The detection of tightly closed flaws by nondestructive testing (NDT) methods

Liquid penetrant, ultrasonic, eddy current and X-radiographic techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens in integrally stiffened panel, and weld panel configurations. Fatigue cracks in integrally stiffened panels, lack-of-fusion in weld panels, and fatigue cracks in weld panels were the flaw types used for evaluation. A 2319 aluminum alloy weld filler rod was used for all welding to produce the test specimens. Forty seven integrally stiffened panels containing a total of 146 fatigue cracks, ninety three lack-of-penetration (LOP) specimens containing a total of 239 LOP flaws, and one-hundred seventeen welded specimens containing a total of 293 fatigue cracks were evaluated. Nondestructive test detection reliability enhancement was evaluated during separate inspection sequences in the specimens in the 'as-machined or as-welded', post etched and post proof loaded conditions. Results of the nondestructive test evaluations were compared to the actual flaw size obtained by measurement of the fracture specimens after completing all inspection sequences. Inspection data were then analyzed to provide a statistical basis for determining the flaw detection reliability.

Rummel, W. D.↗

Detection of tightly closed flaws by nondestructive testing (NDT) methods in steel and titanium

X-radiographic, liquid penetrant, ultrasonic, eddy current and magnetic particle testing techniques were optimized and applied to the evaluation of 4340 steel (180 KSI-UTS) and 6Al-4V titanium (STA) alloy specimens. Sixty steel specimens containing a total of 176 fatigue cracks and 60 titanium specimens containing a total of 135 fatigue cracks were evaluated. The cracks ranged in length from .043 cm (0.017 inch) to 1.02 cm (.400 inch) and in depth from .005 cm (.002 inch) to .239 cm (.094 inch) for steel specimens. Lengths ranged from .048 cm (0.019 inch) to 1.03 cm (.407 inch) and depths from 0.010 cm (.004 inch) to .261 cm (0.103 inch) for titanium specimens. Specimen thicknesses were nominally .152 cm (0.060 inch) and 0.635 cm (0.250 inch) and surface finishes were nominally 125 rms. Specimens were evaluated in the "as machined" surface condition, after etch surface and after proof loading in a randomized inspection sequence.

Rummel, W. D.↗

STA-2A NDT testing

The nondestructive testing (NDT) on the Space Shuttle Solid Rocket Booster (SRB) filament wound case (FWC) short stact structural test articles 2 (STA-2A) during test of phases 1B-9C is described. The primary objective of this testing was to verify the structural integrity of the SRB-FWC for critical design loads. Another objective was to quantify the effect of load distributions in the aft skirt. The NDT objectives were to determine the acoustic emission characteristics of the FWC-SRB and to identify possible design deficiencies or defect growth. The results from the posttest inspection of the samples shows the depth measurements taken were accurate until exceeding .260 inches thickness. The data then show that pulse echo measurements exceeded actual part thickness by 10 to 14 percent. The mapping of forward boundaries of delaminations proved to be within the tolerance of the equipment. Using the ZIP probe, the maximum difference between the pulse echo boundary and the visual boundary was expected to be no greater than one half the diameter of the probe. The NDT performance on STA-2A shows how NDT can be used to assist design engineering in evaluating the structural integrity of composite test articles.

Lewis, T. J.↗

Non-destructive Testing (NDT) of metal cracks using a high Tc rf-SQUID and eddy current method

A SQUID is the most sensitive device to detect change in magnetic field. A nondestructive testing (NDT) device using high temperature SQUID's and eddy current method will be much more sensitive than those currently used eddy current systems, yet much cheaper than one with low temperature SQUID's. In this paper, we present our study of such a NDT device using a high temperature superconducting rf-SQUID as a gradiometer sensor. The result clearly demonstrates the expected sensitivity of the system, and indicates the feasibility of building a portable HTS SQUID NDT device with the help from cryocooler industry. Such a NDT device will have a significant impact on metal corrosion or crack detection technology.

Lu, D. F.↗

NDT of DC-10 graphite-epoxy rudder

The results of visual and ultrasonic nondestructive tests (NDT) on a DC-10 rudder constructed of Thornel 300/5208 graphite-epoxy are presented. A viscous couplant was used for both contact pulse-echo ultrasonics and the Fokker bondtester. Attention is given to the stiffness of cohesive bond structures (the rudder is assembled primarily in a basic six-ply pattern), and to possible delamination. A piezoelectric transducer is employed to sense changes in impedance and signal amplitude. In all, four rudder units were evaluated. The main problems found in the units were porosity and cracking. It is noted that rudder unit four was able to be sufficiently cured to permit static tests on all rib, spar, and skin panel interfaces.

