Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutrons, SNS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analysis of the time-of-flight neutron scattering cross-section data for light water measured at the SEQUOIA spectrometer, Spallation Neutron Source (SNS)

Thermal neutron scattering cross-section data for light water available in the major nuclear data libraries observes significant differences especially at reactor operating temperatures. During the past few years there has been a renewed interest in reviewing the existing thermal scattering models and generating more accurate and reliable thermal scattering cross sections using existing experimental data and in some cases based on Molecular Dynamics (MD) simulations. There is a need for performing new time-of-flight experiments at high temperatures and pressures, to have a better understanding of the physics involved in the scattering process that could help improve the existing TSL data.Lack of experimental thermal scattering data for light water at high temperatures led to a new measurement campaign within the INSIDER project at the Institut de radioprotection et de sûreté nucléaire (IRSN). Double differential scattering cross section for light water have been measured at the SEQUOIA spectrometer based at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory, United States. Several measurements have been carried out at different temperatures and pressures corresponding to liquid light water. Measurements at five different incident neutron energies Ei (8, 60, 160, 280 and 800 meV) have been carried out to help exploring different regions of the frequency spectrum. This paper presents the analysis of the dynamic structure factor and the derived frequency spectrum of light water. The analysis of the experimental data would provide one with better confidence, the behavior of thermal scattering cross sections for light water at high temperatures, knowledge of which is very important for the design of novel reactors as well as existing pressurized water reactors.

Jaiswal, V↗

Monitoring the SNS basement neutron background with the MARS detector

Here, we present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. Furthermore, these data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be 1.20 ± 0.56 neutrons/m 2 /MWh for neutron energies above ~3.5 MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

H - Ion Source RF Plasma Testing with 13 MHz and 27 MHz at the Spallation Neutron Source (SNS)

The baseline RF-driven H⁻ ion source configuration at the Spallation Neutron Source (SNS) facility uses a continuous wave (CW) 600 W 13 MHz RF system to ignite and maintain a low-density plasma inside the ion source vacuum chamber. After the continuous low-density 13 MHz plasma has been established, a pulsed (typical 1 ms pulse width and 60 Hz pulse repetition rate) 80 kW 2 MHz RF system is used to increase the plasma density to produce the pulsed H⁻ ion beam. Incremental upgrades and improvements to the SNS ion source systems have resulted in the ability to reliably operate an H⁻ ion source for SNS neutron production run cycles that can last up to four months. Conditions inside the SNS H⁻ ion source evolve throughout a four-month run cycle due to changes in impurity levels, sputtering, and erosion. As the internal ion source conditions change during the run cycle, there can also be changes in plasma stability and the 13 MHz RF power level required to ignite the plasma. This paper presents the preliminary results of testing performed on the SNS Ion Source Test Stand (ISTS) system where we looked at plasma ignition and plasma stability using 27 MHz RF in place of the baseline 13 MHz RF system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution neutron time-of-flight measurements for light water at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory

Series of light water inelastic neutron scattering experiments have been made at the Oak Ridge National Laboratory (ORNL), Spallation Neutron Source (SNS) covering temperatures ranging from 295 K to 600 K and pressures of 1 bar and 150 bar. The temperatures and pressures ranges correspond to that of pressurized light water reactors. The inelastic scattering measurements will help the development of light water thermal scattering kernels, also known as S (α,β) thermal scattering law (TSL), in a consistent fashion given the amount and the quality of the measured data. Light water thermal scattering evaluations available in existing nuclear data libraries have certain limitations and pitfalls. This paper introduces the state of the art of the light water thermal scattering cross-section data not only for room temperature but as well as for reactor operating temperatures, i.e. 550 - 600 K. During the past few years there has been a renewed interest in re-investigating the existing TSL models and utilize the recent experimental data or perform molecular dynamics simulations. It should be pointed out that no single TSL evaluation is based entirely on experimental data and one has to rely on TSL models or a combination of both. New TOF measurement of light water at the SNS, with a detailed description of the experimental setup, measurement conditions, and the associated foreseen results is presented in this paper. The analysis of the experimental data would help in validating the existing approach based on old experimental data or based on molecular dynamic simulations using classical water models, knowledge of which is very important to generate TSL libraries at reactor operating conditions.

