Search NASASearch

SEARCH · Search NASA

Results for “numerical modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Numerical Modeling of the Transient Chilldown Process of a Cryogenic Propellant Transfer Line

Before cryogenic fuel depots can be fully realized, efficient methods with which to chill down the spacecraft transfer line and receiver tank are required. This paper presents numerical modeling of the chilldown of a liquid hydrogen tank-to-tank propellant transfer line using the Generalized Fluid System Simulation Program (GFSSP). To compare with data from recently concluded turbulent LH2 chill down experiments, seven different cases were run across a range of inlet liquid temperatures and mass flow rates. Both trickle and pulse chill down methods were simulated. The GFSSP model qualitatively matches external skin mounted temperature readings, but large differences are shown between measured and predicted internal stream temperatures. Discrepancies are attributed to the simplified model correlation used to compute two-phase flow boiling heat transfer. Flow visualization from testing shows that the initial bottoming out of skin mounted sensors corresponds to annular flow, but that considerable time is required for the stream sensor to achieve steady state as the system moves through annular, churn, and bubbly flow. The GFSSP model does adequately well in tracking trends in the data but further work is needed to refine the two-phase flow modeling to better match observed test data.

Temperature Sensors

Extending mARC II Arc-Jet Test Duration via Design and Implementation of Model System Cooling Sleeve

The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center used to generate high-enthalpy flows for low-cost thermal protection system (TPS) technology development. Sustained operation of downstream instrumentation and material samples is constrained by thermal loading transmitted through the arc-jet test environment, limiting achievable run times and experimental throughput. This work presents the design, integration, and validation of a cooling sleeve implemented on the sweep arm drive motor feedthrough to mitigate thermal accumulation during testing. The addition of the cooling sleeve is a simple, robust upgrade that translates directly into enhanced facility capability by supporting longer run durations, reduced turnaround time, and higher throughput.

numerical simulations

Extending mARC II Arc-Jet Test Duration via Design and Implementation of Model System Cooling Sleeve

The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center used to generate high-enthalpy flows for low-cost thermal protection system (TPS) technology development. Sustained operation of downstream instrumentation and material samples is constrained by thermal loading transmitted through the arc-jet test environment, limiting achievable run times and experimental throughput. This work presents the design, integration, and validation of a cooling sleeve implemented on the sweep arm drive motor feedthrough to mitigate thermal accumulation during testing. The addition of the cooling sleeve is a simple, robust upgrade that translates directly into enhanced facility capability by supporting longer run durations, reduced turnaround time, and higher throughput.

sting arm

Numerical Predictions of the Flow and Heat Transfer Characteristics in the Film Boiling Regime During Tube Quenching

Cryogenic fluid management plays a major role in refueling of spacecrafts while in space for NASA’s future human space exploration missions. Due to the low boiling points of cryogens, storage, transport and handling of these fluids becomes difficult and may result in inefficient operation of the space propulsion systems. For refueling applications in space, the cryogenic fluids have to be transported across different locations and hence, the transfer of cryogenic fluids through pipes become critical. The cryogenic chill-down process is characterized by different regimes of flow boiling, viz., film boiling, transition boiling and nucleate boiling. The prediction of these regimes in a single CFD framework available in the literature is challenging and the present work attempts to address this challenge by initially modeling the film boiling regime accurately and to incorporate an user-defined function for transition and nucleate boiling at a later stage. Hence, the aim of the present work is to numerically model and validate the film boiling regime of the chilldown curve for liquid nitrogen experiments available in the literature. The validations are carried out at different inlet mass fluxes to have a robust simulation methodology. A dispersed mixture model is used to predict the vapor-liquid interface dynamics with the phase change phenomena modeled using the Lee model.

line chilldown

Construction of an Exact Pressure-Equilibrium Scheme for the Five-Equation Two-Phase Flow Model With Thermal Relaxation

Numerical simulation of compressible multiphase flows based on the four-equation (homogeneous relaxation) model is known to suffer from two fundamental difficulties with (a) wave propagation and (b) pressure equilibrium preservation. First, the mixture sound speed exhibits non-monotonic dependency with respect to the volume fraction, which leads to robustness issues in the resolution of shocks and acoustic wave propagation across two-phase regions. This difficulty can be mitigated by solving Allaire’s five-equation model augmented with infinitely fast phasic temperature equilibrium, from which solutions of the four-equation model can be recovered. However, when temperature is non-uniform, this augmented five-equation formulation still fails to preserve pressure equilibrium across material interfaces. In this work, we propose a fully conservative numerical scheme that exactly preserves pressure equilibrium at the discrete level for the augmented five-equation model, for arbitrary initial distributions of temperature and volume fraction. Combined with the monotonic sound speed property of the five-equation formulation, the proposed pressure-equilibrium preserving scheme significantly improves robustness in the presence of strong multiphase interactions, including shock–interface interactions and advection of material interfaces.