Hagemaier, D. J.↗

NDT and SHM of Carbon Fiber Composites using Linear Drive MWM-Arrays

Carbon fiber composites are used in a wide range of structural applications due to their excellent specific strength and stiffness. However, the anisotropic mechanical and electrical properties associated with the fibers within each composite layer present challenges, and opportunities, for Nondestructive Testing (NDT) methods used to characterize and assess the structure condition. This includes composite condition after manufacture (such as fiber orientation and density, porosity, delamination, and bond strength) and during usage (such as damage from impact, fiber breakage, thermal exposure or applied stress). Ultrasonic and thermographic methods can address some of these challenges, but eddy current methods provide an alternative method for composite structures that contain a conducting material, such as carbon fibers or a metallic liner. This presentation reviews recent advances in the development of eddy current sensors and arrays for carbon fiber composite NDT and Structural Health Monitoring (SHM) applications. The focus is on eddy current sensor constructs with linear drive windings, such as MWM -Arrays, that induce currents primarily within the linear fibers of the composite. By combining this type of sensor construct with micromechanical models that relate composite constituent properties to measurable sensor responses, insight is obtained into the volumetric distribution of electrical properties within the composite and the associated manufacturing, damage, or strain conditions. With knowledge of the fiber layup, this MWM-Array technology is able to detect damage and strain/stress as a function of depth and fiber orientation. This work has been funded by NASA, NA V AIR and the Army for applications ranging from composite overwrapped pressure vessels (COPVs) to aircraft structures and rotorcraft blades. This presentation will specifically present background on the MWM-Array technology, results from the micromechanical modeling effort, and results from ongoing efforts for high resolution imaging and volumetric strain sensing.

Washabaugh, Andrew↗

Assessment of and standardization for quantitative nondestructive test

Present capabilities and limitations of nondestructive testing (NDT) as applied to aerospace structures during design, development, production, and operational phases are assessed. It will help determine what useful structural quantitative and qualitative data may be provided from raw materials to vehicle refurbishment. This assessment considers metal alloys systems and bonded composites presently applied in active NASA programs or strong contenders for future use. Quantitative and qualitative data has been summarized from recent literature, and in-house information, and presented along with a description of those structures or standards where the information was obtained. Examples, in tabular form, of NDT technique capabilities and limitations have been provided. NDT techniques discussed and assessed were radiography, ultrasonics, penetrants, thermal, acoustic, and electromagnetic. Quantitative data is sparse; therefore, obtaining statistically reliable flaw detection data must be strongly emphasized. The new requirements for reusable space vehicles have resulted in highly efficient design concepts operating in severe environments. This increases the need for quantitative NDT evaluation of selected structural components, the end item structure, and during refurbishment operations.

Neuschaefer, R. W.↗

The detection of fatigue cracks by nondestructive testing methods

X-radiographic penetrant, ultrasonic, eddy current, holographic, and acoustic emission techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens. One hundred eighteen specimens containing a total of 328 fatigue cracks were evaluated. The cracks ranged in length from 0.500 inch (1.27 cm) to 0.007 inch (0.018 cm) and in depth from 0.178 inch (0.451 cm) and 0.001 inch (0.003 cm). Specimen thicknesses were nominally 0.060 inch (0.152 cm) and 0.210 inch (0.532 cm) and surface finishes were nominally 32 and 125 rms and 64 and 200 rms respectively. Specimens were evaluated in the as-milled surface condition, in the chemically milled surface condition and, after proof loading, in a randomized inspection sequence. Results of the nondestructive test (NDT) evaluations were compared with actual crack size obtained by measurement of the fractured specimens. Inspection data was then analyzed to provide a statistical basis for determinating the threshold crack detection sensitivity (the largest crack size that would be missed) for each of the inspection techniques at a 95% probability and 95% confidence level.

Rummel, W. D.↗

NASA CR-2120 - Summary of nondestructive testing theory and practice

This is a familiarization report of nondestructive testing (ndt) prepared by staff of the Battelle Columbus Laboratories on a NASA contract. There is a short introduction, a chapter on applicability of ndt which is illustrated with examples of typical defects and includes tables comparing the characteristics, interrelationships, and costs of the different techniques. There are chapters dealing with penetrants, magnetic particle radiography, ultrasonics, and eddy currents. New techniques are described.

Meister, R. P.↗

Assessment of NDE reliability data

Twenty sets of relevant nondestructive test (NDT) reliability data were identified, collected, compiled, and categorized. A criterion for the selection of data for statistical analysis considerations was formulated, and a model to grade the quality and validity of the data sets was developed. Data input formats, which record the pertinent parameters of the defect/specimen and inspection procedures, were formulated for each NDE method. A comprehensive computer program was written and debugged to calculate the probability of flaw detection at several confidence limits by the binomial distribution. This program also selects the desired data sets for pooling and tests the statistical pooling criteria before calculating the composite detection reliability. An example of the calculated reliability of crack detection in bolt holes by an automatic eddy current method is presented.

