Search NASA⌕ Search

SEARCH · Search NASA

Results for “network topology optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optimal Network Topology for Node-Breaker Representations With AC Power Flow Constraints

It has been demonstrated that network topology optimization (NTO) may change the topology of power system networks, and consequently, provide additional flexibility to reduce network congestion and violations. Most NTO problems are formulated based on the bus-branch model in which it is challenging to represent a realistic picture of all substation configurations. In this paper, we explore advantages of substation reconfiguration modeling based on node-breaker representations for NTO problem with full nonlinear alternating current power flow. It also proposes a tailored solution algorithm to solve this nonconvex mixed-integer nonlinear programming through the outer approximation method. The proposed solution approach iterates between a mixed-integer linear programming and a nonlinear subproblem. Additional enhancements to further accelerate the iteration process are illustrated. Numerical case studies demonstrate the relative economic and operational impact of optimal network topology with node-breaker representations.

42 ENGINEERING↗

Optimal Network-Topology Design

Candidate network designs tested for acceptability and cost. Optimal Network Topology Design computer program developed as part of study on topology design and analysis of performance of Space Station Information System (SSIS) network. Uses efficient algorithm to generate candidate network designs consisting of subsets of set of all network components, in increasing order of total costs and checks each design to see whether it forms acceptable network. Technique gives true cost-optimal network and particularly useful when network has many constraints and not too many components. Program written in PASCAL.

Li, Victor O. K.↗

Switch Opening and Exchange Method for Stochastic Distribution Network Reconfiguration

The purpose of distribution network reconfiguration (DNR) is to determine the optimal topology of an electricity distribution network, which is an efficient measure to reduce network power losses. Electricity load demand and photovoltaic (PV) output are uncertain and vary with time of day, and will affect the optimal network topology. Single-hour deterministic DNR is incapable of handling this uncertainty and variability. Therefore, this paper proposes to solve a multi-hour stochastic DNR (SDNR). Existing solution methods for DNR are either inaccurate or excessively time-consuming, and are therefore incapable of solving multi-hour SDNRs for large distribution networks. In this regard, a switch opening and exchange (SOE) method is proposed. Starting from a looped network with all switches closed, the SOE consists of three steps. The first step is to sequentially open the switches until all of the loops are opened. The second and third steps modify the status of branches obtained in the first step to obtain better radial topologies. Five test systems are used to validate the accuracy and fast solution speed of the SOE and the superiority of multi-hour SDNR over single-hour deterministic DNR.

distribution network reconfiguration↗

Evaluation of low-exergy heating and cooling systems and topology optimization for deep energy savings at the urban district level

District energy systems have the potential to achieve deep energy savings by leveraging the density and diversity of loads in urban districts. However, planning and adoption of district thermal energy systems is hindered by the analytical burden and high infrastructure costs. It is hypothesized that network topology optimization would enable wider adoption of advanced (ambient temperature) district thermal energy systems, resulting in energy savings. In this study, energy modeling is used to compare the energy performance of “conventional” and “advanced” district thermal energy systems at the urban district level, and a partial exhaustive search is used to evaluate a heuristic for the topology optimization problem. For the prototypical district considered, advanced district thermal energy systems mated with low-exergy building heating and cooling systems achieved a source energy use intensity that was 49% lower than that of conventional systems. The minimal spanning tree heuristic was demonstrated to be effective for the network topology optimization problem in the context of a prototypical district, and contributes to mitigating the problem’s computational complexity. The work presented in this paper demonstrates the potential of advanced district thermal energy systems to achieve deep energy savings, and advances to addressing barriers to their adoption through topology optimization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Finding Your Niche: An Evolutionary Approach to HPC Topologies

Traditional interconnection network design approaches focus on building general network topologies by optimizing the bisection bandwidth or minimizing the network’s diameter to reduce the maximum distance between any two nodes, thus amortizing the overall execution time of the HPC workloads. While such network topologies may accommodate a wide variety of applications in general, this may result in sub-optimal performance for many frequently-executed or dynamic workloads. In this paper, instead of focusing on designing an all-encompassing, general-purpose network topology, we develop a methodology to design customized network interconnects, evolved by “finding” the optimal topologies for a particular target workload given by its communication and contention profiles. To this end, we implement a Genetic Algorithm (GA)-based approach for network topology design tailored to improve the overall execution time of a particular workload of interest. We conducted extensive experiments with well-known motifs in physics-based workloads (Sweep3D and FFT), as well as with a representative graph application (MiniVite), using the well-known Structural Simulation Toolkit (SST) Macroscale Element Library (SST/macro) simulator for network interconnect evaluation. We demonstrate that our genetic algorithm-based approach is robust enough to find the underlying optimal topology of a particular workload.

