Solid state neutron dosimeter for space applications

Personnel engaged in space flight are exposed to significant flux of high energy neutrons arising from both primary and secondary sources of ionizing radiation. Presently, there exist no compact neutron sensor capable of being integrated in a flight instrument to provide real time measurement of this radiation flux. A proposal was made to construct such an instrument using special PIN silicon diode which has the property of being insensitive to the other forms of ionizing radiation. Studies were performed to determine the design and construction of a better reading system to allow the PIN diode to be read with high precision. The physics of the device was studied, especially with respect to those factors which affect the sensitivity and reproducibility of the neutron response. This information was then used to develop methods to achieve high sensitivity at low neutron doses. The feasibility was shown of enhancing the PIN diode sensitivity to make possible the measurement of the low doses of neutrons encountered in space flights. The new PIN diode will make possible the development of a very compact, accurate, personal neutron dosimeter.

Entine, Gerald↗

Tungsten thermal neutron dosimeter

Tungsten-185 activity, which is produced by neutron activation of tungsten-184, determines thermal neutron flux. Radiochemical separation methods and counting techniques for irradiated tungsten provide accurate determination of the radiation exposure.

Ball, L. L.↗

Solid state neutron dosimeter for space applications

One of the most important contributions to the radiation exposure of astronauts engaged in space flight is the significant flux of high energy neutrons arising from both primary and secondary sources of ionizing radiation. Under NASA sponsorship, we are developing a solid state neutron sensor capable of being incorporated into a very compact, flight instrument to provide high quality real time measurement of this important radiation flux. The dosimeter uses a special, high neutron sensitivity, PIN diode that is insensitive to the other forms of ionizing radiation. The dosimeter will have the ability to measure and record neutron dose over a range of 50 microgray to tens of milligrays (5 millirads to several rads) over a flight of up to 30 days. The performance characteristics of the PIN diode with a detailed description of the overall dosimeter is presented.

Nagarkar, V.↗

Determination of energy correction coefficient for neutron albedo dosimeter. Three approaches

To accurately determine dose, albedo TLD dosimeters require application of a neutron energy correction factor (NECF). Here, in this paper, the results from three different methods were used to determine NECFs. In the first method, NECF values were calculated as a ratio of the known “conventional true” dose and the neutron dose reported by albedo dosimeter(s) irradiated on a phantom. The results from this direct method were utilized for verification of two other methods. The second method used a specially designed device called the Neutron Area Monitor (NAM) model 5. The third method of NECF determination was based on the response of a BF 3 tube under different levels of moderation. The results of this work showed that the Navy-developed Neutron Area Monitor (NAM) model 5 measures NECF values correctly when irradiated with 252 Cf (bare and D 2 O-moderated). This was an important result, because it validated the use of the NAM-5 in nuclear power and marine propulsion reactors, as their neutron energy spectrum is approximated by the field of a Cadmium-coated 30 cm diameter steel sphere of D 2 O moderated 252 Cf. In the case of a broad neutron energy spectrum the 6 Li response to the small amount of slow neutrons outweighs its response to the fast neutrons overwhelmingly responsible for the neutron dose rate. Based on the obtained results we can conclude that NAM-5 provides correct NECF determination if the fraction of slow neutrons in the neutron dose rate is more than 20%. A satisfactory correlation between the NECF determined by NAM-5 and the multi-moderated BF3 tube method was observed, but the multi-moderated BF 3 tube values were ~30% lower than those obtained by the NAM-5 at the same locations for broader neutron energy spectrum locations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrolytic Co-deposition Neutron Production Evaluation

Co-deposition electrochemical cells are a simple means to examine novel nuclear reactions. In this study, palladium and deuterium atoms were co-deposited on a cathode at stoichiometric densities, forming dendritic morphologies. Bubble detector neutron dosimeters were used to measure equivalent dose levels during electrolytic deposition. Standard configuration cells expected to produce excess neutrons were denoted as experimental cells and contained an electrolyte consisting of palladium(II) chloride, lithium chloride, and heavy water. The control cells used copper(II) chloride, lithium chloride, and heavy water electrolyte. Experimental and control cells were supplied current, increasing from 0.1 to 100.0 mA over a period of 20 days. For test days 9 through 20, the standard configuration experimental cells exhibited significantly higher average neutron radiation than the controls at a 99% confidence level. Alternative configurations involving more increasing current over a shortened time scale, substitutions of water in place of heavy water or potassium chloride for lithium chloride, as well as inclusion of depleted uranium near the cell cathodes all resulted in inconclusive evidence for promoting neutron production.

