Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Coded-aperture imaging in nuclear medicine

Coded-aperture imaging is a technique for imaging sources that emit high-energy radiation. This type of imaging involves shadow casting and not reflection or refraction. High-energy sources exist in x ray and gamma-ray astronomy, nuclear reactor fuel-rod imaging, and nuclear medicine. Of these three areas nuclear medicine is perhaps the most challenging because of the limited amount of radiation available and because a three-dimensional source distribution is to be determined. In nuclear medicine a radioactive pharmaceutical is administered to a patient. The pharmaceutical is designed to be taken up by a particular organ of interest, and its distribution provides clinical information about the function of the organ, or the presence of lesions within the organ. This distribution is determined from spatial measurements of the radiation emitted by the radiopharmaceutical. The principles of imaging radiopharmaceutical distributions with coded apertures are reviewed. Included is a discussion of linear shift-variant projection operators and the associated inverse problem. A system developed at the University of Arizona in Tucson consisting of small modular gamma-ray cameras fitted with coded apertures is described.

Smith, Warren E.↗

A high speed imaging system for nuclear diagnostics

A high speed imaging system based on state-of-the-art photosensor arrays was designed for use in nuclear diagnostics. The system is comprised of a front end rapid scan solid state camera, a high speed digitizer, and a PCM line driver in a downhole package and a memory buffer system in an uphole trailer. The downhole camera takes a snapshot of a nuclear device created flux stream, digitizes the image and transmits it to the uphole memory system before being destroyed. The memory system performs two functions: it retains the data for local display and processing by a microprocessor, and it buffers the data for retransmission at slower rates to a computational facility. In the talk, the impetus for such a system as well as its operation was discussed, along with systems under development which incorporate higher data rates and more resolution.

Eyer, H. H.↗

Near-infrared images of the nuclear region of NGC 5128

High-resolution near-infrared images of NGC 5128 (Centaurus A) are presented, which probe the optically obscured nuclear region. The images show a central source at K (2.23 microns) and 3.26 microns. This central object is not prominent in the shorter wavelength images at J and H (1.23 and 1.65 micron, respectively), probably due to high extinction. The color images (H - K and J - H) provide evidence for a steep gradient in extinction across the array field. The images indicate three components: a red, variable, compact nucleus; the diffuse elliptical galaxy starlight; and a blue extension to the NE. The nucleus has decreased in flux density by a factor of 2.5 over less than about 5 yr at 3.26 microns. However, current spectral constraints on the nuclear source at near-infrared wavelengths cannot definitively determine the relative contributions from the known ratio synchrotron source (AGN) and from various possible dust-enshrouded thermal sources. The blue spot, approximately 7.6 +/- 0.1 arcsec NE of the nucleus appears to be a hole in the extinction, possibly enhanced by scattered light from the active galactic nucleus.

Turner, Paula C.↗

A potential nuclear magnetic resonance imaging approach for noncontact temperature measurement

It is proposed that in a nuclear magnetic resonance (NMR) imaging experiment that it should be possible to measure temperature through an extended volume. The basis for such a measurement would depend upon sensing a temperature dependent on NMR parameter in an inert, volatile molecule (or fluid) filling the volume of interest. Exploratory work suggest that one suitable candidate for such a purpose might be CH3Cl. Possible parameters, other inert gases and feasible measurement schemes that might provide such temperature measurement are discussed.

Manatt, Stanley L.↗

High resolution 1-20 micron imaging of the nuclear environment of NGC 1068

We present new mid-infrared continuum and near-IR line images of the nuclear environment of the nearby (14 Mpc) Seyfert 2 galaxy NGC 1068. The 8, 10, and 19 micron data were measured with our new mid-IR array camera, MIRACLE, at UKIRT in Nov. 1991 while our images of the H2 2.121 micron and (Fe 2) 1.64 micron lines were obtained with FAST, the MPE imaging spectrometer, at the 4.2m William Herschel Telescope in Aug. 1991. The MIRACLE data were imaged through narrow band (lambda/delta(lambda) greater than or equal to 50) filters whereas FAST incorporates a Fabry-Perot etalon (lambda/delta(lambda) greater than or equal to 950).