ESG

Experimental and Numerical Investigation of the NASA High Efficiency Centrifugal Compressor Vaned Stage Geometry and Aerodynamic Performance

Since its inception in the early 2010s, the NASA High Efficiency Centrifugal Compressor (HECC) has been enigmatic for the propulsion research community: experimental data and numerical simulations of the stage have generally not aligned in their quantifications of performance metrics. Typically, the fault for these disagreements is assigned to the numerical simulations as the simulations are models, and models are inherently incomplete representations of the experiment. This “incompleteness” may manifest in assumptions regarding roughness or heat transfer, simplifications of the flow path (i.e., neglecting bleed flows), or the oft-scapegoated turbulence model. In the case of HECC, recent work showed unexpected discrepancies between the intended impeller geometry defined in the design report (termed Design-Intent) and the manufactured impeller used in the experimental campaigns (termed As-Manufactured). That work used numerical simulations to establish that the geometric differences between the Design-Intent and As-Manufactured impellers were significant enough to result in drastically different performance predictions for the HECC vaneless diffuser configuration. The Design-Intent impeller simulations over predicted the performance relative to the experiment, whereas the As-Manufactured simulations better represented the experimental data, both in terms of one-dimensional performance metrics and spanwise flow profiles. This effort expands on that work by examining in detail the geometry and aerodynamic performance of the HECC vaned diffuser configuration. Further differences between the Design-Intent and As-Manufactured geometries have been discovered in the vaned diffuser and exit guide vanes, and these differences are documented herein. The summations of the geometric differences for all of the components were used to create two numerical models of HECC vaned diffuser configuration: the Design-Intent simulations which are generated from the original geometry definitions given in the design report and the As-Manufactured simulations which are the best available representation of the manufactured compressor hardware used in the experimental test campaigns. In congruence with the earlier vaneless diffuser work, the numerical predictions of the Design-Intent choked mass flow rate, total pressure ratio, and efficiency were notably greater than that of the As-Manufactured simulations. To increase confidence in the experimental dataset, measurements from a recent test campaign conducted in 2024 are used to validate the original experimental data acquired from 2012 to 2014 with good repeatability overall, especially considering the passage of time and differences in the data acquisition systems between the test campaigns. Both numerical simulations were then extensively evaluated against the experimental data. The As-Manufactured simulations provided better estimates of the stage performance than the Design-Intent cases in terms of most performance metrics. Nonetheless, more detailed results still show opportunities for improvement. Despite a more accurate representation of the physical hardware, characterization of the impeller work input remains a challenge even for rigorously developed numerical models.

vaned diffuser

Experimental and Numerical Investigation of the NASA High Efficiency Centrifugal Compressor Vaned Stage Geometry and Aerodynamic Performance

Since its inception in the early 2010s, the NASA High Efficiency Centrifugal Compressor (HECC) has been enigmatic for the propulsion research community: experimental data and numerical simulations of the stage have generally not aligned in their quantifications of performance metrics. Typically, the fault for these disagreements is assigned to the numerical simulations as the simulations are models, and models are inherently incomplete representations of the experiment. This “incompleteness” may manifest in assumptions regarding roughness or heat transfer, simplifications of the flow path (i.e., neglecting bleed flows), or the oft-scapegoated turbulence model. In the case of HECC, recent work showed unexpected discrepancies between the intended impeller geometry defined in the design report (termed Design-Intent) and the manufactured impeller used in the experimental campaigns (termed As-Manufactured). That work used numerical simulations to establish that the geometric differences between the Design-Intent and As-Manufactured impellers were significant enough to result in drastically different performance predictions for the HECC vaneless diffuser configuration. The Design-Intent impeller simulations over predicted the performance relative to the experiment, whereas the As-Manufactured simulations better represented the experimental data, both in terms of one-dimensional performance metrics and spanwise flow profiles. This effort expands on that work by examining in detail the geometry and aerodynamic performance of the HECC vaned diffuser configuration. Further differences between the Design-Intent and As-Manufactured geometries have been discovered in the vaned diffuser and exit guide vanes, and these differences are documented herein. The summations of the geometric differences for all of the components were used to create two numerical models of HECC vaned diffuser configuration: the Design-Intent simulations which are generated from the original geometry definitions given in the design report and the As-Manufactured simulations which are the best available representation of the manufactured compressor hardware used in the experimental test campaigns. In congruence with the earlier vaneless diffuser work, the numerical predictions of the Design-Intent choked mass flow rate, total pressure ratio, and efficiency were notably greater than that of the As-Manufactured simulations. To increase confidence in the experimental dataset, measurements from a recent test campaign conducted in 2024 are used to validate the original experimental data acquired from 2012 to 2014 with good repeatability overall, especially considering the passage of time and differences in the data acquisition systems between the test campaigns. Both numerical simulations were then extensively evaluated against the experimental data. The As-Manufactured simulations provided better estimates of the stage performance than the Design-Intent cases in terms of most performance metrics. Nonetheless, more detailed results still show opportunities for improvement. Despite a more accurate representation of the physical hardware, characterization of the impeller work input remains a challenge even for rigorously developed numerical models.

