Search NASA⌕ Search

SEARCH · Search NASA

Results for “network perimeter control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A Novel Sliding Mode Network Perimeter Controller

Congestion in urban areas is a chronic problem that faces many US and worldwide cities. It results in inefficient use of the infrastructure as well as increased fuel consumption and vehicle emissions. Congestion is intertwined with delay. Road users waste precious hours on the road, which reduces productivity. Throughout this decade researchers were and are developing tools and systems that alleviate this problem. Network perimeter control is one of these tools that has been studied extensively. It attempts to control the flow of vehicles entering a protected area so as not to reach the congested regime that is pre-determined using the Network Fundamental Diagram (NFD). In this paper, we present a novel and simple approach derived from sliding mode control theory that achieves the desired objective. Its main advantages over other control strategies include but are not limited to (1) ease of implementation, (2) minimal and straightforward model tuning, and (3) high performance. This controller was implemented and tested on a congested grid network. The results show that, the new logic performs as expected, producing network-wide delay savings that are consistent with other control approaches described in the literature. Furthermore, unlike other controllers, we demonstrate that the controller is robust to its hyper-parameter values, making the algorithm easy to implement and calibrate to local conditions. http://pubsindex.trb.org/

Sliding mode control, network perimeter control, n↗

Sliding Mode Network Perimeter Control

Urban traffic congestion is a chronic problem faced by many cities in the US and worldwide. It results in inefficient infrastructure use as well as increased vehicle fuel consumption and emission levels. Congestion is intertwined with delay, as road users waste precious hours on the road, which in turn reduces productivity. Researchers have developed, and continue to design, tools and systems to alleviate this problem. Network perimeter control is one such tool that has been studied extensively. It attempts to control the flow of vehicles entering a protected area to ensure that the congested regime predetermined by the Network Fundamental Diagram (NFD) is not reached. In this paper, a method derived from sliding mode control theory is presented. Its main advantages over proportional-integral controllers include (1) minimal tuning, (2) no linearization of the governing equations, (3) no assumptions with regard to the shape of the NFD, and (4) ability to handle various demand profiles without the need to retune the controller. A sliding mode controller was implemented and tested on a congested grid network. The results show that the proposed controller produces network-wide delay savings and disperses congestion effectively.

42 ENGINEERING↗

Implementation and Investigation of a Weather- and Jam Density-tuned Network Perimeter Controller

This paper implements and evaluates the performance of a network fundamental diagram (NFD) proportional-integral perimeter controller (PC) using base tuned parameters (clear weather conditions and a base jam density of 160 veh/km/lane). The parameters were then re-tuned separately for different weather conditions and jam density values (reflecting different percentage of trucks), resulting in two new control methods: a weather-tuned perimeter controller (WTPC) and a jam density-tuned perimeter controller (JTPC). The WTPC was shown to outperform the no control strategy and the PC for different weather conditions. Specifically, the WTPC decreased the congestion inside the protected network (PN) and improved the overall performance of the full network (FN) by decreasing the average vehicle travel time, decreasing the vehicle total delay, increasing the average vehicle speed and decreasing the average vehicle fuel consumption. Alternatively, the JTPC was shown to perform similar to the PC for jam densities higher than the base-case jam density used in the PC (in our case 160 veh/km/lane). However, the JTPC outperformed the PC for smaller jam densities given that these smaller jam densities result in queues spilling back faster to upstream traffic signals. The results demonstrate the need to tune the controller to the actual jam density especially when the jam density decreases (e.g. trucks are introduced to the network). http://pubsindex.trb.org/

42 ENGINEERING↗

On the evaluation and selection of network-level traffic control policies: Perimeter control, TUC, and their combination

