Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron multiplicity counter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Performance Characterization of FB-Line Neutron Multiplicity Counter and Large Neutron Multiplicity Counter

Savanah River National Laboratory’s (SRNL) Nuclear Measurements group was tasked with characterizing the performance of two neutron multiplicity counters located at SRNL. Characterization measurements were made to determine the gate width, pre-delay, deadtime parameters, triples and doubles gate fractions, detector efficiency, and operating high voltage for the Large Neutron Multiplicity Counter (LNMC) and the FB Line Neutron Multiplicity Counter (FBLNMC). The parameters were determined, shown below, and were, as to be expected, slightly different than the previous calibrations, which were performed over 20 years ago. Several Pu samples were measured to validate the characterizations of the FBLNMC and LNMC. The measurements determined the sample Pu-240 mass within <2% deviation for the pure plutonium samples and ~8% for the mixed oxide sample. The pure Pu samples had significantly better accuracy compared with the impure mixed oxide sample due to the lack of induced fission or alpha,n neutrons from impurities. Overall, the characterization of the neutron multiplicity counters, and the determination of their operability has been completed successfully.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron coated straw-based neutron multiplicity counter for neutron interrogation of TRISO fueled pebbles

Pebble bed reactors (PBRs) can improve the safety and economics of the nuclear energy production. PBRs rely on TRIstructural-ISOtropic (TRISO) fuel pebbles for enhanced fission product retention. Accurate characterization of individual fuel pebbles would enable the validation of computational models, efficient use of TRISO fuel, and improve fuel accountability. Here, we have developed and tested a new neutron multiplicity counter (NMC) based on 192 boron coated straw (BCS) detectors optimized for 235 U assay in TRISO fuel. The new design yielded a singles and doubles neutron detection efficiency of 4.71% and 0.174%, respectively, and a die-away time of 16.7 μs. The NMC has a low intrinsic gamma-ray detection efficiency of 8.71 x 10 –8 at an exposure rate of 80.3 mR/h. In simulation, a high-efficiency version of the NMC encompassing 396 straws was able to estimate the 235 U in a pebble with a relative uncertainty and error both below 2% in 100 s.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MC-Lite: Development of a new lightweight multiplicity counter

This report details the development of a neutron multiplicity counter based on lithium doped plastic scintillators. This system has the capability to measure and discriminate fast neutrons, thermal neutrons, and gamma-rays allowing for multi-particle correlations in one device. The system was built and tested at Lawrence Livermore National Laboratory with Cf-252 in both bare configurations and surrounded by polyethylene and compared against the MC-15 multiplicity counter. Additionally, the detector was also placed outside of a subcritical assembly and demonstrated the ability to use correlated gamma-rays as a probe on the multiplication of the item.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Plutonium Mass Uncertainty Assessment Using a Cherenkov-Based Neutron Multiplicity Water Detector

We present a new analysis of the sensitivity of a water Cherenkov-based neutron multiplicity counter for nondestructive assay of trace quantities of 240 Pu. The multiplicity counter [water-based neutron detector (WaND)] contains 1.0 m 3 of water doped with 0.2% gadolinium in the form of a gadolinium salt (0.4% GdCl 3 ). It can be used for testing the presence of trace quantities of 240 Pu within a sample of unknown material by observing the correlated timing behavior of neutron capture candidates in the detector. The new analysis takes advantage of the fact that the detector is comprised almost entirely of a homogeneous medium, which permits the use of a simple model to reproduce the observed neutron capture timing behavior. Finally, the results of this analysis indicate that the detector has an absolute neutron detection efficiency of 23.4 ± 1.1% and is sensitive to a 240 Pu mass as small as 2.3 mg (at 1σ) after a 1-h data acquisition.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Special Nuclear Material Mass Estimates from Neutron Singles Count Rate [Poster]

The objective of this research was to create an algorithm to provide an estimate of special nuclear material (SNM) mass using only neutron count rate data from a Radioisotope Identification Device (RIID), rather than using time-correlated data from a neutron multiplicity counter. To meet this objective neutron count rate measurements of a 252 Cf source were taken at varying distances with an ORTEC Detective X, FLIR Identifinder 2, and an ORTEC RADEAGLET-R. An algorithm was created to estimate mass of SNM utilizing the singles rate equation and the measured absolute efficiency curves.

