Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutrinoless double-beta decay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nuclear Matrix Elements for Neutrinoless Double-Beta Decay

Neutrinoless double-beta decay ($0\nu\beta\beta$) is a rare hypothesised process that, if discovered, would establish that the neutrino is Majorana, that is, it is its own antiparticle. Interpretation of experimental results relies on knowledge of nuclear matrix elements, whose large model uncertainty is the limiting factor in comparing measured (bounds on) half-lives to the neutrino mass. Nuclear effective field theory and lattice QCD have the potential to compute these matrix elements with better control over uncertainties, enhancing the discovery potential of next-generation $0\nu\beta\beta$ experiments. This work will survey various lattice QCD double-beta decay calculations and discuss their implications.

Grebe, Anthony V. [Fermilab] (ORCID:00000003103201↗

Lattice calculation of short-range contributions to neutrinoless double-beta decay 𝜋 − → 𝜋 + ⁢𝑒⁢𝑒 at physical pion mass

Neutrinoless double-beta (0⁢𝜈⁢𝛽⁢𝛽) decays provide an excellent probe for determining whether neutrinos are Dirac or Majorana fermions. The short-range matrix elements associated with the 𝜋 − → 𝜋 + ⁢𝑒⁢𝑒 process contribute at leading order in the 0⁢𝜈⁢𝛽⁢𝛽 decay channel 𝑛⁢𝑛 → 𝑝⁢𝑝⁢𝑒⁢𝑒 through pion exchange between nucleons. However, current lattice calculations show notable discrepancies in predicting these short-range contributions. To address this issue, we perform a lattice QCD calculation of the 𝜋 − → 𝜋 + ⁢𝑒⁢𝑒 matrix elements using domain wall fermion ensembles at the physical pion mass generated by the RBC/UKQCD Collaboration. To mitigate contamination from around-the-world effects, we develop a new method to reconstruct and subtract them directly from lattice data. We then perform nonperturbative renormalization in the regularization-independent symmetric momentum-subtraction scheme (RI/SMOM), using the (𝛾 𝜇 , 𝛾 𝜇 ) and ($\not{𝑞}$, $\not{𝑞}$) projectors. Compared with previous studies, this work reduces the uncertainties in the matrix elements and provides an independent cross-check that helps to reconcile the discrepancies among previous lattice calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bridging nuclear physics across energy scales: from neutrinoless double-beta decay to high-energy heavy-ion collisions

This paper exemplifies how connecting methods at disparate energy scales can illuminate fundamental questions. By demonstrating that nuclear wave function properties governing rare decay processes also influence collective behavior at extreme temperatures and densities, the authors have opened a new pathway for constraining physics beyond the Standard Model. With multiple ton-scale 0νββ experiments under construction, any method reducing NME uncertainties will directly impact our ability to interpret discoveries or constrain neutrino properties. The general principle—that collective phenomena in high-energy collisions can illuminate subtle features of many-body correlations in the colliding nuclei—may find applications across nuclear and particle physics. Furthermore, this intersection of nuclear structure theory, heavy-ion physics, and fundamental symmetry tests represents fertile ground for future discoveries in modern physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutrinoless double β decay with light sterile neutrinos: the contact terms

We study neutrinoless double-beta decay in extensions of the Standard Model that include n right-handed neutrino singlets, with masses m s below the GeV scale. Generalizing recently developed matching methods, we determine the m s dependence of the short-range nn → pp couplings that appear to leading order in the chiral effective field theory description of neutrinoless double beta decay. We focus on two scenarios, corresponding to the minimal νSM and left-right symmetric models. We illustrate the impact of our new results in the case of the νSM, showing a significant impact on the neutrinoless double-beta decay half-life when m s is in the 200–800 MeV range.

effective field theories↗

Radioactivity-in-materials lead for nEXO (Final Scientific Report)