Yee, B. G. W.↗

Solid rocket motor nozzles

The steps in the nozzle design process are examined. The nozzle designer's role in defining design requirements and constraints is included along with discussions of each of the three basic phases of the nozzle design process itself: (1) aerodynamic design, in which the gas-contacting surfaces are configured to produce the required performance within the envelope limits; (2) thermal design, in which termal liners and thermal insulators are selected and configured to maintain the surfaces as closely as practical against effects of erosion and to limit the structure temperature to acceptable levels; and (3) structural design, in which materials are selected and configured to support the thermal components and to sustain the predicted loads. Analytical techniques that are used to establish thermal and structural design integrity and to predict nozzle performance are discussed along with methods for nozzle quality assurance. Emphasis is placed on nozzle design and materials for modern high-temperature aluminized propellants. Recurring nozzle design problems of graphite cracking and ejection, differential erosion at material interfaces, lack of sufficient proven nondestructive testing (NDT) techniques, the uncertainty of adhesive bonding, and inadequate definition of material properties, particularly at high temperatures are considered.

Ellis, R. A.↗

Current and future developments in civil aircraft non-destructive evaluation from an operator's point of view

In June, 1988, the first International Conference on aging aircraft was held to address nondestructive tests (NDT) of aging aircraft and other issues. From this meeting, a research program was initiated and funded by the FAA. As a result of this program, a lot of work has been done to study current NDT practices in the aviation industry and secondly, to research and develop new NDT methods to improve the reliability and efficiency of in-service inspection of aircraft structures and powerplants. The following is an overview of the current and future developments in civil aircraft NDT, as viewed by an air carrier and the concerns for NDT in the future.

Aging Aircraft↗

Millimeter Wave Detection of Localized Anomalies in the Space Shuttle External Fuel Tank Insulating Foam and Acreage Heat Tiles

The Space Shuttle Columbia's catastrophic accident emphasizes the growing need for developing and applying effective, robust and life-cycle oriented nondestructive testing (NDT) methods for inspecting the shuttle external fuel tank spray on foam insulation (SOFI) and its protective acreage heat tiles. Millimeter wave NDT techniques were one of the methods chosen for evaluating their potential for inspecting these structures. Several panels with embedded anomalies (mainly voids) were produced and tested for this purpose. Near-field and far-field millimeter wave NDT methods were used for producing millimeter wave images of the anomalies in SOFI panel and heat tiles. This paper presents the results of an investigation for the purpose of detecting localized anomalies in two SOFI panels and a set of heat tiles. To this end, reflectometers at a relatively wide range of frequencies (Ka-band (26.5 - 40 GHz) to W-band (75 - 110 GHz)) and utilizing different types of radiators were employed. The results clearly illustrate the utility of these methods for this purpose.

Kharkovsky, S.↗

Inspection of the Space Shuttle External Tank SOFI Using Near-Field and Focused Millimeter Wave Nondestructive Testing Techniques

The Space Shuttle Columbia's catastrophic failure has been attributed to a piece of external tank SOFI (Spray On Foam Insulation) striking the left wing of the orbiter causing significant damage to some of the reinforced carbon/carbon leading edge wing panels. Subsequently, several nondestructive testing (NDT) techniques have been considered for inspecting the external tank. One such method involves using millimeter waves which have been shown to easily penetrate through the foam and provide high resolution images of its interior structures. This paper presents the results of inspecting three different SOFI covered panels by reflectometers at millimeter wave frequencies, specifically at 100 GHz. Each panel was fitted with various embedded anomalies/inserts representing voids and unbonds of diferent shapes, sizes and locations within each panel. In conjunction with these reJqectome&rs, radiators including a focused lens antenna and a small horn antenna were used. The focused lens antenna provided for a footprint diameter of approximately 1.25 cm (0.5") at 25.4 cm (10") away from the lens surface. The horn antenna was primarily operated in its near-field for obtaining relatively high resolution images. These images were produced using 2 0 scanning mechanisms. Discussions of the difference between the capabilities of these two types of antennas (radiators) for the purpose of inspecting the SOFI as it relates to the produced images are also presented.