Leal, Luiz C.↗

Neck Rupture and Scission Neutrons in Nuclear Fission

Just before a nucleus undergoes fission, a neck is formed between the emerging fission fragments. It is widely accepted that this neck undergoes a rather violent rupture, despite the absence of unambiguous experimental evidence. The main difficulty in addressing the neck rupture and saddle-to-scission stages of fission is that both are highly nonequilibrium processes. Here, we present the first fully microscopic characterization of the scission mechanism, along with the spectrum and the spatial distribution of scission neutrons (SNs), and some upper limit estimates for the emission of charged particles. The spectrum of SNs has a distinct angular distribution, with neutrons emitted in roughly equal numbers in the equatorial plane and along the fission axis. They carry an average energy around 3±0.5 MeV for the fission of 236 U, 240 Pu, and 252 Cf, and a maximum of 16–18 MeV. We estimate a conservative lower bound of 9%–14% of the total emitted neutrons are produced at scission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The development of a 6 Li-based pixelated neutron detector for neutron reflectometry at the Spallation Neutron Source

We present a high-rate 6 Li-based pixelated neutron detector developed for neutron reflectometry instruments at the Spallation Neutron Source (SNS). The neutron detector has a pixelated design: each 6 Li scintillator element has its own photosensor and independent channel readout. This paper focuses on the general overview of the detector design and construction, the characterization of the pixelated detector, and the results of the first neutron reflectivity experiments conducted using the pixelated neutron detector at the SNS Liquid Reflectometer (BL-4B). The pixelated neutron detector demonstrated a global time-average count rate of ≥ 1.8 x 10 6 cps, at least 3 orders of magnitude higher than that of the existing neutron detector ( 3 He-based Multi-Wire Proportional Counter), and a local instantaneous count rate of ≥ 1.73 x 10 6 cps / cm 2 . The maximum counting rate of the detector has not yet been determined as the detector is capable of handling the maximum flux available at the beamline. Furthermore, the outcome of the neutron reflectivity experiments showed that the pixelated neutron detector is a promising candidate for next-generation neutron reflectometry instruments at the SNS.

6Li, silicon photomultiplier↗

Evolution of the high-power spallation neutron mercury target at the SNS

The Spallation Neutron Source (SNS) began operation in 2006 and first operated at its full 1.4 MW power in 2013. Targets, which receive the pulsed proton beam, were a limiting factor for reliable full power operation for several years. Reaching reliable target operation at 1.4 MW required not only changes to the target design but also support and coordination across the entire SNS enterprise. The history and some key lessons learned are presented.

Winder, Drew E↗

Comparison of the Neutronic Performance of IRP-1 and IRP-2 at SNS

The Spallation Neutron Source (SNS) operated from start-up, in May 2006, through December, 2017 before replacing the Inner Reflector Plug (IRP). This component is the most costly and time-consuming “regular maintenance” replacement foreseen in the operation of the First Target Station (FTS). The IRP includes beryllium reflector blocks, steel and aluminum support structures, aluminum moderator vessels (which in turn include gadolinium and cadmium neutron poisons) and water coolant systems. The lifetime of this multi-million dollar component is driven by poison and decoupler burnup in moderator vessels. The moderators include these neutron poisons to best match neutron beam performance with scattering instrument needs. The burnup that comes with use changes the performance of the moderators until they no longer server their intended purpose. The reasonable desire to maximize the IRP lifetime means that the moderator performance at the Beginning Of Life (BOL) is significantly “over poisoned” and different from the performance at moderator End Of Life (EOL). Upon installation of the second IRP article, IRP-2, the SNS Neutronics team characterized the performance of the neutron beamlines in order to assess the differences between them, primarily by comparing the EOL performance of IRP-1 to the BOL performance of IRP-2. While IRP-2 was largely similar to IRP-1 in its conceptual design, there were some differences in the specific design of IRP-2 to support enhanced manufacturability, and the change from IPR-1 to IRP-2 coincided with the replacement of the light water in the IRP cooling loop with heavy water, as had been intended in the SNS design but not implemented during construction because of heavy water availability.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A scalable transformer model for real-time decision making in neutron scattering experiments

The U.S. Department of Energy's (DOE's) neutron research facilities at Oak Ridge National Laboratory (ORNL), including the High Flux Isotope Reactor (HFIR) and the Spallation Neutron Source (SNS), are a state-of-the-art neutron scattering facility that allows researchers to study the structure and dynamics of materials at the atomic scale. At the SNS, neutrons are measured using the time-of-flight (TOF) technique as they move through a neutron beamline to interact with a sample. Large volumes of neutron scattering data are collected and recorded in neutron event mode. Optimal productivity of the TOF instrument is limited due to the lack of real-time data analysis tools. The large amount of data generated by the experiments can be challenging to process and analyze in real time, particularly for experiments that require rapid feedback and adjustment of experimental parameters. The regular computer/workstation cannot keep up with the experiment speed to provide real-time feedback to adjust experimental parameters, so connecting the supercomputers available to the neutron facility is necessary to achieve real-time data analysis and experiment steering. To address this challenge, we exploit the Frontier supercomputer at Oak Ridge Leadership Computing Facility (OLCF) to train a scalable temporal fusion transformer model for real-time decision making of TOF neutron scattering experimentation. Here, in this paper, we present the results using Frontier to provide the processing power needed to rapidly process and analyze large volumes of single-crystal diffraction data collected at TOPAZ, a neutron time-of-flight Laue single-crystal diffractometer at the SNS.

97 MATHEMATICS AND COMPUTING↗

Magnetic Designs of New First Target Beamline Magnets for the ORNL SNS Upgrade

The Spallation Neutron Source (SNS) at ORNL currently is being upgraded from 1.0 GeV to 1.3 GeV. Several water-cooled magnets should be upgraded to transport 30% of higher beam energy. New chicane, injection/extraction septum, and Lambertson magnets were designed. Designing the magnets was a challenging task because the new magnets required good combined integrated field quality and needed to occupy the old magnets space but with about 20% greater integrated magnetic field. Additional strong requirements applied to the magnets fringe field do not disturb the circulating beam. The special field profiles had to be provided in foil areas between magnets. The analysis described here was based on OPERA3D simulations. A special technique was used for analyzing the integrated field harmonics. Initially, the particle track was simulated, and integrated field components were calculated along this track for the reference radius, which were used for the harmonics analysis. In addition, 3D field maps were provided for beam optics simulations. The final beamline analysis confirmed good beam transmission and low losses.

3d field maps↗

Overview on Shielding Analyses for the VENUS Instrument at SNS

VENUS, a world‐class versatile neutron imaging instrument, is under construction and is expected to be completed and ready to start commissioning in 2023. The range of cold to epithermal neutrons at SNS will give users of VENUS access to novel imaging methods, as well as to significantly improved existing methods. The instrument is being built on beam line 10 at Spallation Neutron Source (SNS) First Target Station (FTS) facing a decoupled poisoned hydrogen moderator. Instrument design, which includes optics, Front-End components and instrument enclosure components and shape started over 10 years ago and during this time had significant changes. All changes were supported by neutronics analyses to provide adequate shielding for both Front-End and instrument enclosure.Final optics design will provide the field of view (FOV) at the detector position (where the image is formed) to be as high as 0.20 by 0.20 m. Both the beam, which contains a large fraction of high-energy neutrons, and the desire for a large footprint on the detector are challenges for shielding design and budget, because the driving cost for the instrument is the beam line and enclosure shielding. For cost reason VENUS baseline design is optimized with respect to both the instrument cave footprint and its wall thickness, and Front-End shielding is tailored along the beam. Analyses are performed with the Monte Carlo particle transport code MCNPX version 2.7.0 to make choices on materials, thicknesses and configurations of the shielding. Numerous calculations are performed to meet space and coast constrain and to satisfy instrument physics needs and to comply with radiation protection requirements.

Gallmeier, Franz X.↗

Neutron Positioning and Geometric Distortion Correction on the SNS SiPM Anger Camera

Neutron Anger cameras are scintillator-based thermal neutron detectors that utilize pixelated photosensors to read out visible light signals and position neutrons accurately They are versatile detectors that can cover large areas for diffraction instruments and offer high efficiency and sub-millimeter spatial resolution. Photomultiplier Tube (PMT) based cameras are installed on three instruments at Spallation Neutron Source (SNS). The next generation camera uses Silicon Photomultipliers (SiPMs) instead of PMTs, which allows for a more compact design and higher spatial resolution. In this report, the Gaussian least-squares position fitting method is described in detail, as well as the method used to correct for geometric distortions across the face of the camera. Results from neutron camera tests before and after the distortion correction are shown and the spatial resolution is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron detector development for high-rate neutron reflectometry at the Second Target Station of Oak Ridge National Laboratory

The Second Target Station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) is expected to produce a neutron source that is the brightest in the world, having a significantly higher peak brightness compared to the First Target Station (FTS), where the reflectometry instruments already fall short of being able to handle the highest available flux by a factor of ~100. The neutron reflectometers at the SNS FTS are not suitable for the reflectometers planned for the SNS STS because of its unprecedentedly high peak brightness and the already limited capabilities of these instruments at high count rates. Furthermore, the high rate instruments that are now under development are expected to underperform with regard to gamma sensitivity, meaning that signal-to-noise will be reduced and they will be unable to measure weaker reflectance phenomena in the presence of the significant prompt gamma flash at SNS. To address these challenges, we conducted research to advances associated instruments, techniques, and capabilities for the SNS STS reflectometers. More specifically, we investigated the development of a scalable, 2-D positive-sensitive, pixelated, scintillator-based neutron detector module based on a newly developed scintillator. The work has potential for impact on future neutron reflectometry instruments and neutron science performed at the SNS STS. In particular, the improved background rejection capability of the developed detector could extend the available experimental dynamic Q range, allowing it to measure weak reflectance phenomena.