network interconnects, graph search, meta-heuristi↗

Switching Device-Cognizant Sequential Distribution System Restoration

This paper presents an optimization framework for sequential reconfiguration using an assortment of switching devices and repair process in distribution system restoration. Compared to existing studies, this paper considers types, capabilities and operational limits of different switching devices, making it applicable in practice. We develop a novel multi-phase method to find the optimal sequential operation of various switching devices and repair faulted areas. We consider circuit breakers, reclosers, sectionalizers, load breaker switches, and fuses. The switching operation problem is decomposed into two mixed-integer linear programming (MILP) subproblems. The first subproblem determines the optimal network topology and estimates the number of steps to reach that topology, while the second subproblem generates a sequence of switching operations to coordinate the switches. For repairing the faults, we design an MILP model that dispatches repair crews to clear faults and replace melted fuses. After clearing a fault, we update the topology of the network by generating a new sequence of switching operations, and the process continues until all faults are cleared. To improve the computational efficiency, a network reduction algorithm is developed to group line sections, such that only switchable sections are present in the reduced network. The proposed method is validated on the IEEE 123-bus and 8500-bus systems.

distribution system↗

A Topology Optimization Framework to Facilitate Adoption of Advanced District Thermal Energy Systems

Advanced district thermal energy systems, which circulate water at temperatures near ambient conditions, and facilitate the utilization of waste heat and renewable thermal sources, can lower the carbon-intensity of urban districts, advancing the U.N. Sustainable Development Goals. Optimization of the network topology — the selection of the best subset of buildings and the best network to connect them, to minimize life cycle cost — can increase adoption of these system in appropriate applications. The potential "solution space" of the topology optimization problem grows factorially with the number of buildings in the district, motivating the consideration of a design heuristic. In this study, a heuristic for the network selection was evaluated with an exhaustive search, for a prototypical four-building district. For the prototypical district considered, the heuristic was effective in selecting an optimal network topology. Additionally, it was found that, in this case, the selection of the subset of buildings was more influential on the life cycle cost than the selection of the network topology. This work is part of a larger effort to develop a topology optimization framework for district thermal energy systems, which is anticipated to address barriers to adoption of ambient-temperature systems.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Optimal environmental and economic performance trade-offs for fifth generation district heating and cooling network topologies with waste heat recovery

Network topology greatly influences both the economic and environmental performance of fifth generation district heating and cooling (5GDHC) systems. In this study the optimal trade-offs between the environmental and economic performance of 5GDHC network topologies for a five-building district with waste heat recovery were explored. A life cycle assessment method was used to calculate the total life cycle CO 2 emissions (LCCO2) associated with the installation and operation of various network topologies. Twelve months of empirical data from a data center cooling system were analyzed to assess its suitability for integration into a 5GDHC system. The most suitable method for utilizing this waste heat was selected based on the ambient loop warm pipe setpoint, waste heat temperature, and district energy system configuration. A multi-objective optimization algorithm was used to select the 5GDHC network topology that provided the optimal trade-off between LCCO2 and life cycle cost (LCC). A trade-off parameter was employed to weigh the importance of each objective in the selection process. The results showed waste heat from the data center was suitable for integration into the 5GDHC system due to its availability and consistent temperature profile. When return temperatures of 25 °C or higher were available from the liquid-cooled system, direct pre-heating of the ambient loop warm pipe was found to be the most effective waste heat integration method. The selection of the network topology that provided the optimal trade-off between LCCO2 and LCC (optimal trade-off topology) was highly dependent on factors such as fuel prices, CO 2 prices, electricity CO 2 emissions factors, availability of waste heat, embodied CO 2 emissions associated with network installation and network infrastructure costs. Optimal trade-off topologies produced substantial LCCO2 reductions relative to corresponding LCC increases. LCCO2 reduction to LCC increase ratios from 5.78 to 117.79 were identified with CO 2 offset costs ranging from 4.77 to 60.08 ($/tCO 2 e).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of Distribution Feeder Topology: A Differential Programming Learning Approach

This paper presents a gradient based method for optimizing distribution feeder network topology under load un- certainty. We recast the optimal network reconfiguration problem as a learning problem where edge weights of a graph are learned to produce an optimized spanning tree for a distribution network. Using recent methods published on differentiable programming, we provide a data driven method for learning these weights. We test our method on 100 variations of an IEEE 15-bus test system. Our results show that our method outperforms more traditional mathematical programming-based approaches.

