Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron scintillator screen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Boron-Based Neutron Scintillator Screens for Neutron Imaging

In digital neutron imaging, the neutron scintillator screen is a limiting factor of spatial resolution and neutron capture efficiency and must be improved to enhance the capabilities of digital neutron imaging systems. Commonly used neutron scintillators are based on 6 LiF and gadolinium oxysulfide neutron converters. This work explores boron-based neutron scintillators because 10 B has a neutron absorption cross-section four times greater than 6Li, less energetic daughter products than Gd and 6 Li, and lower γ-ray sensitivity than Gd. These factors all suggest that, although borated neutron scintillators may not produce as much light as 6 Li-based screens, they may offer improved neutron statistics and spatial resolution. This work conducts a parametric study to determine the effects of various boron neutron converters, scintillator and converter particle sizes, converter-to-scintillator mix ratio, substrate materials, and sensor construction on image quality. The best performing boron-based scintillator screens demonstrated an improvement in neutron detection efficiency when compared with a common 6 LiF/ZnS scintillator, with a 125% increase in thermal neutron detection efficiency and 67% increase in epithermal neutron detection efficiency. The spatial resolution of high-resolution borated scintillators was measured, and the neutron tomography of a test object was successfully performed using some of the boron-based screens that exhibited the highest spatial resolution. For some applications, boron-based scintillators can be utilized to increase the performance of a digital neutron imaging system by reducing acquisition times and improving neutron statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light output and neutron detection efficiency of boron-based neutron scintillator screens for neutron imaging

Recent research has explored the development of boron-based neutron scintillator screens, which potentially offer improved spatial resolution and neutron capture efficiency compared to traditional lithium-based screens. This work builds upon previous efforts to improve boron-based neutron scintillators by assessing a newer generation of boron-based scintillator screens fabricated using different compositions and fabrication approaches compared to previous generations of screens. Some of the test screens exhibit higher light output than previous efforts and higher neutron capture efficiency than lithium-based screens. This paper describes the current state of screen development, measurement results for the most recent generation of screens, and future activities.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Boron-Based Neutron Scintillator Screen Characterization with X-Rays and Neutrons

Recent work on boron-based neutron scintillator screens suggests these screens can offer superior performance when compared to commonly used screens. Borated neutron scintillator screens perform well in terms of light output (5-6 times greater than a standard Gadox screen) and detection effi-ciency (larger than standard LiF+ZnS screens). However, previously manu-factured boron-based screens have exhibited non-uniform surface coating and a poor mixture between phosphor and converter particles. The objective of this work was to evaluate newly fabricated scintillator screens to deter-mine if enhanced fabrication methods produced a more homogeneous distribution between neutron converter and scintillation phosphor particles. Uniformity of scintillator material deposition was also inspected. This new iteration of screens appeared more uniform than previous generations with the new coating method improving surface chemistry and scintillator material homogeneity. Additionally, a new methodology for screen characterization, involving the correlation of a neutron image taken with a borated scintillator screen to X-ray computed tomography of that same screen, was demonstrated to elucidate a relationship between scintillator screen thickness and relative light output of the screen under neutron exposure. This method suggested that the ideal thickness of scintillator material was ~150 µm to maximize light output of the screen.

36 - MATERIALS SCIENCE↗

Fast Neutron Scintillator Screens for Neutron Imaging Using a Layered Polymer-Phosphor Architecture

Fast neutrons enable a nondestructive examination of dense, large, and highly attenuating samples due to their lower interaction probability compared to thermal neutrons. However, this also creates a challenge in fast neutron imaging, as the thicker sensors necessary to detect fast neutrons degrade an image’s spatial resolution due to scattering within the sensor and the indeterminate depth of interaction in the sensor. This work explores the advantages of a fast neutron imaging screen with a layered polymer-phosphor screen approach as opposed to a mixed polymer-phosphor screen typically used in fast neutron imaging. Proton recoil is the primary conversion mechanism for fast neutron imaging. Simulations showed that the recoil proton range of typical fast neutrons is approximately 200 µm, however, tests at Idaho National Laboratory revealed that the light output of these screens increased at much greater polymer thicknesses. The NECTAR fast neutron beamline at FRM II was used to test the imaging performance of layered fast neutron imaging screens. Distinguishing between the fast-neutron and γ-ray signals is a major challenge in fast neutron imaging because all fast neutron sources also produce γ-rays. A relative comparison between a control plate and the fast neutron screen was made to distinguish between a γ-ray and fast neutron signals. MCNP modeling quantified the γ-ray and fast neutron contributions to the images measured at NECTAR, which were approximately a 75% γ-ray image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring Thickness-Dependent Relative Light Yield and Detection Efficiency of Scintillator Screens

