Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclide identification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Algorithm improvement program nuclide identification algorithm scoring criteria and scoring application.

The goal of the Domestic Nuclear Detection Office (DNDO) Algorithm Improvement Program (AIP) is to facilitate gamma-radiation detector nuclide identification algorithm development, improvement, and validation. Accordingly, scoring criteria have been developed to objectively assess the performance of nuclide identification algorithms. In addition, a Microsoft Excel spreadsheet application for automated nuclide identification scoring has been developed. This report provides an overview of the equations, nuclide weighting factors, nuclide equivalencies, and configuration weighting factors used by the application for scoring nuclide identification algorithm performance. Furthermore, this report presents a general overview of the nuclide identification algorithm scoring application including illustrative examples.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Algorithm Improvement Program Nuclide Identification Algorithm Scoring Criteria And Scoring Application - DNDO.

The goal of the Domestic Nuclear Detection Office (DNDO) Algorithm Improvement Program (AIP) is to facilitate gamma-radiation detector nuclide identification algorithm development, improvement, and validation. Accordingly, scoring criteria have been developed to objectively assess the performance of nuclide identification algorithms. In addition, a Microsoft Excel spreadsheet application for automated nuclide identification scoring has been developed. This report provides an overview of the equations, nuclide weighting factors, nuclide equivalencies, and configuration weighting factors used by the application for scoring nuclide identification algorithm performance. Furthermore, this report presents a general overview of the nuclide identification algorithm scoring application including illustrative examples.

97 MATHEMATICS AND COMPUTING↗

Shielding and activity estimator for template-based nuclide identification methods

According to one embodiment, a method for estimating an activity of one or more radio-nuclides includes receiving one or more templates, the one or more templates corresponding to one or more radio-nuclides which contribute to a probable solution, receiving one or more weighting factors, each weighting factor representing a contribution of one radio-nuclide to the probable solution, computing an effective areal density for each of the one more radio-nuclides, computing an effective atomic number (Z) for each of the one more radio-nuclides, computing an effective metric for each of the one or more radio-nuclides, and computing an estimated activity for each of the one or more radio-nuclides. In other embodiments, computer program products, systems, and other methods are presented for estimating an activity of one or more radio-nuclides.

97 MATHEMATICS AND COMPUTING↗

Small plasma focus as neutron pulsed source for nuclides identification

In this paper, we present preliminary results on the feasibility of employing a low energy (2 kJ, 31 kV) plasma focus device as a portable source of pulsed neutron beams (2.45 MeV) generated by nuclear fusion reactions D-D, for the “in situ” analysis of substances by nuclear activation. This source has the relevant advantage of being pulsed at requirement, transportable, not permanently radioactive, without radioactive waste, cheap, among others. We prove the feasibility of using this source showing several spectra of the characteristic emission line for manganese, gold, lead, and silver.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Benchmarking Algorithm for Radio Nuclide Identification (BARNI) Literature Review

This is a literature review of published radioisotope identification (ID) methods, and an attempt at systematic organization of the approaches for solving this problem. In addition, there is an overview of the related open and closed source software, and patents related to radioisotope identification. This document is also part of the development plan for BARNI (Benchmarking Algorithm for RadioNuclide Identification) software, since it is meant to be a comparison tool, a summary of radiation ID performance evaluations is also included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Novel HPGe Probe solution for Harsh Environments

