Search NASA⌕ Search

SEARCH · Search NASA

Results for “net zero codes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Paving the Way for Net Zero Energy Codes through Performance Based Approaches

The prescriptive path is the most widely used approach for commercial code compliance in the United States. However, to achieve near-term net zero energy performance that many stakeholders in the buildings industry desire, it is clear that energy codes will need to transition from prescriptive to performance-based approaches. However, that transition is not without potential pitfalls. Among the concerns expressed by stakeholders are added complexity and cost, lack of confidence in energy modeling results, gamesmanship on the part of applicants, lack or qualified reviewers, challenges in promoting de-carbonization, and the inequity of trading long lived envelope efficiency for short lived measures such as building controls. This paper will discuss multiple approaches being evaluated and implemented by Pacific Northwest National Laboratory to improve the usability of the performance-based approach for both code compliance and beyond code programs to meet aggressive energy savings targets. A 'system performance' approach provides a simpler approach compared to whole building performance, while keeping tradeoffs limited to specific building systems. A simplified whole-building performance-based approach for small commercial buildings can cost effectively achieve deeper savings for buildings that typically follow the prescriptive compliance approach. Improved reporting and verification processes applied to the traditional performance path can provide greater confidence in simulation results and facilitate adoption of performance-based approaches. Prescriptive packages provide prescriptive solutions while targeting specific performance thresholds. This paper discusses the progress being made with each of these approaches and provides examples of their implementation in energy codes and beyond code programs.

Performance Based Codes, Appendix G, PRM, TSPR, Sy↗

Colorado Better Buildings Project. Final Report

The Colorado Better Buildings project intended to bring new and existing energy efficiency model programs to market with regional collaboration and funding partnerships. The goals for Boulder County and its program partners were to advance energy efficiency investments, stimulate economic growth in Colorado and advance the state’s energy independence. Collectively, three counties set out to complete 9,025 energy efficiency upgrades in 2.5 years and they succeeded in doing so. Energy efficiency upgrades have been completed in more than 11,000 homes and businesses in these communities. Boulder County and its partners received a $25 million BetterBuildings grant from the U.S. Department of Energy under the American Recovery and Reinvestment Act in the summer of 2010. This was also known as the Energy Efficiency and Conservation Block Grants program. With this funding, Boulder County, the City and County of Denver, and Garfield County set out to design programs for the residential and commercial sectors to overcome key barriers in the energy upgrade process. Since January 2011, these communities have paired homeowners and business owners with an Energy Advisor – an expert to help move from assessment to upgrade with minimal hassle. Pairing this step-by-step assistance with financing incentives has effectively addressed many key barriers, resulting in energy efficiency improvements and happy customers. An expert energy advisor guides the building owner through every step of the process, coordinating the energy assessment, interpreting results for a customized action plan, providing a list of contractors, and finding and applying for all available rebates and low-interest loans. In addition to the expert advising and financial incentives, the programs also included elements of social marketing, technical assistance, workforce development and contractor trainings, project monitoring and verification, and a cloud-based customer data system to coordinate among field advisors and across local governments and local service vendors. A portion of the BetterBuildings grant went to the Metro Mayors Caucus (MMC) who worked in partnership with the Denver Regional Council of Governments (DRCOG) to conduct a series of 10 energy efficiency workshops for local government officials and other interested parties. The workshops helped showcase lessons learned on energy efficiency and helped guide other local governments in the establishment of similar programs. The workshops covered a wide range of energy efficiency and renewable energy topics such as clean energy finance, social mobilization and communications, specific case studies of Colorado towns, energy efficiency codes, net zero buildings and solar power. Since the programs launched in January 2011, these communities have collectively spurred economic investments in energy efficiency, achieved greater than 5:1 leveraging of grant funds, saved energy and reduced greenhouse gas emissions, provided trainings for a robust local energy contractor network, and proved out viable and replicable program models that local utilities and other communities are adopting, with long lasting market transformation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition. To support the effort, PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code (2018) in New York. The focus of this project is the 20% improvement over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate 20% energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New York. Section 2 of this report describes the analysis methodology, including the building types and construction area weights update for this analysis, the baseline, and the method to conduct the energy saving analysis. Section 3 provides detailed specifications of the EEMs and bundles. Section 4 summarizes the results of individual EEMs and EEM bundles by building type, energy end-use and climate zone. Appendix A documents detailed descriptions of the selected prototype buildings. Appendix B provides energy end-use breakdown results by building type for both the baseline code and stretch code in all climate zones.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition (NYSERDA 2018). To support the effort, PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 in New York. The focus of this project is to significantly improve the energy efficiency over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate significant energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New York.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