FLIR↗

Simulating gas-filled neutron detector responses with DRiFT

– Gas-filled neutron detectors have numerous applications across the nuclear engineering and nuclear physics fields. The ability to accurately model and simulate these detectors is important for those applications but is currently limited by the lack of readily-useable detector response software. Recently, the capabilities of DRiFT, a Detector Response Function Toolkit, were expanded to model gas-filled, He-3 and BF3, neutron detectors so that, combined with the radiation transport capabilities of the MCNP code, a high-fidelity treatment of gas-filled neutron detectors can be obtained. Further, this model has been validated by an experiment carried out with the Epithermal Neutron Multiplicity Counter and its capabilities have been demonstrated in two additional experiments. This work shows that utilizing DRiFT to post-process MCNP outputs produces more accurate results than using the MCNP code alone, reducing the difference between experimental and simulated results for measurements taken near the end of a He-3 tube, where the MCNP code struggles to model inactive regions of the detector, from a maximum of 35% with the MCNP code alone to 15% with the MCNP code plus DRiFT. DRiFT's diagnostic capabilities are also demonstrated with measurements for scenarios when pulse pileup or room return effects are significant and must be considered. Altogether, these measurements underpin the ability of DRiFT to accurately model and predict the behavior of gas-filled neutron detectors, making it a valuable tool for the design and testing of systems and experiments that utilize these detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Neutron Multiplicity Counting Experiments to Optimal Cross-Section Adjustments

This paper presents the first application of model calibration to neutron multiplicity counting (NMC) experiments for cross-section optimization that is informed by adjoint-based sensitivity analysis (SA) and first-order uncertainty quantification (UQ). We summarize previous work on SA applied to NMC and describe notable modifications and additions. We give the procedure for first-order UQ and Bayesian-inference-based parameter estimation (PE). We then discuss model calibration applied to NMC of a 4.5-kg sphere of weapons-grade, alpha-phase plutonium metal (the BeRP ball) with the nPod neutron multiplicity counter. For the BeRP ball in bare and polyethylene-reflected configurations, we discuss the sensitivity of the first- and second-moment detector responses (i.e., first and second moments of the NMC distribution, respectively) to the cross sections. We describe the sources of uncertainty in the measured and simulated responses. Specifically, uncertainty in the measured responses is due to both random and systematic sources. Uncertainty in the simulated responses is due to the cross-section covariances. We describe in detail the adjustment to the cross sections and cross-section covariances due to the optimization. Due to the contribution of systematic uncertainties to the measured response uncertainties, the adjustment to the cross sections is similar in trend but larger in magnitude compared to that recommended by previous work. We compare the measured responses to responses simulated with nominal and optimized cross sections, demonstrating that the best-estimate cross sections produce simulations of NMC experiments that are more accurate with reduced uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling and Simulation of MC-Small Design

In order to design a lightweight, highly portable neutron multiplicity counter for use in higher risk regions by mobile field teams, a redesign of the MC-15 is being performed, with the goal of producing a detector below 30 lbs for ease of transport. To achieve this, multiple MCNP® simulations were run, evaluating the number and positioning of the He-3 tubes in the detector as well as the amount of high-density polyethylene (HDPE) surrounding the tubes. Based on these simulations, the proposed redesign of the MC-15 (aka MC-Small) possesses 11 tubes and is 13 in wide, 3.21 in thick and 13 in tall. Including the changes to the positioning of the tubes and the removal of HDPE from less sensitive regions of the detectors (i.e. bases of tubes, back of detector), this resulted in an efficiency of 0.56% when measuring a bare Cf-252 source 19.69 in away, only 28% less efficient (relatively) than the MC-15 while weighing 18 lbs, 12 lbs less than the weight of the MC-15.

