SEARCH · Search NASA
Results for “neutron multiplicity”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Performance Characterization of FB-Line Neutron Multiplicity Counter and Large Neutron Multiplicity Counter
Savanah River National Laboratory’s (SRNL) Nuclear Measurements group was tasked with characterizing the performance of two neutron multiplicity counters located at SRNL. Characterization measurements were made to determine the gate width, pre-delay, deadtime parameters, triples and doubles gate fractions, detector efficiency, and operating high voltage for the Large Neutron Multiplicity Counter (LNMC) and the FB Line Neutron Multiplicity Counter (FBLNMC). The parameters were determined, shown below, and were, as to be expected, slightly different than the previous calibrations, which were performed over 20 years ago. Several Pu samples were measured to validate the characterizations of the FBLNMC and LNMC. The measurements determined the sample Pu-240 mass within <2% deviation for the pure plutonium samples and ~8% for the mixed oxide sample. The pure Pu samples had significantly better accuracy compared with the impure mixed oxide sample due to the lack of induced fission or alpha,n neutrons from impurities. Overall, the characterization of the neutron multiplicity counters, and the determination of their operability has been completed successfully.
Expansion of the surrogate method to measure the prompt fission neutron multiplicity for Pu 241 [Prompt Fission Neutron Multiplicity for Pu-241 using the Surrogate Method]
Fission neutron multiplicity data are imperative for nuclear models that support criticality safety, nuclear nonproliferation, and stockpile stewardship. This work presents the first experimental measurement to determine the average neutron multiplicity ($\bar{ν}$) and the neutron multiplicity distribution using a surrogate reaction. 241 Pu has a short half-life of 14.3 yr. To circumvent experimental difficulties, inelastic scattering of 53.96-MeV α particles on 242 Pu served as a surrogate for 241 Pu (n , f). The present text reports and discusses the average neutron multiplicity, in addition to the neutron multiplicity moments and distribution for equivalent neutron energies up to 20 MeV. Finally, the $\bar{ν}$ measured in this experiment agrees with previous measurements until 12 MeV, where discrepancies arise due to preequilibrium neutron emission.
Neutron multiplicity ,easurements With 3 He alternative: Straw neutron detectors
Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. In this study, a prototype neutron detector was built using 10 B as the converter in a special form factor called “straws” that would address the above problems by looking into the details of multiplicity distributions of neutrons originating from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3 He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10 B (in the form of enriched boron carbide: 10 B 4 C) for neutron detection instead of 3 He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect neutron multiplicity information from spontaneous fission sources using a single panel consisting of 60 straws equally distributed over three rows in high-density polyethylene moderator. In the following year, we developed the field-programmable gate array and associated DAQ software. Finally, this SDRD effort successfully produced a prototype NMC with ~33% detection efficiency compared to a commercial fission meter.
Empirical Bounding Analysis and User Recommendations for a Neutron Multiplicity Detector
Neutron multiplicity detectors are useful for a variety of applications including nuclear emergency response, nuclear nonproliferation, safeguards, and criticality safety. When measuring black-box problems (i.e., when the system being measured is completely unknown) with systems that have relatively low detection efficiency, expert analysis is frequently required to determine appropriate bounds for system parameters such as neutron multiplication and neutron leakage. This is because the detection efficiency can vary wildly, which also means that the resulting system parameters can have large variations. This work applies an empirical approach to provide bounds on system parameters (such as system multiplication, neutron leakage, and detector efficiency). The results of this bounding analysis are then used as inputs to provide recommendations to users regarding criticality safety. In addition to describing the method used, this work provides sample results from a measurement campaign performed at the National Criticality Experiments Research Center (NCERC).
239 Pu R -matrix Analysis and Neutron Multiplicities in the Neutron Energy Region up to a few keVs [Abstract]
The evaluation of 239 Pu neutron resonance parameters coupled to neutron multiplicities $\overline{v}_p$ is of particular importance to investigate the ($\mathcal{n, γf}$) reaction in which a $\mathcal{γ}$-ray emission occurs before the scission of the compound nuclear. This reaction has offered one explanation for the fluctuations in the measured values of $\overline{v}_p$ In this regard, the competition between ($\mathcal{n, γf}$) reaction and the direct fission process can be also included in the R matrix analysis of fission and capture measured data. The goal of this work is the coupled evaluation of the $\mathcal{n}$+ 239 Pu resonance parameters and related neutron multiplicities by ensuring the adoption of thermal neutron constants recently evaluated at the International Atomic Nuclear Energy as well as the recommended (thermal-neutron) induced prompt neutron fission spectrum (PFNS). Moreover, this new set of physical evaluated quantities should also guarantee the agreement for high-leakage solution benchmarks while keeping the good performance of large thermal solution assemblies.