differentiable programming↗

Optimizing Fast Charging and Wetting in Lithium-Ion Batteries with Optimal Microstructure Patterns Identified by Genetic Algorithm

To sustain the high-rate current required for fast charging electric vehicle batteries, electrodes must exhibit sufficiently high effective ionic diffusion. Additionally, to reduce battery manufacturing costs, wetting time must decrease. Both of these issues can be addressed by structuring the electrodes with mesoscale pore channels. However, their optimal spatial distribution, or patterns, is unknown. Herein, a genetic algorithm has been developed to identify these optimal patterns using a CPU-cheap proxy distance-based model to evaluate the impact of the added pore networks. Both coin-cell and pouch cell form factors have been considered for the wetting analysis, with their respective electrolyte infiltration mode. Regular hexagonal and mud-crack-like patterns, respectively, for fast charging and fast wetting were found to be optimal and have been compared with pre-determined, easier to manufacture, patterns. The model predicts that using cylindrical channels arranged in a regular hexagonal pattern is ∼6.25 times more efficient for fast charging as compared to grooved lines with both structuring strategies being restricted to a 5% electrode total volume loss. The model also shows that only a very limited electrode volume loss (1%–2%) is required to dramatically improve the wetting (5–20 times) compared to an unstructured electrode.

25 ENERGY STORAGE↗

Network reconfiguration and distributed energy resource scheduling for improved distribution system resilience

Electric utility companies work to restore as much load as possible after power outages caused by extreme weather events. In this paper, an outage management strategy is proposed to enhance distribution system resilience through network reconfiguration and distributed energy resources (DERs) scheduling. After a line fault, the proposed algorithm can identify radial network topology based on the rank of the incidence matrix. The reconfiguration is implemented by switching tie lines and sectionalizing lines. With the new network topology, an optimal DER scheduling problem is solved to minimize the accumulative cost for dispatchable DER operation and load reduction. Finally, the optimal topology that minimizes the accumulative cost is selected from all radial topologies. The computational workload is relatively low because only linear programming needs to be solved. Using the case studies of the IEEE 69-bus and IEEE 123-bus systems, we consider the worst-case scenarios in which faults occur in the upstream feeder. The simulation results demonstrate that the proposed strategy allows for a relatively high percentage of the load to remain in service after line faults. Furthermore, compared with microgrid-formation approaches, the proposed strategy has advantages when applied to the distribution systems with several normally-open tie lines and low DER penetration.

42 ENGINEERING↗

An optimization framework for the network design of advanced district thermal energy systems

In this work, a topology optimization framework for district thermal energy systems is presented. The framework seeks to address the questions, for a given district, "What is the best subset of buildings to connect to a district thermal energy system, and by what network should they be connected, to minimize life cycle cost?" A particle swarm optimization approach is validated to address the selection of the subset of buildings, and a graph theory-based heuristic is validated for selection of the network topology for any candidate subset of buildings. The framework is applied to a prototypical urban district for illustrative purposes. Additionally, modeling of prototypical districts revealed reductions in source energy use intensity for heating and cooling of 21-25% through the use of advanced district energy systems relative to code-compliant, building level systems. The framework identifies solutions with life cycle cost values 14% to 72% lower than that of base case scenarios based on conventional design approaches, depending on the base case scenario selected. Analysis of the search space indicates that topology optimization facilitates reductions in life cycle cost, source energy use intensity, and carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Two-Stage Quantum Reinforcement Learning Method for Multi-Objective Transmission Switching

Multi-objective transmission switching (MO-TS) problems involve the strategic reconfiguration of network topology to simultaneously optimize multiple objectives. As the system scale increases, finding feasible solutions becomes increasingly challenging due to the problem's nonlinearity and high computational complexity. To address these challenges, this paper proposes a two-stage quantum reinforcement learning method that leverages potential quantum advantages for MO-TS. In the first stage, candidate switching lines are identified using a graph-theoretical approach to reduce the problem's dimensionality. The second stage introduces a quantum-classical reinforcement learning framework, where a learnable measurement-based CNN-ResVQC architecture is developed to effectively reduce the input dimension for quantum processing, mitigate vanishing gradients, and enhance trainability while improving the quantum circuit's flexibility in modeling complex decision policies for MO-TS. Numerical studies on IEEE 14-bus, 57-bus, and 118-bus systems demonstrate that the proposed algorithm achieves superior training stability and faster convergence with approximately 1% of the network parameters required by classical algorithms, highlighting its effectiveness, efficiency, and scalability. Furthermore, the practicality is validated through its stable convergence under three common quantum noise channels.

