Search NASA⌕ Search

SEARCH · Search NASA

Results for “numerical aperture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Numerical aperture limits on efficient ball lens coupling of laser diodes to single-mode fibers with defocus to balance spherical aberration

The potential capabilities and limitations of single ball lenses for coupling laser diode radiation to single-mode optical fibers have been analyzed; parameters important to optical communications were specifically considered. These parameters included coupling efficiency, effective numerical apertures, lens radius, lens refractive index, wavelength, magnification in imaging the laser diode on the fiber, and defocus to counterbalance spherical aberration of the lens. Limiting numerical apertures in object and image space were determined under the constraint that the lens perform to the Rayleigh criterion of 0.25-wavelength (Strehl ratio = 0.80). The spherical aberration-defocus balance to provide an optical path difference of 0.25 wavelength units was shown to define a constant coupling efficiency (i.e., 0.56). The relative numerical aperture capabilities of the ball lens were determined for a set of wavelengths and associated fiber-core diameters of particular interest for single-mode fiber-optic communication. The results support general continuing efforts in the optical fiber communications industry to improve coupling links within such systems with emphasis on manufacturing simplicity, system packaging flexibility, relaxation of assembly alignment tolerances, cost reduction of opto-electronic components and long term reliability and stability.

Wilson, R. Gale↗

Practical design considerations and performance characteristics of high numerical aperture holographic lenses

The diffraction efficiency of interferometrically formed holographic lenses is influenced by the recording geometry and properties of the recording material. Variations in efficiency increase when attempting to make high numerical aperture elements. The factors which influence the diffraction efficiency of high numerical aperture holographic lenses are examined.

Kostuk, Raymond K.↗

Effect of numerical aperture on signal level in cylindrical waveguide evanescent fluorosensors

The effect of numerical aperture on signal level from fluorescent substances or solutions in the evanescent zone of a cylindrical waveguide is analyzed. The analysis applies to the case in which the fluorescence is excited by the evanescent wave of a fiber and the fluorescence signal is that which tunnels back into the same fiber. The analysis is for two cases: bulk fluorescence and fluorescence of a thin film layer. Experimental results are also presented.

Glass, Thomas R.↗

The 3D modeling of high numerical aperture imaging in thin films

A modelling technique is described which is used to explore three dimensional (3D) image irradiance distributions formed by high numerical aperture (NA is greater than 0.5) lenses in homogeneous, linear films. This work uses a 3D modelling approach that is based on a plane-wave decomposition in the exit pupil. Each plane wave component is weighted by factors due to polarization, aberration, and input amplitude and phase terms. This is combined with a modified thin-film matrix technique to derive the total field amplitude at each point in a film by a coherent vector sum over all plane waves. Then the total irradiance is calculated. The model is used to show how asymmetries present in the polarized image change with the influence of a thin film through varying degrees of focus.

Flagello, D. G.↗

Collection of Light From an Optical Fiber With a Numerical Aperture Greater Than One

In an optical fiber having NA greater than 1, light may be internally reflected when it strikes the fiber end at a fiber-air interface. This problem may be overcome by modification of the fiber by reverse tapering the core. Light is redirected by the taper to strike the interface at an angle closer to normal. This allows light to exit the fiber end that would by internally reflected in an untapered fiber of NA greater than 1. The novelty of the present invention lies in the tapering of the fiber core for increased through transmission of light. Prior art devices have made use of fiber tapers to achieve mode control or fiber coupling. The problem of internal reflection has not been addressed as it is one that is not as important in fibers having NA less than 1, which are more common. In chemical sensing it is advantageous to make use of fibers having higher NA due to an increased sensitivity. However the advantages in sensitivity are diminished due to the loss of signal at the fiber-air interface. The present invention overcomes the problem of loss at the interface, thus facilitating the use of high NA fibers for chemical sensing.

Egalon, Claudio O.↗

Diffraction image formation in optical systems with polarization aberrations. II - Amplitude response matrices for rotationally symmetric systems

In the previous paper in this series (McGuire and Chipman, 1990), a formulation was established for the calculation and analysis of diffraction image quality in polarizing optical systems illuminated with partially polarized, partially coherent light. In the present paper, the effect of second- and fourth-order polarization aberrations on the image plane diffraction patterns are examined. The amplitude response matrix is calculated for optical systems with small numerical apertures. Numerical results are presented for optical systems with circular apertures for three of the aberration types.

Mcguire, James P., Jr.↗

Design and analysis of a fast, two-mirror soft-x-ray microscope

During the past several years, a number of investigators have addressed the design, analysis, fabrication, and testing of spherical Schwarzschild microscopes for soft-x-ray applications using multilayer coatings. Some of these systems have demonstrated diffraction limited resolution for small numerical apertures. Rigorously aplanatic, two-aspherical mirror Head microscopes can provide near diffraction limited resolution for very large numerical apertures. The relationships between the numerical aperture, mirror radii and diameters, magnifications, and total system length for Schwarzschild microscope configurations are summarized. Also, an analysis of the characteristics of the Head-Schwarzschild surfaces will be reported. The numerical surface data predicted by the Head equations were fit by a variety of functions and analyzed by conventional optical design codes. Efforts have been made to determine whether current optical substrate and multilayer coating technologies will permit construction of a very fast Head microscope which can provide resolution approaching that of the wavelength of the incident radiation.

