Search NASA⌕ Search

SEARCH · Search NASA

Results for “noninvasive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ghost-imaging-enhanced noninvasive spectral characterization of stochastic x-ray free-electron-laser pulses

Abstract High-intensity ultrashort X-ray free-electron laser (XFEL) pulses are revolutionizing the study of fundamental nonlinear x-ray matter interactions and coupled electronic and nuclear dynamics. To fully exploit the potential of this powerful tool for advanced x-ray spectroscopies, a noninvasive spectral characterization of incident stochastic XFEL pulses with high resolution is a key requirement. Here we present a methodology that combines high-acceptance angle-resolved photoelectron time-of-flight spectroscopy and ghost imaging to enhance the quality of spectral characterization of x-ray free-electron laser pulses. Implementation of this noninvasive high-resolution x-ray diagnostic can greatly benefit the ultrafast x-ray spectroscopy community by functioning as a transparent beamsplitter for applications such as transient absorption spectroscopy in averaging mode as well as covariance-based x-ray nonlinear spectroscopies in single-shot mode where the shot-to-shot fluctuations inherent to a self-amplified spontaneous emission (SASE) XFEL pulse are a powerful asset.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inverse Method for Noninvasive Material Discrimination with Multienergy X-Ray Radiography

Active x-ray inspections have great potential for noninvasive detection of illicit materials. Dual-energy x-ray radiography, in particular, has been used to determine material composition by utilizing the energy-dependence of the x-ray attenuation coefficients. However, current implementations of this method are limited in their ability to determine the material composition of composite objects. Here, in this paper, we present an inverse algorithm that uses multienergy x-ray radiography data to noninvasively reconstruct the contents of a container. A critical feature of the current contribution is that material identification can be performed using conventional detectors and x-ray spectra with different endpoint energies produced by varying nothing more than the tube voltage. Adaptive regularization is used to increase the accuracy of material estimations from multienergy data sets. The utility of these methods is demonstrated with experimentally acquired radiographs obtained using a tunable x-ray source that produces spectra with endpoint energies of 100–450 keV. The object inspected is a scale model of a nuclear materials storage container composed of three-dimensional printed plastic and stainless-steel spheres inside a thin-walled steel container. Reconstructions of the steel sphere thicknesses are within a root-mean-square error of 0.37 cm.

47 OTHER INSTRUMENTATION↗

Thresholding Analysis and Feature Extraction from 3D Ground Penetrating Radar Data for Noninvasive Assessment of Peanut Yield

This study explores the efficacy of utilizing a novel ground penetrating radar (GPR) acquisition platform and data analysis methods to quantify peanut yield for breeding selection, agronomic research, and producer management and harvest applications. Sixty plots comprising different peanut market types were scanned with a multichannel, air-launched GPR antenna. Image thresholding analysis was performed on 3D GPR data from four of the channels to extract features that were correlated to peanut yield with the objective of developing a noninvasive high-throughput peanut phenotyping and yield-monitoring methodology. Plot-level GPR data were summarized using mean, standard deviation, sum, and the number of nonzero values (counts) below or above different percentile threshold values. Best results were obtained for data below the percentile threshold for mean, standard deviation and sum. Data both below and above the percentile threshold generated good correlations for count. Correlating individual GPR features to yield generated correlations of up to 39% explained variability, while combining GPR features in multiple linear regression models generated up to 51% explained variability. The correlations increased when regression models were developed separately for each peanut type. This research demonstrates that a systematic search of thresholding range, analysis window size, and data summary statistics is necessary for successful application of this type of analysis. The results also establish that thresholding analysis of GPR data is an appropriate methodology for noninvasive assessment of peanut yield, which could be further developed for high-throughput phenotyping and yield-monitoring, adding a new sensor and new capabilities to the growing set of digital agriculture technologies.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Motion Compensation Methods for Noninvasive Cardiac Radioablation of Ventricular Tachycardia

Noninvasive cardiac radioablation is increasingly used for treatment of refractory ventricular tachycardia. Attempts to limit normal tissue exposure are important, including managing motion of the target. An interplay between cardiac and respiratory motion exists for cardiac radioablation, which has not been studied in depth. The objectives of this study were to estimate target motion during abdominal compression free breathing (ACFB) and respiratory gated (RG) deliveries and to investigate the quality of either implanted cardioverter defibrillator lead tip or the diaphragm as a gating surrogate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Online and noninvasive monitoring of battery health at negative-half cell in all-vanadium redox flow batteries using ultrasound

