Search NASA⌕ Search

SEARCH · Search NASA

Results for “noise reduction methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Noise reduction methods for nucleic acid and macromolecule sequencing

Methods, systems, and devices are disclosed for processing macromolecule sequencing data with substantial noise reduction. In one aspect, a method for reducing noise in a sequential measurement of a macromolecule comprising serial subunits includes cross-correlating multiple measured signals of a physical property of subunits of interest of the macromolecule, the multiple measured signals including the time data associated with the measurement of the signal, to remove or at least reduce signal noise that is not in the same frequency and in phase with the systematic signal contribution of the measured signals.

59 BASIC BIOLOGICAL SCIENCES↗

Aeroacoustic Assessment of Wind Plant Controls

The Aeroacoustic Assessment project aims to quantify changes in aeroacoustic noise generation by a utility scale wind turbine operating under imposed yaw offsets common for wake steering and wind plant control strategies. Active plant control utilizing wake deflection control strategies have been shown experimentally and computationally to reliably produce 1-2% of additional annual energy production (AEP) without significant changes in turbine structural loads, the potential impact on aeroacoustic emissions has yet to be quantified or completely understood. Yawed operation of a wind turbine changes the three-dimensional aerodynamic interaction between the rotor blades and the incoming atmospheric flow, leading to changes in noise generation. This work quantifies the extent to which active control induces additional aeroacoustic emissions from additional separation and other flow interaction dynamic effects. Given public concerns about wind turbine noise and the need for observational data required for regulators to establish noise restrictions, we must understand potential acoustic emissions resulting from active control prior to commercial deployment and the development of practical noise reduction methods and technologies. The work outlined in this report details the new aeroacoustic measurement capability developed at NREL and its application to making full-field observations of noise from a utility-scale wind turbine. Preliminary noise modeling with the aeroacoustics module in OpenFAST helped to establish the design of the experiment, specifically targeting the noise observed at observers distributed around the DOE-owned GE 1.5 MW wind turbine. Low-frequency and infrasound measurement capability implemented in this project establish an operational baseline for the wind turbine, setting the stage for future control, rotor blade, and turbine design research.

17 WIND ENERGY↗

The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment

Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ( 0νββ ) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here, we report the detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for 0νββ decay with mK-scale calorimeters, and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE’s energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to 0νββ decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.

experimental nuclear physics↗

Comparison of Infrasound Wind Noise Reduction Systems for Use in Temporary Deployments

Infrasound, or low frequency sound 20 Hz, is produced by a variety of natural and anthropogenic sources. Wind also generates signals within this frequency band and serves as a persistent source of infrasonic noise. Infrasound sensors measure pressure fluctuations, which scale with the ambient density and velocity fluctuations of ground winds. Here we compare four different wind noise reduction systems, or "filters", and make recommendations for their use in temporary infrasound deployments. Our results show that there are two filters that are especially effective at reducing wind noise: (1) a Hyperion high frequency (HF) shroud with a 1 m diameter metal mesh dome placed on top and (2) a Hyperion Four Port Garden Hose shroud with 4 Miracle-Gro Soaker System garden hoses. We also find that placing a 5-gallon bucket over the HF wind shroud should not be done as it provides a negligible decrease in noise up to ~ 1 Hz and then an increase in noise. We conclude that it is up to the researcher to determine which of the other filters is best for their needs based on location and expense. We anticipate this study will be used as a resource for future deployments when a wind noise reduction method is necessary but only needed for a limited time period.

58 GEOSCIENCES↗

A novel method for thermal noise reduction, enabling measurements of broadband, low-amplitude electron temperature fluctuations using individual radiometer channels

A new analysis method has been developed for measurements of broadband, low-amplitude turbulent electron temperature fluctuations in fusion plasmas using individual radiometer channels of a correlation electron cyclotron emission diagnostic. This method takes advantage of differences in the correlation time of thermal noise compared to the correlation time of plasma fluctuations in fusion reactors. The validation of this single-channel method is demonstrated using comparisons with the standard dual-channel radiometer spectral decorrelation method for measurements of turbulent electron temperature fluctuations in the core and edge of low confinement (L), improved confinement (I), and high confinement (H)-mode plasmas at the ASDEX Upgrade tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam Loss Assessment Through Use of Photomultiplier Tubes