Digital camera-based neutron imaging systems consisting of a neutron scintillator screen optically coupled to a digital camera are the most common digital neutron imaging system used in the neutron imaging community and are available at any state-of-the-art imaging facility world-wide. Neutron scintillator screens are the integral component of these imaging system that directly interacts with the neutron beam and dictates the neutron capture efficiency and image quality limitations of the imaging system. This work describes a novel approach for testing neutron scintillators that provides a simple and efficient way to measure relative light yield and detection efficiency over a range of scintillator thicknesses using a single scintillator screen and only a few radiographs. Additionally, two methods for correlating the screen thickness to the measured data were implemented and compared. An example 6LiF:ZnS scintillator screen with nominal thicknesses ranging from 0–300 μm was used to demonstrate this approach. The multi-thickness screen and image and data processing methods are not exclusive to neutron scintillator screens but could be applied to X-ray imaging as well. This approach has the potential to benefit the entire radiographic imaging community by offering an efficient path forward for manufacturers to develop higher-performance scintillators and for imaging facilities and service providers to determine the optimal screen parameters for their particular beam and imaging system.

42 ENGINEERING↗

Gamma Discriminating Scintillation Screens for Digital Transfer Method Neutron Imaging

A collaborative project between Idaho National Laboratory (INL) and Paul-Scherrer Institute (PSI) is investigating a new type of scintillation screen that uses ZnS scintillator material with a dysprosium neutron converter instead of traditional prompt converters such as 6Li. Such a screen exposed to a neutron beam creates a latent image by neutron activation of the dysprosium in the scintillator screen. The activated screen is transported into a camera box allowing the camera to read a digital image from the photons emitted by the activated scintillation screen. Such an imaging system combines modern camera-based system architecture with the approach of traditional indirect transfer method radiography. The results show for the first time that the combination of dysprosium with a scintillation material like ZnS can produce light which is measurable under common camera-based detection conditions and that neutron radiographic images of reasonable quality can be produced. The resolution was poorer than expected at ~ 300 µm, but is on the order of the desired resolution of 100 µm. Potential improvements and additional converter materials may be investigated in the future that could increase the light output and improve spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of borated scintillator screens for high-resolution neutron imaging

The most commonly used screens for neutron imaging consist of 6 LiF + ZnS. This type of screen yields the highest light output per detected neutron. For high resolution, gadolinium oxysulfide (GOS, Gadox) screens are employed, which have a much higher detection efficiency, but a light output so much lower than LiF + ZnS that measurements are often limited by photon statistics. Historically, screens using boron as a neutron-sensitive material have not been very successful. However, a new preparation method was introduced recently that produces light output higher than Gadox with detection efficiency greater than LiF + ZnS. Measurements of these new borated screens were performed at the NeXT facility at ILL, Grenoble, in comparison to a high resolution Gadox screen.

10B↗

LumaCam: a novel class of position-sensitive event mode particle detectors using scintillator screens

A new type of position-sensitive detectors is gaining attention in the neutron community. They are scintillator based detectors that detect the scintillation light on an individual photon basis via an image intensifier and a fast image sensor. Their readout operates in event mode i.e. it produces information about individual neutron interactions, reconstructed from the sensor data, thus enabling to achieve superior spatial and temporal resolutions compared to regular detectors. Although the development of current detectors is focused on neutrons, the concept is also applicable to the detection of other particles such as high-energy photons. This document provides a description on how these detectors are built, how they operate, and what their characteristics are. An example of a detector implementation based on a Timepix3 chip is described to illustrate the detector concept. This includes a detailed description of the algorithm that reconstructs the neutron interactions from the sensor data, one of the core components that sets it apart from established scintillator-based imaging detectors. Energy-resolved epithermal neutron radiography was performed at the ISIS EMMA beamline with this detector, illustrating some of the fundamental differences in the data that can be produced with the new type of detector compared to more established types of scintillator based neutron detectors. The term LumaCam is proposed to refer to this new class of position-sensitive event-mode detectors.

47 OTHER INSTRUMENTATION↗

Novel Nuclear Reactions Observed in Bremsstrahlung-Irradiated Deuterated Metals

d-D nuclear fusion events were observed in an electronscreened, deuterated metal lattice by reacting cold deuterons with hot deuterons (d*) produced by elastically scattered neutrons originating from bremsstrahlung photodissociation (where “d” and “D” denote 2H). Exposure of deuterated materials (ErD3 and TiD2) to photon energies in the range of 2.5 to 2.9 MeV resulted in photodissociation neutrons that were below 400 keV and also the 2.45-MeV neutrons, consistent with 2H(d, n)3He fusion. Additionally, neutron energies of approximately 4 and 5 MeV for TiD2 and ErD3 were measured, consistent with either boosted neutrons from kinetically heated deuterons or Oppenheimer-Phillips stripping reactions in the highly screened environment. Neutron spectroscopy was conducted using calibrated lead shielded liquid (EJ-309) and plastic (stilbene) scintillator detectors. The data support the theoretical analysis in a companion paper, predicting fusion reactions and subsequent reactions in the highly screened environment.

Bruce M Steinetz↗

Synergistic effects of Al, Ga, and In doping on ZnO nanorod arrays grown via citrate-assisted hydrothermal technique for highly efficient and fast scintillator screens

To be used as efficient alpha particle scintillator in the fields of nuclear security, nuclear nonproliferation and high-energy physics, scintillator screens must have high light output and fast decay properties. While there has been a great deal of progress in scintillation efficiency, achieving fast decay time properties are still a challenge. In this work, the near band edge (NBE) UV luminescence and alpha particle induced scintillation properties of vertically aligned densely packed ZnO nanorods (NRs) doped with Al, Ga, and In have been thoroughly investigated. The high crystalline hexagonal wurtzite structure with a strong orientation through the c -axis plane (002) and aspect ratios in the range 13–22 have been observed for all ZnO NRs. Electron paramagnetic resonance (EPR) analysis exhibited paramagnetic signals at g ≈ 1.96 for all ZnO NRs. A cost effective green hydrothermal synthesis technique was employed to grow well-aligned NRs. Using citrate as an additive acting as a strong reducing agent in the solution during the crystal growth, defects on the surface are significantly suppressed, thereby enhancing the NBE UV emission. Significantly higher NBE UV emission was observed from the top surface of ZnO NRs in cathodoluminescence (CL) microscopy. Results show that citrate assisted donor doping of ZnO NRs not only reduces the defect emission and NBE self-absorption, but also induces fast decay time (~ 600–700 ps), which makes ZnO NRs a good candidate for fast alpha particle scintillator screens used in associated particle imaging for time and direction tagging of individual neutrons generated in D–T and D–D neutron generators.

36 MATERIALS SCIENCE↗

Energy-resolved fast-neutron radiography using an event-mode neutron imaging detector

Energy-resolved fast-neutron radiography is a powerful non-destructive technique that can be used to remotely measure the quantity and distribution of elements and isotopes in a sample. This is done by comparing the energy-dependent neutron transmission of a sample with the known cross-sections of individual isotopes. The reconstruction of the composition is possible due to the unique features (e.g. resonances) in the cross-sections of individual isotopes. At short-pulsed (≲ 1 ns) neutron sources, such information is accessible via time-of-flight neutron imaging in principle, but requires a detector with nanosecond temporal resolution. Conventional neutron detectors can meet this requirement only by heavily compromising spatial resolution or efficiency. Here, we present a unique approach on fast neutron resonance radiography using a scintillator-based event-mode imaging detector at a short-pulsed neutron source, including first results on spatially mapped resonance profiles using MeV neutrons. The event mode approach applied in the presented detector allows recording of individual neutron interactions with nanosecond precision in time and sub-mm resolution in space. As a result, the entire available neutron energy spectrum can be measured for each pulse. At the same time, the use of a thick scintillator screen and lenses to focus the produced light results in a highly flexible field of view and a high interaction probability in the sensitive volume of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flash Neutron Imaging [Poster]

The NNSS has extensive historical experience with high-fidelity flash neutron imaging which may be applicable to the needs of NA-22. In recent neutron imaging tests, a dense plasma focus (DPF) discharges a capacitor bank across a hydrogen-filled diode to create a flash of fusion neutrons emitted from a point, which can be used for active interrogation. Object inspection may include both radiography transmission imaging as well as emission imaging of the subject via an aperture. A scintillator screen (coupled to a low-Z converter when necessary) converts deposited energy to visible light, which is relayed through optics to an ultra-sensitive visible imager contained in a light-tight box. Flash photon imaging, utilizing bremsstrahlung emission instead of fusion neutrons, is also available and is more mature.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

System Response Characterization for a d–t Neutron Radiography System

We report the system response of a pixelated associated particle imaging (API) neutron radiography system. The detector readout currently consists of a 2x2 array of organic glass scintillator detectors, each with an 8x8 array of optically isolated pixels that match the size and pitch of the ARRAYJ-60035-64P-PCB Silicon Photomultiplier (SiPM) array from SensL/onsemi with 6x6 mm 2 SiPMs. The alpha screen of the API deuterium-tritium neutron generator is read out with the S13361-3050AE-08 from Hamamatsu, which is an 8x8 array of 3x3 mm 2 SiPMs. Data from the 320 channel system is acquired with the TOFPET2-based readout system. We present the predicted imaging capability of an eventual 5x5 detector array, the waveform-based energy and pulse shape characterization of the individual detectors, and the timing and energy response from the TOFPET2 system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