiFS (Advanced Wide Field Sensor) on the Indian Remote Sensing Resourcesat-1 satellite was performed by the NASA Applied Research & Technology Project Office (formerly the Applied Sciences Directorate) at the John C. Stennis Space Center. A reflectance-based vicarious calibration approach, requiring ground-based measurements coincident with satellite acquisitions and radiative transfer calculations, was used to estimate at-sensor radiance. The AWiFS is a 4-band, multispectral, moderate-resolution (60 m) imaging sensor that operates in the visible through short-wave infrared spectrum and is currently being considered as a Landsat-like alternative. Several study sites near the Stennis Space Center that attempted to span the dynamic range of the sensor were employed. Satellite at-sensor radiance values were compared to those estimated to determine the sensor's radiometric accuracy. The results of this evaluation provide the user community with an independent assessment of the radiometric accuracy of AWiFS image products, which are commercially available through GeoEye. These results are an extension of an independent assessment made by the University of Arizona Remote Sensing Group, the South Dakota State University Satellite Calibration Group & Image Processing Lab, and the NASA Applied Sciences Directorate at the John C. Stennis Space Center the previous year.

Pagnutti, Mary

Cirrus cloud characteristics derived from volume imaging lidar, high spectral resolution lidar, HIS radiometer, and satellite

Preliminary measurement results are presented from the Cirrus Remote Sensing Pilot Experiment which used a unique suite of instruments to simultaneously retrieve cirrus cloud visible and IR optical properties, while addressing the disparities between satellite volume averages and local point measurements. The experiment employed a ground-based high resolution interferometer sounder (HIS) and a second Fourier transform spectrometer to measure the spectral radiance in the 4-20 micron band, a correlated high spectral resolution lidar, a volume imaging lidar, a CLASS radiosonde system, the Scripps Whole Sky Imager, and multispectral VAS, HIRS, and AVHRR satellite data from polar orbiting and geostationary satellites. Data acquired during the month long experiment included continuous daytime monitoring with the Whole Sky Imager.

Grund, Christian J.

Laboratory Measurement of Bidirectional Reflectance of Radiometric Tarps

Objectives: a) To determine the magnitude of radiometric tarp BRDF; b) To determine whether an ASD FieldSpec Pro spectroradiometer can be used to perform the experiment. Radiometric tarps with nominal reflectance values of 52%, 35%, and 3.5%, deployed for IKONOS. QuickBird, and OrbView-3 overpasses Ground-based spectroradiometric measurements of tarp and Spectralon@ panel taken during overpass using ASD FieldSpec Pro spectroradiometer, and tarp reflectance calculated. Reflectance data used in atmospheric radiative transfer model (MODTRAN) to predict satellite at-sensor radiance for radiometric calibration. Reflectance data also used to validate atmospheric correction of high-spatial-resolution multispectral image products

Knowlton, Kelly

International Geoscience and Remote Sensing Symposium, Universitaet Muenchen, Munich, West Germany, June 1-4, 1982, Proceedings

The present conference on geoscience and remote sensing considers the multispectral remote sensing of saline seeps, the augmentation of LANDSAT MSS data with topographic data, thematic mapping, the sampling problem in radiation budget studies, aerial conductivity measurements over geothermal areas, a comparison of multifrequency band radars for crop classification, the improved estimation of vegetation-covered soil by combined active/passive microwave remote sensing, and atmospheric water vapor profiling by ground-based radiometry. Also discussed are SAR imaging from an inclined geosynchronous orbit, the classification of agricultural crops in radar images, the Ocean Color Experiment on the second orbital flight test of the Space Shuttle, the dielectric properties of wet materials, remote sensing systems for the mm-wave region, and the simulation of spaceborne stereo radar imagery.

Seiber, A. J.