Effects of Correlated and Uncorrelated Gamma Rays on Neutron Multiplicity Counting
Neutron multiplicity counting relies on time correlation between neutron events to assay the fissile mass, (α,n) to spontaneous fission neutron ratio, and neutron self-multiplication of samples. Gamma-ray sensitive neutron multiplicity counters may misidentify gamma rays as neutrons and therefore miscalculate sample characteristics. Time correlated and uncorrelated gamma-ray-like signals were added into gamma-ray free neutron multiplicity counter data to examine the effects of gamma ray signals being misidentified as neutron signals on assaying sample characteristics. Multiplicity counter measurements with and without gamma-ray-like signals were compared to determine the assay error associated with gamma-ray-like signals at various gamma-ray and neutron rates. Correlated and uncorrelated gamma-ray signals each produced consistent but different measurement errors. Correlated gamma-ray signals most strongly led to fissile mass overestimates, whereas uncorrelated gamma-ray signals most strongly lead to (α,n) neutron overestimates. Gamma-ray sensitive neutron multiplicity counters may be able to account for the effects of gamma-rays on measurements to mitigate measurement uncertainties.
Development of a lithium fluoride zinc sulfide based neutron multiplicity counter
Past 3He shortages led to investigations into replacement options for neutron detectors in systems that previously used 3He-based technologies. The goal of this research was to investigate the feasibility of a full-scale lithium fluoride with silver activated zinc sulfide (LiF/ZnS) based neutron multiplicity counter. The LiF/ZnS based neutron multiplicity counter (LiNMC) was developed based on an iterative process between modeling and experimental measurements. Each active region of the LiNMC contains five sheets of LiF/ZnS sandwiched between six sheets of wavelength shifting plastic to form neutron detection stacks. The wavelength shifted scintillation light was collected by photomultiplier tubes located on each end of the stacks. Twelve such detector stacks were placed around a sample chamber in a square arrangement with lithiated high density polyethylene blocks in the corners to reflect high energy neutrons and capture low energy neutrons. Preliminary calibration with a 252Cf neutron source showed that the LiNMC was able to achieve 36% neutron detection efficiency (ε) and an 11.7 μs neutron die-away time (τ) for a doubles Figure-of-merit (ε2/ τ) of 109. This is the highest doubles Figure-of-merit performance measured to-date for a 3He-free neutron multiplicity counter system. By the end of this project, the LiNMC’s basic components were integrated into a single laboratory scale system capable of proof-of-concept measurements.
Distinguishing Research Reactor Fuels Using Neutron Multiplicity - 25615
Neutron measurements are one of the reliable means of interrogation of fissile material. Neutron measurements are used for total counting (pure metal fissile samples) or counting coincidence/multiplicity (for impure fissile samples). Various flavors of neutron measurement are used routinely by the IAEA to determine the fissile mass of an unknown sample. The objective of this work is to design an experiment to distinguish the two different fuel types using neutron multiplicity method. The design of experiment is performed using Monte Carlo N- Particle (MCNP) transport code. General Electric (GE) designed 1-MWt pool-type research reactor at UMass Lowell (UMLRR) uses Materials Testing Reactor (MTR) plate-type fuel consisting of 19 full and 2 partial fuel assemblies, controlled by four boron control blades and one regulating control rod. Two different fuel types are available at the UMLRR facility. In 2008, UMass Lowell obtained slightly burnt fuel assemblies from the decommissioned WPI research reactor. The simulation results discussed in this paper show that within the limits of statistical error, the single and double moments for the WPI and UMLRR fuels can be measured. The two fuels have very similar composition and enrichments resulting in very similar neutron multiplicity moments. This implies that neutron multiplicity measurements alone would not be sufficient to distinguish between the two fuel types at low burnups. The change in the observed single-double ratio between each fuel type is less than 6 % which falls below the uncertainty in the efficiency of the JCC71 slab detectors. The neutron signature from low burnup and low enriched uranium fuel are not strong, however, these can be measured under low background and long measurement times. This would be an important consideration in designing the experiments and parallel gamma measurements will also be planned. (authors)
Boron coated straw-based neutron multiplicity counter for neutron interrogation of TRISO fueled pebbles
Pebble bed reactors (PBRs) can improve the safety and economics of the nuclear energy production. PBRs rely on TRIstructural-ISOtropic (TRISO) fuel pebbles for enhanced fission product retention. Accurate characterization of individual fuel pebbles would enable the validation of computational models, efficient use of TRISO fuel, and improve fuel accountability. Here, we have developed and tested a new neutron multiplicity counter (NMC) based on 192 boron coated straw (BCS) detectors optimized for 235 U assay in TRISO fuel. The new design yielded a singles and doubles neutron detection efficiency of 4.71% and 0.174%, respectively, and a die-away time of 16.7 μs. The NMC has a low intrinsic gamma-ray detection efficiency of 8.71 x 10 –8 at an exposure rate of 80.3 mR/h. In simulation, a high-efficiency version of the NMC encompassing 396 straws was able to estimate the 235 U in a pebble with a relative uncertainty and error both below 2% in 100 s.