neutron↗

Fabrication and Testing of Micro Flux Monitors in the High Flux Isotope Reactor

Neutron dosimetry is a critical technique to measure the neutron flux, fluence, and energy spectrum of nuclear reactors and can be used to indicate fuel reloading, high-power operations, or changes in cycle length. This work presents results of a novel device named the micro flux monitor, which is a miniaturized neutron dosimeter made from small quantities (100s of nanograms) of Ti, Al, Ni, and Au metals deposited on Si and high-purity fused silica substrates using standard semiconductor fabrication techniques. Approximately 1,250 of these devices were produced, and 40 were irradiated in the pneumatic tube facility of the Neutron Activation Analysis Laboratory at the High Flux Isotope Reactor. Testing demonstrated that dosimeter metals can be deposited predictably and repeatedly in multiple geometries, including as quick response (QR) codes. Neutron flux measurements with these devices were within 3% of measurements made using standard flux monitors, demonstrating the efficacy of these devices. Devices were also tested at 500°C under a N2 atmosphere and showed minimal degradation, suggesting they could be deployed for neutron dosimetry measurements in high-temperature advanced reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spectrum Unfolding with the MC-15

The Multiplicity Counter 15 tube detector or MC-15 is an optimized detector designed for use in the field. It is composed of 15 3 He tubes embedded in high density polyethylene (HDPE). Recent work has explored expanding the use of the MC-15 beyond multiplicity counting to neutron dosimetry applications. Knowledge of the neutron energy spectrum information is required to use a detector as a neutron dosimeter. The MC-15 tube layout is shown in Figure 1. The unique layout makes it possible to use the detector for neutron spectroscopy via spectrum unfolding. Spectrum unfolding requires (1) energy dependence of the detector response, (2) a detector response matrix that precisely quantifies the response to mono-energetic neutrons, (3) an initial guess spectrum, (4) an unfolding algorithm, and (5) measured data (counts in the case of the MC-15). An energy dependent detector response matrix (DRM) can be constructed by considering either each of the three rows of 3 He tubes as a distinct detector or each individual tube as a distinct detector. The HDPE separating the 3 He in the MC-15 provides the distinct energy dependent response for the rows and individual tubes. In this report we detail the development of detector response matrices for the MC-15 and the application of the Los Alamos Unfolding Code (LUC) to both simulated and measured data. Three MC-15 orientations were studied: (1) standard orientation with the MC-15 front facing the source, (2) standard orientation with Cd sheet, (3) 90° orientation with the side of the MC-15 facing the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of neutron dosimetry capabilities with the MC-15 portable multiplicity counter

This work proposes a preliminary neutron dose rate estimation method for a neutron multiplicity detector through measurement- and simulation-based analyses. Uncharacterized neutron-emitting sources may be encountered in situations such as nuclear emergency response, safeguards, and treaty verification. These circumstances may present irradiation risk to personnel conducting field assay, search, and characterization measurements. It is therefore of interest to provide a field neutron dosimetry capability with the existing neutron multiplicity counting (NMC) capabilities. To date, no commercially-available neutron detection systems are capable of both accurate NMC and real-time neutron dosimetry. This work will focus on estimating dose rate using input from a single fielded NMC called the MC-15. The energy-dependent neutron detection efficiency response of the MC-15 was quantified in monoenergetic neutron simulations and evaluated in response to two neutron-emitting sources and to a polyethylene-moderated source. The results were compared to existing neutron dosimeters and established the proof of concept for further investigation of the MC-15 for dose estimation. Measurement results were also replicated in simulations; additional simulations were then conducted to expand upon the limited empirical data. The initial empirical results provided a conversion factor appropriate for use when measuring 252 Cf neutrons that is independent of polyethylene shielding presence and thickness. The simulated data sets were then used to evaluate a fit equation allowing estimation of the neutron dose rate for less restricted geometric configurations and dependent only on the distance between the source and the detector. Additionally, the energy dependence of the efficiency response indicates that further empirical evaluations could provide energy-dependent conversion factors for broader neutron dosimetry capabilities with a wider range of neutron-emitting sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fading study of Harshaw LiF:Mg,Ti thermoluminescence dosimeters exposed to neutron doses

