Search NASA⌕ Search

SEARCH · Search NASA

Results for “national synchrotron light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Refurbishment of a used in-vacuum undulator from the National Synchrotron Light Source for the National Synchrotron Light Source-II ring

The National Synchrotron Light Source (NSLS) ceased operation in September 2014 and was succeeded by NSLS-II. There were four in-vacuum undulators (IVUs) in operation at NSLS. The most recently constructed IVU for NSLS was the mini-gap undulator (MGU-X25, to be renamed IVU18 for NSLS-II), which was constructed in 2006. This device was selected to be reused for the New York Structural Biology Consortium Microdiffraction beamline at NSLS-II. At the time of construction, IVU18 was a state-of-the-art undulator designed to be operated as a cryogenic permanent-magnet undulator. Due to the more stringent field quality and impedance requirements of the NSLS-II ring, the transition region was redesigned. The control system was also updated to NSLS-II specifications. As a result, this paper reports the details of the IVU18 refurbishment activities including additional magnetic measurement and tuning.

36 MATERIALS SCIENCE↗

National Synchrotron Light Source II storage ring vacuum systems

The National Synchrotron Light Source II, completed in 2014, is a 3-GeV synchrotron radiation (SR) facility at Brookhaven National Laboratory and has been in steady operation since. With a design electron current of 500 mA and subnanometer radians horizontal emittance, this 792-m circumference storage ring is providing the highest flux and brightness x-ray beam for SR users. The majority of the storage ring vacuum chambers are made of extruded aluminium. Chamber sections are interconnected using low-impedance radiofrequency shielded bellows. SR from the bending magnets is intercepted by water-cooled compact photon absorbers resided in the storage ring chambers. This paper presents the design of the storage ring vacuum system, the fabrication of vacuum chambers and other hardware, the installation, the commissioning, and the continuing beam conditioning of the vacuum systems.

43 PARTICLE ACCELERATORS↗

High Pressure Research at the National Synchrotron Light Source

The National Synchrotron Light Source at Brookhaven National Laboratory has been home to a successful high-pressure program for over 20 years. The first dedicated high-pressure diffraction endstation, X17C, was etablished at NSLS in 1990. A large number of new techniques have been developed at this beamline, including double-sided laser heating, single crystal diffraction above 60 GPa, x-ray diffraction measurements in a resistive heated diamond anvil cell (DAC) at 1300 K and 1 megabar, the first high-pressure and low-temperature experiment, and radial diffraction in a DAC.

43 PARTICLE ACCELERATORS↗

Induced Radioactivity in Lead Shielding at the National Synchrotron Light Source

The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory was shut down in September 2014. Lead bricks used as radiological shadow shielding within the accelerator were exposed to stray radiation fields during normal operations. The FLUKA code, a fully integrated Monte Carlo simulation package for the interaction and transport of particles and nuclei in matter, was used to estimate induced radioactivity in this shielding and stainless steel beam pipe from known beam losses. The FLUKA output was processed using MICROSHIELD® to estimate on-contact exposure rates with individually exposed bricks to help design and optimize the radiological survey process. This entire process can be modeled using FLUKA, but use of MICROSHIELD® as a secondary method was chosen because of the project’s resource constraints. Due to the compressed schedule and lack of shielding configuration data, simple FLUKA models were developed in this paper. FLUKA activity estimates for stainless steel were compared with sampling data to validate results, which show that simple FLUKA models and irradiation geometries can be used to predict radioactivity inventories accurately in exposed materials. During decommissioning 0.1% of the lead bricks were found to have measurable levels of induced radioactivity. Finally, post-processing with MICROSHIELD® provides an acceptable secondary method of estimating residual exposure rates.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Low-Level Radio Frequency System Development for the National Synchrotron Light Source II

The National Synchrotron Light Source-II (NSLS-II) is a new ultra-bright 3GeV 3rd generation synchrotron radiation light source. The performance goals require operation with a beam current of 500mA and a bunch current of at least 0.5mA. The position and timing specifications of the ultra-bright photon beam imposes a set of stringent requirements on the performance of radio frequency (RF) control. In addition, commissioning and staged installation of damping wigglers and insertion devices requires the flexibility of handling varying beam conditions. To meet these requirements, a digital implementation of the LLRF is chosen, and digital serial links are planned for the system integration. The first prototype of the controller front-end hardware has been built, and is currently being tested.

43 PARTICLE ACCELERATORS↗

National Synchrotron Light Source 2010 Activity Report

This is a very exciting period for photon sciences at Brookhaven National Laboratory. It is also a time of unprecedented growth for the Photon Sciences Directorate, which operates the National Synchrotron Light Source (NSLS) and is constructing NSLS-II, both funded by the Department of Energy's Office of Science. Reflecting the quick pace of our activities, we chose the theme 'Discovery at Light Speed' for the directorate's 2010 annual report, a fiscal year bookended by October 2009 and September 2010. The year began with the news that NSLS users Venki Ramakrishnan of Cambridge University (also a former employee in Brookhaven's biology department) and Thomas A. Steitz of Yale University were sharing the 2009 Nobel Prize in Chemistry with Ada E. Yonath of the Weizmann Institute of Science. Every research project has the potential for accolades. In 2010, NSLS users and staff published close to 900 papers, with about 170 appearing in premiere journals. Those are impressive stats for a facility nearly three decades old, testament to the highly dedicated team keeping NSLS at peak performance and the high quality of its user community. Our NSLS users come from a worldwide community of scientists using photons, or light, to carry out research in energy and environmental sciences, physics, materials science, chemistry, biology and medicine. All are looking forward to the new capabilities enabled by NSLS-II, which will offer unprecedented resolution at the nanoscale. The new facility will produce x-rays more than 10,000 times brighter than the current NSLS and host a suite of sophisticated instruments for cutting-edge science. Some of the scientific discoveries we anticipate at NSLS-II will lead to major advances in alternative energy technologies, such as hydrogen and solar. These discoveries could pave the way to: (1) catalysts that split water with sunlight for hydrogen production; (2) materials that can reversibly store large quantities of electricity or hydrogen; (3) high-temperature superconducting materials that carry electricity with no loss for efficient power transmission lines; and (4) materials for solid-state lighting with half of the present power consumption. Excitement about NSLS-II is evident in many ways, most notably the extraordinary response we had to the 2010 call for beamline development proposals for the anticipated 60 or more beamlines that NSLS-II will ultimately host. A total of 54 proposals were submitted and, after extensive review, 34 were approved. Funding from both the Department of Energy and the National Institutes of Health has already been secured to support the design and construction of a number of these beamlines. FY11 is a challenging and exciting year for the NSLS-II Project as we reach the peak of our construction activity. We remain on track to complete the project by March 2014, a full 15 months ahead of schedule and with even more capabilities than originally planned. The Photon Sciences Directorate is well on its way to fulfilling our vision of being a provider of choice for world-class photon sciences and facilities.

43 PARTICLE ACCELERATORS↗

NSLS 2007 Activity Report (National Synchrotron Light Source Activity Report 2007)

The National Synchrotron Light Source is one of the world's most productive and cost-effective user facilities. With 2,219 individual users, about 100 more than last year, and a record-high 985 publications, 2007 was no exception. In addition to producing an impressive array of science highlights, which are included in this Activity Report, many NSLS users were honored this year for their scientific accomplishments. Throughout the year, there were major strides in the development of the scientific programs by strengthening strategic partnerships with major research resources and with the Center for Functional Nanomaterials (CFN). Of particular note, the Consortium for Materials Properties Research in Earth Sciences (COMPRES) received renewed funding for the next five years through the National Science Foundation. COMPRES operates four high-pressure NSLS beamlines--X17B2, X17B3, X17C, and U2A--and serves the earth science community as well as the rapidly expanding segment of researchers using high-pressure techniques in materials, chemical, and energy-related sciences. A joint appointment was made between the NSLS and Stony Brook University to further enhance interactions with COMPRES. There was major progress on two key beamline projects outlined in the Five-Year Strategic Plan: the X25 beamline upgrade and the construction of the X9 small angle scattering (SAXS) beamline. The X25 overhaul, which began with the installation of the in-vacuum mini-gap undulator (MGU) in January 2006, is now complete. X25 is once again the brightest beamline for macromolecular crystallography at the NSLS, and in tandem with the X29 undulator beamline, it will keep the NSLS at the cutting edge in this important area of research. Upgrade work associated with the new MGU and the front end for the X9 SAXS beamline--jointly developed by the NSLS and the CFN--also was completed. Beamline X9 will host the SAXS program that currently exists at beamline X21 and will provide new microbeam SAXS capabilities and much-needed beam time for the life sciences, soft condensed matter physics, and nanoscience communities. Looking toward the future, a significant step has been made in expanding the user base and diversifying the work force by holding the first Historically Black Colleges and Universities (HBCU) Professors' Workshop. The workshop, which brought 11 professors to the NSLS to learn how to become successful synchrotron users, concluded with the formation of an HBCU User Consortium. Finally, significant contributions were made in optics and detector development to enhance the utilization of the NSLS and address the challenges of NSLS-II. In particular, x-ray detectors developed by the NSLS Detector Section have been adopted by an increasing number of research programs both at the NSLS and at light sources around the world, speeding up measurement times by orders of magnitude and making completely new experiments feasible. Significant advances in focusing and high-energy resolution optics have also been made this year.

43 PARTICLE ACCELERATORS↗

Structural biology at the National Synchrotron Light Source II

The structural biology program at the National Synchrotron Light Source II presents a coordinated set of instruments, software and research opportunities for the interested user. We describe in some detail the research capabilities enabled by the Center for BioMolecular Structure. The evolution of the resources is described in detail, considering three major themes: automation, micro-focusing and computation prediction.

36 MATERIALS SCIENCE↗

The electron spectro-microscopy beamline at National Synchrotron Light Source II: A wide photon energy range, micro-focusing beamline for photoelectron spectro-microscopies

A comprehensive optical design for a high-resolution, high-flux, wide-energy range, micro-focused beamline working in the vacuum ultraviolet and soft x-ray photon energy range is proposed. The beamline is to provide monochromatic radiation to three photoelectron microscopes: a full-field x-ray photoelectron emission microscope and two scanning instruments, one dedicated to angle resolved photoemission spectroscopy ({mu}-ARPES) and one for ambient pressure x-ray photoelectron spectroscopy and scanning photoelectron microscopy (AP-XPS/SPEM). Microfocusing is achieved with state of the art elliptical cylinders, obtaining a spot size of 1 {mu}m for ARPES and 0.5 {mu}m for AP-XPS/SPEM. A detailed ray tracing analysis quantitatively evaluates the overall beamline performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National Synchrotron Light Source

A tour of Brookhaven's National Synchrotron Light Source (NSLS). The NSLS is one of the world's most widely used scientific research facilities, hosting more than 2,500 guest researchers each year. The NSLS provides intense beams of infrared, ultraviole

47 OTHER INSTRUMENTATION↗

National Synchrotron Light Source (NSLS) 2009 Activity Report

2009 was an incredibly exciting year for light sources at Brookhaven. The National Synchrotron Light Source (NSLS) hosted more than 2,200 visiting researchers, who, along with the about 50 members of our scientific staff, produced a total of 957 publications - about 20 percent of which appeared in premier journals. Covering topics ranging from Alzheimer's disease detection to ethanol-powered fuel cells, a sampling of these findings can be found in this Activity Report. We've also seen the resurfacing of some of our long-time users hard work. I was very proud to hear that two of the three recipients of the 2009 Nobel Prize in Chemistry have ties to the NSLS. Venki Ramakrishnan, a former employee in Brookhaven's biology department and long-time user of the NSLS, now at Cambridge University, and Thomas A. Steitz of Yale University, also a long-time NSLS user, shared the prize with Ada E. Yonath of the Weizmann Institute of Science for their work on the structure and function of the ribosome. In the late 1990s, Ramakrishnan and Steitz used protein crystallography at the NSLS to gather atomic-level images of two ribosome subunits: 30S (Ramakrishnan) and 50S (Steitz). Both laureates solved the high-resolution structures for these subunits based on this data. After struggling with a rough budget for several years, we received excellent funding, and then some, this year. In addition to NSLS operations funding, we received 3 million USD in funds from the American Recovery and Reinvestment Act (ARRA). We used that additional money for two exciting projects: construction of a full-field x-ray microscope and acquisition of several advanced x-ray detectors. The x-ray microscope will be able to image objects with a targeted spatial resolution of 30 nanometers. This capability will be particularly important for new initiatives in energy research and will prepare our users for the projected 1-nanometer resolution benchmark at the National Synchrotron Light Source II (NSLS-II). The detectors project is expected to increase the throughput of several high-demand beamlines by an order of magnitude as well as enable new classes of experiments. In addition, a huge chunk of ARRA money - 150 million USD - was put toward accelerating the construction of NSLS-II, which is now taking shape across the street. Now physically much more than just a pile of dirt, NSLS-II was granted Critical Decision 3 status by the Department of Energy (DOE) early last year, giving the official go-ahead for construction. In July, construction began, marked by a groundbreaking ceremony that attracted elected officials, media, and DOE, Battelle, and Stony Brook University representatives from across the state and the country. As progress on NSLS-II continues, we're working with Stony Brook University to identify ways to capitalize on the facility's unique capabilities through the Joint Photon Sciences Institute (JPSI). Included in this effort is a series of workshops to encourage the development and application of the photon sciences with collaborative research between industries, universities, and national laboratories. We helped host three of these workshops this year, focusing on microelectronics, energy storage, and materials in next-generation energy systems. The conversation and ideas generated at these meetings has been fresh and valuable and we hope to use this model to organize research opportunities in other scientific fields. Also this year: Brookhaven was deemed the lead institution for one of DOE's 46 Energy Frontier Research Centers, focused on understanding the underlying nature of superconductivity in complex materials by using techniques at the NSLS and CFN; DOE awarded a 100,000 USD supplemental grant to our detector program to continue the development of a new generation of x-ray detectors that use germanium sensors, which, at high energies, are much more efficient than equivalent ones based on silicon; and funding for one of our largest consortia, Case Western Reserve University's Center for Synchrotron Biosciences (CSB), was renewed through the National Institutes of Health. The CSB, which operates five NSLS beamlines and serves more than 550 users, will receive a five-year, 4-million USD grant to continue to study the structure and dynamics of proteins and nucleic acids. Finally, construction of the new X9 beamline and endstation for small angle x-ray scattering (SAXS) and wide angle x-ray scattering (WAXS) was completed this year. By July, the beamline and endstation were commissioned and serving general users. This allowed for the relocation of the SAXS and WAXS experimental programs from beamline X21 to X9, providing much-needed beam time for the soft condensed matter physics, life sciences, and nanoscience communities.

30 DIRECT ENERGY CONVERSION↗

FMX – the Frontier Microfocusing Macromolecular Crystallography Beamline at the National Synchrotron Light Source II

Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425 , 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493 , 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015 , 1741 , 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5–30 keV photon energy range and delivers a flux of 4.0 × 10 12 photons s −1 at 1 Å into a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 10 12 photons s −1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods – serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25 , 1362–1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ , 5 , 238–246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5 , 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sextupole reduction via chaos suppression at the National Synchrotron Light Source II

We revisit the nonlinear lattice design approach for the National Synchrotron Light Source II (NSLS-II) storage ring. By suppressing chaos, we identify alternative sextupole configurations to the original design, which relied on the conventional strategy of simultaneously minimizing resonance driving terms (RDTs) and amplitude-dependent detuning (ADD). These alternatives achieve comparable performance while requiring fewer sextupoles. A detailed comparison of two representative solutions is presented and supported by experimental validation. Our results show that the dynamic aperture correlates more strongly with global chaos than with individual RDTs, and that the importance of minimizing ADD may have been overstated in earlier design strategies.

36 MATERIALS SCIENCE↗

THE Low-level Radio Frequency System for the superconducting cavities of National Synchrotron Light Source II

A digital low-level radio frequency (LLRF) field controller has been developed for the storage ring of The National Synchrotron Light Source-II (NSLS-II). The primary performance goal for the LLRF is to support the required RF operation of the superconducting cavities with a beam current of 500mA and a 0.14 degree or better RF phase stability. The digital field controller is FPGA-based, in a standard format 19-inch/I-U chassis. It has an option of high-level control support with MATLAB running on a local host computer through a USB2.0 port. The field controller has been field tested with the high-power superconducting RF (SRF) at Canadian light Source, and successfully stored a high beam current of 250 mA. The test results show that required specifications for the cavity RF field stability are met. This digital field controller is also currently being used as a development platform for other functional modules in the NSLS-II RF systems.

43 PARTICLE ACCELERATORS↗

Environmental Remediation Science at Beamline X26A at the National Synchrotron Light Source- Final Report

The goal of this project was to provide support for an advanced X-ray microspectroscopy facility at the National Synchrotron Light Source, Brookhaven National Laboratory. This facility is operated by the University of Chicago and the University of Kentucky. The facility is available to researchers at both institutions as well as researchers around the globe through the general user program. This facility was successfully supported during the project period. It provided access to advanced X-ray microanalysis techniques which lead to fundamental advances in understanding the behavior of contaminants and geochemistry that is applicable to environmental remediation of DOE legacy sites as well as contaminated sites around the United States and beyond.