Plutonium measurements with a fast-neutron multiplicity counter for nuclear safeguards applications
Measurements were performed at the Joint Research Centre in Ispra, Italy to field test a fast-neutron multiplicity counter developed at the University of Michigan. The measurements allowed the assessment of the system's photon discrimination abilities, efficiency when measuring neutron multiplicity, ability to characterize 240 Pu eff mass, and performance relative to a currently deployed neutron coincidence counter. We describe how this work is motivated by the need to replace and improve upon 3 He neutron detection systems for nuclear safeguards applications.
Neutron Multiplicity Analysis
Neutron multiplicity measurements are widely used for nondestructive assay (NDA) of special nuclear material (SNM). When combined with isotopic composition information, neutron multiplicity analysis can be used to estimate the spontaneous fission rate and leakage multiplication of SNM. When combined with isotopic information, the total mass of fissile material can also be determined. This presentation provides an overview of this technique.
Measurement and simulation of cosmic rays effects on neutron multiplicity counting
Explore the source record for details and available documents.
Neutron multiplicity monitor observations during 1965.
Cosmic ray secondary nucleon production of multiple neutrons observed and energy spectra measured, using multiplicity monitor
Identifying Nuclear Material via Prompt Photo-Neutron Multiplicity Measurements
Proof-of-principle measurements are reported demonstrating that multiplicity techniques can be used to identify prompt fission neutrons from photonuclear interrogation under circumstances where the fission neutrons may be accompanied by photodissociated neutrons of an identical energy spectrum, and where the emitted neutrons are naturally bunched in time by the pulsed nature of the interrogating photon beam. The technique shows promise as a method for the detection of highly enriched uranium (HEU) compared to techniques based on delayed neutrons because prompt neutrons are orders of magnitude more abundant, and compared to passive multiplicity techniques because actively induced fission rates are orders of magnitude higher than spontaneous fission rates in HEU. The technique also shows promise in that multiplicity signatures can be used to distinguish HEU from other fissionable material.
Towards a neutron multiplicity measurement with the Accelerator Neutrino Neutron Interaction Experiment
The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26 ton Gadolinium (Gd)-loaded water Cherenkov detector located on the Booster Neutrino Beam line at Fermilab. Its main goals are the measurement of the neutron multiplicity in neutrino-nucleus interactions as well as the cross-section of Charged Current Quasi-Elastic (CCQE) neutrino interactions on water. Besides the physics goals, the experiment also aims to be a testbed for new technologies such as Large Area Picosecond Photodetectors (LAPPDs) and Water-based Liquid Scintillators (WbLS). This thesis presents a preliminary measurement of the neutron multiplicity with {ANNIE}, using an analysis conducted on a fraction of the 2021 beam year. As preparatory measures, the efficiency of ANNIE's Front Muon Veto (FMV) was determined to be {$\bar{\varepsilon}_{\mathrm{FMV}} = (95.6 \pm 1.6)\%$} while the average efficiency for active scintillator paddles in the Muon Range Detector (MRD) was found to be {$\bar{\varepsilon}_ {\mathrm{MRD}} = (92.1 \pm 7.9)\%$}. Furthermore, the simulation framework used for ANNIE was validated and adapted to reproduce the experimental data by comparing the detector response for samples of Michel electrons, Americium Beryllium neutrons, and through-going muons. The analysis finds average neutron yields of {$\bar{n}_{\mathrm{data}} (\mathrm{beam}) = (0.272 \pm 0.010_{\mathrm{stat}})$} for an inclusive set of all identified muon neutrino candidates and {$\bar{n}_{\mathrm{data}} (\mathrm{beam,FV}) = (0.287 \pm 0.044_{\mathrm{stat}})$ for interactions which happened inside of the Fiducial Volume of ANNIE, which was optimized to increase the neutron detection acceptance. The presented neutron multiplicity values represent the number of detected neutrons after all event selection cuts and are not yet corrected for the neutron detection efficiency. An equivalent analysis on a simulated beam