Perimeter control (PC) of urban traffic networks can be effective in increasing network-wide efficiency. PC operates on the border of a protected region of a traffic network. Most studies thus far considered fixed-time plans for the inner part of these regions. A few studies have shown that combining PC with locally actuated or decentralized traffic control systems may have positive effects on traffic performance, including better-defined Network Macroscopic Fundamental Diagrams (NMFDs), increased network throughput, and reduced delays. The Traffic-responsive Urban Control (TUC) is a real-time network-wide traffic control system with particular design characteristics, such as the balancing of link's occupancies and an inherent gating feature. These characteristics suggest that TUC may enhance the traffic network performance when combined with PC whilst improving the resulting NMFDs and network throughput and delays. Here, in this work, we investigate the effect of feedback perimeter control (FPC), TUC, and their combination on the NMFD and on the traffic conditions of general traffic and public transport in the microsimulation of a realistic model of the Christchurch Central Business District in New Zealand. We perform a thorough investigation of practical aspects of both control strategies and their combination, including parameter tuning and infrastructure requirements, and how they may affect the control system choice. Results show higher throughput and less hysteresis on the NMFDs, particularly when TUC is involved. PC provides benefits concentrated in the protected region which can greatly benefit public transportation if there is an overlap with the transit network. The combination of TUC and FPC boosts network-wide throughput.

33 ADVANCED PROPULSION SYSTEMS↗

Vehicle Platooning: An Energy Consumption Perspective

Urban traffic congestion is a chronic problem faced by many cities in the US and worldwide. It results in inefficient infrastructure use as well as increased vehicle fuel consumption and emission levels. Excessive fuel consumptions add extra costs to commuters as well as transportation businesses. Consuming less fuel and thus reducing costs by a single percentage digit can have a significant impact on the balance sheet as well as the protection of the environment. Researchers have developed, and continue to develop, tools and systems to optimize the operations of fleets as well as engines in order to burn less fuel and therefore generate less CO2 emissions. Platooning is one such tool that attempts to maintain relatively small distances (i.e. pre-determined time gap) between consecutive vehicles. It has the potential to increase the capacity of the road as well as reduce the consumed fuel. In this paper, we use a fuel consumption model for internal combustion light-duty vehicles, electric vehicles, hybrid electric vehicles, buses and trucks in order to determine and quantify the effects of platooning on a fleet fuel consumption. The results suggest that a reduction of up to 3%, 3.5%, 4.5 %, 10%, and 15% in fuel consumption can be achieved for internal combustion engine vehicles, hybrid electric vehicles, electric vehicles, buses and trucks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intrusion Monitoring in Process Control Systems

To protect process control networks from cyber intrusions, preventive security measures such as perimeter defenses (for example, network firewalls and demilitarized zones) and secure versions of process control network protocols have been increasingly adopted or proposed. Although system hardening and fixing known vulnerabilities of existing systems are crucial to secure process control systems, intrusion monitoring is essential to ensure that the preventive measures are not compromised or bypassed. Our approach involves a multilayer security architecture for monitoring process control systems to achieve accurate and effective situational awareness. Also, we leverage some of the characteristics of process control systems such as the regularity of network traffic patterns to perform intrusion detection, with the potential to detect unknown attacks. To facilitate human analysts to gain a better understanding of anomalous network traffic patterns, we present a visualization tool that supports multiple usercustomizable views and animation for analyzing network packet traces.

97 MATHEMATICS AND COMPUTING↗

Securing Grid Communications Infrastructure: Addressing Gaps Beyond NERC CIP Facility Perimeters

The North American electric grid relies on a complex communications infrastructure that extends beyond facility perimeters traditionally covered by NERC Critical Infrastructure Protection (CIP) standards. While CIP requirements have significantly strengthened cybersecurity within Electronic Security Perimeters, many operational communications—such as those between control centers, substations, and third-party networks—fall outside current regulatory scope. As grid modernization introduces new technologies and connectivity models, these external pathways present evolving security challenges. This brief explores the nature of these challenges, including emerging attack vectors and supply chain considerations, and highlights how ongoing grid transformation increases exposure to sophisticated threats. It outlines practical strategies and policy options to complement existing standards, such as expanding secure communications practices, enhancing supply chain transparency, and fostering collaboration among federal, state, and industry stakeholders. Near-term actions like encryption, authentication, and contractual safeguards can help reduce risk while longer-term frameworks are developed to ensure resilient and secure grid operations.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Laboratory Validation of Integrated Lighting Systems Retrofit Performance and Energy Savings