centrifugal compressor

A Transient Hydrodynamic Model of Screen Channel Liquid Acquisition Devices for In-Space Cryogenic Propellant Management

Screen channel liquid acquisition devices (LADs) will play a crucial role in future deep space travel. It is essential that vapor-free delivery of propellants during tank-to-tank transfer is ensured to maximize yield from storage tanks and prevent potential combustion instabilities. The screen channel LAD utilizes a fine screen wire mesh that can separate phases in a low Bond number (i.e. microgravity) environment using surface tension forces. This study presents the development and verification of a new model for transient screen compliance, one of the influential factors for screen channel LAD design. Screen compliance is crucial during LAD channel outflow transients because the slight deflection of the screen can provide needed mass to satisfy rapid outflow demands and reduce the pressure difference across the screen. The model is successfully verified against CFD simulations. In addition, the characteristic speed for the governing screen compliance equations is derived which allows for numerical stability criteria to be established. As shown in this study, the transient maximum pressure difference across the screen can greatly exceed the steady state maximum pressure difference across the screen in many cases.

Hydrodynamics Simulations

Preparation of the Ice Certification of the Dornier 328 Regional Airliner By Numerical Simulation and By Ground Test

The Dornier 328, a new regional airliner, is to be qualified to FAR25/JAR25 requirements for operation into known icing conditions. All lifting surfaces are pneumatically deiced. Impingement limits were determined using a validated computational fluid dynamic (CFD) code. Wind tunnel tests with a model of the whole aircraft and the isolated empennage equipped with artificial ice shapes showed a degradation of handling characteristics due to ice accretion. Extensive two and three dimensional CFD calculations evaluated ice accretion at the deflection elevator horn. Icing tunnel tests were performed with a model of the horizontal tail with icing similitude fulfilled. The Dornier Do328 powerplant air induction system has successfully completed a program of icing tests in support of aircraft certification for operation into known icing conditions. Potential flight icing conditions were extensively analyzed using a CFD potential flow code and 3-D particle tracking routine to identify critical flight icing conditions. The tunnel test program verified the analytically predicted critical ice accretion surfaces of the air induction system, the adequacy of the ice protection provisions and demonstrated compliance with the applicable (JAR25) regulatory material.

D Welte

Transient Studies of G-Induced Capillary Dryout and Rewet

A transient, one-dimensional numerical code is developed to model the liquid motion in an axial groove with square cross section. Axial variation in liquid level, shear stress and heat transfer between the groove wall and the liquid, evaporation and transient body forces are accounted for in the model. Dryout and rewet of the groove are allowed; the front location is determined numerically using conservation of mass and linear extrapolation. Several numerical test results are presented and discussed.

M K Reagan

Numerical Investigation of Heat Transfer and Fluid Flow within Electrochemical Hydrogen Peroxide Generation Unit

Long-term manned space missions require the onboard production of disinfectants essential for maintaining crew health and supporting life systems. Currently, disinfection aboard the International Space Station (ISS) relies on disposable wetted wipes, which are regularly resupplied from Earth. This approach imposes a significant burden on resupply logistics, storage, and waste management. To address these challenges and support future missions, efforts are underway to develop an in-situ solution that electrochemically generates hydrogen peroxide disinfectant using onboard resources. In collaboration with NASA, Faraday Technology, Inc. has advanced this concept through a series of Small Business Innovation Research (SBIR) projects, resulting in the development of a Peroxide Generation Unit (PGU). The PGU can produce up to 3 wt.% hydrogen peroxide on-demand at a rate of 1 liter per day, providing a sustainable alternative to Earth-dependent supplies. The resulting aqueous hydrogen peroxide (H₂O₂) is an effective disinfectant, safe for crew use, compatible with spacecraft systems, and free from volatiles, off-gassing, or residues. This innovation offers a reliable, efficient solution for onboard disinfection, reducing dependence on Earth-based resupply while ensuring the health and safety of space crews. Generating hydrogen peroxide at the required rate needs high voltages and currents, exceeding 20V and 2A respectively, which leads to significant heat generation from Joule heating. This temperature rise poses a risk to sensitive system components, especially critical and expensive membranes that can degrade under thermal stress. To mitigate this risk, the thermal, fluid, and electrical flows within the system are modeled computationally using the commercial software COMSOL. The numerical simulations are validated against experimental data from both sub-scale and alpha-scale systems. Once verified, the model is employed to identify thermal hotspots, investigate their underlying causes, and explore solutions to prevent them.

