Wide-Field Imaging Using Nitrogen Vacancies

Nitrogen vacancies in bulk diamonds and nanodiamonds can be used to sense temperature, pressure, electromagnetic fields, and pH. Unfortunately, conventional sensing techniques use gated detection and confocal imaging, limiting the measurement sensitivity and precluding wide-field imaging. Conversely, the present sensing techniques do not require gated detection or confocal imaging and can therefore be used to image temperature, pressure, electromagnetic fields, and pH over wide fields of view. In some cases, wide-field imaging supports spatial localization of the NVs to precisions at or below the diffraction limit. Moreover, the measurement range can extend over extremely wide dynamic range at very high sensitivity.

Englund, Dirk Robert↗

Ab initio Screening of Refractory Nitrides and Carbides for High Temperature Hydrogen Permeation Barriers

Density functional theory was used to screen eleven refractory materials – two pure metals, six nitrides, and three carbides–as high-temperature hydrogen permeation barriers to prevent hydrogen embrittlement. Activation energies were calculated for atomic hydrogen (H) diffusion into the first subsurface layer from the lowest energy surface of the high-temperature phase of each candidate material. The candidate barrier materials with the highest activation energies are h-BN, c-BN, HfN, and ZrN with predicted barriers of 3.25 eV, 3.23 eV, 3.14 eV, and 2.76 eV, respectively. Strain energies, Bader charges, and density of states were calculated for the diffusing H at the relaxed initial state and the transition state to provide insight into contributing factors to high energy barriers. The diffusing H atom in materials with the highest predicted barriers are protic. In addition, interstitial H atoms induce mid-gap states in the density of states of both BN polymorphs. The nitrogen retention of each nitride material at high temperatures was predicted using nitrogen vacancy formation energies with respect to gaseous nitrogen. Experimental evaluation of nitrogen retention in h-BN, ZrN, and TiN confirmed their resistance to nitrogen loss at 1773 K. However, of these nitrides, TiN is predicted to be the least stable. This work identifies multiple promising materials that are predicted to be effective hydrogen barriers at high temperatures and that are stable at temperatures above 2700 K, with BN predicted to perform best.

Density Functional Theory (DFT)↗

Accelerating the Deployment of Space-Based Quantum Sensors

Quantum sensors rely on quantum mechanical properties, such as wave-particle duality, atomic energy levels, or entanglement, to measure physical, optical, or electromagnetic information from a target. Examples include Rydberg sensors, nitrogen-vacancy magnetometers, HOM (Hong-Ou-Mandel) interferometers, and SQUIDs (Superconducting Quantum Interference Devices). In general, as quantum sensors rely on interrogation at the atomic and photonic level rather than on classical mechanical measurements, these technologies promise advantages over their traditional counterparts in sensitivity, accuracy, and SWaP (Size, Weight, and Power). Conceptually, the use of quantum sensors unlocks the new phenomenology of sensor entanglement. While an ultra-low TRL (Technology Readiness Level) prospect for most sensor types, multi-sensor entanglement is a high risk, high reward strategy with a potential for exquisite sensitivity and SWaP improvements entirely inaccessible to classical sensors.

Grace Caroline Wusk↗

Vacancy Mediated Mechanism of Nitrogen Substitution in Carbon Nanotubes

Nitrogen substitution reaction in a graphene sheet and carbon nanotubes of different diameter are investigated using the generalized tight-binding molecular dynamics method. The formation of a vacancy in curved graphene sheet or a carbon nanotube is found to cause a curvature dependent local reconstruction of the surface. Our simulations and analysis show that vacancy mediated N substitution (rather than N chemisorption) is favored on the surface of nanotubes with diameter larger than 8 nm. This predicted value of the critical minimum diameter for N incorporation is confirmed by experimental results presented.