Light-emitting diodes (LED) fixtures and lamps have emerged as leading technologies for general illumination and are a well-established energy efficiency retrofit measure in commercial buildings (from around 2% of installed fixtures and lamps in 2013 to 28% by 2020). Retrofit approaches that integrate elements, such as networked controls, daylight dimming, and advanced shade technologies lag in comparison. Integrated retrofits have been shown to increase savings over single end-use retrofits, but are perceived as higher complexity and risk. More validation of integrated lighting system performance is needed. This study presents results from laboratory testing of three packages combining fixtures, networked controls, task tuning, and daylight dimming, advanced shades, and lighting layout changes. We characterize performance in perimeter open-office zones, finding energy savings from 20% for daylight dimming and automated shades (no LED retrofit) to over 70% for LED retrofits with advanced controls and shades or lighting layout changes. We present some implementation details, including lessons learned from installation and commissioning in the laboratory setting. We also discuss cost-benefit analysis approaches for the types of packages presented, including the need to quantify and incorporate energy and non-energy benefits for advanced shades packages, which enhance occupant comfort but add significant cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Vehicle (In)Security

Nuclear and radioactive material is routinely transported worldwide every day. Since 2010, the complexity of the transport vehicle to support such activities has grown exponentially. Many core functions of a vehicle are now handled by small embedded computer modules with more being added each year to enhance the owner’s experience and convenience. With a system as complex as today’s automobile, the potential for cyber security issues is certain. Hackers have begun exploring this new domain with public information increasingly disseminated. Because vehicles are allowed into and around secure nuclear facilities, the potential for using a vehicle as a new cyber entry point or vector into the facility is now plausible and must be mitigated. In addition, compromising such a vehicle could aide in illicit removal of nuclear material, putting sensitive cargo at risk. Because cyber attacks can now be introduced using vehicles, cyber security, needs to be integrated into an organization’s design basis threat document. Essentially, a vehicle now extends the perimeter for which security professionals are responsible.Electronic Control Units (ECU) responsible for handling all core and ancillary vehicle functions are interconnected using the controller area network (CAN) bus. A typical CAN network in a modern automobile contains 50 or more ECUs. The CAN protocol now supports a wide variety of areas, including automotive, road transportation, rail transportation, industrial automation, power generation, maritime, military vehicles, aviation, and medical devices. In many ways, the nuclear industry is employing the CAN bus protocol or other similar broadcast serial networks. This paper will provide an overview of the current state of automobile and CAN Bus security, as well as an overview of what has been publicly disclosed by many research organizations. It will then present several hypotheses of how vehicle security issues may impact nuclear activities. An initial discussion of how a vehicle can be used as a new threat vector to penetrate secure facilities will be presented. This includes how a modern automobile can be used as the exploitation mechanism for nearby devices such as laptops, cell phones, and wireless access points. Additional discussion will highlight how vehicle security might impact transportation of nuclear material through remote exploitation of a moving vehicle. The final discussion will include what possible implications might be relative to the physical protection systems at nuclear facilities. The audience will also be given details regarding the complexity of attack, thus implying the likelihood of successful exploitation, and information on how such attacks may be mitigated. Emerging security products for automobiles will be discussed and other mitigation methods will be detailed (e.g. disabling vehicle cellular modems). As a result, the audience will have a greater understanding of how to add vehicle security as a part of a comprehensive nuclear security policy.Finally, this paper will highlight the similarities between CAN Bus and other broadcast serial bus networks such as Profibus or DeviceNet, helping educate the reader on how susceptible this type of networking is to nefarious attacks and how it might affect components connected to many different nuclear systems, including control systems, safety systems, emergency systems, and support systems.