Life Support Systems (LSS)

Mathematical Storage-Battery Models

Empirical formula represents performance of electrical storage batteries. Formula covers many battery types and includes numerous coefficients adjusted to fit peculiarities of each type. Battery and load parameters taken into account include power density in battery, discharge time, and electrolyte temperature. Applications include electric-vehicle "fuel" gages and powerline load leveling.

Chapman, C. P.

Numerical Solution of Fluid Flow and Heat Tranfer Problems with Surface Radiation

This paper presents a numerical scheme, based on the finite element method, to solve strongly coupled fluid flow and heat transfer problems. The surface radiation effect for gray, diffuse and isothermal surfaces is considered. A procedure for obtaining the view factors between the radiating surfaces is discussed. The overall solution strategy is verified by comparing the available results with those obtained using this approach. An analysis of a thermosyphon is undertaken and the effect of considering the surface radiation is clearly explained.

S Ahuja

Development and Experimental Validation of a Path-Dependent Spin Forming Finite Element Model

Spin forming is an advanced manufacturing process widely used in the aerospace and defense sectors to produce lightweight, high-strength cylindrical components with tight dimensional tolerances. This study explores the applicability of the path-dependent Mechanical Threshold Stress (MTS) constitutive model by simulating the evolution of geometry, machining forces, and plastic deformation during the spin forming of a 10-mm thick 6061-O aluminum cylinder. While numerical modeling of spin forming has advanced substantially over the past decade, systematic verification and experimental validation of material models remain limited, particularly in predicting through-thickness process evolution. The MTS model, incorporating a Voce hardening rule, is employed for its ability to represent cyclic loading, rapidly varying temperature fields, and strain rates characteristic of spin forming. Numerical convergence analysis indicates discretization uncertainties between 0.3% and 9.2% for key quantities of interest. Experimental validation demonstrates that the MTS model, when implemented with a verified mesh, accurately reproduces both elastic and plastic behavior of 6061-O aluminum, predicting peak roller loads within 11–18% of measurements, geometric tolerances within 3%, and plastic strain distributions within 10% of experimental values. Collectively, these results establish a validated computational framework for predictive spin-forming simulations with quantified confidence, providing a foundation for extension to other alloys, geometries, and forming conditions.

Spin forming

Material Properties and Modeling of Room Temperature Vulcanizing Silicone

Room Temperature Vulcanizing silicone (RTV) is a high-temperature adhesive that has successfully been used as a gap-filler between Thermal Protection System (TPS) tiles for heatshields on numerous missions. It is also used to bond instrumentation plugs such as temperature and pressure sensors into the heatshields. While RTV has been traditionally assumed to be a non-porous and non-ablating material, numerous experiments have shown that RTV pyrolyzes and becomes highly porous as it is heated. Heating RTV has also shown swelling, or intumescence, which can pose unique problems that lead to roughness induced boundary-layer transition, surface oxide formation and contamination of heat shield sensors. Therefore, it is crucial to understand and model the intumescence phenomenon of RTV. As data for RTV material properties is limited, the first step in modeling RTV is to collect material properties such as pyrolysis mass-loss, microstructure change, virgin and char porosity, etc. which was performed in our initial study. Additionally, thermomechanical properties such as Young’s modulus and Poisson ratio are required for modeling the intumescence of RTV, which were taken from literature and the coefficient of thermal expansion was collected using in-situ heating and Micro Computed Tomography (µ-CT) in previous studies. Finally, numerous other properties such as pyrolysis gas properties, virgin and char thermal conductivity and specific heat were compiled from previous experiments and literature into a material database that can be used for simulations. In Porous Material Analysis Toolbox based on OpenFOAM (PATO) [4], structural mechanics coupled with material response was used for simulating the intumescence of RTV as it is heated. However, since the permeability of the material is very low, the pyrolysis gas creates an internal pressure build-up as the material is being heated, significantly contributing to the deformation of the material. To correctly characterize this phenomenon, additional physics models were implemented into PATO's stress analysis solver, and results were compared with RTV dilatometry test data as a preliminary verification case. Future work will include experiments of RTV at the Plasmatron X facility and the in-situ heating cell with µ-CT, and improvement of simulation tools to more accurately model RTV intumescence.

PATO

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe