Advanced co-simulation framework for assessing the interplay between occupant behaviors and demand flexibility in commercial buildings

With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Data-driven modeling of dynamic occupant thermostat override behavior for demand response applications

Buildings consume nearly 40% of global energy and produce similar emissions. Whiletechnological advances address efficiency, occupant behavior causes energy use variations up to 300% between identical buildings. This gap between predicted and actual building performance impacts building design, operations, and grid demand management programs. Through analyses of smart thermostat data from 1,400 single-occupant homes, the researchdemonstrates that occupants respond to 8°F thermostat setpoint changes within a median of 15 minutes, while 2°F changes trigger responses within a median of 30 minutes. This highlights an understudied temporal relationship between thermostat setbacks and response time of occupant behaviors. Models of such behavior dynamics are required to incorporate occupant impacts into building performance simulation. A key contribution of this dissertation is the Thermal Frustration Theory (TFT), which positsthat thermal discomfort driven behaviors are caused by the time-accumulation of discomfort, not simply a temperature deviation threshold or a delay from an initiating event. Using a dataset of 634 thermostats, each with 25+ manual setpoint changes, a comparative analysis of TFT and comfort zone and a delayed response theories demonstrated that personalized TFT models better predict when manual setpoint change occur. This was measured by the area under the curve statistical measure (AUC); all three models perform similarly by a Matthews Correlation Coefficient measure. Higher AUC performance is especially important for modeling occupant behavior in demand response programs where false negatives of rare occupant interactions could adversely affect grid stability. EnergyPlus based simulations were conducted with TFT-derived occupant models, demonstrating the ability to identify parameters of known TFT models from only data observable with smart thermostats, even under the presence of noise from routine overrides. Overall, the dissertation highlights that thermostat interactions are neither static,instantaneous, nor driven solely by the environment. Instead, temporal accumulation of discomfort and routine-based behavior play important roles. The methodology and results offer a pathway towards more accurate modeling of human-building interactions for policy assessment, building design, and demand response programs.

Sharma, Kunind [Northeastern University] (ORCID:00

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

NMF-Based Anomaly Detection in CMS 2D Tracking Occupancy Histograms

The CMS experiment relies on Data Quality Monitoring (DQM) to ensure that recorded collision data are suitable for physics analysis. During LHC Run 3, each run contains many lumisections and tracking monitoring elements, making offline inspection challenging, especially for localized detector effects that may appear only for short periods of time. This poster presents an unsupervised machine-learning approach to identify anomalous lumisections in CMS tracking occupancy histograms using Non-Negative Matrix Factorization (NMF). The workflow uses offline CMS DQMIO tracking histograms retrieved with the CMS DIALS API and organized as two-dimensional occupancy maps for each lumisection. After selecting stable lumisections, the occupancy maps are normalized and arranged into a non-negative data matrix. The NMF model learns a compact set of basis patterns describing normal tracking occupancy. Each lumisection is then reconstructed from these learned components, and the reconstruction error is used as an anomaly score. Large residuals indicate occupancy patterns that deviate from normal detector behavior and are flagged for further inspection. This NMF-based approach provides a fast and interpretable way to flag lumisections whose tracking occupancy patterns differ from normal detector behavior. Preliminary studies show sensitivity to known tracking anomalies, and ongoing work is focused on validating the method across additional Run 3 Pixel and Strip detector issues.

Rodríguez Ramos, Iliomar [Puerto Rico U., Mayaguez

Common occupational classification system amendments for Accelerator Science and Engineering workforce

A common system to classify occupations and skills is essential to support accelerator workforce planning between the Department of Energy (DOE) National Laboratories. In 2025, ten DOE laboratories conducted a census of their accelerator science and engineering workforce and projected their accelerator workforce needs for the next ten years. To support this, revision 3 of the “Common Occupational Classification System” (COCS) was used as a common taxonomy. Modifications were made to include accelerator-specific skills and specialisms. COCS was originally developed for DOE Office of Environmental Restoration and Waste Management in 1996. The framework provides a high-level functional structure that can be expanded with further occupations and specialisms and remains well aligned to DOE laboratory roles nearly 30 years later. Accelerator occupations and specialisms were added to the framework for the 2025 effort to quantify the accelerator workforce. This document is a companion document to COCS and provides a definition for these new occupations and specialisms that do not appear in COCS. Proceeding with a stable taxonomy is seen as essential such that its use becomes easier each year; the taxonomy as used for the 2025 effort is recommended to be continued.