Radiometric Calibration of the Earth Observing System's Imaging Sensors

The work on the grant was mainly directed towards developing new, accurate, redundant methods for the in-flight, absolute radiometric calibration of satellite multispectral imaging systems and refining the accuracy of methods already in use. Initially the work was in preparation for the calibration of MODIS and HIRIS (before the development of that sensor was canceled), with the realization it would be applicable to most imaging multi- or hyper-spectral sensors provided their spatial or spectral resolutions were not too coarse. The work on the grant involved three different ground-based, in-flight calibration methods reflectance-based radiance-based and diffuse-to-global irradiance ratio used with the reflectance-based method. This continuing research had the dual advantage of: (1) developing several independent methods to create the redundancy that is essential for the identification and hopefully the elimination of systematic errors; and (2) refining the measurement techniques and algorithms that can be used not only for improving calibration accuracy but also for the reverse process of retrieving ground reflectances from calibrated remote-sensing data. The grant also provided the support necessary for us to embark on other projects such as the ratioing radiometer approach to on-board calibration (this has been further developed by SBRS as the 'solar diffuser stability monitor' and is incorporated into the most important on-board calibration system for MODIS)- another example of the work, which was a spin-off from the grant funding, was a study of solar diffuser materials. Journal citations, titles and abstracts of publications authored by faculty, staff, and students are also attached.

Slater, Philip N.

The Landsat-D responsiveness to user community needs

Initial examinations of the Landsat-4 Multispectral Scanner and Thematic Mapper (IM) imagery indicate that these systems and the ground-based data processing systems are performing well. A combination of the spatial resolution of the multispectral scanner with the four band (0.5-0.6, 0.6-0.7, 0.7-0.8, and 0.8-1.1 microns) multispectral capability provides a useful observation technique for identifying crop type, phenological state of development, and a real condition assessment. Landsat multispectral scanner imagery has become more important in the search for new deposits of oil and mineral resources, and geological applications indicate that image analysis complements geological mapping techniques. Advantages of the TM include more precise measurements of the increased reflectance of vegetation in the green and near infrared. In addition, TM has improvement vegetation species differentiation, due to measurements made in new spectral bands. Preliminary TM data analysis reveals that systems have performed to optimum expectations.

Salomonson, V. V.

In-Flight Edge Response Measurements for High Spatial Resolution Remote Sensing Systems

In-flight measurement of spatial resolution were conducted as part of the ASA Scientific Data Purchase (SDP) Validation and Verification (V&V) process. Characterization included remote sensing systems with ground sample distance (GSD) of 1 meter or less, such as the panchromatic imager on-board the ICONOS satellite and the airborne ADAR System 5500 multispectral instrument. Final image products were used to evaluate the effect of both the image acquisition system (e.g., optics, electronics, motion, jitter, atmosphere) and image post-processing (e.g., resampling, modulation trasfer function (MTF) compensator). Spatial resolution was characterized by full width at half maximum (FWHM) of an edge response-derived line spread function. This was found to be a more robust measure of spatial resolution than the value of NTF at Nyquist frequency The edge responses were analysed using the tilted-edge technique that ovecomes the spatial sampling limitations of the digital imaging systems. As an enhancement to existing algorithms, the slope of the edge response and the orientation of the edge target were determined by a single computational process. Adjacent black and white square panels, either painted on a flat surface or deployed as traps, formed the ground-based edge targets used in the tests. Orientation of the deployable tarps was optimized beforehand, based on simulations of the imaging system. Numerous edge target images were analyzed for each of the tested sensors. The effect of such factors as acquisition geometry, temporal variability, MTF compensation, and GSD on spatial resolution were investigated.