47 OTHER INSTRUMENTATION↗

Evaluation Report on "The Department's Unclassified Cyber Security Program"

Industry experts report that security challenges and threats are continually evolving as malicious activity has become more web-based and attackers are able to rapidly adapt their attack methods. In addition, the number of data breaches continues to rise. In an effort to mitigate and address threats and protect valuable information, the Department of Energy anticipated spending about $275 million in Fiscal Year (FY) 2009 to implement cyber security measures necessary to protect its information technology resources. These systems and data are designed to support the Department's mission and business lines of energy security, nuclear security, scientific discovery and innovation, and environmental responsibility. The Federal Information Security Management Act of 2002 (FISMA) provides direction to agencies on the management and oversight of information security risks, including design and implementation of controls to protect Federal information and systems. As required by FISMA, the Office of Inspector General conducts an annual independent evaluation to determine whether the Department's unclassified cyber security program adequately protects its information systems and data. This memorandum and the attached report present the results of our evaluation for FY 2009. The Department continued to make incremental improvements in its unclassified cyber security program. Our evaluation disclosed that most sites had taken action to address weaknesses previously identified in our FY 2008 evaluation report. They improved certification and accreditation of systems; strengthened configuration management of networks and systems; performed independent assessments; and, developed and/or refined certain policies and procedures. In addition, the Department instituted a centralized incident response organization designed to eliminate duplicative efforts throughout the Department. As we have noted in previous reports, the Department continued to maintain strong network perimeter defenses against malicious intruders and other externals threats. These are positive accomplishments. However, in our judgment, additional action is required to further enhance the Department's unclassified cyber security program and help reduce risks to its systems and data. For example, our current review identified opportunities for improvements in areas such as security planning and testing, systems inventory, access controls, and configuration management. In particular, we issued a number of findings at sites managed by the National Nuclear Security Administration (NNSA). We also identified weaknesses across various Department program elements. Issues that warrant further attention include: (1) Weaknesses such as outdated security plans and not completing annual security control self-assessments were identified at several sites; (2) The Department had not yet resolved systems inventory issues and had yet to deploy a complex-wide automated asset management tool to help track information technology resources and identify interfaces between systems or networks; (3) Although certain improvements had been made to enhance access controls, we noted deficiencies such as a lack of periodic account reviews and inadequate password management at a number of sites; and (4) Previously identified weaknesses in configuration management had been corrected, however, we found problems related to weak administrator account settings and failure to install software patches, as well as incomplete implementation of the Federal Desktop Core Configuration. These internal control weaknesses existed, at least in part, because certain cyber security roles and responsibilities were not clearly delineated. Program officials also had not effectively performed monitoring and review activities essential for evaluating the adequacy of cyber security performance. In some cases, officials had not ensured that weaknesses discovered during audits and other evaluations were recorded and tracked to resolution in the organizations' Plans of Action and Milestones. Our testing disclosed that about 39 percent of existing corrective action milestones had missed estimated remediation dates, with many exceeding planned completion dates by at least one year. As a consequence, the risk of compromise to the Department's information and systems remained higher than necessary. To assist the continuing efforts to improve, we made several recommendations designed to help the Department's managers to strengthen the unclassified cyber security program and, thereby, protect its computer resources from unauthorized modification, loss, or disclosure of information. Due to security considerations, information on specific vulnerabilities and locations has been omitted from this report. Management officials at the sites evaluated were provided with detailed information regarding identified vulnerabilities, and, in many instances, initiated corrective actions.

99 GENERAL AND MISCELLANEOUS↗

National-Tribal Critical Infrastructure Protection: Collaboration for Extraordinary National Security Benefit