reflectometry, radiation instrumentation, neutron ↗

Design and structural assessment of the Spallation Neutron Source 2.0 MW target

The Proton Power Upgrade (PPU) project is underway at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. The project will double the proton accelerator power from 1.4 MW to 2.8 MW, increase power to the First Target Station (FTS), and enable a future Second Target Station (STS). The power increase partly comes from raising proton energy from 1.0 GeV to 1.3 GeV. The STS will operate at 0.7 MW at 15 Hz when completed. Until then, PPU will provide the capability to operate the FTS at 2.0 MW at 60 Hz. Maximum power at the FTS to date has been 1.4 MW at 60 Hz with 1.0 GeV protons. A new mercury target module design to operate reliably under PPU conditions has been completed after a multi-year effort. The design philosophy and assessment of the structural analysis are described here. This target underwent an unprecedented design and analysis process for SNS using the latest engineering techniques and incorporating years of operating lessons and outcomes from R&D to meet structural design criteria. Finally, it also incorporates high-flow gas injection to further mitigate pulse fatigue stresses as well as cavitation damage to the mercury vessel.

47 OTHER INSTRUMENTATION↗

Test cavity and Iris-to-Coax transition for tuning and high-power verification of SNS DTL iris couplers

The Spallation Neutron Source (SNS) Drift Tube Linac (DTL) employs iris couplers to efficiently deliver RF power into the accelerating structure. To support the development, tuning, and high‑power conditioning of these couplers prior to installation in the actual DTLs, a dedicated test cavity and an iris‑to‑coaxial transition structure have been designed. This work presents the electromagnetic design, simulation, and optimization of the test setup, enabling precise characterization of the iris coupler’s performance. The transition structure allows for tuning of the iris opening dimensions without requiring a waveguide taper or full‑size waveguide transitions, while maintaining impedance matching between the coaxial feed and the iris geometry to minimize reflection and power loss. During low‑power tests, the iris opening di-mensions can be evaluated using the iris‑to‑coax transi-tion attached to the test cavity. For high‑power condi-tioning, full‑size waveguides with ceramic vacuum win-dows are connected to the test cavity to replicate opera-tional conditions. Key design parameters were optimized using computer-aided simulation, and sensitivity studies were conducted to assess the impact of mechanical toler-ances on RF performance. The resulting test platform provides a reliable and efficient means for tuning and validating iris couplers, contributing to improved opera-tional stability in the SNS DTL.

Lee, Sung-Woo [ORNL] (ORCID:000000030915835X)↗

Installation and commissioning of the ion source systems for the new spallation neutron source 2.5 MeV injector

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world’s most intense pulsed neutron beams to a wide array of instruments, which are used to conduct investigations in many fields of engineering, physics, chemistry, material science, and biology. Neutrons are produced by spallation of liquid Hg by the bombardment of short (∼1 µs), intense (∼35 A) pulses of protons delivered at 60 Hz by an accumulator ring which is fed by a high-intensity, 1 GeV, H− LINAC (linear accelerator). This facility has operated nearly continuously since 2006 but has recently undergone a 4-month maintenance period, which featured a complete replacement of the 2.5 MeV injector feeding the LINAC. The new injector was developed at ORNL in an off-line beam test facility and consists of an ion source, low energy beam transport, and a Radio Frequency Quadrupole (RFQ). This report first describes the installed configuration of the new injector detailing the ion source system. The first beam current, RFQ transmission, emittance, and energy measurements from the injector installed on the SNS are reported. These data not only show a significant performance improvement for our existing facility but will also make accessible the higher beam current requirements for future SNS upgrade projects: the proton power upgrade and second target station.

Welton, R. F.↗

Design improvements to the SNS ion source and diagnostics

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed-neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. The accelerator system is fed by an RF-driven, multicusp, H - ion source which nominally provides pulsed beam currents of 50-60 mA (1ms, 60Hz). This report provides a discussion of ongoing design improvements to the SNS ion source and Low Energy Beam Transport (LEBT) as well as diagnostic upgrades undertaken since the previous ICIS conference. These improvements include (i) simple mechanical modifications to the source outlet aperture which resulted in dramatically increased extracted beam current and comparable or lower emittance at similar beam currents, (ii) design improvements to the LEBT chopper target which will enable full power beam-dumping during physics studies, (iii) refinement of the SNS Allison emittance scanner that has enabled the first reliable LEBT beam measurements at full beam power (65kV, 50-100mA, 1ms, 60Hz) on the SNS ion source test stand and (iv) the implementation of a thermal imaging camera for the monitoring the LEBT electrode temperatures. (v) The design of an advanced Cs system, capable of more efficient Cs utilization with significantly lower Cs losses from the source is also presented. Mechanical details, computational simulations and experimental results are discussed within the context of these improvements.

47 OTHER INSTRUMENTATION↗