42 ENGINEERING↗

Evaluation of neutron dosimetry capabilities with the MC-15 portable multiplicity counter

This work proposes a preliminary neutron dose rate estimation method for a neutron multiplicity detector through measurement- and simulation-based analyses. Uncharacterized neutron-emitting sources may be encountered in situations such as nuclear emergency response, safeguards, and treaty verification. These circumstances may present irradiation risk to personnel conducting field assay, search, and characterization measurements. It is therefore of interest to provide a field neutron dosimetry capability with the existing neutron multiplicity counting (NMC) capabilities. To date, no commercially-available neutron detection systems are capable of both accurate NMC and real-time neutron dosimetry. This work will focus on estimating dose rate using input from a single fielded NMC called the MC-15. The energy-dependent neutron detection efficiency response of the MC-15 was quantified in monoenergetic neutron simulations and evaluated in response to two neutron-emitting sources and to a polyethylene-moderated source. The results were compared to existing neutron dosimeters and established the proof of concept for further investigation of the MC-15 for dose estimation. Measurement results were also replicated in simulations; additional simulations were then conducted to expand upon the limited empirical data. The initial empirical results provided a conversion factor appropriate for use when measuring 252 Cf neutrons that is independent of polyethylene shielding presence and thickness. The simulated data sets were then used to evaluate a fit equation allowing estimation of the neutron dose rate for less restricted geometric configurations and dependent only on the distance between the source and the detector. Additionally, the energy dependence of the efficiency response indicates that further empirical evaluations could provide energy-dependent conversion factors for broader neutron dosimetry capabilities with a wider range of neutron-emitting sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

233 U oxide Measurement Campaign Data: Passive and Active Neutron Multiplicity Measurements of Uranium Oxide Samples at Oak Ridge National Laboratory

During FY2023, three measurement campaigns were conducted at Oak Ridge National Laboratory. The goal was to quantify the neutron signatures of samples of uranium oxide containing uranium 233 and uranium-235. This report presents the neutron multiplicity data obtained using the large volume active well coincidence counter (LV-AWCC).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

252 Cf yield calibration method for nuclear material accountancy and safeguards practitioners

Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NCSP – AWE Collaboration [Slides]

Several points of collaboration between NCSP and AWE are noted, including the CIDAAS IS589 installation plan, CIDAAS testing, nuclear verification and detector physics, nuclear material control and nuclear security, and hands on criticality safety training.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterizing Shielded Special Nuclear Material by Neutron Capture Gamma-Ray Multiplicity Counting

We present a new neutron multiplicity counting analysis and measurement method for neutron-shielded fissile material using neutron-capture gamma rays. Neutrons absorbed in shielding produce characteristic gamma rays that preserve the otherwise lost neutron multiplicity signature. Neutron multiplicity counting provides estimates of fission parameters, such as neutron leakage multiplication, spontaneous fissioner (e.g. Pu-240) mass, and (α,n) ratio. Standard neutron multiplicity counting can incorporate the new neutron-capture gamma-ray multiplicity counting technique to characterize previously degenerate or intractable source configurations by maximizing the multiplicity signature. The new method decouples neutron source-detector interferences, such as reflection and thermalization time in the detector, that could improve measurements of the mean neutron lifetime. We also develop a detector prototype for the multiplicity counting of neutron-capture gamma rays and present detector design considerations, such as detection material and shielding, to optimize the detection of the 2.2 MeV hydrogen capture gamma ray. We simulate the prototype neutron- capture gamma-ray multiplicity counter against the BeRP ball in polyethylene shells to inform future measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Science & Technology Review: Awards for Livermore Innovation