Abstract, introduction, and summary of work completed and products produced by DOE award SC002466. Primary products were six peer-reviewed publications and two PhD theses. This award also supported the operation of an underground HPGe detector and several radioassay measurements: one in a stand alone publication in Phys. Rev. C and the others in an upcoming nEXO radioassay summary paper. The nEXO collaboration aims to demonstrate the Majorana nature of the neutrino by observing the neutrinoless double-beta decay of 136 Xe with a next-generation experiment. The University of Kentucky nEXO group (UKY) operates a world-leading ultra-low-background γ-ray spectrometer as part of the nEXO radioactive background control R&D effort. The nEXO project is a proposed ton-scale neutrinoless double-beta decay experiment. The UKY PI is leading the radioactivity content assessment for all materials required by the nEXO project. As a subset of this task, UKY is also responsible for project-wide management of all low-background γ-ray spectrometry measurements; material assays with these types of instruments, together with ICP-MS, neutron-activation-analysis, and α-spectrometry, are critical to ensuring that the nEXO project can achieve its design sensitivity

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Research in Neutrinoless Double Beta Decay

The MAJORANA DEMONSTRATOR recently concluded its search for neutrinoless double-beta decay. This technical report covers the contributions of the PI Tedeschi for the data production including the development of a run database and implementation of the file blinding scheme, as well as the analysis of the cosmic ray intensity measured by the detector veto panels.

neutrinoless double beta decay↗

Sensitivity of the CUPID experiment to $0\nu \beta \beta$ decay of 100 Mo

CUPID is a next-generation bolometric experiment to search for neutrinoless double-beta decay ($0\nu \beta \beta$ ) of 100 Mo using Li 2 MoO 4 scintillating crystals. It will operate 1596 crystals at ~10 mK in the CUORE cryostat at the Laboratori Nazionali del Gran Sasso in Italy. Each crystal will be facing two Ge-based bolometric light detectors for α rejection. We compute the discovery and the exclusion sensitivity of CUPID to $0\nu \beta \beta$ in a Frequentist and a Bayesian framework. This computation is done numerically based on pseudo-experiments. For the CUPID baseline scenario, with a background and an energy resolution of 1.0 x 10 –4 counts/keV/kg/yr and 5 keV FWHM at the Q-value, respectively, this results in a Bayesian exclusion sensitivity (90% c.i.) of $\hat{T}_{1/2} > 1.6 \times 10^{27} \ \textrm{yr}$, corresponding to the effective Majorana neutrino mass of $\hat{m}_{\beta \beta } < \ 9.6$ – 28 meV. The Frequentist discovery sensitivity (3σ ) is $\hat{T}_{1/2}= 1.0 \times 10^{27} \ \textrm{yr}$, corresponding to $\hat{m}_{\beta \beta }= \ 12$ – 36 meV.

Alfonso, K. [Virginia Polytechnic Institute and St↗

Neutrinoless Double Beta Decay of 136 Xe and Related Nuclear Structure Studies (Final Scientific Report)

The search for neutrinoless double-beta decay (0nbb) explores new physics by directly probing the unknown mass scale and possible Majorana nature of the neutrino. The nEXO experiment, one of the two leading proposed ton-scale projects in the US, has a projected sensitivity to the 136 Xe 0nbb half-life of 10 28 years. The interpretation of possible signals in this next generation of experiments would be complicated by significant variations in theoretical calculations of the nuclear matrix elements (NMEs) of the decay, and nuclear structure measurements testing those theories can help address that uncertainty. We have 136 Xe(p,n) 136 Cs reaction at TUNL to deduce the level-scheme of states in 136 Cs through which the lowest-lying 1+ state decays. We find that over 99% of such decays will proceed through at least one isomeric state with a lifetime of order 100ns, which would enable large xenon detectors to employ a delayed-coincidence technique to search for charge-exchange processes including solar neutrino interactions. We have carried out measurements at TUNL of the 134 Xe( 3 He,n) 136 Ba and 136 Xe( 3 He,n) 138 Ba reactions to low-lying 0 + states in the residuals to probe the BCS assumption for QRPA NME calculations for the initial and final nuclei in 136 Xe 0nbb. While the analyses of these reactions is not yet complete and is ongoing, our initial results indicate tension with the BCS assumption. We have assembled a thermosyphon cooling R&D system for nEXO which has demonstrated up to 500 W of cooling in vacuum. We have developed a simple thermosyphon cooling simulation for nEXO and planned laboratory tests with the R&D system to benchmark it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rare multinucleon decays with the full data sets of the M AJORANA D EMONSTRATOR