In 2017, New York State Energy Research and Development Authority (NYSERDA) developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code. Since2017, NYSERDA has continued to develop the 2018 edition, as part of the efforts to achieve a statewide Net Zero Energy Code by 2028. To support this effort, Pacific Northwest National Laboratory (PNNL)conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 compared to ANSI/ASHRAE/IES1 Standard 90.1-2013. Specifically, PNNL collaborated with New Buildings Institute (NBI), and developed energy-efficiency measures (EEMs) from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the ongoing NYStretch-Energy code development process. PNNL analyzed these measures using whole building energy simulation for selected prototype commercial and multifamily buildings representing buildings in New York State.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

In 2017, New York State Energy Research and Development Authority (NYSERDA) developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code. Since 2017, NYSERDA has continued to develop the 2018 edition, as part of the efforts to achieve a statewide Net Zero Energy Code by 2028. To support this effort, Pacific Northwest National Laboratory (PNNL) conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 compared to ANSI/ASHRAE/IES1 Standard 90.1-2013. Specifically, PNNL collaborated with New Buildings Institute (NBI), and developed energy-efficiency measures (EEMs) from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the ongoing NYStretch-Energy code development process. PNNL analyzed these measures using whole building energy simulation for selected prototype commercial and multifamily buildings representing buildings in New York State. This report describes the analysis methodology, explains detailed specifications of the EEMs, and summarizes the results of individual EEMs and EEM bundles by building type and climate zone. As shown in Figure ES.1, significant energy saving could be achieved by adopting the NYStretch-Energy Code 2018.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Total System Performance Ratio—A Systems Based Approach for Evaluating HVAC System Efficiency

The prescriptive path is the most widely used approach for commercial code compliance in the United States. Though easy to implement, prescriptive approaches do not typically discriminate between minimally compliant, high-performing and poorly performing HVAC system configurations. Hence, to meet aggressive energy and carbon reduction goals, it is clear that energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. This paper discusses a new HVAC system-based performance approach (HVAC System Performance) which provides a simpler solution to HVAV system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution which could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A calculation software tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach is also being evaluated by ASHRAE Standard 90.l Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

What, why and when to go virtual: An international analysis of early adopters of virtual building energy codes inspections

To meet greenhouse gas reduction targets, several countries are pursuing more ambitious policies in their buildings and construction sectors, such as introducing zero net energy/carbon building codes. Countries often report not having enough qualified staff for performing building energy code inspections and many are exploring faster, easier, and more reliable methods to check the compliance of buildings with their codes. Building inspections are a critical element for ensuring code compliance and they have traditionally been performed in person. However, in-person inspections can be labor and travel intensive, costly, and prone to human error. In this paper, the authors explore how virtual inspections, particularly in light of the recent COVID-19 pandemic, have impacted processes for building code compliance checks in jurisdictions and communities around the world. Here, the authors collected data on four key parameters (time and financial savings, scope of inspections, changing practices and technological innovation, and benefits to consumers) from six jurisdictions and communities in five countries (Australia, Canada, Singapore, United Arab Emirates, and the United States) to analyze the impacts of virtual inspections on code compliance checks. The analysis found the greatest value from virtual inspections in geographically dispersed regions and for cities experiencing rapid building construction. The study also explored emerging technologies that are being piloted for virtual inspections. Although many of these technologies hold promise, more resources and capacity are needed to make them viable for use in building energy code inspections.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Market Driven Residential Energy Codes: Comparing Performance in a Changing Technological Environment