At Lawrence Livermore National Laboratory, we focus on science and technology research to ensure our nation’s security. We also apply that expertise to solve other important national problems in energy, bioscience, and the environment. Science & Technology Review (S&TR) is published eight times a year to communicate, to a broad audience, the Laboratory’s scientific and technological accomplishments in fulfilling its primary missions. The publication’s goal is to help readers understand these accomplishments and appreciate their value to the individual citizen, the nation, and the world. In 2021, Lawrence Livermore technologies received three R&D 100 awards, which honor the year’s top 100 innovations from around the world. The feature article beginning on p. 4 describes the Laboratory’s winners: the Multiplicity Counter for Thermal and Fast Neutrons, Flux, and the Optical Transconductance Varistor. The 2021 awards raised the Laboratory’s total R&D 100 awards to 173 since 1978. The R&D 100 logo is reprinted in this issue with permission from R&D World magazine.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Verification of Special Nuclear Material (SNM) using Active Well Coincidence Counter (AWCC) and a High Purity Germanium (HPGe) Detector

SNM verification can be accomplished via two methods i.e. destructive analysis (DA) or nondestructive analysis (NDA). The DA modes are much more accurate compared to NDA modes; nevertheless, the sample's physical integrity is destroyed in the process. Techniques such as ICP-MS, ID-ICP-MS, TI-MS are few examples of DA, where a bulk material is ground and mixed with a solution (some form of acid) to acquire a homogenous sample. In contrast, NDA modes utilize signals emitted by the sample such as gamma, neutrons, light, or heat to analyze samples under investigation. HPGe detectors are some of the most frequently used gamma detectors to assay SNM. However, in a high activity scenario it provides a large uncertainty and sometimes becomes unfeasible to measure low energy gamma rays. Meanwhile, neutron detectors are not affected by the gamma background, therefore they can be used in addition to the gamma detectors to verify total fissile mass ({sup 235}U + {sup 239}Pu) of SNM. The AWCC is one of the thermal neutron NDA systems developed at the Los Alamos National Laboratory (LANL). It consists of 42 {sup 3}He detectors to measure gross neutrons (singles), coincidence neutrons (doubles), higher order multiplicity counting (triples, quadruples, etc.). It can effectively operate in both active and passive neutron interrogation modes. It can utilize AmLi, AmBe, or {sup 252}Cf active interrogation neutron sources. It is used to verify declared fissile mass ({sup 235}U or {sup 239}Pu) present in SNM. Objectives: Calibrate HPGe and AWCC for lightly irradiated (with enough {sup 137}Cs gamma background) ∼93% enriched HEU fuels; Verify fissile mass ({sup 235}U +{sup 239}Pu) content using AWCC and HPGe; Model and benchmark AWCC in MCNP6. Neutron coincidence and multiplicity counting: Two or more neutrons are coincident if they are detected by the system within the specified gate window; In AWCC: Gate window is 128 μsec; Induced fission in fissile material such as {sup 235}U and {sup 239}Pu - emission of time correlated neutrons - Singles, Doubles, Triples, or Quadruples; No induced fission in non-fissile materials- no correlated neutrons - only singles. SNM can be verified with high accuracy and precision using gamma and neutron NDA instruments such as HPGe and AWCC. Interaction with thermal neutrons. Non-fissile atoms - do not emit correlated neutrons. Fissile atoms - emit correlated neutrons during induced fission events. The time correlated neutrons can be detected by using coincidence or multiplicity counters such as AWCC. Likewise, {sup 235}U produces 186 keV gamma peak that can be measured by a HPGe gamma detector. Counts under 186 keV gamma peak provide information about {sup 235}U content. Combining AWCC and HPGe results can provide better understanding of special nuclear material under investigation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sensitivity of single and multiple cosmic ray neutrons to the surrounding medium in a lead-free monitor

In 1981-1985 the neutron component of cosmic rays was recorded, the effect of cosmic ray multiplication in lead being disregarded. The recording device consisted of neutron counters placed in a polyethylene retarder (polyethylene tubes with wall thickness of 2 cm). The device registered neutrons formed directly on the surface or not deep underground; the intensity of neutrons depended on the chemical composition of the substance. The neutron component was also measured in the Moscow Canal, Belomor-Baltic Canal, and in the Atlantic Ocean. The time variation of 5 minute data of the intensity obtained in the Belomor-Baltic Canal and in the Atlantic Ocean relative to the mean value in the open sea (in %) is presented.

Dorman, I. V.↗