The M AJORANA D EMONSTRATOR was an ultra-low-background experiment designed for neutrinoless double-beta decay (0⁢𝜈⁢𝛽⁢𝛽) investigation in 76 Ge . Located at the Sanford Underground Research Facility in Lead, South Dakota, the D EMONSTRATOR utilized modular high-purity Ge detector arrays within shielded vacuum cryostats, operating deep underground. The arrays, with a capacity of up to 40.4 kg (27.2 kg enriched to ∼88% in 76 Ge ), have accumulated the full data set, totaling 64.5 kg yr of enriched active exposure and 27.4 kg yr of exposure for natural detectors. Here, our updated search improves previously explored three-nucleon decay modes in Ge isotopes, setting new partial lifetime limits of 1.83 × 10 26 yr (90% confidence level) for 76 Ge (𝑝⁢𝑝⁢𝑝) → 73 Cu 𝑒 + ⁢𝜋 + ⁢𝜋 + and 76 Ge (𝑝⁢𝑝⁢𝑛) → 73 Zn 𝑒 + ⁢𝜋 + . The partial lifetime limit for the fully inclusive triproton decay mode of 76 Ge is found to be 2.1×10 25 yr. Furthermore, we have updated limits for corresponding multinucleon decays.

baryon & lepton number symmetries↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

Constraints on lepton number violation with the 2 tonne · year CUORE dataset

Matter-antimatter asymmetry underlines the incompleteness of the current understanding of particle physics. Neutrinoless double-beta decay (0νββ) may help explain this asymmetry while unveiling the Majorana nature of the neutrino. The CUORE (Cryogenic Underground Observatory for Rare Events) experiment searches for 0νββ of 130 Te using a tonne-scale cryogenic calorimeter operated at milli-kelvin temperatures. We report no evidence of 0νββ and place a lower limit on the half-life of T 1/2 > 3.5 × 10 25 years (90% credibility interval) with over 2 tonne·years of TeO 2 exposure. Finally, the tools and techniques developed for this result and the 5-year stable operation of nearly 1000 detectors demonstrate crucial infrastructure for future-generation experiments capable of searching for 0νββ across multiple isotopes.

Adams, D. Q. [Department of Physics and Astronomy,↗

Ion transport on phased radiofrequency carpets in xenon gas

We present the design and performance of a four-phased radiofrequency (RF) carpet system for ion transport between 200–600 mbar, significantly higher than previously demonstrated RF carpet applications. The RF carpet, designed with a 160 μm pitch, is applied to the lateral collection of ions in xenon at pressures up to 600 mbar. We demonstrate transport efficiency of caesium ions across varying pressures, and compare with microscopic simulations made in the SIMION package. The novel use of an N-phased RF carpet can achieve ion levitation and controlled lateral motion in a denser environment than is typical for RF ion transport in gases. This feature makes such carpets strong candidates for ion transport to single ion sensors envisaged for future neutrinoless double-beta decay experiments in xenon gas.

ion transport↗

A gravity-based mounting approach for large-scale cryogenic calorimeter arrays

Cryogenic calorimeters are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of 100 Mo. The CUPID collaboration proposed an innovative approach to assembling cryogenic calorimeters in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of cryogenic calorimeters and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 Li 2 MoO 4 crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than ±0.5 mK at 10 mK, (ii) a good energy resolution of Li 2 MoO 4 cryogenic calorimeters, (6.6 ± 2.2) keV FWHM at 2615 keV, and (iii) a Li 2 MoO 4 light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration of Sub-Percent Energy Resolution in the NEXT-100 Detector

NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to approximately 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ($ββ0ν$) of Xe-136. The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ($Q_{ββ}$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a Th-228 source, demonstrating linear response and an energy resolution of $(0.90 \pm 0.02)$% FWHM at the Tl-208 photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $R(Q_{ββ})$ = $(0.93 \pm 0.02)$% FWHM, confirming the detector's capability for precision energy measurement in the search for $ββ0ν$.

