Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

In-depth evaluation of 252 Cf absolute calibration by passive neutron correlation counting method

252 Cf neutron sources are particularly convenient, and therefore widely used, to characterize and calibrate many kinds of neutron detectors for both scientific and technological applications. An emerging interest is the use of 252 Cf to calibrate neutron correlation counters for the verification and assay of Pu-items as part of the international effort to safeguard nuclear materials. Passive neutron correlation counting (PNCC) methods, combined with knowledge of the fission neutron multiplicity distribution, can be used as an absolute technique to determine the neutron emission rate of 252 Cf sources. This means that common equipment used by the safeguards community can, in principle, be used to self-certify, to high accuracy, the strength of physically small 252 Cf sealed sources for use in calibration. This is the first step in using 252Cf in place of extensive Pu reference materials for experimental calibration by the safeguards community. The theoretical foundation is already clear but the present work presents the first systematic attempt at demonstrating the practical utility of the concept across a variety of typical instruments. We compare four emission rate estimators for four detector configurations on a common source previously certified by the MnSO 4 -bath technique. We find that the estimator based on the singles to doubles rate ratio provides consistent and precise results across all of the instruments and that these agree with the MnSO 4 -bath technique within combined uncertainties. This success suggests that the absolute PNCC method could become a technically defensible and commonly used, method capable of sub 1% accuracy for routine calibration work.

74 ATOMIC AND MOLECULAR PHYSICS↗

Two neutron correlations in photo-fission

A large body of experimental work has established the strong kinematical correlation between fission fragments and fission neutrons. Here, we report on the progress of investigations of the potential for strong two neutron correlations arising from the nearly back-to-back nature of the two fission fragments that emit these neutrons in the photo-fission process. In initial measurements, a pulsed electron linear accelerator was used to generate bremsstrahlung photons that impinged upon an actinide target, and the energy and opening angle distributions of coincident neutrons were measured using a large acceptance neutron detector array. A planned comprehensive set of measurements of two neutron correlations in the photo-fission of actinides is expected to shed light on several fundamental aspects of the fission process including the multiplicity distributions associated with the light and heavy fission fragments, the nuclear temperatures of the fission fragments, and the mass distribution of the fission fragments as a function of energy released. In addition to these measurements providing important nuclear data, the unique kinematics of fission and the resulting two neutron correlations have the potential to be the basis for a new tool to detect fissionable materials. A key technical challenge of this program arises from the need to perform coincidence measurements with a low duty factor, pulsed electron accelerator. This has motivated the construction of a large acceptance neutron detector array, and the development of data analysis techniques to directly measure uncorrelated two neutron backgrounds.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Estimating the Effective System Dead Time Parameter for Correlated Neutron Counting

We present that neutron time correlation analysis is one of the main technical nuclear safeguards techniques used to verify declarations of, or to independently assay, special nuclear materials. Quantitative information is generally extracted from the neutron-event pulse train, collected from moderated assemblies of 3 He proportional counters, in the form of correlated count rates that are derived from event-triggered coincidence gates. These count rates, most commonly referred to as singles, doubles and triples rates etc., when extracted using shift-register autocorrelation logic, are related to the reduced factorial moments of the time correlated clusters of neutrons emerging from the measurement items. Correcting these various rates for dead time losses has received considerable attention recently. The dead time losses for the higher moments in particular, and especially for large mass (high rate and highly multiplying) items, can be significant. Consequently, even in thoughtfully designed systems, accurate dead time treatments are needed if biased mass determinations are to be avoided. In support of this effort, in this paper we discuss a new approach to experimentally estimate the effective system dead time of neutron coincidence counting systems. It involves counting a random neutron source (e.g. AmLi is a good approximation to a source without correlated emission) and relating the second and higher moments of the neutron number distribution recorded in random triggered interrogation coincidence gates to the effective value of dead time parameter. We develop the theoretical basis of the method and apply it to the Oak Ridge Large Volume Active Well Coincidence Counter using sealed AmLi radionuclide neutron sources and standard multiplicity shift register electronics. The method is simple to apply compared to the predominant present approach which involves using a set of 252 Cf sources of wide emission rate, it gives excellent precision in a conveniently short time, and it yields consistent results as a function of the order of the moment used to extract the dead time parameter. In addition, this latter observation is reassuring in that it suggests the assumptions underpinning the theoretical analysis are fit for practical application purposes. However, we found that the effective dead time parameter obtained is not constant, as might be expected for a parameter that in the dead time model is characteristic of the detector system, but rather, varies systematically with gate width.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Experimental validation of scintillator detector response to correlated neutrons with MCNP and associated packages