43 PARTICLE ACCELERATORS

Enhancing occupant behavior representation for interoperability between building information modeling and building energy modeling

Building Performance Simulation (BPS) has been adopted as an essential tool for designing, operating, and retrofitting buildings to optimize energy efficiency throughout the building life cycle. The Green Building XML (gbXML) schema facilitates seamless data exchange between Building Information Modeling (BIM) and Building Energy Modeling (BEM) software tools. However, limited occupant behavior (OB) representation in BIM often leads to inconsistent and inaccurate energy simulation in BEM software. This paper presents 154 systematic enhancements to the existing occupant behavior XML (obXML) schema v1.3.4, initially developed for standardizing OB representation for BEM, to address existing limitations and improve interoperability with BIM models. The enhancements encompass improved integration with BIM models through extended building representations and system operations, expanded support for advanced OB models with additional environmental parameters and mathematical capabilities, and implementation of a standardized model documentation framework. To facilitate seamless data transformation between gbXML and obXML schemas, we developed a publicly available gb-obXML Schema Converter. Three case studies demonstrate the enhanced schema’s capabilities: representation of building information using a two-story office building model, documentation of a window operation behavior model, and validation of the schema converter’s functionality. The enhanced obXML schema v1.4 enables sophisticated modeling of occupant-building interactions while maintaining consistency with industry-standard BIM schemas. The standardized documentation framework facilitates reproducibility and knowledge sharing in the OB research community, while the schema converter automates the integration of building information into OB simulation workflows. These enhancements establish a foundation for more accurate building performance simulation by supporting sophisticated representation of occupant behavior within the BIM-to-BEM simulation workflows.

Chung, Jihoon

Occupational Radiation Exposure Report for Calendar Year 2023

The U.S. Department of Energy Occupational Radiation Exposure Report for Calendar 2023 presents the results of analyses of occupational radiation exposures at the U.S. Department of Energy (DOE), including the National Nuclear Security Administration (NNSA) operations, during calendar year 2023. This report includes occupational radiation exposure data for over 80,000 DOE Federal employees, contractors, and subcontractors as well as members of the public who have worked in or entered controlled areas monitored for exposure to radiation. DOE publishes this annual report to provide DOE Management, Program Offices, workers, health physicists, and other stakeholders an evaluation of DOE-wide performance regarding compliance with Title 10 of the Code of Federal Regulations (CFR) Part 835, Occupational Radiation Protection (10 CFR 835) radiation exposure limits and adherence to as low as reasonably achievable principles. This report provides a discussion regarding radiation protection and exposure reporting requirements. It also includes calendar year (CY) 2023 information and analyses regarding aggregate, individual, site, DOE Program, transient individuals’ dose, as well as a historical review of DOE exposure data. DOE continues to be diligent in protecting its workers and the public from exposure to radiation from DOE operations as illustrated by the results contained in this report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

A prototype cooling blanket for mitigating occupant overheating risk in a hot indoor environment: Modeling and assessments

Conventional ways of cooling a room or an entire house for occupant thermal comfort during summer consume a significant amount of energy and are vulnerable to overheating risk during power outages that lead to loss of cooling system operations. This study investigates a low-power cooling blanket, as a Personal Cooling System (PCS), that covers the upper human body for direct cooling during a five-day heat wave in a single-family house. A modeling framework is developed for evaluating the thermal and energy performance of the cooling blanket, which builds upon the co-simulation of three models: a house energy model, a personal thermal comfort model, and a cooling blanket model. Simulation results show that under the power outage scenario, the cooling blanket can greatly reduce the occupant heat stress with a reduction of daily hours of exceedance (discomfort hours defined as TSV>2) by up to 17.2 h (a 95.3 % improvement from the baseline power outage without the blanket). The cooling blanket, equipped with an innovative electrocaloric heat pump (COP as high as 10.1) consumes 6.31 W and can be operated by a portable battery for several days. The cooling blanket consumes only 0.28 % of the electricity of a central air-conditioning system running to provide cooling for the whole house during the five-day heatwave period. The findings justify further research of electrocaloric wearable PCS as low-power effective cooling to ensure thermal survivability of occupants during extreme indoor environments.