Kharkovsky, S.↗

Millimeter Wave Detection of Localized Anomalies in the Space Shuttle External Fuel Tank Insulating Foam

The Space Shuttle Columbia's catastrophic accident emphasizes the growing need for developing and applying effective, robust and life-cycle oriented nondestructive testing (NDT) methods for inspecting the shuttle external fuel tank spray on foam insulation (SOFI). Millimeter wave NDT techniques were one of the methods chosen for evaluating their potential for inspecting these structures. Several panels with embedded anomalies (mainly voids) were produced and tested for this purpose. Near-field and far-field millimeter wave NDT methods were used for producing images of the anomalies in these panels. This paper presents the results of an investigation for the purpose of detecting localized anomalies in several SOFI panels. To this end, reflectometers at a relatively wide range of frequencies (Ka-band (26.5 - 40 GHz) to W-band (75 - 110 GHz)) and utilizing different types of radiators were employed. The resulting raw images revealed a significant amount of information about the interior of these panels. However, using simple image processing techniques the results were improved in particular as it relate s to detecting the smaller anomalies. This paper presents the results of this investigation and a discussion of these results.

Kharkovsky, S.↗

High Resolution Millimeter Wave Inspecting of the Orbiter Acreage Heat Tiles of the Space Shuttle

Presence of defects such as disbonds, delaminations, impact damage, in thermal protection systems can significantly reduce safety of the Space Shuttle and its crew. The physical cause of Space Shuttle Columbia's catastrophic failure was a breach in its thermal protection system, caused by a piece of external tank insulating foam separating from the external tank and striking the leading edge of the left wing of the orbiter. There is an urgent need for a rapid, robust and life-circle oriented nondestructive testing (NDT) technique capable of inspecting the external tank insulating foam as well as the orbiter's protective (acreage) heat tiles and its fuselage prior and subsequent to a launch. Such a comprehensive inspection technique enables NASA to perform life-cycle inspection on critical components of the orbiter and its supporting hardware. Consequently, NASA Marshall Space Flight Center initiated an investigation into several potentially viable NDT techniques for this purpose. Microwave and millimeter wave NDT methods have shown great potential to achieve these goals. These methods have been successfully used to produce images of the interior of various complex, thick and thin external tank insulating foam structures for real focused reflectometer at operating frequency from 50-100 GHz and for synthetic aperture techniques at Ku-band (12-18 GHz) and K-band (18-26 GHz). Preliminary results of inspecting heat tile specimens show that increasing resolution of the measurement system is an important issue. This paper presents recent results of an investigation for the purpose of detecting anomalies such as debonds and corrosion in metal substrate in complex multi-sectioned protective heat tile specimens using a real focused 150 GHz (D-band) reflectometer and wide-band millimeter wave holography at 33-50, GHz (Q-band).

Case, J. T.↗

Development of Natural Flaw Samples for Evaluating Nondestructive Testing Methods for Foam Thermal Protection Systems

Low density polyurethane foam has been an important insulation material for space launch vehicles for several decades. The potential for damage from foam breaking away from the NASA External Tank was not realized until the foam impacts on the Columbia Orbiter vehicle caused damage to its Leading Edge thermal protection systems (TPS). Development of improved inspection techniques on the foam TPS is necessary to prevent similar occurrences in the future. Foamed panels with drilled holes for volumetric flaws and Teflon inserts to simulate debonded conditions have been used to evaluate and calibrate nondestructive testing (NDT) methods. Unfortunately the symmetric edges and dissimilar materials used in the preparation of these simulated flaws provide an artificially large signal while very little signal is generated from the actual defects themselves. In other words, the same signal are not generated from the artificial defects in the foam test panels as produced when inspecting natural defect in the ET foam TPS. A project to create more realistic voids similar to what actually occurs during manufacturing operations was began in order to improve detection of critical voids during inspections. This presentation describes approaches taken to create more natural voids in foam TPS in order to provide a more realistic evaluation of what the NDT methods can detect. These flaw creation techniques were developed with both sprayed foam and poured foam used for insulation on the External Tank. Test panels with simulated defects have been used to evaluate NDT methods for the inspection of the External Tank. A comparison of images between natural flaws and machined flaws generated from backscatter x-ray radiography, x-ray laminography, terahertz imaging and millimeter wave imaging show significant differences in identifying defect regions.

Workman, Gary L.↗

A Novel 24 Ghz One-Shot Rapid and Portable Microwave Imaging System (Camera)

A novel 2D microwave imaging system at 24 GHz based on MST techniques. Enhanced sensitivity and SNR by utilizing PIN diode-loaded resonant slots. Specific slot and array design to increase transmission and reduce cross -coupling. Real-time imaging at a rate in excess of 30 images per second. Reflection as well transmission mode capabilities. Utility and application for electric field distribution mapping related to: Nondestructive Testing (NDT), imaging applications (SAR, Holography), and antenna pattern measurements.

Ghasr, M.T.↗