Time, energy, and angle correlated neutrons are emitted in nuclear fission. New, physics-based fission event generators that capture these correlations have been incorporated into MCNP6.2 because correlations can impact nuclear non-proliferation and safeguards systems response. DRiFT is a detector response code that takes MCNP outputs and reproduces laboratory analogous detector quantities. Previous work has compared DRiFT to single detector experiment data and has discussed recent updates to DRiFT specific to correlated fission experiments. In this work, we demonstrate a validation of recent updates to DRiFT for organic scintillator response in correlated fission neutron experiments using a 252Cf source. Furthermore, outputs from MCNP with the FREYA fission event generator were post-processed with DRiFT and compared to experiment data. Simulation and experiment results are in reasonably good agreement for multiple correlated neutron quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron-Neutron Correlations in the Photofission of 238U

Background: In the fission of actinides, the nearly back-to-back motion of the fission fragments has a strong effect on the kinematics of fission neutrons. This leads to a favoring of opening angles near 0? and 180? in the neutron-neutron (n-n) opening angle distributions of correlated neutron pairs from the same fission event. Purpose: To measure the n-n opening angle and energy correlations in the photofission of 238U. As of this writing, measurements of correlated n-n opening angle distributions have been reported only for the spontaneous and neutron-induced fission of actinides. This work is the first to report such a measurement using photofission and will provide useful experimental input for photofission models used in codes such as MCNP and FREYA. Method: Fission is induced using bremsstrahlung photons produced via a low duty factor, pulsed, linear electron accelerator. The bremsstrahlung photon beam impinges upon a 238U target that is surrounded by a large neutron scintillation detection system capable of measuring particle position and time of flight, from which n-n opening angle and energy are measured. Neutron-neutron angular correlations are determined by taking the ratio between a correlated neutron distribution and an uncorrelated neutron distribution formed by the pairing of neutrons produced during different beam pulses. This analysis technique greatly diminishes effects due to detector efficiencies, acceptance, and experimental drifts. Results: The angular correlation of neutrons from the photofission of 238U shows a high dependence on neutron energy as well as a dependence on the angle of the emitted neutrons with respect to the incoming photon beam. Angular correlations were also measured using neutrons from the spontaneous fission of 252Cf, showing good agreement with past measurements. Conclusions: The measured angular correlations reflect the underlying back-to-back nature of the fission fragments. An anomalous decline in n-n yield was observed for opening angles near 180? for 238U.

Burggraf, Jeff↗

Possibility of Studying Neutron–Neutron Correlations in Halo Nuclei

An experimental investigation of the reaction of core pickup from {sup 6}He and {sup 11}Li two-neutronhalo nuclei is proposed. In such experiments, neutron–neutron correlations in a halo nucleus will be assessed on the basis of the energy of a neutron–neutron quasibound state. A detailed kinematical simulation of the reaction {sup 6}He + {sup 2}H → {sup 6}Li + (nn) →{sup 6} Li + n + n is performed. It is shown that the energy of the quasibound state in question can determined from the shape of the energy spectrum of neutrons originating from the breakup of this state. In the proposed exclusive experiment, a beam of {sup 6}He ({sup 11}Li) nuclei with an energy of about 5 to 10 MeV per nucleon interacts with a deuterated-polyethylene target. This will permit detecting charged particles ({sup 6}Li and {sup 11}Be) and a neutron. On the basis of determining the energy of the neutron–neutron quasibound state, it will become possible to estimate the effective attraction between the valence neutrons in the field of the third particle (core).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gamma Neutron Correlated Noise of the EUCLID Critical Experiment

In this work, we present results from gamma noise measurements of a fast plutonium critical system for the first time. These results are compared to the more traditional method of neutron noise. Additionally, we investigate cross correlations of neutron and gamma signals and discuss the advantages of doing so.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Exact isovector pairing in a shell-model framework: Role of proton-neutron correlations in isobaric analog states

Here, we utilize a nuclear shell model Hamiltonian with only two adjustable parameters to generate, for the first time, exact solutions for pairing correlations for light to medium-mass nuclei, including the challenging proton-neutron pairs, while also identifying the primary physics involved. In addition to single-particle energy and Coulomb potential terms, the shell model Hamiltonian consists of an isovector T = 1 pairing interaction and an average proton-neutron isoscalar T = 0 interaction, where the T = 0 term describes the average interaction between nonpaired protons and neutrons. This Hamiltonian is exactly solvable, where, utilizing three to seven single-particle energy levels, we reproduce experimental data for 0 + state energies for isotopes with mass A = 10 through A = 62 exceptionally well including isotopes from He to Ge. Additionally, we isolate effects due to like-particle and proton-neutron pairing, provide estimates for the total and proton-neutron pairing gaps, and reproduce N (neutron) = Z (proton) irregularity. These results provide a further understanding for the key role of proton-neutron pairing correlations in nuclei, which is especially important for waiting-point nuclei on the $\mathcal{rp}$ path of nucleosynthesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