Srivastava, Deepak↗

Magnetism of Carbonados

Carbonados are porous polycrystalline (with crystal sizes up to 100 micrometer) diamonds. Carbonado is found only in alluvial deposits in Bahia, Brazil and in the Central African Republic (CAR). Alluvial deposit host is 1.5 Ga while the carbonados are between 2.6 - 3.8 Ga. The process of fusing the carbonado microcrystals together is not fully understood, partly due to fact that the origin of these carbonado, is not known. Several modes of origins are proposed for carbonado. First, a crustal origin. Carbonados have a light carbon and helium isotopic signature. They contain an enrichment of the rare-earth elements (REE). Carbonados have tightly trapped atmospheric noble gases and contain an evidence of high He content despite the carbonado expected depletion of He at mantle temperatures. Carbonados have high porosity incompatible with high pressure mantle conditions. Second, a mantle origin is proposed based on similar REE pattern to kimberlites. The presence of nitrogen platelet (by IR spectra) indicates high temperature origin and syngenetic inclusions of rutile, ilmenite, and magnetite indicates high pressure and high temperature conditions consistent with mantle origin as well. Third, it is proposed that carbonado diamonds are a result of early impacts into crustal rocks. This is indicated by the rare and controversial occurrence of high pressure diamond polymorph, londsdaleite, frequently found in diamonds from meteorite impact sites, and by observation of planar deformation features, possibly indicating shock events. Finally, it is suggested that carbonados have an extraterrestrial origin, as indicated by a long term annealing based on observation of a zero-phonon line, attributed to paired nitrogen atoms in association with a vacancy.

Kletetschka, G.↗

Electronic Structure of TlBa2CaCu2O(7-Delta)

The core levels of TlBa2CaCu2O(7-delta) (Tl-1212) epitaxial films have been measured with X-ray photoelectron spectroscopy (XPS). The valence electronic structure has been determined using the full-potential linear muffin-tin-orbital band-structure method and measured with XPS. The calculations show that a van Hove singularity (VHS) lies above the Fermi level (E(sub F)) for the stoichiometric compound (delta = 0.5), while for 50% oxygen vacancies in the Tl-O layer (delta = 0.5) E(sub F) is in close proximity to the VHS. Samples annealed in nitrogen (to reduce the hole overdoping by the removal of oxygen) exhibit higher core-level binding energies and a higher T(sub c), consistent with a shift of E(sub F) closer to the VHS. Comparisons are made to the core levels and valence bands of Tl2Ba2CaCu2O(8 + delta)(Tl-2212) and HgBa2CaCu2O)6 + delta) (Hg- 1212). The similarity of the Cu 2p(sub 3/2) spectra for Tl-1212 and Tl-2212 indicates that the number of Tl-O layers has little effect on the Cu-O bonding. However, the Tl-1212 and Hg-1212 Cu 2p(sub 3/2) signals exhibit differences which suggest that the replacement of T(sup 3+) with Hg(sup 2+) results in a decrease in the O 2p right arrow Cu 3d charge-transfer energy and differences in the probabilities of planar vs apical oxygen charge transfer and/or Zhang-Rice singlet-state formation. Differences between the Tl-1212 and the Tl-2212 and Hg-1212 measured valence bands are consistent with the calculated Cu 3d and (Tl,Hg) 6s/5d partial densities of states.

Vasquez, R. P.↗

Dependence of the cathodoluminescence of diamond films on deposition temperature

The deposition temperature dependence of the cathodoluminescence (CL) of diamond thin films grown by microwave-plasma-assisted chemical vapor deposition has been investigated. Depositions were made in the temperature range of 400 to 750 C at a pressure of 10 Torr, with a gas mixture of 5 percent CH4 and 5 percent O2 in hydrogen. The intensity of the luminescent peak at 430 nm was used as a measure of diamond quality for the film. This peak was found to be a maximum above 600 C. Examination of the intensities of CL emissions associated with nitrogen and silicon impurities at 530, 560, and 740 nm indicate incorporation of these impurities is more efficient at temperatures above 600 C. Film quality was thus found to be an optimization of competing mechanisms, i.e., improvement of diamond quality as evidenced by the intensity of the 430 nm peak, with the apparent activation of impurities and vacancy defects at elevated temperatures.