Cameron, M.↗

Changes in left ventricular function as determined by the multi-wire gamma camera at near presyncopal levels of lower body negative pressure

At presyncopal levels of lower body negative pressure (LBNP), we have frequently observed electrocardiographic responses that may be due to changes in cardiac position and/or shape, but could be indicative of altered myocardial function. To further investigate this, we evaluated cardiac function using a nuclear imaging technique in 21 healthy subjects (17 men and 4 women) after 30 minutes of supine rest and near the end of a presyncopal-limited LBNP exposure (LBNP averaged 65 plus or minus 3 mmHg at injection). Cardiac first pass images were obtained with a Multi-Wire Gamma Camera following an intravenous bolus injection of 30-50 millicurries of Tantalum-178. Manual blood pressures and electrocardiograms were obtained throughout the 3 minute graded LBNP protocol. Between rest and injection during LBNP, heart rate increased (P less than 0.01) from 67 plus or minus 3 beats per minute to 99 plus or minus beats per minute, systolic blood pressure decreased (P less than 0.01) from 110 plus or minus 3 mmHg to 107 plus or minus 3 mmHg and left ventricular ejection fraction (EF) decreased (P less than 0.01) from 0.57 plus or minus 0.02 to 0.48 plus or minus 0.02. During LBNP, ST segment depression of at least 0.5 mm occurred in 7 subjects. Subjects with ST depression had greater reductions (P = 0.05) in EF than subjects without ST depression (0.15 plus or minus 0.07 versus 0.005 plus or minus 0.03), but also tolerated greater levels (P less than 0.05) of negative pressure (88 plus or minus mmHg versus 69 plus or minus 5 mmHg). There was a significant relationship between presyncopal LBNP level and EF (R(exp 2) = 0.50, P less than 0.05). Our findings suggest there may be a decrease in systolic myocardial function at high levels of LBNP.

Pintner, R.↗

In vivo nuclear magnetic resonance imaging

A number of physiological changes have been demonstrated in bone, muscle and blood after exposure of humans and animals to microgravity. Determining mechanisms and the development of effective countermeasures for long duration space missions is an important NASA goal. The advent of tomographic nuclear magnetic resonance imaging (NMR or MRI) gives NASA a way to greatly extend early studies of this phenomena in ways not previously possible; NMR is also noninvasive and safe. NMR provides both superb anatomical images for volume assessments of individual organs and quantification of chemical/physical changes induced in the examined tissues. The feasibility of NMR as a tool for human physiological research as it is affected by microgravity is demonstrated. The animal studies employed the rear limb suspended rat as a model of mucle atrophy that results from microgravity. And bedrest of normal male subjects was used to simulate the effects of microgravity on bone and muscle.

Leblanc, A.↗

High resolution image measurements of nuclear tracks

The striking clarity and high contrast of the mouths of tracks etched in CR-39 plastic detectors allow automatic measurement of track parameters to be made with simple image-recognition equipment. Using a commercially available Vidicon camera system with a microprocessor-controlled digitizer, resolution for normally incident C-12 and N-14 ions at 32 MeV/amu equivalent to a 14sigma separation of adjacent charges was demonstrated.

Shirk, E. K.↗

Ellipticals with kinematically distinct cores : HST imaging of the nuclear structure of IC 1459

The elliptical galaxy IC 1459 has one of the strongest counter-rotating core components of any observed elliptical. Here we present Hubble Space Telescope (HST) Planetary Camera images of the center of IC 1459. Before deconvolution, our V band images reveal a bright point source at the galaxy nucleus, and dust near the nucleus. After removal of the central point source, deconvolution and model fitting, we show that the central starlight profile is better fit by a 'cusp' model than an isothermal core model. The photometric properties of the stellar light are comparable to those of other ellipticals without counter-rotating core components. There is an indication of a central stellar disk, although its detection is complicated by the extensive dust. Although the velocity field of the emission-line gas is ordered, the dust distribution is very irregular, and indicates nonequilibrium motions. The irregular dust distribution suggests that material is currently infalling and may be fueling the active nucleus. There is no direct evidence which relates the dust and gas to the peculiar stellar kinematics.

Forbes, Duncan A.↗

In vivo nuclear magnetic resonance imaging

During the past year the Woodlands Baylor Magnetic Resonance Imaging (MRI) facility became fully operational. A detailed description of this facility is given. One significant instrument addition this year was the 100 MHz, 40cm bore superconducting imaging spectrometer. This instrument gives researchers the capability to acquire high energy phosphate spectra. This will be used to investigate ATP, phosphocreatinine and inorganic phosphate changes in normal and atrophied muscle before, during and after exercise. An exercise device for use within the bore of the imaging magnet is under design/construction. The results of a study of T sub 1 and T sub 2 changes in atrophied muscle in animals and human subjects are given. The imaging and analysis of the lower leg of 15 research subjects before and after 5 weeks of complete bedrest was completed. A compilation of these results are attached.

Leblanc, A.↗

1986 Nuclear Science Symposium, 33rd, and 1986 Symposium on Nuclear Power Systems, 18th, Washington, DC, Oct. 29-31, 1986, Proceedings

Papers are presented on space, low-energy physics, and general nuclear science instrumentations. Topics discussed include data acquisition systems and circuits, nuclear medicine imaging and tomography, and nuclear radiation detectors. Consideration is given to high-energy physics instrumentation, reactor systems and safeguards, health physics instrumentation, and nuclear power systems.

Stubblefield, F. W.↗

High Resolution Three-Color Imaging of Spirals With Nuclear Star-Forming Rings

Nuclear rings in barred spirals offer an opportunity to study starburst properties in order to develop an understanding of the evolution of star formation in galaxies. To achieve this understanding, a large scale imaging survey in the H alpha line and in the B and I broad bands has been performed. Analysis of all galaxies that reveal nuclear rings in the H alpha line will be compared to numerical models so that the relative ages between the starforming clumps can be estimated. The luminosity function of the starforming regions will be related to the measured properties of the associated star-cluster and the required ionizing flux. Also B - I color index images will be performed to indicate the location of the dust lanes.

Mazzuca, Lisa↗

Imaging spectrophotometry of the nuclear outflow of NGC 1068

This observational program (in conjunction with R. B. Tully (IfA, Honolulu), and J. Bland (Rice U., Houston)) aims to constrain the kinematic organization and dominant excitation mechanisms of ionized gas in active galaxies. More generally, researchers are interested in the dynamics of radiative, supersonic flows in the Interstellar Medium (ISM). Imaging Fabry-Perot interferometers and low-noise Charge Coupled Devices (CCDs) are used for complete spatial coverage of the complex gas distribution in circumnuclear narrow-line regions (NLRs). Extranuclear emission line widths in NLRs can exceed 3000 km s(-1), so to avoid inter-order confusion researchers use an etalon of 4000 km s(-1) free spectral range to map (N II) lambda lambda 6548, 6583 and H alpha. To maximize spatial resolution, researchers select nearby active systems independent of luminosity but known to possess interesting morphologies and/or high-velocity extranuclear ionized gas. Monochromatic images Full Width Half Maximum (FWHM) approx. 65 km s(-1) have thus far been obtained in 1 second or better seeing at the U. Hawaii 2.2m, CFH 3.6m, and CTIO 4.0m telescopes. These are stacked into grids of line profiles, of spectrophotometric quality, at sub-arcsecond increments across a 3 second field. To handle the approx. 20,000 to 300,000 useful spectra that arise from a typical night's work, researchers have developed a complete analysis and reduction package for VAX and Sun image workstations. Reduction involves parametrization of approx. 10 to the 8th raw data points to a few maps (e.g., velocities of each kinematic subsystem, continuum-free line fluxes) containing approx. 10 to the 5th pixels. Researchers identify kinematic and structural symmetries by examining these maps and the point to point variations of the synthesized line profiles. The combination of monochromatic images and full spatial sampling of line profiles has allowed them to isolate such symmetries and has led to reliable kinematic deprojections.