Sensitivity and signal fading were tested in Harshaw LiF:Mg,Ti thermoluminescence dosimeters (TLDs) exposed to neutron and beta/photons doses. A significant difference in the signal fading rate was observed for TLDs exposed to neutrons compared with TLDs exposed to betas. This difference may have been related to differences in glow curves for dosimeters exposed to different beams and to differences in glow curve evolution after exposure. A fading-correction algorithm was developed to correct the cumulative sensitivity + signal fading of TL doses for the fading time t using the formulae: y = 0.147∗exp(-t/4.36) + 0.308∗exp(-t/34.1) + 0.73 for neutrons, and: y = 0.132∗exp(-t/10.72) + 0.174∗exp(-t/31.5) + 0.8 for betas/photons. The formula was validated using the dose recovery test, where the average deviation of fading-corrected doses from delivery doses was within 1%. In conclusion, the proposed fading-correction approaches may significantly improve the accuracy of Harshaw TL dosimetry with LiF:Mg,Ti cards for both neutron and beta/gamma irradiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Practical new method of measuring thermal-neutron fluence

Thermoluminescence dosimeter technique measures thermal-neutron fluence by encapsulating lithium flouride phosphor powder and exposing it to a neutron environment. The capsule is heated in a dosimeter reader, which results in light emission proportional to the neutron fluence.

Siebold, J. R.↗

Fission foil detector calibrations with high energy protons

Fission foil detectors (FFD's) are passive devices composed of heavy metal foils in contact with muscovite mica films. The heavy metal nuclei have significant cross sections for fission when irradiated with neutrons and protons. Each isotope is characterized by threshold energies for the fission reactions and particular energy-dependent cross sections. In the FFD's, fission fragments produced by the reactions are emitted from the foils and create latent particle tracks in the adjacent mica films. When the films are processed surface tracks are formed which can be optically counted. The track densities are indications of the fluences and spectra of neutrons and/or protons. In the past, detection efficiencies have been calculated using the low energy neutron calibrated dosimeters and published fission cross sections for neutrons and protons. The problem is that the addition of a large kinetic energy to the (n,nucleus) or (p,nucleus) reaction could increase the energies and ranges of emitted fission fragments and increase the detector sensitivity as compared with lower energy neutron calibrations. High energy calibrations are the only method of resolving the uncertainties in detector efficiencies. At high energies, either proton or neutron calibrations are sufficient since the cross section data show that the proton and neutron fission cross sections are approximately equal. High energy proton beams have been utilized (1.8 and 4.9 GeV, 80 and 140 MeV) for measuring the tracks of fission fragments emitted backward and forward.

Benton, E. V.↗

Nuclear Data Sheets for A=64

The evaluated experimental data are presented and evaluated for 13 known nuclides of mass 64 (Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se). For each nuclide, the best values combining all available data are recommended for spectroscopic properties. No excited states have been identified in 64 Ti, 64 As, and 64 Se. Only one excited state in 64 V as an isomer, and three in 64 Cr have been identified. Data for excited states in 64 Mn, 64 Fe, and 64 Co remain limited. 64 Ni, 64 Cu, and 64 Zn are the most studied nuclides through various reactions and decays, followed by 64 Ga and 64 Ge. In the opinion of the evaluators, there are several incomplete or discrepant aspects of the high-spin portion of the level scheme for 64 Zn above ≈5 MeV excitation which need to be resolved in further experiments using large γ-detector arrays. The decay schemes of 64 Ti β - , 64 As ε and 64 Se ε are unknown, while very little information is available for 64 V β - and 64 Cr β - . The decay schemes of 64 Mn β - , 64 Fe β - , 64 Co β - and 64Ge ε are somewhat better known, but still considered incomplete by evaluators. The decay scheme of 64 Ga ε decay is known in detail, however there is the possibility of additional levels populated above 4713 keV, as the Q(ε) value is 7171 keV. The β - , β + and ε decay modes of 64 Cu are well known, as this radionuclide is of great importance in applications, for example, as a dosimeter for neutron flux determination in nuclear reactors, and as a radiopharmaceutical for positron emission tomography (PET). This work supersedes earlier full evaluations of A=64 by 2007Si04, 1996Si12, 1991Si03, 1979Ha35 and 1974Au04.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation measuring instrumentation