The first machine in the Fermilab Accelerator chain, the Linac, delivers a 400 MeV proton beam. The first portion of the Fermilab Linac, the Drift Tube Linac, lacks the degree of instrumentation necessary for beam tuning. To compensate for this, photomultiplier tube (PMT s) based loss monitors were installed on either side of the first two drift tube tanks, but are not yet operational. One of the main goals in this is to make PMT's operational beam loss monitors for tuning. Noise reduction and peak finding on the PMT data is a requirement for this. A method for noise reduction and peak finding has been developed and implemented to produce a consistent and stable output. Future work includes integration with ACNET to automate input and output of data for analysis of beam loss.

Waggoner, Alexander↗

Optimization Methods for Large-Scale Machine Learning

Here this paper provides a review and commentary on the past, present, and future of numerical optimization algorithms in the context of machine learning applications. Through case studies on text classification and the training of deep neural networks, we discuss how optimization problems arise in machine learning and what makes them challenging. A major theme of our study is that large-scale machine learning represents a distinctive setting in which the stochastic gradient (SG) method has traditionally played a central role while conventional gradient-based nonlinear optimization techniques typically falter. Based on this viewpoint, we present a comprehensive theory of a straightforward, yet versatile SG algorithm, discuss its practical behavior, and highlight opportunities for designing algorithms with improved performance. This leads to a discussion about the next generation of optimization methods for large-scale machine learning, including an investigation of two main streams of research on techniques that diminish noise in the stochastic directions and methods that make use of second-order derivative approximations.

97 MATHEMATICS AND COMPUTING↗

Machine learning pipeline for denoising low signal-to-noise ratio and out-of-distribution transmission electron microscopy datasets

High-resolution transmission electron microscopy (HRTEM) is crucial for observing material’s structural and morphological evolution at Angstrom scales, but the electron beam can alter these processes. Devices such as CMOS-based direct-electron detectors operating in electron-counting mode can be utilized to substantially reduce the electron dosage. However, the resulting images often lead to a low signal-to-noise ratio, which requires frame integration that sacrifices temporal resolution. Several machine learning (ML) models have been recently developed to successfully denoise HRTEM images. Yet, these models are often computationally expensive, and their inference speeds on GPUs are outpaced by the imaging speed of advanced detectors, precluding in situ analysis. Furthermore, the performance of these denoising models on datasets with imaging conditions that deviate from the training datasets has not been evaluated. To mitigate these gaps, we propose a new self-supervised ML denoising pipeline specifically designed for time-series HRTEM images. This pipeline integrates a blind-spot convolution neural network with pre-processing and post-processing steps, including drift correction and low-pass filtering. Results demonstrate that our model outperforms various other ML and non-ML denoising methods in noise reduction and contrast enhancement, leading to improved visual clarity of atomic features. Additionally, the model is drastically faster than U-Net-based ML models and demonstrates excellent out-of-distribution generalization. The model’s computational inference speed is in the order of milliseconds per image, rendering it suitable for application in in-situ HRTEM experiments.

36 MATERIALS SCIENCE↗

Common-mode noise reduction with impedance balancing in DC-fed motor drives

Unlike conventional passive or active filters, an impedance balancing circuit reduces the common-mode (CM) electromagnetic interference (EMI) noise by establishing an impedance balancing bridge. The EMI noise can be significantly reduced when the impedance bridge is designed to be well balanced. This paper investigates impedance balancing circuits in Dc-fed motor drive systems where both DC input and AC output need to meet EMI standards and thus EMI filters are needed for both sides. An impedance balancing circuit is proposed to reduce both DC and AC side CM noise. Two auxiliary branches are added to the conventional passive filters to establish an impedance bridge and reduce CM noise. The design criteria are presented, and the impact of the proposed impedance balancing circuit on both sides CM noise are investigated. It shows that the proposed impedance balancing circuit can reduce DC side and AC side CM noise based on different mechanisms. The CM noise reduction performance of the proposed method does not depend on the motor and cable models. Experiment results are presented to demonstrate the feasibility and effectiveness of the proposed method.

