Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutral particle analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Guiding center model to interpret neutral particle analyzer results

The theoretical model is discussed, which accounts for drift and cyclotron components of ion motion in a partially ionized plasma. Density and velocity distributions are systematically precribed. The flux into the neutral particle analyzer (NPA) from this plasma is determined by summing over all charge exchange neutrals in phase space which are directed into apertures. Especially detailed data, obtained by sweeping the line of sight of the apertures across the plasma of the NASA Lewis HIP-1 burnout device, are presented. Selection of randomized cyclotron velocity distributions about mean azimuthal drift yield energy distributions which compared well with experiment. Use of data obtained with a bending magnet on the NPA showed that separation between energy distribution curves of various mass species correlate well with a drift divided by mean cyclotron energy parameter of the theory. Use of the guiding center model in conjunction with NPA scans across the plasma aid in estimates of ion density and E field variation with plasma radius.

Englert, G. W.↗

Interpretation of neutral particle analyzer measurements on plasmas having azimuthal drift

The theoretical model accounts for drift and cyclotron components of ion motion in a partially ionized plasma. Density and velocity distributions are systematically prescribed. The flux into the neutral particle analyzer (NPA) from this plasma is determined by summing over all charge exchange neutrals in phase space which are directed into apertures. Calculation of the process is continued through the NPA using appropriate cross section data to obtain analyzer output distributions. Theoretical results were compared with NPA measurements on four plasma heating devices having radial electric, E, and axial magnetic, B, fields. Drift velocity, in the azimuthal direction is identified with E/B. Selection of randomized cyclotron velocity distributions about mean azimuthal drift yield energy distributions which compare well with experiment.

Englert, G. W.↗

Guiding center model to interpret neutral particle analyzer results

An attempt is made to model the essential features of ion motion in a plasma. A guiding center model is hypothesized for a plasma heating device whose radial electric fields and axial magnetic fields are crossed. The guiding center model is shown to give results which agree with experimental data from four different plasma heating devices and are helpful for the interpretation of neutral particle analyzer results.

Englert, G. W.↗

Parametric study of ion heating in a burnout device (HIP-1)

Results of further studies on the Lewis Research Center hot-ion plasma source (HIP-1) are reported. Changes have been made in both the electrode geometry and materials to produce higher ion temperatures. Ion temperature increased significantly with increased vacuum pumping speed. The best ion temperatures achieved, so far, for H(+), D(+), and He(+) plasmas are estimated to be equal to, or greater than 0.6, equal to, or greater than 0.9, and equal to, greater than 2.0 keV, respectively. Electrode pairs produced high ion temperatures whether on the magnetic axis or off it by 5.5 cm. Multiple sources, one on-axis and one off-axis, were run simultaneously from a single power supply by using independent gas feed rates. A momentum analyzer has been added to the charge-exchange neutral particle analyzer to identify particles according to mass, as well as energy. Under any given plasma condition, the higher mass ions have higher average energies but not by as much as the ratio of their respective masses.

Sigman, D. R.↗

Model for interpreting Doppler broadened optical line emission measurements on axially symmetric plasma

A plasma model, previously developed to interpret neutral-particle analyzer measurements on E x B heating devices, is adapted to analyze Doppler broadened charge-exchange-neutral lines measured by an optical monochromator. Comparison of theoretical with experimental results indicates that azimuthal drift as well as cyclotron motion are quite influential in determining line shapes and widths, and thus important in temperature determination, even when the monochromator line of sight is intersecting the plasma axis of symmetry. At this central sighting position, however, results are quite insensitive to radial ion density distribution when time lag between the charge-exchange-excitation events and emission is neglected. Line shapes and widths obtained by sighting across chords of plasma at various distances from the plasma axis of symmetry indicate a strong dependence on time lag.

Englert, G. W.↗

Diurnal survey of the thermosphere. I.

Thermosphere neutral particles analyzed with rocket probe, measuring diurnal variations of molecular nitrogen and electron density and temperature altitude profiles

Ballance, J. O.↗

Steady-state hot-ion plasma produced by crossed electric and magnetic fields

Results of initial diagnostics on the Lewis Research Center hot-ion-plasma source (HIP-1) are reported. The mirror-contained plasma was heated by applying a radial electric field similar to that used in the ORNL burnout experiments. An electrostatic neutral particle analyzer was used to make a parametric study of ion energy distributions in both hydrogen and euterium plasmas. Ion temperatures as high as 2 keV were measured in plasmas with electron densities greater than 10 to 12th power/cu cm. The performance of the device was found to be extremely sensitive to a magnetic field. There are indications that ion heating was reduced when the size of the Larmor orbit was larger than the region of a strong radial electric field.