sample predicts neutron yields of $\bar{n}_{\mathrm{MC}}(\mathrm{beam}) = (0.515 \pm 0.0 07_{\mathrm{stat}})$ and $\bar{n}_{\mathrm{MC}}(\mathrm{beam,FV}) = (0.627 \pm 0.031_{\mathrm{stat}})$, indicating that the models tend to overpredict the number of neutrons produced in such interactions. Systematic errors have been briefly considered to contribute {$\sigma_{\mathrm{sys,FMV}} \sim 0.01\,$neutrons/$\nu$-interaction} due to the slight FMV inefficiency and {$\sigma_{\mathrm{sys,n}} \sim 0.05\,$neutrons/$\nu$-interaction} due to the neutron detection efficiency. Simulation studies further highlighted the importance of neutron detection in Diffuse Supernova Background (DSNB) searches. A combination of neutron tagging and Convolutional Neural Networks was found to reduce the most relevant Neutral Current Quasi-Elastic (NCQE) interaction background below the signal level, achieving a Signal-to-Background ratio of 4:1. In a further study, we investigated the positive impact of a deployment of a WbLS target on the energy reconstruction in ANNIE. WbLS provides a scintillation signal from hadronic recoils in addition to the charged lepton that can be included in neutrino energy reconstruction. It was found that a deployed WbLS volume in ANNIE improves the neutrino energy reconstruction from 14\% to 12\%, with the potential of going beyond this if more sophisticated reconstruction algorithms are developed in the future.
Deployable dead time corrections for neutron multiplicity measurements accounting for neutron correlations and multiple detector chains
Abstract Not Provided
NEUTRON MULTIPLICITY AND ACTIVE WELL NEUTRON COINCIDENCE VERIFICATION MEASUREMENTS PERFORMED FOR MARCH 2009 SEMI-ANNUAL DOE INVENTORY
The Analytical Development (AD) Section field nuclear measurement group performed six 'best available technique' verification measurements to satisfy a DOE requirement instituted for the March 2009 semi-annual inventory. The requirement of (1) yielded the need for SRNL Research Operations Department Material Control & Accountability (MC&A) group to measure the Pu content of five items and the highly enrich uranium (HEU) content of two. No 14Q-qualified measurement equipment was available to satisfy the requirement. The AD field nuclear group has routinely performed the required Confirmatory Measurements for the semi-annual inventories for fifteen years using sodium iodide and high purity germanium (HpGe) {gamma}-ray pulse height analysis nondestructive assay (NDA) instruments. With appropriate {gamma}-ray acquisition modeling, the HpGe spectrometers can be used to perform verification-type quantitative assay for Pu-isotopics and HEU content. The AD nuclear NDA group is widely experienced with this type of measurement and reports content for these species in requested process control, MC&A booking, and holdup measurements assays Site-wide. However none of the AD HpGe {gamma}-ray spectrometers have been 14Q-qualified, and the requirement of reference 1 specifically excluded a {gamma}-ray PHA measurement from those it would accept for the required verification measurements. The requirement of reference 1 was a new requirement for which the Savannah River National Laboratory (SRNL) Research Operations Department (ROD) MC&A group was unprepared. The criteria for exemption from verification were: (1) isotope content below 50 grams; (2) intrinsically tamper indicating or TID sealed items which contain a Category IV quantity of material; (3) assembled components; and (4) laboratory samples. Therefore all (SRNL) Material Balance Area (MBA) items with greater than 50 grams total Pu or greater than 50 grams HEU were subject to a verification measurement. The pass/fail criteria of reference 7 stated 'The facility will report measured values, book values, and statistical control limits for the selected items to DOE SR...', and 'The site/facility operator must develop, document, and maintain measurement methods for all nuclear material on inventory'. These new requirements exceeded SRNL's experience with prior semi-annual inventory expectations, but allowed the AD nuclear field measurement group to demonstrate its excellent adaptability and superior flexibility to respond to unpredicted expectations from the DOE customer. The requirements yielded five SRNL items subject to Pu verification and two SRNL items subject to HEU verification. These items are listed and described in Table 1.