Chen, Ruirui↗

Automated quantum error mitigation based on probabilistic error reduction

Current quantum computers suffer from a level of noise that prohibits extracting useful results directly from longer computations. The figure of merit in many near-term quantum algorithms is an expectation value measured at the end of the computation, which experiences a bias in the presence of hardware noise. A systematic way to remove such bias is probabilistic error cancellation (PEC). PEC requires a full characterization of the noise and introduces a sampling overhead that increases exponentially with circuit depth, prohibiting high-depth circuits at realistic noise levels. Probabilistic error reduction (PER) is a related quantum error mitigation method that systematically reduces the sampling overhead at the cost of reintroducing bias. In combination with zero-noise extrapolation, PER can yield expectation values with an accuracy comparable to PEC.Noise reduction through PER is broadly applicable to near-term algorithms, and the automated implementation of PER is thus desirable for facilitating its widespread use. To this end, we present an automated quantum error mitigation software framework that includes noise tomography and application of PER to user-specified circuits. We provide a multi-platform Python package that implements a recently developed Pauli noise tomography (PNT) technique for learning a sparse Pauli noise model and exploits a Pauli noise scaling method to carry out PER.We also provide software tools that leverage a previously developed toolchain, employing PyGSTi for gate set tomography and providing a functionality to use the software Mitiq for PER and zero-noise extrapolation to obtain error-mitigated expectation values on a user-defined circuit.

McDonough, Benjamin↗

Methods of improving spatial resolution for IR spectroscopy in atmospheric-pressure plasma systems

High-temperature, atmospheric pressure plasma systems operated in molecular gases present complex diagnostic challenges. Infrared spectroscopy has been used to make measurements of the absorbance spectrum of complex molecular gas mixtures and thereby calculate the concentrations and species temperatures in these systems. For atmospheric-pressure systems, high spatial gradients arise and high spatial-resolution measurements are thus desirable. Some systems have achieved increased spatial resolution by reducing the beam diameter. However, this increase in spatial resolution comes at the expense of the optical throughput. Here we propose modifying a commercial Fourier Transform, Infrared spectrometer system with a set of simple optical elements. This design allows for scannable, high spatial resolution absorbance spectrum measurements of a complex molecular gas mix. We analyze the signal-to-noise ratio for this design and compare it with the diameter reduction method. For sufficiently low plasma radiation levels, this design improves the signal-to-noise ratio relative to reducing the beam diameter size while transmitting nearly all of the beam power. Furthermore, whether this design can achieve the desired sub-mm spatial resolution depends on the radiating area of the infrared light source in the spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EUTERPE: A global gyrokinetic code for stellarator geometry

The current state of the EUTERPE code is described with emphasis on the implemented models and their numerical implementation. The code solves the multi-species electromagnetic gyrokinetic equations in the full volume of a three-dimensional domain. Noise reduction of the particle-in-cell method is achieved by using a δf-method and Fourier filters. The field equations are discretized with B-splines and the resulting system of equations is solved iteratively. For linear simulations a phase-factor transformation is applied in order to strongly reduce the necessary grid resolution. Apart from the full gyrokinetic model, other numerically less expensive hybrid models are also implemented. They are mainly tailored for comparison with fluid theory and for studying the interaction of the bulk plasma with fast particles. The code is parallelized for CPUs by particle and domain decomposition. Good scalability up to several thousand nodes is demonstrated.

97 MATHEMATICS AND COMPUTING↗

Parametrized process characterization with reduced resource requirements

Quantum process tomography (QPT) is a powerful tool to characterize quantum operations, but it requires considerable resources, making it impractical for more than two-qubit systems. This study proposes an alternative approach that requires significantly fewer resources for unitary process characterization with a built-in method for state preparation and measurement error mitigation. By measuring the quantum process as rotated through the X and Y axes on the Bloch sphere, we can acquire enough information to reconstruct the quantum process matrix χ and measure its fidelity. We test the algorithm's performance against standard QPT using simulated and physical experiments on several IBM quantum processors and compare the resulting process matrices. We demonstrate with numerical experiments that the method can improve gate fidelity via a noise reduction in the imaginary part of the process matrix, along with a stark decrease in the number of experiments needed to perform the characterization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ midcircuit qubit measurement and reset in a single-species trapped-ion quantum computing system