Sigman, D. R.↗

Hot ion plasma heating experiments in SUMMA

A new superconducting magnetic mirror apparatus (SUMMA) is described using photographs, diagrams, characteristics graphs, and block diagrams. The apparatus consists of a magnet facility, a plasma test section, the electrode assembly, a charge-exchange neutral particle analyzer, and apparatus for emission spectroscopy. Initial results of hot ion plasma heating experiments conducted in this facility are reported. The purpose of these experiments was twofold: (1) to make a reliable electrode assembly for steady-state operation in the new SUMMA magnetic field configuration and test-section geometry; and (2) to see how ion heating scales as the midplane magnetic field is varied up to 3.5 tesla.

Reinmann, J. J.↗

Ion and electron temperatures in the SUMMA mirror device by emission spectroscopy

Ion temperatures were obtained in the SUMMA mirror device by observing the Doppler-broadened charge-exchange component of the 667.8and 587.6-nm He lines in He plasma and the H alpha and H beta lines in H2 plasma. The second moment of the line profiles was used as the parameter to determine ion temperature. Corrections for magnetic splitting, fine structure, monochromator slit function, and variation in charge-exchange cross section with energy are derived and included. Even for constant cross section, no magnetic splitting or fine structure, and infinitely narrow slit function, the line profile is not Gaussian, because the excitation results from a change-exchange process. Comparison is made with temperatures from a neutral particle analyzer.-

Patch, R. W.↗

Hot ion plasma heating experiments in SUMMA

Initial results are presented for the hot-ion plasma heating experiments conducted in the new SUMMA (superconducting magnetic mirror apparatus) at NASA Lewis Research Center. A discharge is formed by applying a radially inward dc electric field between cylindrical anodes and hallow cathodes located at the peak of the mirrors. Data were obtained at midplane magnetic field strengths from 1.0 to 3.5 tesla. Charge-exchange neutral particle energy analyzer data were reduced to ion temperatures using a plasma model that included a Maxwellian energy distribution superimposed on an azimuthal drift, finite ion orbits, and radial variations in density and electric field. The best ion temperatures in a helium plasma were 5 keV and in hydrogen the H2(+) and H(+) ions were 1.2 keV and 1 keV respectively. Optical spectroscopy line broadening measurements yielded ion temperatures about 50 percent higher than the charge-exchange neutral particle analyzer results. Spectroscopically obtained electron temperature ranged from 3 to 30 eV. Ion temperature was found to scale roughly linearly with the ratio of power input-to-magnetic field strength, P/B.

Reinmann, J. J.↗

Hot ion plasma heating experiments in SUMMA

Initial empirical results are presented for the hot-ion plasma heating experiments conducted in the new SUMMA (Superconducting Magnetic Mirror Apparatus) at NASA Lewis Research Center. A discharge was formed by applying a radially inward dc electric field near the mirror throats. Data were obtained at midplane magnetic flux densities from 1.0 to 3.5 tesla. Charge-exchange neutral particle energy analyzer data were reduced to ion temperatures using a plasma model that included a Maxwellian energy distribution superimposed on an azimuthal drift, finite ion orbits, and radial variations in density and electric field. Using this plasma model, the highest ion temperatures computed were 5 keV, 1.2 keV, and 1 keV for He(+), H2(+), and H(+), respectively. These were obtained at a midplane magnetic flux density of 1.6 T.-

Reinmann, J. J.↗

X-ray and energetic neutral particle emission from Saturn's magnetosphere

A description is presented of observations of the Voyager 1 spacecraft obtained a few days before encounter of the Saturn magnetosphere in November 1980. As Voyager 1 has no special experiment onboard for X-ray and neutral particle detection, the sensitivity and directional measurements of the low energy charged particle (LECP) analyzer is used to identify the neutral radiation above the charged particle background. The LECP telescope uses a silicon detector of 96.6 micrometers thickness and 0.08 sq cm area to accumulate counts in eight separate sectors near the ecliptic plane. The existence of radiation above the detector background emanating from the vicinity of Saturn, upstream from the bow shock is shown. The excess counts are most plausibly attributed to neutral radiation, that is, X rays and/or neutral energetic particles. However, in connection with quantitative considerations the observed excess counts are probably not due to X-rays. It is concluded that charge exchange of energetic ions with satellite tori is an important loss mechanism at Saturn as well as at Jupiter.