Hydrogen evolution is one of the major side reactions that is detrimental to the health of all-vanadium redox flow batteries, especially for long-term cycling. Effective, low-cost, and accurate online prediction and detection methods for hydrogen generation are not yet available. In this work, we designed an online, noninvasive ultrasonic probing approach for monitoring the state of charge (SoC), predicting the hydrogen generation, and detecting hydrogen gas bubbles in anolyte solutions. The technique employs a pulse-echo method to measure the sound speed and the acoustic attenuation coefficient of the anolyte solution. Through static offline experiments and online in operando experiments, we have demonstrated that when hydrogen gas is generated in anolyte solutions, large variations are observed in both sound speed and acoustic attenuation coefficient measurements. We found that the variations of acoustic attenuation coefficient are highly correlated (correlation coefficients >0.9) with the gas flow rate. In conclusion, the designed acoustic method can monitor the SoC of anolyte, predict the hydrogen generation, and detect the presence of gas bubbles in an anolyte solution and, thus, provide information about the state of health for operation and management of flow battery systems.

25 ENERGY STORAGE↗

Noninvasive acoustic time-of-flight measurements in heated, hermetically-sealed high explosives using a convolutional neural network

In this work, we present a data-driven technique for measuring the time-of-flight through material sealed within a container. Time-of-flight measurement provides a noninvasive means of quantifying the sound speed profile within a material by transmitting an acoustic burst and then measuring the time required for the burst to arrive at an opposing receiver. In a hermetically-sealed cylindrical container, a portion of the acoustic energy propagates through the material as a bulk wave, while the remainder of the acoustic energy propagates around the container walls as guided waves. As a result, interference from the guided waves obscures the bulk arrival, inhibiting measurement of the sound speed. The technique uses a Convolutional Neural Network (CNN) to identify critical features in the measured waveforms and identify bulk wave arrivals. We demonstrate this time-of-flight measurement technique on high explosive-filled containers as they are heated from room temperature to detonation. This is a particularly challenging application for acoustic time-of-flight measurements as the high explosives have significant sound speed gradients as they undergo heating, and they lead to significant attenuation of the bulk wave, as opposed to the guided waves, which do not suffer significant attenuation. We characterize the performance of the CNN as a function of the high explosive temperature and as a function of the CNN hyperparameters. We then provide physical insight into the error trends.

47 OTHER INSTRUMENTATION↗

Noninvasive interrogation of local flow phenomena in twisted tape swirled flow via positron emission particle tracking ($\mathrm{PEPT}$)

Twisted tape inserts are often used to enhance the performance of heat exchangers. Previous simulations suggest the existence of secondary vortices and modified axial velocity profiles in these swirled flows, with only limited experimental evidence for these predictions. Here in this work, positron emission particle tracking (PEPT) is used to interrogate turbulent twisted tape swirl flow in a pipe. PEPT is a noninvasive, radiotracer based flow measurement technique that does not require optical access, making it suitable for measurements in a number of engineering flow systems. The existence of the modified velocity profile and secondary flows is confirmed using PEPT, and flow is seen to still be developing 20 diameters downstream of the twisted channel entrance. Secondary vortices are further confirmed by the presence of increased vorticity in these regions, and turbulent fluctuations are seen to increase in magnitude near these flow structures. These results are in line with predictions and point to possible regions of reduced heat transfer and hot spots in twisted tape based heat exchangers. Suggestions are made for future experiments to investigate heated flows, utilizing the ability of PEPT to image flows in opaque systems for validating simulation of flows in engineering equipment, such as nuclear heat transport equipment.