We implement in situ midcircuit measurement and reset (MCMR) operations on a full-scale trapped-ion quantum computing system by using metastable qubit states in 171 Yb + ions. We compare two methods for isolating data qubits from measured qubits: one shelves the data qubits into the metastable state and the other drives the measured qubit to the metastable state without disturbing the other qubits. We experimentally demonstrate both methods on a crystal of two 171 Yb + ions using both the 𝑆 1/2 ground-state hyperfine clock qubit and the 𝑆 1/2 −𝐷 3/2 optical qubit. These MCMR methods result in errors on the data qubit of about 2% without degrading the measurement fidelity. With straightforward reductions in laser noise, these errors can be suppressed to less than 0.1%. The demonstrated methods allow MCMR to be performed in a single-species ion chain without shuttling or additional qubit-addressing optics, greatly simplifying the system architecture and allowing straightforward integration with existing trapped-ion quantum computers.

coherent control↗

In-situ mid-circuit qubit measurement and reset in a single-species trapped-ion quantum computing system

We implement in-situ mid-circuit measurement and reset (MCMR) operations on a trapped-ion quantum computing system by using metastable qubit states in $^{171}\textrm{Yb}^+$ ions. We introduce and compare two methods for isolating data qubits from measured qubits: one shelves the data qubit into the metastable state and the other drives the measured qubit to the metastable state without disturbing the other qubits. We experimentally demonstrate both methods on a crystal of two $^{171}\textrm{Yb}^+$ ions using both the $S_{1/2}$ ground state hyperfine clock qubit and the $S_{1/2}$-$D_{3/2}$ optical qubit. These MCMR methods result in errors on the data qubit of about $2\%$ without degrading the measurement fidelity. With straightforward reductions in laser noise, these errors can be suppressed to less than $0.1\%$. The demonstrated method allows MCMR to be performed in a single-species ion chain without shuttling or additional qubit-addressing optics, greatly simplifying the architecture.

Atomic Physics (physics.atom-ph)↗

Abstract for CRADA among NETL, Mälardalen University, University College Cork (acting through its Tyndall National Institute), and Micro Electricity Generation Association

GeoCoHorT aims to accelerate the transition to 4 th generation district heating and cooling (4GDHC) in Europe and globally, by assessing, optimizing, and demonstrating the integration of shallow geothermal heat extraction with other renewable sources and smart buildings. The target geo-source is ground water from River Shannon (Limerick, Ireland), which will provide both an efficiency and noise-reduction benefit to the micro-district and a method of combatting climate-change-warming of the Shannon Estuary. The heat from this low-temperature source will be recycled and supplied to a smart district located in Limerick, Ireland, through heat pumps powered by renewable electricity and by means of a suitable DH network design. The mandate is to find solutions that work for entire communities in a fair and sustainable manner, with the involvement of the communities themselves to highlight their needs. The project brings together four partners from Ireland, Sweden, and the U.S.A. with strong multi-disciplinary competencies. The Tyndall Institute at University of Cork (UCC) and Mälardalen University (MDU) will design and optimize the 4GDH micro-district system, and the Micro Electricity Generation Association (MEGA) will work with the community to build a sense of ownership of the Climate Challenge and ensure close community involvement. The National Energy Technology Laboratory of the U.S. Department of Energy (NETL) will design the prospective geo-fluid loop to optimize heat-extraction effectiveness with ecological safety and assess the environmental benefits of the proposed solutions. Industrial advisors (Eskilstuna Strängnäs Energi och Miljö (ESEM) and Mimer in Sweden, and Smart MPOWER in Ireland) will steer the technology development to meet the needs of public utilities and consumers. Current infrastructure in the smart district in Limerick (demonstration site of an EU Lighthouse project) will be exploited and modified with support of MEGA, UCC, and MPOWER to integrate micro-DH from low-temperature heat sources, such as the river heat, and to allow increasing penetration of prosumers in the grid. Additional case studies will be developed with the help of industrial advisors to extend the results to other regions (e.g., Sweden and USA) and provide valuable insights for the development of 4GDH worldwide.