The research project is undertaken to better understand the changing relationship between the two basic methods of building energy code compliance – prescriptive and performance – and how those methods relate to each other with respect to advancements in building energy computer simulation standards and capabilities. The International Energy Efficiency Code (IECC) is a model code adopted by many jurisdictions across the United States. Historically, the prescriptive compliance methodology has been preferred in most jurisdictions. The prescriptive methodology requires meeting or exceeding specific efficiency minimums for each envelope component. This tends to be a simple method to teach and verify. A more involved prescriptive alternative called the Total UA alternative is sometimes used. This method requires some multiplication, summing, and comparison to compute, so it is done with a fairly simple computer program. However, advances in computer and building energy simulation technology have resulted in increased use of more detailed performance compliance methods. The performance compliance method establishes the annual energy cost threshold via hourly simulation models. The compliance threshold is determined with a comparison building model simulation with geometry similar to the proposed home and with energy feature parameters and efficiencies as specified in the IECC. This project examines relationships between the two methods of building energy code compliance, including: • Overall annual energy use based on utility bill analysis by compliance method • Code official work processes with respect to compliance methods • Gaps and issues associated with building code compliance methods • Simulated energy use difference between compliance methods • Code compliance cost as a function of compliance method • Code compliance labeling effectiveness for high performance residences • Getting to net zero energy use and net zero greenhouse gas emissions through high performance code alternatives • Electronic code permitting and compliance alternatives

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

VISCOUS AND RESISTIVE EFFECTS ON THE MAGNETOROTATIONAL INSTABILITY WITH A NET TOROIDAL FIELD

Resistivity and viscosity have a significant role in establishing the energy levels in turbulence driven by the magnetorotational instability (MRI) in local astrophysical disk models. This study uses the Athena code to characterize the effects of a constant shear viscosity nu and Ohmic resistivity eta in unstratified shearing box simulations with a net toroidal magnetic flux. A previous study of shearing boxes with zero net magnetic field performed with the ZEUS code found that turbulence dies out for values of the magnetic Prandtl number, P {sub m} = nu/eta, below P {sub m} approx 1; for P {sub m} approx> 1, time- and volume-averaged stress levels increase with P {sub m}. We repeat these experiments with Athena and obtain consistent results. Next, the influence of viscosity and resistivity on the toroidal field MRI is investigated both for linear growth and for fully developed turbulence. In the linear regime, a sufficiently large nu or eta can prevent MRI growth; P {sub m} itself has little direct influence on growth from linear perturbations. By applying a range of values for nu and eta to an initial state consisting of fully developed turbulence in the presence of a background toroidal field, we investigate their effects in the fully nonlinear system. Here, increased viscosity enhances the turbulence, and the turbulence decays only if the resistivity is above a critical value; turbulence can be sustained even when P {sub m} < 1, in contrast to the zero net field model. While we find preliminary evidence that the stress converges to a small range of values when nu and eta become small enough, the influence of dissipation terms on MRI-driven turbulence for relatively large eta and nu is significant, independent of field geometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Review of the U.S. Policies, Codes, and Standards of Zero-Carbon Buildings

The global issue of climate change has accelerated the international commitment to net-zero carbon emission development. Decarbonizing the building sector has been put on several governments’ sustainable development agendas. To provide a reference for decarbonizing the building sector, this paper summarizes the U.S. experience in zero-carbon buildings (ZCBs) from the aspects of policies, codes, and standards at the federal and local levels and those of professional societies. Based on the definition and boundaries of ZCBs, this paper introduces policies on building energy efficiency, electrification, on-site renewable energy deployment, and “buy clean”, illustrating highlights in building phases, energy systems, materials production, and fiscal incentives. The synergic efforts and coordination between federal and local levels and with professional societies are also introduced. Successful experiences in policy and standard implementation are summarized, including the systemic work of multilevel governance, clearly defined goals and stringent policies, constant upgrades of codes and standards, transparency in reporting and information sharing, and increased financial and investment opportunities. This paper provides concrete recommendations for developing zero-carbon building policies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Zero Code Plug-In: Zero Energy and Operational Emissions Overlay for Model Energy Codes (Technical Brief)

Model energy codes (MEC) describe requirements needed to demonstrate building energy performance compliance. They can be readily adopted by states and local jurisdictions to support desirable energy efficiency investment in new buildings and major renovations. This report provides commercial building energy code language as an overlay to current MEC, which is recognized by the U.S. DOE as ASHRAE Standard 90.1 2022. The code language provides a performance-based compliance path for achieving net zero energy or net zero operational energy emissions buildings with MEC. The path requires meeting two compliance metric target values: 1) a required minimum level of efficiency and 2) a measure of zero energy or emissions. The supporting documentation illustrates the magnitude of needed efficiency improvement and the additional offsets to be achieved from renewable energy sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model Energy Codes End-Use Opportunity Analysis

Model energy codes (ASHRAE Standard 90.1 and IECC) has significantly impacted programs and policies aimed at improving energy efficiency both in United States and across the globe. Standard 90.1, first published in 1975 (originally referred to as Standard 90) provides minimum energy efficiency guidelines for designing, constructing, operating, and maintaining new construction and renovated buildings. It is updated continuously, with new editions published every 3 years. Pacific Northwest National Laboratory (PNNL) conducts simulated energy and cost savings analysis of model energy codes to determine their expected impact and to track progress toward net-zero goals and efficiency targets. Additionally, the simulation outputs are examined to assess how energy is used across primary systems within prominent U.S. commercial building types to understand how energy is used in each building type at the end-use level and to identify areas for improvements in future code cycles. This end-use opportunity analysis of model energy codes provides ASHRAE technical committees and other interested parties a better understanding of how the Standard affects various building systems and end uses, specifically, those in the Standard that most prominently influence energy efficiency. Additionally, findings provide industry stakeholders guidance in identifying building types and end-uses with the most potential for energy efficiency improvements through energy codes and those that may require beyond code measures to meet energy use reduction targets. This paper summarizes features and functionalities of a webtool created by PNNL to explore and visualize the End-Use opportunity analysis.

ASHRAE 90.1, Energy Codes, Tableau↗

Effective Kitchen Ventilation for Healthy Zero Net Energy Homes with Natural Gas

Past studies indicate that kitchen ventilation that minimally complies with California’s Residential Building Code is inadequate at controlling combustion pollutants from natural gas burners and particulate matter produced during cooking. Effectiveness is further limited by misperceptions that kitchen ventilation is infrequently needed. This project developed the technical basis for updating kitchen ventilation requirements to protect health in new California homes, especially in smaller homes common among low-income renters. Tasks included (1) a field study of ventilation equipment performance and indoor air quality in 23 low-income apartments at four sites; (2) analysis of range hood use related to cooking time and household parameters using data from 54 houses and 17 low-income apartments; (3)a measurement-based study to quantify performance of over-the-range microwave ovens with integrated exhaust fans;and (4) pollutant exposure simulations to inform capture efficiency standards.The field study found operational deficiencies with mechanical ventilation systems in a substantial fraction of low-income apartments that affected performance, resulting in higher exposures to pollutants generated indoors. Using gas cooking burners produced high short-term and weekly time-averaged nitrogen dioxide in apartments.Range hoods were used more frequently with cooking in houses (36percent) than apartments (28percent); use increased with overall cooking frequency in a home and with duration of cooktop but not oven events; actual use was correlated to, but lower than,self-reported use;and use was more frequent in houses when cooking generated any fine particulate matter (PM2.5)or when high PM2.5resulted from cooking in apartments. Performance of over-the-range microwaves with integrated exhaust fans was similar to that of range hoods of comparable price. Simulation analysis found that performance standards need to be updated to ensure that kitchen exhaust ventilation adequately protects for substantial cooking in new California residences.

03 NATURAL GAS↗

Developing Performance Cost Index Targets for ASHRAE Standard 90.1 Appendix G – Performance Rating Method

Appendix G, the Performance Rating Method in ASHRAE Standard 90.1 has been updated to make two significant changes for the 2016 edition, to be published in October of 2016. First, it allows Appendix G to be used as a third path for compliance with the standard in addition to rating beyond code building performance. This prevents modelers from having to develop separate building models for code compliance and beyond code programs. Using this new version of Appendix G to show compliance with the 2016 edition of the standard, the proposed building design needs to have a performance cost index (PCI) less than targets shown in a new table based on building type and climate zone. The second change is that the baseline design is now fixed at a stable level of performance set approximately equal to the 2004 code. Rather than changing the stringency of the baseline with each subsequent edition of the standard, compliance with new editions will simply require a reduced PCI (a PCI of zero is a net-zero building). Using this approach, buildings of any era can be rated using the same method. The intent is that any building energy code or beyond code program can use this methodology and merely set the appropriate PCI target for their needs. This report discusses the process used to set performance criteria for compliance with ASHRAE Standard 90.1-2016 and suggests a method for demonstrating compliance with other codes and beyond code programs.

99 GENERAL AND MISCELLANEOUS↗

Developing Performance Cost Index Targets for ASHRAE Standard 90.1 Appendix G – Performance Rating Method - Rev.1

Appendix G, the Performance Rating Method in ASHRAE Standard 90.1 has been updated to make two significant changes for the 2016 edition, to be published in October of 2016. First, it allows Appendix G to be used as a third path for compliance with the standard in addition to rating beyond code building performance. This prevents modelers from having to develop separate building models for code compliance and beyond code programs. Using this new version of Appendix G to show compliance with the 2016 edition of the standard, the proposed building design needs to have a performance cost index (PCI) less than targets shown in a new table based on building type and climate zone. The second change is that the baseline design is now fixed at a stable level of performance set approximately equal to the 2004 code. Rather than changing the stringency of the baseline with each subsequent edition of the standard, compliance with new editions will simply require a reduced PCI (a PCI of zero is a net-zero building). Using this approach, buildings of any era can be rated using the same method. The intent is that any building energy code or beyond code program can use this methodology and merely set the appropriate PCI target for their needs. This report discusses the process used to set performance criteria for compliance with ASHRAE Standard 90.1-2016 and suggests a method for demonstrating compliance with other codes and beyond code programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of net direct current on the properties of radio frequency sheaths: simulation and cross-code comparison

In order to understand, predict and control ion cyclotron range of frequency (ICRF) interactions with tokamak scrape-off layer plasmas, computational tools which can model radio frequency (RF) sheaths are needed. In particular, models for the effective surface impedance and DC rectified sheath potentials may be coupled with full wave RF simulation codes to predict self-consistent wave fields near surfaces and the resulting power dissipation and plasma-material interactions from ion sputtering. In this study, previous work assuming zero net DC current flow through the sheath is generalized to allow the surface to collect net positive or negative current, as is often observed in experiments. The waveforms, DC potential and RF admittance are investigated by means of analytical theory, nonlinear fluid and particle-in-cell (PIC) codes. Cross-code comparisons provide detailed model verification and elucidate the roles of ion and electron kinetics. When the sheath draws negative (positive) DC current, the voltage rectification is reduced (increased) compared with the zero-current case, and the magnitude of both the real and imaginary parts of the admittance are increased (reduced). In conclusion, a previous four-input parametrization of the sheath rectification and admittance properties is generalized to include a fifth parameter describing the DC sheath current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Breaking the 20 Year Logjam to Better Insulating Windows

Windows account for about 4 Quads of US energy consumption or 12% of building energy use. After 20 years of public/private investment (from 1980 to 2000) in technology R&D, coupled with new rating and labeling organizations (NFRC) and with subsequent voluntary ENERGY STAR programs and tighter codes and standards, windows using low-E/argon gas fill (~R3) gained a dominant market share and now account for >86% of all annual sales. However, this remarkable transformation of prior markets has stagnated, with triple glazing (~R5-R7) comprising less than 2% of all window sales in 2016. U.S. Department of Energy (DOE) estimates the national technical potential savings using R5-R7 windows at ~ 2Q annually, but manufacturers claim they would have to redesign their entire sash/frame inventory to accommodate the thicker and heavier insulating glass units (IGUs) in conventional triple glazed window designs. This paper outlines the initial findings from the first phase of a new collaborative effort, now underway with industry partners, to transform window markets to the R5-R7 insulating levels by introducing a novel packaging of existing technology elements, implemented as a “drop-in replacement” for current IGUs. The program involves working with supply chain partners to ensure component availability, with leading window manufacturers to integrate the key technology elements and initially deploy the new designs, and with market pull partners to speed adoptions rates. Market pull partners include building code officials, utility rebate/incentive programs and ENERGY STAR, along with early adopters such as builders targeting net zero and passive house designers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