Four radiation measuring instruments were developed. These are: (1) improved detector probe, (2) neutron spectrometer--dosimeter, (3) portable ultraviolet spectro-radiometer; and (4) pocket ionization chamber radiation dosimeter. A brief description of each of these devices is presented.

Piltingsrud, H. V.↗

High LET, passive space radiation dosimetry and spectrometry

The development of high linear energy transfer (LET), passive radiation dosimetry and spectrometry is needed for the purpose of accurate determination of equivalent doses and assessment of health risks to astronauts on long duration missions. Progress in the following research areas is summerized: intercomparisons of cosmic ray equivalent dose and LET spectra measurements between STS missions and between astronauts; increases LET spectra measurement accuracy with ATAS; space radiation measurements for intercomparisons of passive (PNTD, TLD, TRND, Emulsion) and active (TEPC, RME-111) dosimeters; interaction of cosmic ray particles with nuclei in matter; radiation measurements after long duration space exposures; ground based dosimeter calibrations; neutron detector calibrations; radiation measurements on Soviet/Russian spacecraft; space radiation measurements under thin shielding; and space radiation.

Benton, E. V.↗

Instrumentation for the In-Core Real-Time Mechanical Testing of Structural Materials (INCREASE) Project

Idaho National Laboratory (INL), in collaboration with the Electric Power Research Institute (EPRI), the Nuclear Regulatory Commission (NRC), the French Atomic and Alternative Energies Commission (CEA), the Joint Research Center (JRC), the Nuclear Research and Consultancy Group (NRG), and the Research Center Rez (CVR), started a Joint Experimental Program (JEEP) project that operates within the Nuclear Energy Agency’s Framework for Irradiation Experiments (FIDES II) program in order to develop capabilities for the in-core real-time mechanical testing of structural materials. This effort will focus on designing a shared capsule capable of housing a variety of in-core mechanical testing instrumentation allowing enhanced experiments for the material science community. The outcome of the project would be high-priority, stress relaxation data for stainless-steel-based materials provided by EPRI and CEA. Stress relaxation is a major phenomenon that contributes to material degradation in nuclear reactor components. Currently, nuclear material stress relaxation is assessed both before and after irradiation, using complex and costly post-irradiation examination (PIE) activities. In-situ data would support the development of precision modeling and simulation of this degradation phenomena and would provide validation and benchmarking for existing models using the PIE data. As part of the U.S. Department of Energy Advanced Sensor and Instrumentation (ASI) program, INL has fabricated and tested out-of-core mechanical test instrumentation. This instrumentation was designed for easy adaptation to the irradiation capsule proposed under this JEEP, and can be deployed to measure real-time stress relaxation under pressurized-water reactor (PWR) conditions. This initial effort will partially serve to replace the testing capabilities lost because of shutting down the Halden Boiling Water Reactor (HBWR). The project would provide these capabilities to the international community via a shared capsule design that is easily adaptable to additional material test reactors. The design features will incorporate expansion to PWR and non-light-water reactor (LWR) environments that will be developed in future work. The capsule and instrumentation will be demonstrated in the Massachusetts Institute of Technology Reactor (MITR) for phase I and the Petten High Flux Reactor (HFR) for phase II irradiations to deliver real-time stress relaxation data on high priority stainless steel structural materials.

36 MATERIALS SCIENCE↗