Cecil, Gerald↗

MRI of the lung gas-space at very low-field using hyperpolarized noble gases

In hyperpolarized (HP) noble-gas magnetic resonance imaging, large nuclear spin polarizations, about 100,000 times that ordinarily obtainable at thermal equilibrium, are created in 3He and 129Xe. The enhanced signal that results can be employed in high-resolution MRI studies of void spaces such as in the lungs. In HP gas MRI the signal-to-noise ratio (SNR) depends only weakly on the static magnetic field (B(0)), making very low-field (VLF) MRI possible; indeed, it is possible to contemplate portable MRI using light-weight solenoids or permanent magnets. This article reports the first in vivo VLF MR images of the lungs in humans and in rats, obtained at a field of only 15 millitesla (150 Gauss).

NASA Discipline Life Sciences Technologies↗

Star and cluster formation in NGC 1275

Luminous, blue, and unresolved objects have been found by imaging the nuclear region of the central galaxy in the Perseus Cluster, NGC 1275. Stellar formation in a cooling flow in which gas clouds confined by weak magnetic fields are allowed to remain at low densities is favored. Cloud-cloud collisions and coagulation in the high cloud density environment at the center of the galaxy then causes some clouds to become gravitationally unstable and to form globular clusters.

Richer, Harvey B.↗

ROSAT PSPC and HRI observations of the composite starburst/Seyfert 2 galaxy NGC 1672

The nearby barred spiral galaxy NGC 1672 has been observed with the Position Sensitive Proportional Counter (PSPC) and High Resolution Imager (HRI) instruments on board the ROSAT X-ray satellite. NGC 1672 is thought to have an obscured Seyfert nucleus, and it has strong starburst activity as well. Three bright X-ray sources with luminosities 1-2 x 10(exp 40) erg/s are clearly identified with NGC 1672. The strongest lies at the nucleus, and the other two lie at the ends of NGC 1672's prominent bar, locations that are also bright in H alpha and near-infrared images. The nuclear source is resolved by the HRI on about the scale of the recently identified nuclear ring, and one of the sources at the ends of the bar is also probably resolved. The X-ray spectrum of the nuclear source is quite soft, having a Raymond-Smith plasma temperature of approximately equals 0.7 keV and little evidence for intrinsic absorption. The ROSAT band X-ray flux of the nuclear source appears to be dominated not by X-ray binary emission but rather by diffuse gas emission. The absorption and emission properties of the sources, as well as their spatial extents, lead us to models of superbubbles driven by supernovae. However, the large density and emission measure of the nuclear X-ray source stretch the limits that can be comfortably accommodated by these models. We do not detect direct emission from the putative Seyfert nucleus, although an alternative model for the nuclear source is thermal emission from gas that is photoionized by a hidden Seyfert nucleus. The spectra of the other two X-ray sources are harder than that of the nuclear source, and have similar difficulties with regard to superbubble models.

Brandt, W. N.↗

High speed multiwire photon camera

An improved multiwire proportional counter camera having particular utility in the field of clinical nuclear medicine imaging. The detector utilizes direct coupled, low impedance, high speed delay lines, the segments of which are capacitor-inductor networks. A pile-up rejection test is provided to reject confused events otherwise caused by multiple ionization events occuring during the readout window.

Lacy, Jeffrey L.↗

High speed multiwire photon camera

An improved multiwire proportional counter camera having particular utility in the field of clinical nuclear medicine imaging. The detector utilizes direct coupled, low impedance, high speed delay lines, the segments of which are capacitor-inductor networks. A pile-up rejection test is provided to reject confused events otherwise caused by multiple ionization events occurring during the readout window.

Lacy, Jeffrey L.↗