Blonski, Slawomir

NASA IKONOS Multispectral Radiometric Calibration and 3-Year Temporal Stability Assessment

Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can place confidence in the imagery they use and can fully understand its properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other system. In addition, the user community has little or no insight into the design and operation of commercial sensors or into the methods involved in generating commercial products. To address this calibration need, the NASA Stennis Space Center (SSC) Earth Science Applications (ESA) Directorate established a commercial satellite imaging radiometric calibration team consisting of three independent groups: NASA, SSC,ESA, the University of Arizona Remote Sensing Group, and South Dacota State University. Each group determined the absolute radiometric calibration coefficients of the Space Imaging IKONOS 4-band, 4 m multispectral product covering the visible through near-infrared spectral region. For a three year period beginning in 2000, each team employed some variant of a reflectance-based vicarious calibration approach, requiring ground-based measurements coincident with IKONOS image acquisitions and radiative transfer calculations. Several study sites throughout the United States were employed that covered nearly the entire dynamic range of the IKONOS sensor. IKONOS at-sensor radiance values were compared to those estimated by each independent group to determine the IKONOS sensor's radiometric accuracy and stability. Over 10 individual vicariously determined at-sensor radiance estimates were used each year. When combined, these estimates provided a high-precision radiometric gain calibration coefficient. No significant calibration offset was observed. The results of this evaluation provide the scientific community with an independent assessment of the IKONOS sensor's absolute calibration and temporal stability over the 3-year period. While the techniques and method described in this paper reflect those developed at the NASA SSC, the results of the entire team are included.

Pagnutti, Mary

JACIE Radiometric Assessment of QuickBird Multispectral Imagery

Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can place confidence in the imagery they use and can fully understand its properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, the NASA Stennis Space Center (SSC) Earth Science Applications (ESA) directorate,through the Joint Agency for Commercial Imagery Evaluation (JACIE) framework, established a commercial imaging satellite radiometric calibration team consisting of two groups: 1) NASA SSC ESA, supported by South Dakota State University, and 2) the University of Arizona Remote Sensing Group. The two groups determined the absolute radiometric calibration coefficients of the Digital Globe 4-band, 2.4-m QuickBird multispectral product covering the visible through near-infrared spectral region. For a 2-year period beginning in 2002, both groups employed some variant of a reflectance-based vicarious calibration approach, which required ground-based measurements coincident with QuickBird image acquisitions and radiative transfer calculations. The groups chose several study sites throughout the United States that covered nearly the entire dynamic range of the QuickBird sensor. QuickBird at-sensor radiance values were compared with those estimated by the two independent groups to determine the QuickBird sensor's radiometric accuracy. Approximately 20 at-sensor radiance estimates were vicariously determined each year. The estimates were combined to provide a high-precision radiometric gain calibration coefficient. The results of this evaluation provide the user community with an independent assessment of the QuickBird sensor's absolute calibration and stability over the 2-year period. While the techniques and method described reflect those developed at the NASA SSC, the results of both JACIE team groups are included in this paper.

Pagnutti, Mary

Radiometric Characterization Results for the IKONOS, Quickbird, and OrbView-3 Sensor

Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities better understand commercial imaging satellite properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, the NASA Applied Sciences Directorate (ASD) at Stennis Space Center established a commercial satellite imaging radiometric calibration team consisting of three independent groups: NASA ASD, the University of Arizona Remote Sensing Group, and South Dakota State University. Each group independently determined the absolute radiometric calibration coefficients of available high-spatial-resolution commercial 4-band multispectral products, in the visible though near-infrared spectrum, from GeoEye(tradeMark) (formerly SpaceImaging(Registered TradeMark)) IKONOS, DigitalGlobe(Regitered TradeMark) QuickBird, and GeoEye (formerly ORBIMAGE(Registered TradeMark) OrbView. Each team member employed some variant of reflectance-based vicarious calibration approach, requiring ground-based measurements coincident with image acquisitions and radiative transfer calculations. Several study sites throughout the United States that covered a significant portion of the sensor's dynamic range were employed. Satellite at-sensor radiance values were compared to those estimated by each independent team member to evaluate the sensor's radiometric accuracy. The combined results of this evaluation provide the user community with an independent assessment of these sensors' absolute calibration values.

Holekamp, Kara