Shealy, D. L.↗

Micro-optic lens for data storage

A new type of microlens for data storage applications that has improved off-axis performance is described. The lens consists of a micro Fresnel pattern on a curved substrate. The radius of the substrate is equal to the focal length of the lens. If the pattern and substrate are thin, the combination satisfies the Abbe sine condition. Therefore, the lens is free of coma. We analyze a 0.5 numerical aperture, 0.50 mm focal length lens in detail. A 0.16 numerical aperture lens was fabricated holographically, and results are presented.

Milster, T. D.↗

Exploration of Double Clad Fibers for Increased Stability of Bidirectional Free Space Optical Links

Bidirectional, high data rate, low size, weight, and power (SWaP), and low cost free space optical links are needed for space communication applications to send and receive large volumes of data. We are exploring design strategies for optical transceivers to reduce SWaP and cost through increased misalignment tolerance (pointing requirement reduction) and sharing the optical transmit and receive paths (imposing optical symmetry). In applications where the detector is fiber coupled, the fiber numerical aperture is the main driver of the pointing accuracy requirement. Unfortunately, reducing the pointing requirement by increasing the fiber numerical aperture symmetrically causes instability in received power over small environmental changes. This paper explores double clad fibers as a solution to both reduce the power instability and increase the pointing accuracy tolerance. Double clad fibers can transmit a Gaussian beam from a single mode fiber and receive in a multi-mode aperture. Results show that double clad fiber have an improved misalignment tolerance and a higher stability for small changes in temperature when compared to single mode fibers and multimode fibers. Also, double clad fibers are shown to match the performance of an asymmetrical link design with a single mode transmit fiber and a multimode receive fiber.

Double Clad fibers↗

Exploration of Double Clad Fibers for Increased Stability of Bidirectional Free Space Optical Links

Bidirectional, high data rate, low size, weight, and power (SWaP), and low cost free space optical links are needed for space communication applications to send and receive large volumes of data. We are exploring design strategies for optical transceivers to reduce SWaP and cost through increased misalignment tolerance (pointing requirement reduction) and sharing the optical transmit and receive paths (imposing optical symmetry). In applications where the detector is fiber coupled, the fiber numerical aperture is the main driver of the pointing accuracy requirement. Unfortunately, reducing the pointing requirement by increasing the fiber numerical aperture symmetrically causes instability in received power over small environmental changes. This paper explores double clad fibers as a solution to both reduce the power instability and increase the pointing accuracy tolerance. Double clad fibers can transmit a Gaussian beam from a single mode fiber and receive in a multi-mode aperture. Results show that double clad fiber have an improved misalignment tolerance and a higher stability for small changes in temperature when compared to single mode fibers and multimode fibers. Also, double clad fibers are shown to match the performance of an asymmetrical link design with a single mode transmit fiber and a multimode receive fiber.

Double Clad fibers↗

Optical Analysis of an Ultra-High resolution Two-Mirror Soft X-Ray Microscope

This work has summarized for a Schwarzschild microscope some relationships between numerical aperture (NA), magnification, diameter of the primary mirror, radius of curvature of the secondary mirror, and the total length of the microscope. To achieve resolutions better than a spherical Schwarzschild microscope of 3.3 Lambda for a perfectly aligned and fabricated system. it is necessary to use aspherical surfaces to control higher-order aberrations. For an NA of 0.35, the aspherical Head microscope provides diffraction limited resolution of 1.4 Lambda where the aspherical surfaces differ from the best fit spherical surface by approximately 1 micrometer. However, the angle of incidence varies significantly over the primary and the secondary mirrors, which will require graded multilayer coatings to operate near peak reflectivities. For higher numerical apertures, the variation of the angle of incidence over the secondary mirror surface becomes a serious problem which must be solved before multilayer coatings can be used for this application. Tolerance analysis of the spherical Schwarzschild microscope has shown that water window operations will require 2-3 times tighter tolerances to achieve a similar performance for operations with 130 A radiation. Surface contour errors have been shown to have a significant impact on the MTF and must be controlled to a peak-to-valley variation of 50-100 A and a frequency of 8 periods over the surface of a mirror.

Shealy, David L.↗

Fiber Grating Coupled Light Source Capable of Tunable, Single Frequency Operation

Fiber Bragg grating coupled light sources can achieve tunable single-frequency (single axial and lateral spatial mode) operation by correcting for a quadratic phase variation in the lateral dimension using an aperture stop. The output of a quasi-monochromatic light source such as a Fabry Perot laser diode is astigmatic. As a consequence of the astigmatism, coupling geometrics that accommodate the transverse numerical aperture of the laser are defocused in the lateral dimension, even for apsherical optics. The mismatch produces the quadratic phase variation in the feedback along the lateral axis at the facet of the laser that excites lateral modes of higher order than the TM 00 . Because the instability entails excitation of higher order lateral submodes, single frequency operation also is accomplished by using fiber Bragg gratings whose bandwidth is narrower than the submode spacing. This technique is particularly pertinent to the use of lensed fiber gratings in lieu of discrete coupling optics. Stable device operation requires overall phase match between the fed-back signal and the laser output. The fiber Bragg grating acts as a phase-preserving mirror when the Bragg condition is met precisely. The phase-match condition is maintained throughout the fiber tuning range by matching the Fabry-Perot axial mode wavelength to the passband center wavelength of the Bragg grating.

Michael A Krainak↗

Fiber optics transmission of LV signal

The first use of a long optical fiber for transmitting megahertz frequencies in a laser velocimeter (LV) receiver system is reported. The fiber comprises a 600-micron diameter fused silica core, a silicon polymer cladding and a plastic jacket. The fiber numerical aperture is 0.22, corresponding to a maximum entrance half-angle of 0.22 rad. The 10-m length used results in a 5.6% attenuation loss. The fiber is found to transmit an 80-MHz signal with excellent resolution. It is established that an LV receiver using fiber optics sends a clean signal in electronically noisy and high-pressure environments and allows velocity measurements in places too small for a photomultiplier tube.

Young, A. D.↗

Determination of physical and chemical states of lubricants in concentrated contacts, part 3

Solid and liquid thin films were analyzed by infrared emission Fourier microspectrophotometry. The apparatus used is a commercial absorption instrument modified to an emission instrument, comprising a rotating polarizing device, a miniature blackbody temperature reference adjustable in temperature and radiant flux and a microscope lens with a high numerical aperture in the entrance system for increased sensitivity and resolution. Studies of lubricant behavior in a simulated ball bearing showed the alignment of the fluid molecules in the Hertzian area. Polyphenyl ether plus 1% 1,1,2-trichloroethane (TCE) required lower shear rates for the same degree of alignment than without TCE. The experiment was run with 440 C stainless steel balls coated with TiN, a chemically inert material. In both cases, the alignment was strongly influenced by the presence of TCE. The results showed (1) the dependence of alignment of fluid molecules on flow and not on adsorption at metallic surfaces, (2) phase separation between lubricant and additive under high pressure which results in two phase flow and (3) reduction in traction of torque transmitting (traction) fluids.

Lauer, J. L.↗

AVIRIS foreoptics, fiber optics and on-board calibrator

The foreoptics, fiber optic system and calibration source of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are described. The foreoptics, based on a modified Kennedy scanner, is coupled by optical fibers to the four spectrometers. The optical fibers allow convenient positioning of the spectrometers in the limited space and enable simple compensation of the scanner's thermal defocus (at the -23 C operating temp) by active control of the fiber focal plane position. A challenging requirement for the fiber optic system was the transmission to the spectral range 1.85 to 2.45 microns at .45 numerical aperture. This was solved with custom fluoride glass fibers from Verre Fluore. The onboard calibration source is also coupled to the spectrometers by the fibers and provides two radiometric levels and a reference spectrum to check the spectrometers' alignment. Results of the performance of the assembled subsystems are presented.

Chrisp, Michael P.↗

AVIRIS foreoptics, fiber optics and on-board calibrator

The foreoptics, fiber optic system and calibration source of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are described. The foreoptics, based on a modified Kennedy scanner, is coupled by optical fibers to the four spectrometers. The optical fibers allow convenient positioning of the spectrometers in the limited space and enable simple compensation of the scanner's thermal defocus (at the -23 C operating temp) by active control of the fiber focal plane position. A challenging requirement for the fiber optic system was the transmission to the spectral range 1.85 to 2.45 microns at .45 numerical aperture. This was solved with custom fluoride glass fibers from Verre Fluore. The onboard calibration source is also coupled to the spectrometers by the fibers and provides two radiometric levels and a reference spectrum to check the spectrometers' alignment. Results of the performance of the assembled subsystems are presented.

Chrisp, M. P.↗

Integrated Grating Spectrometer

Proposed integrated grating spectrometer made in waveguide layer on silicon wafer. Occupies area of about 2 centimeters to 2nd power on wafer 0.4 mm thick. Operates in visible spectrum (wavelengths of 400 to 700 nm) and blazed to diffract in first order. Array of integrated grating spectrometers performs spectral analysis of picture elements along line. Optical fiber couples light from each picture element into separate integrated spectrometer. Technique enables continous independent variation, along grating, of pitch, curvature, and blaze angle. Grating designed to have large numerical aperture, zero aberration at two selected wavelengths, and very low aberration at intermediate wavelengths.

Lang, Robert J.↗