This paper examines national and tribal collaborative opportunities to get ahead of the critical infrastructure insecurity problem. Recommendations are viewed through the lens of the Sandia Labs Tribal Cyber-Energy initiative and national security projects. Recommendations include 1) Collaboratively address national priority and shared challenges to gain faster and better solutions to national priority problems on a smaller yet comprehensive American Indian and Alaskan Native sovereign single-point of authority scale 2) Utilize newer standards-based technologies to provide scalable, capable, and manageable solutions for greatly expanded and connected national critical infrastructures 3) Employ Cyber-Physical-Resilient design preliminary analysis to define concept- to-disposition design requirements for preemptive critical infrastructure risk mitigation and baked-in security; 4) Develop data-centric protection to provide increased information asset protection as data shifts from data-owner operated on-premises infrastructure to virtual service provider data-steward owned and operated off-premises infrastructure; and 5) Balance shared solutions with the National Institute of Science and Technology (NIST) Cybersecurity and Risk Management frameworks, and the System Security Engineering Guidelines. As yet unallocated federal funding would support research, development, the timely application of National-Tribal critical infrastructure protection, and critical infrastructure Cyber disruption response and recovery with extraordinary mutual benefits for the foreseeable future. The Critical Infrastructure Insecurity Problem: Rapid modernization and expansive connectivity are due to advances in Information and Communications Technologies that have sweeping cyber impact across all critical infrastructure sectors. Supervisory Control and Data Acquisition and Industrial Control Systems are particularly impacted as systems long separated from the Internet are now being connected and computerized. Virtualization and mobility create a Data Everywhere-User Anywhere paradigm that has evaporated the enterprise network perimeter. There are multi-front technological challenges at play, where long depended on technologies simply don't scale to current needs resulting in a digital dichotomy of competing old and new standards. New standards-based technologies scale but are not as well-known or as widely deployed, which leaves decision makers, stakeholders, and the workforce in a quandary, caught mid-stream between the technological past and the virtual future. Rapid and expansive cyber threat accompanies disruptive change in connectivity and computational dependencies. A lack of action will exacerbate the problem if new technologies roll out without baked-in security design. The Risk: If National-Tribal CIP collaboration to design in security is not done, then an ongoing state of insufficient bolt-on security and elevated threat exposure will remain for years to come.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Anomaly Detection Using Optimally-Placed μPMU Sensors in Distribution Grids

IEEE As the distribution grid moves toward a tightly-monitored network, it is important to automate the analysis of the enormous amount of data produced by the sensors to increase the operators situational awareness about the system. Here, focusing on Micro-Phasor Measurement Unit (μPMU) data, we propose a hierarchical architecture for monitoring the grid and establish a set of analytics and sensor fusion primitives for the detection of abnormal behavior in the control perimeter. And due to the key role of the μPMU devices in our architecture, a source-constrained optimal μPMU placement is also described that finds the best location of the devices with respect to our rules. The effectiveness of the proposed methods are tested through the synthetic and real μPMU data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Blockchain based Communication Architectures with Applications to Private Security Networks

Existing communication protocols in high consequence security networks are highly centralized. While this naively makes the controls easier to physically secure, external actors require fewer resources to disrupt the system because there are fewer points in the system can be destroyed or interrupted without the entire system failing. We present a solution to this problem using a proof-of-work-based blockchain implementation built on MultiChain. We construct a test-bed network containing two types of data input: visual imagers and microwave sensor information. These data types are ubiquitous in perimeter intrusion detection security systems and allow a realistic representation of a real-world network architecture. The cameras in this system use an object detection algorithm to nd important targets in the scene. The raw data from the camera and the outputs from the detection algorithm are then placed in a transaction on the distributed ledger. Similarly, microwave data is used to detect relevant events and are placed in a transaction. These transactions are then bundled into blocks and broadcast to the rest of the network using the Bitcoin-based MultiChain protocol. We develop five tests to examine the security metrics of our network. We performed the five security metric test using different sized networks from 7 to 39 nodes to determine how the metrics scale with respect to size. We nd that when compared to a centralized architecture our implementation provides a resiliency increase that is expected from a blockchain-based protocol without slowing the system so much that a human operator would notice. Furthermore, our approach is able to detect tampering in real time. Based on these results, we theorize that security networks in general could use a blockchain-based approach in a meaningful way.