Kirsch, E.↗

Theory and operation of a three-gate time-of-flight velocity analyzer

Theoretical considerations and test results are presented for a new-type velocity analyzer for incident fast neutral particles, positive ions, and negative ions. Velocity analysis is carried out by means of a pulsed, three-gate time-of-flight (TOF) technique capable of eliminating alias velocities (harmonics) to sixth order. In addition the design and operation are presented of a four-element ion lens system, with small spherical and chromatic aberrations, suitable for interfacing a large-diameter ion beam from the TOF section with a subsequent mass analyzer.

Martus, K. E.↗

Science Enabling ASICs and FEEs for the JUICE and JEO Missions

A family of science enabling radiation hard Application Specific Integrated Circuits (ASICs), Front End Electronics (FEEs) and Event Processing Systems, with flight heritage on many NASA missions, is presented. These technologies play an important role in the miniaturization of instruments -and spacecraft systems- at the same time increasing performance and reducing power. The technologies target time of flight, position sensing, and energy measurements as well as standard housekeeping and telemetry functions for particle and fields instruments, but find applications in other instrument categories too. More specifically the technologies include: the TOF chip, 1D and 2D Delay Lines with MCP detectors, for high precision fast and low power time of flight and position sensing; the Energy chip for multichannel SSD readout with time over threshold and standard voltage read out for TDC and ADC digitization; Fast multi channel read out chip with commandable thresholds; the TRIO chip for multiplexed ADC and housekeeping etc. It should be mentioned that the ASICs include basic trigger capabilities to enable random event processing in a heavy background of penetrators and UV foreground. Typical instruments include time of flight versus energy and look angle particle analyzers such as: plasma composition, energetic particle, neutral atom imaging as well as fast plasma and deltaE/E ion/electron telescopes. Flight missions include: Cassini/LEMMS, IMAGE/HENA, MESSENGER/EPPS/MLA/X-ray/MLA, STEREO, PLUTO-NH/PEPSSI/LORI, IBEX-Lo, JUNO/JEDI, RBSP/RBSPICE, MMS/HPCA/EPD, SO/SIS. Given the proven capability on heavy radiation missions such as JUNO, MMS and RBSB, as well diverse long duration missions such as MESSENGER, PLUTO and Cassini, it is expected that these technologies will play an important role in the particle and fields (at least) instruments on the upcoming JUICE and JEO missions.

Paschalidis, Nicholas↗

A laboratory study of collisional electrostatic ion cyclotron waves

The effects of neutral-particle collisions on electrostatic ion cyclotron instability are analyzed. Experiments were conducted in the Q machine of Motley (1975) with a cesium plasma in which the neutral gas pressure in the main chamber varied from about 5 microtorr-10 mtorr. The relation between electrostatic ion cyclotron wave amplitude and frequency and neutral argon pressure is examined. It is observed that over the full range of neutral pressure the frequency changes by less than 10 percent and the ion cyclotron waves continue to be excited and reach amplitudes of at least several percent at values of the neutral pressure where the ion-neutral collision frequency/ion gyrofrequency is about 0.3.

Suszcynsky, D. M.↗

Ion beam plume and efflux measurements of an 8-cm mercury ion thruster

Measurements of the ion beam plume and efflux constituents of an 8-cm mercury ion thruster have been carried out in the TRW 5 x 10 foot testing chamber. Charged components (ion beam plume) were measured with an array of movable position Faraday cups and retarding potential analyzers yielding both current density and particle energy determinations. Neutral components (ion beam efflux) were determined with a movable position ionization gauge. Measurements of the ion beam plume were performed for a thruster both with and without a sputter shield. Analysis of data in terms of normalized effluxes has been carried out and has been applied to an example calculation of efflux compatibility with a communications spacecraft.

Komatsu, G. K.↗