54 ENVIRONMENTAL SCIENCES↗

National Synchrotron Light Source 2008 Activity Report

Funded by the U.S. Department of Energy's Office of Basic Energy Sciences, the National Synchrotron Light Source (NSLS) is a national user facility that operates two electron storage rings: X-Ray (2.8 GeV, 300 mA) and Vacuum Ultraviolet (VUV) (800 mev, 1.0A). These two rings provide intense light spanning the electromagnetic spectrum -- from very long infrared rays to ultraviolet light and super-short x-rays -- to analyze very small or highly dilute samples. The properties of this light, and the specially designed experimental stations, called beamlines, allow scientists in many diverse disciplines of research to perform experiments not possible at their own laboratories. Each year, about 2,200 scientists from more than 400 universities and companies use the NSLS for research in such diverse fields as biology, physics, chemistry, geology, medicine, and environmental and materials sciences. For example, researchers have used the NSLS to examine the minute details of computer chips, decipher the structures of viruses, probe the density of bone, determine the chemical composition of moon rocks, and reveal countless other mysteries of science. The facility has 65 operating beamlines, with 51 beamlines on the X-Ray Ring and 14 beamlines on the VUV-Infrared Ring. It runs seven days a week, 24 hours a day throughout the year, except during periods of maintenance and studies. Researchers are not charged for beam time, provided that the research results are published in open literature. Proprietary research is conducted on a full-cost-recovery basis. With close to 1,000 publications per year, the NSLS is one of the most prolific scientific facilities in the world. Among the many accolades given to its users and staff, the NSLS has won nine R&D 100 Awards for innovations ranging from a closed orbit feedback system to the first device able to focus a large spread of high-energy x-rays. In addition, a visiting NSLS researcher shared the 2003 Nobel Prize in Chemistry for work explaining how one class of proteins helps to generate nerve impulses.

43 PARTICLE ACCELERATORS↗

Dynamic Monitoring of Grating Angle at the National Synchrotron Light Source

We present a dynamic monitoring method and monitoring system of grating angle, referred to as the Precise Angle Monitor (PAM), at U4B, a soft x-ray spherical grating monochromator (SGM) beam line at the National Synchrotron Light Source (NSLS). In an SGM, a photon energy scan is accomplished by rotating the grating angle precisely. After several decades of service, the monochromator at U4B developed instabilities that severely impacted the experimental program. Over several hours, either the spectral shape experienced distortions or the spectral peak shifted. In order to directly monitor the grating motion during scans, the optical head of a portable long trace profiler (PTLTP) was installed on U4B as the PAM. We find that the grating rotational motion is not ideal: (1) the scan steps are not smooth and there are high-frequency step angle errors; (2) there is also a low-frequency angle error; and (3) an unstable thermal expansion produces extra rotational error. Measurements of dynamic monitoring are presented, including grating rotation repeatability and thermal instability. The results illustrate the utility of dynamic monitoring of monochromator motion during actual operation.

43 PARTICLE ACCELERATORS↗

Multimodal, Multidimensional, and Multiscale X-ray Imaging at the National Synchrotron Light Source II

Over the last couple of decades, the synchrotron radiation research community has witnessed tremendous advancement in the field of x-ray imaging and microscopy. Continuing enhancement of the light sources’ brightness, advances in x-ray focusing optics, incorporation of precision instruments, and development of innovative imaging techniques are some of the leading contributors for the rapid progress. New imaging and microscopy beamlines, such as the ones at the National Synchrotron Light Source II (NSLS-II), a Department of Energy (DOE) Office of Science user facility located at DOE’s Brookhaven National Laboratory, are capable of performing more sophisticated and complicated measurements than ever before, either on their own or used together as a suite of tools. These sophisticated and complex measurements exhibit attributes for multimodal, multidimensional, and multiscale imaging. Recent popularity of these methods is strongly driven by the current trends in materials characterizations, where researchers desire to map out hierarchical materials structure over a large range of length scales, to understand structure-property correlation, to quantify materials structures in 3D, and/or to perform operando or in situ experiments. It is important to emphasize that “materials” under investigation are not only synthesized materials but also the natural materials. In this article, we describe multimodal, multidimensional and multiscale x-ray imaging capabilities of the NSLS-II beamlines and how these methods are used to tackle complex scientific problems.

47 OTHER INSTRUMENTATION↗