In situ measurement is a privileged way of monitoring radioactive contamination compared to analyzing samples in a distant, specialized laboratory. Scintillators based spectrometers offer small footprints and are easy to easy to use, however they do not provide an accurate nuclide identification capability and activities measurement because notably of their limited energy resolution, for instance when low minimum detectable activity (MDA) are required, or in complex mixture of sources. On the other hand, High Purity Germanium (HPGe) detectors provide unmatched nuclide identification capability with the lowest MDA but they are not always of practical use on the field because the crystal needs to be cooled down to liquid nitrogen temperature, increasing the overall weight, bulkiness and complexity of the measurement. This paper presents the configuration and performance of a novel turnkey and compact HPGe solution developed by Canberra for radionuclide identification under harsh environments. Radio-contaminations surveys now can be undertaken outdoor under various weather conditions, in contaminated areas, underground or underwater locations (including under sea water), with fast on site deployment. The spectrometer is also designed in a small diameter tubular shape to offer minimal footprint for an operation in narrow and confined spaces. Besides, this innovative design does not mitigate the performances nor the reliability experienced with standard laboratory-grade HPGe spectrometers. This achievement relies on advanced technologies such as the encapsulation of the crystal in ultra-high vacuum (UHV) which provides higher robustness and does not requires thermal cycles faced with regular HPGe equipment. It also relies on a low vibration, low consumption electrical cooler so that no liquid nitrogen is being used. The detector is connected to a state-of-the-art digital spectroscopy suite embedded in an autonomous acquisition station monitoring the cryo-cooler and including the spectroscopy software. This system presented is therefore a new solution to perform high resolution spectroscopy where no current products are compact or robust enough to be installed, for instance for soil and water decontamination measurement when anthropogenic radioactive sources must be identified from natural ones or when low contamination levels are expected, the MDA being 3 to 5 times higher than scintillator-based detectors of similar sizes. Environmental inspection such as well logging for geophysics and mining, water contamination monitoring, or decommissioning works can thus benefits from both ruggedness, mobility without compromise on the nuclide identification or activity measurement capability. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radio-nuclide mixture identification using medium energy resolution detectors

According to one embodiment, a method for identifying radio-nuclides includes receiving spectral data, extracting a feature set from the spectral data comparable to a plurality of templates in a template library, and using a branch and bound method to determine a probable template match based on the feature set and templates in the template library. In another embodiment, a device for identifying unknown radio-nuclides includes a processor, a multi-channel analyzer, and a memory operatively coupled to the processor, the memory having computer readable code stored thereon. The computer readable code is configured, when executed by the processor, to receive spectral data, to extract a feature set from the spectral data comparable to a plurality of templates in a template library, and to use a branch and bound method to determine a probable template match based on the feature set and templates in the template library.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopy identification performance enhancement of a novel CZT/CsI hybrid system

New hybrid spectroscopic systems directly combine spectra from detectors with very different energy resolutions, accommodating standard analyses of the output hybrid spectrum. Simulations of a hybrid system consisting of a 2 or 4 cm{sup 3} cadmium zinc telluride detector combined with a 32.8 cm{sup 3} CsI(Tl) were evaluated for identification performance. 29 nuclides of interest for security applications were simulated as singles and unique pairs, producing 435 spectral simulations at live times of 3, 10, 30, 100 and 300 seconds. The nuclides were modeled as point sources at 25 cm with activities that provide an interesting range of statistical significance for the range of counting times. Standard nuclide identification analyses were applied to the component detectors as well as the hybrid combination. Tallies of the results were used to calculate true and false identification rates. The hybrid system was shown to provide an identification performance benefit, consistently achieving performances closest to ideal relative to the separate component detectors. The hybrid approach enables the consideration of a greater variety of measurement system solutions in terms of cost and performance. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Introduction to InterSpec for Gamma-Ray Analysis [Slides]

InterSpec is a spectrum viewing and analysis tool that can be used for nuclide identification and quantification. Developed at Sandia National Laboratories, it is open source and can be obtained at: https://github.com/sandialabs/interspec/releases. These slides do not cover nuclide quantification and only touch on nuclide identification (ID).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance Evaluation of an Intelligent Sensor Platform for Radiation Monitoring Applications

Accurate, rugged, and reliable radiation detection systems are important for area and environmental monitoring applications. The desire for spectroscopic capability has increased in monitoring aspects of the nuclear fuel cycle to provide fast characterization of the radiation profile of a situation, such as the planned or unplanned release of material. The reduction or elimination of having to conduct sampling for laboratory analysis can result in significant cost savings for an industry, government agency, or regulatory body. A new system, comprised of a NaI:Tl scintillator and a G-M tube, has been designed and tested, taking into account the following end-user requirements: ease-of-use, capability to network and supervise multiple units, compact form factor, low power consumption, versatility, and stability. The detector sizes were selected to accommodate a dose rate up to 1 Sv/hr. Several algorithms and analysis routines have been developed to incorporate these key needs without sacrificing on accuracy, dynamic range, nuclide identification, and sensitivity. This presentation will introduce the major hardware and software components of the platform, as well as the user interface and data analysis workflow. Key features of the hardware include an environmentally robust housing, low power signal processing electronics, patented LED-based gain stabilization, and an embedded processor for unattended instrument management and data analysis. New and improved algorithms for determining scintillator gamma dose rates, total integrated dose, and nuclide identification will be introduced. The two detector elements were modeled with MCNP and validated experimentally. The results of the radiological testing shall be presented including energy resolution, throughput, dose response, and minimum detectable activities. The dose response has been evaluated in simulations and with measurements to ensure accurate response with respect to energy spectrum of the dose field and direction of the incident radiation. Spectroscopy evaluations, such as nuclide detection probability and false alarm rates, were performed and comparisons to existing algorithms shall also be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GeMini: The Next-Generation Mechanically-Cooled Germanium Spectrometer

The next-generation mechanically-cooled germanium spectrometer has been developed. GeMini (MINIature GErmanium spectrometer) has been designed to bring high-resolution gamma-ray spectroscopy to a range of demanding field environments. Intended applications include short-notice inspections, border patrol, port monitoring and emergency response, where positive nuclide identification of radioactive materials is required but power and liquid cryogen are not easily available. GeMini weighs 2.75 kg for the basic instrument and 4.5 kg for the full instrument including user interface and ruggedized hermetic packaging. It is very low power allowing it to operate for 10 hours on a single set of rechargeable batteries. This instrument employs technology adapted from the gamma-ray spectrometer currently flying on NASA's Mercury MESSENGER spacecraft. Specifically, infrared shielding techniques allow for a vast reduction of thermal load. This in turn allows for a smaller, lighter-weight design, well-suited for a hand-held instrument. Three working prototypes have been built and tested in the lab. The measured energy resolution is 3 keV fwhm at 662 keV gamma-rays. This paper will focus on the design and performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmark Algorithm for RadioNuclide Identification v1.0

Benchmark Algorithm for Radio-Nuclide Identification (BARNI) is an automatic radionuclide identification tool for use with gamma-ray spectra. BARNI is designed to serve as a comparative tool for commercial vendor algorithms, such as those found in RadioIsotope Identification Devices (RIID). The tool incorporates an automated training routine allowing BARNI's classifier to be trained for a variety of detectors. The identification algorithm uses a peak search, the results of which are used to build features that are subsequently used for training a classifier. The user provided spectral templates allow BARNI to be trained for any detector of the user's choice. Is

NELSON, KARLE.↗

Dense autoencoders, clustering techniques, and semi-supervised learning for HPGe $γ$-spectra

Classifying high-resolution gamma spectra by their isotopic content is an essential task in nuclear forensics and other applications. Traditional analysis methods are often time-intensive, but machine learning (ML) may help analysts quickly process many spectra. Such methods tend to rely on abundant, well-labeled data for training. Historical gamma data exists in various fields but is not uniformly useful for supervised ML due to inconsistent labeling. Here, to address some of these challenges, we present a method to classify and organize unlabeled data from high-purity germanium detectors using an autoencoding neural network (autoencoder). We trained dense autoencoders to compress gamma data into latent representations that enable efficient data characterization. By clustering the encoded spectra or lower-dimensional mappings of them, we identified and removed portions of over-abundant data categories, resulting in a more balanced dataset and improved autoencoder performance. This encoding and clustering pipeline also enabled the organization of spectra into self-consistent categories. Finally, we found that encoded representations showed potential as inputs for semi-supervised learning of nuclide identification (NID) labels, achieving an average F1 score of 0.85 ± 0.03 when mapping encodings to a set of 65 isotope labels.

Autoencoders↗

Software Requirements Document: Benchmarking Algorithm for RadioNuclide Identification (BARNI)

This document provides the requirements for the Benchmark Algorithm for Radio-Nuclide Identification (BARNI) software, an open-source tool for comparing radionuclide identification algorithm performance. It specifies the requirements for the user interface, maintainability, documentation and testing. In addition, this document outlines the core functionality of the product, which will align with the needs of the Office of Nuclear Smuggling Detection and Deterrence (NSDD). Specifically, these include interoperability with RASE, and compatibility with the FLIR R400.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