97 MATHEMATICS AND COMPUTING↗

Exe-Guard Project

The exe-Guard Project is an alliance between Dominion Virginia Power (DVP), Sandia National Laboratories (SNL), Dartmouth University, and Schweitzer Engineering Laboratories (SEL). SEL is primary recipient on this project. The exe-Guard project was selected for award under DE-FOA-0000359 with CFDA number 81.122 to address Topic Area of Interest 4: Hardened platforms and Systems. The exe-Guard project developed an antivirus solution for control system embedded devices to prevent the execution of unauthorized code and maintain settings and configuration integrity. This project created a white list antivirus solution for control systems capable of running on embedded Linux® operating systems. White list antivirus methods allow only credible programs to run through the use of digital signatures and hash functions. Once a system’s secure state is baselined, white list antivirus software denies deviations from that state because of the installation of malicious code as this changes hash results. Black list antivirus software has been effective in traditional IT environments but has negative implications for control systems. Black list antivirus uses pattern matching and behavioral analysis to identify system threats while relying on regular updates to the signature file and recurrent system scanning. Black list antivirus is vulnerable to zero day exploits which have not yet been incorporated into a signature file update. System scans hamper the performance of high availability applications, as revealed in NIST special publication 1058 which summarizes the impact of blacklist antivirus on control systems: Manual or “on-demand” scanning has a major effect on control processes in that they take CPU time needed by the control process (Sometimes close to 100% of CPU time). Minimizing the antivirus software throttle setting will reduce but not eliminate this effect. Signature updates can also take up to 100% of CPU time, but for a much shorter period than a typical manual scanning process. Control systems are vulnerable to performance losses if off-the-shelf blacklist antivirus solutions aren’t implemented with care. This investment in configuration in addition to constant decommissioning to perform manual signature file updates is unprecedented and impractical. Additionally, control systems are often disconnected or islanded from the network making the delivery of signature updates difficult. Exe-Guard project developed a white list antivirus solution that mitigated the above drawbacks and allows control systems to cost-effectively apply malware protection while maintaining high reliability. The application of security patches can also be minimized since white listing maintains constant defense against unauthorized code execution. Security patches can instead be applied in less frequent intervals where system decommissioning can be scheduled and planned for. Since control systems are less dynamic than IT environments, the feasibility of maintaining a secure baselined state is more practical. Because upgrades are performed in infrequent, calculated intervals, it allows a new security baseline to be established before the system is returned to service. Exe-Guard built on the efforts of SNL under the Code Seal project. SNL demonstrated prototype Trust Anchors on the project which are independent monitoring and control devices that can be integrated into untrustworthy components. The exe-Guard team started with the lessons learned under this project then designed commercial solution for white list malware protection. Malware is a real threat, even on islanded or un-networked installations, since operators can unintentionally install infected files, plug in infected mass storage devices, or infect a piece of equipment on the islanded local area network that can then spread to other connected equipment. Protection at the device level is one of the last layers of defense in a security-in-depth defense model before an asset becomes compromised. This project provided non-destructive intrusion, isolation and automated response solution, achieving a goal of the Department of Energy (DOE) Roadmap to Secure Control Systems. It also addressed CIP-007-R4 which requires asset owners to employ malicious software prevention tools on assets within the electronic security perimeter. In addition, the CIP-007-R3 requirement for security patch management is minimized because white listing narrows the impact of vulnerabilities and patch releases. The exe-Guard Project completed all tasks identified in the statement of project objective and identified additional tasks within scope that were performed and completed within the original budget. The cost share was met and all deliverables were successfully completed and submitted on time. Most importantly the technology developed and commercialized under this project has been adopted by the Energy sector and thousands of devices with exe-Guard technology integrated in them have now been deployed and are protecting our power systems today

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pattern formation during healing of fluid-filled cracks: an analog experiment

The formation and subsequent healing of cracks and crack networks may control such diverse phenomena as the strengthening of fault zones between earthquakes, fluid migrations in the Earth's crust, or the transport of radioactive materials in nuclear waste disposal. An intriguing pattern-forming process can develop during healing of fluid-filled cracks, where pockets of fluid remain permanently trapped in the solid as the crack tip is displaced driven by surface energy. Here, we present the results of analog experiments in which a liquid was injected into a colloidal inorganic gel to obtain penny-shaped cracks that were subsequently allowed to close and heal under the driving effect of interfacial tension. Depending on the properties of the gel and the injected liquid, two modes of healing were obtained. In the first mode, the crack healed completely through a continuous process. The second mode of healing was discontinuous and was characterized by a 'zipper-like' closure of a front that moved along the crack perimeter, trapping fluid that may eventually form inclusions trapped in the solid. This instability occurred only when the velocity of the crack tip decreased to zero. Our experiments provide a cheap and simple analog to reveal how aligned arrays of fluid inclusions may be captured along preexisting fracture planes and how small amounts of fluids can be permanently trapped in solids, modifying irreversibly their material properties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