42 ENGINEERING↗

Noninvasive liquid level sensing with laser generated ultrasonic waves

This article proposes a noninvasive liquid level sensing technique using laser-generated ultrasound waves for nuclear power plant applications. Liquid level sensors play an important role of managing the coolant system safely and stably in the plant structure. Current sensing techniques are mostly intrusive, performing inside the fluidic structure, which is disadvantageous in terms of the regular maintenance of the plant system. Furthermore, typical intrusive sensors do not perform stably under varying environmental conditions such as temperature and radiation. In this study, sensing units are attached to the outer surface of a liquid vessel to capture guided ultrasound waves in a nonintrusive manner. The signal intensity of the guided wave dissipates when the signal interacts with the internal liquid media. The sensing mechanism is mathematically expressed as an index value to correlate the liquid level with the sensor signal. For the acoustic wave generation, laser-generated ultrasound was adopted instead of using typical contact type transducers. Following the simulation validation of the proposed concept, the performance of the developed sensor was confirmed through experimental results under elevated liquid temperature conditions. Finally, the nonlinear multivariable regression exhibited the best-fit to the datasets measured under the variable liquid level and temperature conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noninvasive THz-TDS measurements of plasma bounded and optically shielded by Hall thruster wall material

We experimentally demonstrate the capability of terahertz time-domain spectroscopy (THz-TDS) to noninvasively measure the electron density and collision frequency of plasma bounded and optically shielded by Hall thruster wall material. This paper augments the standard THz-TDS plasma diagnostic theory to account for plasma boundaries, presents THz optical property measurements of three different wall materials (grades M, M26, and HP boron nitride composite), and provides electron density and collision frequency measurements of an inductively coupled plasma bounded and optically shielded by each wall material. We find that the electron density measurement capability is weakly impacted by the boundaries, whereas the electron collision frequency measurement capability is strongly reduced by the boundaries. Here, the bounded plasma electron density trends deviate substantially from those of the unbounded plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Noninvasive mid-circuit measurement and reset on atomic qubits

Mid-circuit measurement and reset of subsets of qubits are crucial ingredients of quantum error correction and many quantum information applications. Measurement of atomic qubits is accomplished through resonant fluorescence, which typically disturbs neighboring atoms due to photon scattering. We propose and prototype a scheme for measurement and reset that provides both spatial and spectral isolation by using tightly focused laser beams and narrow atomic transitions. The unique advantage of this scheme is that all operations are applied exclusively to the read-out qubit, with little overhead and negligible disturbance to the other qubits of the same species. In this paper, we pave the way for noninvasive and high-fidelity mid-circuit measurement and demonstrate all key building blocks on a single trapped barium ion.

atomic systems↗

Noninvasive Imaging of a Liquid Jet

Liquid jets are found in many applications, from printing to manufacturing to entertainment. Herein this study uses three different noninvasive imaging modalities to compare resulting images of a liquid jet operating at three Reynolds numbers that cover laminar, transitional, and turbulent flow. Selected measurement quantities from each image type are also compared. High-speed backlit (BL) imaging is a simple imaging technique found in many laboratories, and this is compared to two high-speed X-ray imaging techniques, white beam (WB) imaging and focused beam (FB) radiography. BL imaging can provide a wide field of view and is easy to implement, but it only shows the presence or absence of liquid. WB imaging can show detailed contours on the surface of the liquid jet, but the imaging region is much smaller. FB radiography produces a point-source measurement and can provide the quantitative, instantaneous local liquid path length, termed the equivalent path length (EPL). All three techniques provide similar measures of jet thickness, with the FB measurements having less variation. FB measurements can also provide detailed cross sections of the average liquid jet thickness at high spatial resolutions.

42 ENGINEERING↗

Noninvasive measurements of spin transport properties of an antiferromagnetic insulator

Antiferromagnetic insulators (AFIs) are of substantial interest because of their potential in the development of next-generation spintronic devices. One major effort in this emerging field is to harness AFIs for long-range spin information communication and storage. Here, we report a noninvasive method to optically access the intrinsic spin transport properties of an archetypical AFI α-Fe 2 O 3 via nitrogen-vacancy (NV) quantum spin sensors. By NV relaxometry measurements, we successfully detect the frequency-dependent dynamic fluctuations of the spin density of α-Fe 2 O 3 along the Néel order parameter, from which an intrinsic spin diffusion constant of α-Fe 2 O 3 is experimentally measured in the absence of external spin biases. Our results highlight the significant opportunity offered by NV centers in diagnosing the underlying spin transport properties in a broad range of high-frequency magnetic materials such as two-dimensional magnets, spin liquids, and magnetic Weyl semimetals, which are challenging to access by the conventional measurement techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Noninvasive acoustical property measurement of fluids

Methods for noninvasive determination of acoustical properties of flowing in pipes having a large ratio (>10) of pipe diameter to wall thickness, and in highly attenuating fluids are described. When vibrations are excited on the outer surface of the wall of a pipe, the resulting vibrations propagate directly through the wall in a normal direction and through the pipe wall as guided waves, appearing on the opposite side of the pipe. This dual path propagation through pipes, where guided waves take the circumferential path in the wall of the pipe and may interfere with the time of-flight measurement obtained from the direct path through the fluid, is at least in part resolved by subtracting the signal from the guided wave from the combined signal, thereby permitting improved observation of the direct path propagation through the fluid.

Sinha, Dipen N.↗

Unique Role of GeO 2 as a Noninvasive Promoter of Nano‐Sized Zeolite Crystals

Abstract The synthesis of zeolites with nano‐sized dimensions is often limited to a narrow design space that conventionally relies upon the design of organics to direct hierarchical materials. Here, it is demonstrated that the addition of an inorganic modifier, germanium oxide (GeO 2 ), to a zeolite growth mixture directs the formation of crystals with ultrasmall dimensions. This effect is observed for zeolites ZSM‐11 and ZSM‐5 over a range of synthesis conditions wherein the role of GeO 2 in zeolite crystallization deviates from its typical function as a heteroatom. Notably, the final products contain trace amounts of Ge, which indicates the inorganic modifier does not compete for sites in the zeolite framework based on its formation of a discrete phase that enables GeO 2 recovery. Catalytic tests using the methanol‐to‐hydrocarbons reaction reveal significant enhancement in the performance of zeolite catalysts prepared with GeO 2 compared to reported examples of nano‐sized zeolites. These findings highlight a potentially generalizable and commercially viable synthesis method to reduce mass‐transport limitations in zeolites for diverse applications.

Chemistry↗

Noninvasive Near‐Field Spectroscopy of Single Subwavelength Complementary Resonators

Abstract Subwavelength metallic resonators provide a route to achieving strong light–matter coupling by means of tight confinement of resonant electromagnetic fields. Investigation of such resonators however often presents experimental difficulties, particularly at terahertz (THz) frequencies. A single subwavelength resonator interacts weakly with THz beams, making it difficult to probe it using far‐field methods, whereas arrays of resonators exhibit inter‐resonator coupling, which affect the resonator spectral signature and field confinement. Here, traditional far‐field THz spectroscopy is systematically compared with aperture‐type THz near‐field microscopy for investigating complementary THz resonators. While the far‐field method proves impractical for measuring single resonators, the near‐field technique gives high signal‐to‐noise spectral information, only achievable in the far‐field with resonator arrays. At the same time, the near‐field technique allows to analyze single resonators without significant interaction with the near‐field probe. Furthermore, the near‐field technique allows highly confined fields and surface waves to be mapped in space and time. This information gives invaluable insight into spectral response in resonator arrays. This near‐field microscopy and spectroscopy method enables investigations of strong light–matter coupling at THz frequencies in the single‐resonator regime.

Hale, Lucy L.↗

Balanced Fast-SpaciMS capillary configurations provide practically noninvasive channel-average measurements in catalytic monoliths

Spatially resolved capillary-inlet mass spectrometry (SpaciMS) provides a detailed picture of the spatiotemporal evolution of reaction network in catalytic monoliths. In the present work, we combine the SpaciMS experiments with a newly developed non-isothermal 3D CFD model for heterogeneously catalyzed reactive flows, including diffusion and permeation through the coated catalyst and channel wall. We explore how the capillary size and sampling rate can be balanced to minimize the impact on probed-channel conversions and provide species concentration measurements representative of the free channel average. In all studied configurations, the balanced sampling-rate fraction is noticeably higher than the corresponding capillary occlusion fraction. For a typical 350-micron capillary that occupies 11% of the channel cross- section, the balanced sampling rate represents 43% of the channel flow. Furthermore, the present work shows that together, a balanced SpaciMS configuration and numerical simulation provide accurate channel-averaged information of a monolithic catalyst under realistic operation conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