99 GENERAL AND MISCELLANEOUS↗

Restoration Strategy for Active Distribution Systems Considering Endogenous Uncertainty in Cold Load Pickup

Cold load pickup (CLPU) phenomenon is identified as the persistent power inrush upon a sudden load pickup after an outage. Under the active distribution system (ADS) paradigm, where distributed energy resources (DERs) are extensively installed, the decreased outage duration can induce a strong interdependence between CLPU pattern and load pickup decisions. In this paper, we propose a novel modelling technique to tractably capture the decision-dependent uncertainty (DDU) inherent in the CLPU process. Subsequently, a two-stage stochastic decision-dependent service restoration (SDDSR) model is constructed, where first stage searches for the optimal switching sequences to decide step-wise network topology, and the second stage optimizes the detailed generation schedule of DERs as well as the energization of switchable loads. Further, to tackle the computational burdens introduced by mixed-integer recourse, the progressive hedging algorithm (PHA) is utilized to decompose the original model into scenario-wise subproblems that can be solved in parallel. The numerical test on modified IEEE 123-node test feeders has verified the efficiency of our proposed SDDSR model and provided fresh insights into the monetary and secure values of DDU quantification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Network Reconfiguration and Scheduling With Hardware-in-the-Loop Validation for Improved Microgrid Resilience

With the increased occurrence of various major extreme weather events, power outages and prompt power system restorations have recently drawn more attention to the resilience and recovery of power systems. From the perspective of a more resilient power delivery at the distribution grid, system restoration using network topology reconfiguration together with optimal scheduling of distributed energy resources are adopted in this paper. The proposed optimization model aims at minimizing the total load shedding cost and other operational costs, in which linearized topological constraints borrowed from graph theory and linearized DistFlow models are respectively used to maintain the radial network topology and power flow balance after system contingencies. To demonstrate the applicability of the proposed strategy, a real-world case study of a networked three-microgrid system in Adjuntas, Puerto Rico, is used with the consideration of different independent/interconnected microgrid scenarios, contingencies, and fairness settings. Furthermore, hardware-in-the-loop testing is conducted for the same three-microgrid network, where the closely matched results with the simulated ones have validated the effectiveness of the proposed restoration strategy, which is now ready to move one step forward towards field deployment. Finally, to test the proposed restoration strategy in a larger networked system, the modified IEEE-33 bus test distribution system is considered, and the results show a more resilient power delivery for critical loads under three and four line outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Evaluation of the Effect of Network Cost Optimization for Leadership Class Supercomputers

Dragonfly-based networks are an extensively deployed network topology in large-scale high-performance computing due to their cost-effectiveness and efficiency. The US will soon have three Exascale supercomputers for leadership class workloads deployed using dragonfly networks. Compared to indirect networks of similar scale, the dragonfly network has considerably reduced cable lengths, cable counts, and switch counts, resulting in significant network cost savings for a given system size, however, these cost reductions result in reduced global minimal paths and more challenging routing. Additionally, large scale dragonfly networks often require a taper at the global link level, resulting in less bisection bandwidth than is achievable in other traditional non-blocking topologies of equivalent scale. While dragonfly networks have been extensively studied, they have yet to be fully evaluated in an extreme scale (i.e., exascale) system that targets capability workloads. In this paper, we present the results of the first large scale evaluation of a dragonfly network on an exascale system (Frontier) and compare its behavior to a similar scale fat-tree network on a previous generation TOP500 system (Summit). This evaluation aims to determine the effect of network cost optimizations by measuring a tapered topology’s impact on capability workloads. Our evaluation is based on a collection of synthetic microbenchmarks, mini-apps, and full scale applications. It compares the scaling efficiencies of each benchmark between the dragonfly-based Frontier and the fat-tree-based Summit systems. Our results show that a dragonfly network is $\sim \mathbf{3 0 \%}$ more cost efficient than a fat-tree topology, which amortizes to $\sim 3 \%$ of an exascale system cost. Furthermore, while tapered dragonfly networks impose significant tradeoffs, the impacts are not as broad as initially thought and are mostly seen in applications with global communication patterns, particularly all-to-all (e.g., FFT-based algorithms), but also local communication patterns (e.g., nearest-neighbor algorithms) that are sensitive to network performance variability.

Khan, Awais↗