4D imaging of lithium-batteries using correlative neutron and X-ray tomography with a virtual unrolling technique

The temporally and spatially resolved tracking of lithium intercalation and electrode degradation processes are crucial for detecting and understanding performance losses during the operation of lithium-batteries. Here, high-throughput X-ray computed tomography has enabled the identification of mechanical degradation processes in a commercial Li/MnO 2 primary battery and the indirect tracking of lithium diffusion; furthermore, complementary neutron computed tomography has identified the direct lithium diffusion process and the electrode wetting by the electrolyte. Virtual electrode unrolling techniques provide a deeper view inside the electrode layers and are used to detect minor fluctuations which are difficult to observe using conventional three dimensional rendering tools. Moreover, the 'unrolling' provides a platform for correlating multi-modal image data which is expected to find wider application in battery science and engineering to study diverse effects e.g. electrode degradation or lithium diffusion blocking during battery cycling.

25 ENERGY STORAGE↗

Erratum to “Estimating the effective system dead time parameter for correlated neutron counting” [Nucl. Instrum. Methods Phys. Res. A 871 (2017) 154–160]

The expressions given for φ, the ratio of effective system dead time to gate width, are wrong for the case of the third and fourth order forms because the simple square root is used when the 3rd and 4th roots, respectively, are required. We failed to notice during proof reading that this change from the submitted manuscript had crept in. The correct form should, however, be clear from the steps of the derivations outlined in the text; and so we hope our mistake has not misled anyone.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical basis for the use of a correlated neutron source in the uranium neutron coincidence collar

Active neutron coincidence systems are commonly used by international inspectorates to verify a material balance across the various stages of the nuclear fuel cycle. The Uranium Neutron Coincidence Collar (UNCL) is one such instrument; it is used to measure the linear density of 235 U (g 235 U/cm of active length in assembly) in fresh light water reactor fuel in nuclear fuel fabrication facilities. The UNCL and other active neutron interrogation detectors have historically relied on americium lithium ( 241 AmLi) sources to induce fission within the sample in question. Californium-252 is under consideration as a possible alternative to the traditional 241 AmLi source. Finally, this work relied upon a combination of experiments and Monte Carlo simulations to demonstrate the technical basis for the replacement of 241 AmLi sources with 252 Cf sources by evaluating the statistical uncertainty in the measurements incurred by each source and assessing the penetrability of neutrons from each source for the UNCL.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Correlated Neutron Interrogation Source in the Active Well [Slides]

The Active Well Coincidence Counter (AWCC) is a technology developed by Los Alamos National Laboratories for the use of non-destructive assay of Uranium materials for international nuclear inspectorates such as the IAEA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Neutron Detection Third Order Time Correlation

Neutron noise experiments on fissile materials are used to get information such as reactivity, fissile mass, neutron sources, prompt neutron lifetime. One of the more popular methods is based on correlated moments of the neutron counts distribution. The second correlated moment method originally proposed by Feynman was extended to the third order. In this paper we present the application of the third order correlation moments method to SILENE reactor measurements. The third order correlation moments method has been applied to analyse time list mode - subcritical measurements on SILENE reactor in order to evaluate the system subcriticality, The multiplication coefficient is obtained with large statistical uncertainties, but remains consistent with MCNP calculations. To reduce the experimental uncertainties longer measurement time and higher detector efficiency should be necessary. The systematic errors coming from the fission neutron data (moments of the fission neutron distributions) and point model formulas should also be investigated. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Detailed Investigations of Neutron–Neutron Angular Correlations in Slow-Neutron-Induced Fission of {sup 233}U, {sup 235}U, and {sup 239}Pu

An experiment devoted to studying neutron–neutron angular correlations in the slow-neutroninduced fission of {sup 233}U, {sup 235}U and {sup 239}Pu nuclei was performed. The experimentally determined angular dependence of the number of neutron–neutron coincidences was compared with the results of a Monte Carlo simulation for various values of the neutron-detection threshold in the range between 490 and 2080 keV. It was found that the experimental angular distributions in question can be described well under the assumption that 2% to 5% of all prompt fission neutrons are emitted isotropically in the laboratory frame. Probably, such neutrons can be interpreted as so-called scission neutrons directly associated with the nuclear-rupture instant. Energy distributions of this component were also obtained from the present analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