Pérez Maneiro, M. [Santiago de Compostela U., IGFA↗

Characterization of the First Prototype of the L1K65n Differential-Output Charge-Sensitive Preamplifier ASIC for High-Performance, Low-Background HPGe Detector Readout

Next-generation neutrinoless double-beta (0νββ) decay searches require a large detector/isotope mass and very low radioactive backgrounds. The upcoming LEGEND-1000 experiment (Large Enriched Germanium Experiment for Neutrinoless double-beta Decay) constitute a ton-scale array of several hundred high-purity germanium (HPGe) detectors enriched in 76Ge, the isotope of interest. It aims to reach a sensitivity beyond 10 28 years on the 0νββ decay half-life of 76Ge, necessitating an order of magnitude reduction in background with respect to the state of the art. This will require the implementation of a dedicated application specific integrated circuit (ASIC) preamplifier that will significantly lower background contribution compared to the conventional low-mass front end (LMFE) employed in the Majorana Demonstrator and LEGEND-200 experiments while maintaining or improving energy resolution and other performance parameters. Features include a high (9 MeV) dynamic range with noise low enough to achieve a trigger threshold of <1 keV, a single power supply to reduce background-inducing cabling, and a differential output to maintain signal integrity over several meters of transmission line. The chip would be optimized to operate in liquid argon (87 K) and be able to do so reliably for ten years. Following on from an earlier 180-nm prototype, we have developed a differential-output charge-sensitive preamplifier ASIC fabricated in a 65-nm process, 1×2 mm in size, that addresses these needs. Here, we present recent results from the successful testing and characterization of the first version of this device.

ASIC↗

First Results on the Search for Lepton Number Violating Neutrinoless Double-𝛽 Decay with the LEGEND-200 Experiment

The LEGEND Collaboration is searching for neutrinoless double-beta (0⁢𝜈⁢𝛽⁢𝛽) decay by operating high-purity germanium detectors enriched in 76 Ge in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0⁢𝜈⁢𝛽⁢𝛽 decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5$^{+0.3}_{−0.2}$ ⁢cts/(keV ton yr) in the 0⁢𝜈⁢𝛽⁢𝛽 decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 ×10 26 yr on the half-life of 0⁢𝜈⁢𝛽⁢𝛽 decay, reveals no evidence for a signal and sets a new observed lower limit at 𝑇$^{⁢0𝜈}_{1/2}$ > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range 𝑚 𝛽⁢𝛽 < 75–200 meV, depending on the adopted nuclear matrix element.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Majorana Neutrinos with the Complete KamLAND-Zen Dataset

We present a search for neutrinoless double-beta (0⁢𝜈⁢𝛽⁢𝛽) decay of 136 Xe using the full KamLAND-Zen 800 dataset with 745 kg of enriched xenon, corresponding to an exposure of 2.1 ton yr of 136 Xe. This updated search benefits from a more than twofold increase in exposure, recovery of photo-sensor gain, and reduced background from muon-induced spallation of xenon. Combining with the search in the previous KamLAND-Zen phase, we obtain a lower limit for the 0⁢𝜈⁢𝛽⁢𝛽 decay halflife of 𝑇$^{0⁢𝜈}_{1/2}$ >3.8 ×10 26 yr at 90% CL, a factor of 1.7 improvement over the previous limit. The corresponding upper limits on the effective Majorana neutrino mass are in the range 28–122 meV using phenomenological nuclear matrix element calculations.

Abe, S. [Tohoku University] (ORCID:000000022110513↗