Collision Tracking in OpenMC: Methods and Applications in Neutron Noise, Neutron Imaging, Time-of-Flight, and Multiplicity Counting

We present the development and application of a collision tracking feature within the OpenMC Monte Carlo particle transport code, designed for diverse applications such as neutron spectroscopy, scatter camera system, neutron noise, and multiplicity counting simulations. This feature enables the tracking of individual particle collisions, with potential applications in nuclear nonproliferation, reactor physics, and nuclear security. Additionally, the feature holds potential for the calibration of neutron detectors, specifically in converting light output into energy deposited within the detectors. The implementation consists of a set of filters—such as reaction type, energy, cell, and material—that constrain the set of collisions that are tracked, extensions to the Python API to enable simple input specification, and support for writing either OpenMC’s native HDF5-based format or the Monte Carlo particle list format. This feature was added to the official OpenMC release in version 0.15.3. In this work, the feature will be applied to showcase scenarios such as time-of-flight simulations, scatter-camera imaging for neutron source localization, neutron-noise analysis to extract integral kinetic parameters such as the prompt decay constant α, and multiplicity counting to estimate the mass of special nuclear materials. Ultimately, this feature aims to expand the application scope of open-source Monte Carlo particle transport codes such as OpenMC.

Monte Carlo code↗

Variance reduction techniques for Monte Carlo neutron noise simulations

The small fluctuations of the neutron flux caused by small perturbations of the macroscopic cross-sections take the name of neutron noise. Advanced Monte Carlo methods have been recently proposed in order to solve the neutron noise equations in the frequency domain, which allows establishing reference solutions to validate faster but approximate deterministic solvers. Due to the presence of particles carrying two statistical weights (for the real and imaginary components of the noise field), both of which may be positive or negative, Monte-Carlo simulations of neutron noise pose distinct challenges in terms of variance reduction. In this work we investigate two variance-reduction techniques, namely branchless collisions and weight cancellation, and probe their effectiveness for a benchmark con- figuration concerning the noise field induced by a pin with oscillating cross sections in a fuel assembly.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Estimating β eff from static, late-time Feynman neutron noise measurements

The effective delayed neutron fraction, β eff , is a kinematic parameter describing the contribution of delayed neutrons to the effective multiplication factor, $\kappa$ eff , and is of great interest to the nuclear criticality safety community and beyond. In fact, $\kappa$ eff presently must be inferred (as opposed to directly measured) since variables like β eff must be obtained from simulation, reference tables, or a dynamic or pulsed measurement where the assembly of fissile material is perturbed and not in steady state. Several recent works have proposed neutron noise techniques to estimate β eff from static measurements (such as benchmark experiments). This work experimentally investigates an approach based on looking at late-time (up to thousands of seconds) correlated neutrons in Feynman histograms. This work utilizes measurements of weapons grade plutonium and highly enriched uranium to construct late-time Feynman histograms and investigate a proposed methodology of estimating β eff from a fit of the distribution. Data is shown from both He-3 detectors and an organic scintillator array. This work is preliminary in nature, demonstrating some experimental feasibility and proposing improvements for future investigations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Frequency-domain vs time-domain SP{sub N} equations to simulate neutron noise

Inside the reactor core mechanical vibrations of fuel assemblies can produce high fluctuations around a steady-state configuration, known as neutron noise. This effect can cause the triggering of power reduction measures. Classically, diffusion theory has been used to simulate this behavior. However, this equation has some limitations if the materials of the reactor have strong variations. In this work, we use the diffusive time-dependent simplified spherical harmonics equations that improve the previous results without the necessity of using high computational requirements. In particular, two types of analyses with these equations (SP{sub 3}) are made: a frequency-domain and a time-domain. A numerical neutron noise benchmark tests the methodology and compare both formulations. First, numerical results show a good agreement between the amplitudes and phases of the SP3 equations computed with the frequency-domain and time-domain. Therefore, as the frequency-domain computation only requires to solve a linear system, it is a recommendable option for neutron noise computations. Second, one can conclude that for this type of nuclear systems, where the assemblies are not homogenized, the SP{sub 3} approximation results improve considerably the accuracy of the diffusion theory.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulations of neutron noise in the research reactor AKR-2: comparison between a discrete ordinates and a diffusion-based method

A diffusion-based and a discrete ordinates method are used to simulate a neutron noise experiment in the research reactor AKR-2 at the Technical University in Dresden, Germany. The AKR-2 reactor provides an interesting case for the comparison between the two methods because it is characterized by large heterogeneities and regions with low macroscopic neutron cross-sections. For the calculations, the same spatial discretization and the same set of two-energy macroscopic neutron cross-sections with isotropic scattering are used. Significant discrepancies between the diffusion-based and discrete ordinates methods are found in regions of the systems where the diffusion approximation is expected to be inaccurate in reproducing characteristics of the static neutron flux and neutron noise. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron Noise Analysis of the Neptunium Subcritical Observation (NESO) Experiment

The Neptunium Subcritical Observation (NeSO) experiment was a subcritical integral benchmark experiment. This experiment was designed in 2017-2018 and was performed at the National Criticality Experiments Research Center (NCERC) in 2019. Eight different subcritical configurations were measured with varying Nickel reflector thickness. For all configurations, a 3 He detection system was used to record neutron events. The focus of this work is to share neutron noise results of the measured data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Noise Analysis of the Neptunium Subcritical Observation (NESO) Experiment

The Neptunium Subcritical Observation (NeSO) experiment was a subcritical integral benchmark experiment. This experiment was designed in 2017-2018 and was performed at the National Criticality Experiments Research Center (NCERC) in 2019. Eight different subcritical configurations were measured with varying Nickel reflector thickness. For all configurations, a 3 He detection system was used to record neutron events. The focus of this work is to share neutron noise results of the measured data.