15 GEOTHERMAL ENERGY↗

Multiscale Characterization of Additive Manufacturing Components with Computed Tomography, 3D X-ray Microscopy, and Deep Learning

Additive manufacturing (AM) facilitates the creation of complex-geometry parts, driving advancements in lightweight aerospace components, high-efficiency engine cooling channels, and customized medical implants. However, ensuring the quality and reliability of AM parts remains challenging due to internal defects, surface irregularities, porosity, and residual trapped powder, which are often inaccessible to traditional inspection methods. Recent developments in X-ray computed tomography (XCT) and 3D X-ray microscopy (XRM), particularly systems equipped with resolution-at-a-distance (RaaD™) capabilities, enable high-resolution, non-destructive evaluation of AM components across multiple scales, from sub-micrometer to macroscopic levels. This paper explores modern XCT and XRM techniques for multiscale characterization of AM parts, focusing on their ability to detect and analyze defects such as porosity, cracks, inclusions, and surface roughness, while offering insights into defect formation mechanisms, material properties, and process-induced variations. The integration of deep learning (DL) frameworks, including Simurgh, DeepRecon, and DeepScout, enhances XCT/XRM workflows by reducing scan times, improving resolution recovery, and enabling accurate defect detection even with limited projection data. These DL-based methods overcome limitations of traditional reconstruction techniques, enabling faster, more reliable characterization of dense materials like Inconel 718 and novel alloys such as AlCe. Applications include process parameter optimization, high-throughput quality control, and multistage AM process evaluation, with DL-enhanced workflows accelerating analysis times from weeks to days. Correlative imaging approaches further validate XCT and XRM data against scanning electron microscopy (SEM) images of physically sectioned samples, confirming the accuracy of DL-based reconstructions and enabling comprehensive defect analysis. While challenges remain in generalizing DL models to diverse materials and imaging conditions, improvements in resolution, noise reduction, and defect detection highlight the transformative potential of these methods. This multiscale and correlative approach enables precise identification and correlation of microstructural features with the overall performance of AM components. By integrating advanced XCT, XRM, and DL techniques, this paper demonstrates a significant leap forward in AM characterization, offering valuable insights into the relationships between processing parameters, microstructure, and part performance, and driving innovations that enhance the quality and reliability of AM products for demanding industrial applications.

Additive manufacturing↗

Comparison of image noise and image quality between full-dose abdominal computed tomography scans reconstructed with weighted filtered back projection and half-dose scans reconstructed with improved sinogram-affirmed iterative reconstruction (SAFIRE*)

Purpose: To retrospectively compare the image noise, signal-to-noise ratio (SNR), and subjective image quality between CT images acquired with a dual-source, split-dose imaging protocol reconstructed at full and half doses with weighted filtered back projection (wFBP) and an improved sinogram-affirmed iterative reconstruction algorithm (SAFIRE*). Methods: Fifty-three consecutive patients underwent contrast-enhanced CT of the abdomen using a standardized dual-source, single energy CT protocol. Half-dose images were retrospectively generated using data from one detector only. Full-dose datasets were reconstructed with wFBP, while half-dose datasets were reconstructed with wFBP and SAFIRE* strengths 1–5. Region of interest analysis was performed to assess SNR and noise. Diagnostic acceptability, subjective noise, and spatial resolution were graded on a 10-point scale by two readers. Statistical analysis was carried out with repeated measures analysis of variance, Wilcoxon signed rank test, and Cohen’s κ test. Results: With the increasing strengths of SAFIRE*, a progressive reduction in noise and increase in SNR (p < 0.01) was observed. There was a statistically significant decrease in objective noise and increase in SNR in half-dose SAFIRE* strength 4 and 5 reconstructions compared to full-dose reconstructions using wFBP (p < 0.01). Qualitative analysis revealed a progressive increase in diagnostic acceptability, decrease in subjective noise and increase in spatial resolution for half-dose images reconstructed with the increasing strengths of SAFIRE* (p < 0.01). Conclusions: Half-dose CT images reconstructed with SAFIRE* at strength 4 and 5 have superior image quality compared to full-dose images reconstructed with wFBP. SAFIRE* potentially allows dose reductions in the order of 50% over wFBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