3-Helium↗

High Multiplication Neutron Noise Measurements Using the 7uPCX Assembly

The Seven Percent Critical Experiment, or 7uPCX, is a system that mimics the physics of light water nuclear reactor systems by using uranium dioxide fuel pins at an enrichment of approximately 7%. 7uPCX is often used for benchmarking and nuclear data purposes. As part of a collaboration between Lawrence Livermore National Laboratory, Los Alamos National Laboratory, Sandia National Laboratories, and the Institut de Radioprotection et de Sûreté Nucléaire, measurements were performed in support of a high-multiplication, subcritical benchmark candidate for a thermal system. The measurements were completed by making subcritical configurations using the fuel loading pattern of a well-documented configuration of the Seven Percent Critical Experiment at Sandia National Laboratories, which exists as a benchmark in the International Criticality Safety Benchmark Evaluation Project handbook. These measurements, which aimed to capture multiplications ranging from approximately 10 to 1,000, also serve as an intercomparison between both the fielded detector systems and analysis methodologies with the goal of better characterizing the detectors and their ability to capture the state of the criticality these types of systems. Los Alamos National Laboratory’s measurements for this collaboration were made with five linked helium-3 based neutron multiplicity detectors placed on the periphery of the reactor tank beyond the infinite reflector thickness of water, and four organic scintillators placed in dry-wells in-reactor near the edge of the upper fuel grid plate. This work captures the Los Alamos National Laboratory measurements, the Rossi-α and Feynman-Y results, provides an intercomparison between the results of the 3 He neutron detectors and the organic scintillators, compares to simulation where possible, and expands on future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Real-Time Neutron Noise Analysis System for Fuel Debris Removal at Fukushima Daiichi

The decommissioning of Units 1, 2, and 3 at Fukushima Daiichi presents unique challenges, particularly in mitigating the risk of re-criticality during fuel debris removal. Disturbing previously stable debris configurations has the potential to cause changes in the multiplication of the system, necessitating real-time monitoring to ensure operational safety. Current neutron detection systems, primarily passive, are not optimized for continuous real-time analysis and are limited in their ability to detect rapid changes in system reactivity.

Neutron Detection Systems↗

Gamma Neutron Correlated Noise of the EUCLID Critical Experiment

In this work, we present results from gamma noise measurements of a fast plutonium critical system for the first time. These results are compared to the more traditional method of neutron noise. Additionally, we investigate cross correlations of neutron and gamma signals and discuss the advantages of doing so.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparison of Measured and Simulated Neutron Counting with 3He Detectors and the Subcritical Water-Moderated UO2 7uPCX Assembly

An experiment designed to compare neutron noise analysis techniques on subcritical assemblies using differing neutron detector designs was developed as a collaborative effort between the Institut de radioprotection et de surete nucleaire (IRSN), Los Alamos (LANL), Lawrence Livermore (LLNL), and Sandia National Laboratories. This experiment has the final goal of characterizing neutron noise analysis accuracy in determining multiplication in light water systems for various neutron detection systems. This experiment utilized the Seven Percent Critical Experiment (7uPCX) facility at Sandia National Laboratories. The 7uPCX is an assembly designed to investigate light water systems with fuel enrichment above 5% and is able to use square or hex grid plates with varying pitches.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of the MUSIC 3 He Multiplicity Data

A measurement campaign called the Measurement of Uranium Subcritical and Critical (MUSiC) was performed on a range of configurations of highly-enriched uranium (HEU) from December 2020 through April of 2021. While part of the focus was to measure reactor kinetics parameters on delayed supercritical systems, an additional focus was performing neutron noise measurements on subcritical configurations from deeply subcritical to nearly delayed critical. Multiple detector systems were used to perform these measurements, such as a 3 He multiplicity detector called the Neutron Multiplicity Array Detector (NoMAD) and a liquid scintillator system called the Rossi-α Measurement Rapid Organic Discriminating Detector (RAM-RODD). Also included were a scintillator system from the University of Michigan and a set of small 3He tubes that have previously been used to measure Rossi-α values on near-critical systems. The focus of this paper will be a comparison of prospective analysis methods for the NoMAD measurements. Previous subcritical measurements at the National Criticality Experiments Research Center (NCERC) submitted to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) used the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. This relies on the time correlations of neutron detections to infer the spontaneous fission rate and neutron multiplication of a system through binning the time tagged detections and analyzing resulting histograms of the numbers of counts. However, there are other neutron noise methods that rely on similar processes, such as the Hansen-Dowdy formalism which uses a slightly different methodology to extract multiplication from the neutron multiplicity counting moments. Comparisons can be made between these experimental results and those obtained through simulations to validate or identify deficiencies in analysis, detection methods, or the underlying nuclear data. Different time gating strategies and their effects on count rate uncertainties are also investigated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