Electrocaloric heat pump

A practical control strategy for demand flexibility with ensured occupant comfort in grid-interactive efficient buildings

This study proposes a practical and simplified demand response (DR) control strategy from the perspective of grid-interactive efficient buildings (GEBs), aiming to secure demand flexibility while ensuring occupant thermal comfort. Focusing on summer on-peak periods, a linear demand response (LDR) strategy that integrates cooling setpoint adjustment and lighting dimming was designed, and its performance was quantitatively evaluated. A case study was conducted using EnergyPlus-based simulations for a U.S. DOE small office prototype building under summer on-peak weather conditions. Compared with a conventional rapid demand response (RDR) strategy, the proposed LDR approach gradually reduced electrical loads while maintaining occupant thermal comfort indices, including predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), within acceptable comfort ranges. Quantitative analysis of demand flexibility using the grid-interactive impact index (GII) and the flexibility strength index (FSI) showed that the LDR strategy provided approximately 12.5% demand flexibility during DR periods and achieved an electricity cost reduction of about 8.8%. In addition, the results of the part-load ratio (PLR)-based cooling system performance analysis showed that, in the on-peak period, the LDR strategy exhibited improved cooling performance compared with the baseline. Overall, this study shows the potential of a practical DR control strategy that can simultaneously achieve occupant comfort and demand flexibility without relying on complex advanced control technologies.

Jung, Dong Eun

Modulating coordinate site occupancy in high-entropy spinel electrocatalysts

High entropy spinel oxides provide a versatile platform for electrocatalysis because multiple metal cations can be incorporated into a single crystalline lattice, enabling tunable electronic structures. However, controlling how these cations distribute between tetrahedral and octahedral coordination sites remains a major challenge, limiting rational catalyst design. Here, we modulate cation coordination site occupancy between tetrahedral and octahedral sites in a Co–Fe–Cr–Mn–Ni framework by introducing a sixth cation (Zn, Ga, Mg, or Al) with distinct site preference energies. Using density functional theory, synchrotron X-ray absorption spectroscopy, and magnetic circular dichroism, we demonstrate that Zn preferentially occupies tetrahedral sites, driving increased octahedral occupancy of cobalt. This redistribution increases the population of octahedrally coordinated cobalt in mixed oxidation states, enhances electrical conductivity, and improves oxygen evolution reaction activity. Our findings establish coordination site occupancy as a critical design parameter, providing a strategic pathway for tailoring multicomponent spinel electrocatalysts with optimized performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Simultaneous occupancy of Cu C and Cu D in the ammonia monooxygenase active site

Ammonia monooxygenase (AMO), a copper-dependent membrane enzyme, catalyzes the first and rate-limiting step of nitrification: the oxidation of ammonia to hydroxylamine. Despite its central role in the global nitrogen cycle and its biotechnological relevance, structural characterization of AMO has lagged behind that of its homolog, particulate methane monooxygenase (pMMO), due to the slow growth rates of ammonia-oxidizing bacteria and the instability of AMO upon purification. Recent cryoEM studies of Nitrosomonas europaea AMO and Methylococcus capsulatus (Bath) pMMO in native membranes revealed new structural features, including two adjacent copper-binding sites in the transmembrane region, Cu C and Cu D , believed to constitute the active site. Although multiple structures were determined under various conditions, simultaneous occupancy of Cu C and Cu D was never observed, leaving their potential functional interplay unresolved. Here we report the 2.6 Å resolution cryoEM structure of AMO from Nitrosospira briensis C-128 in isolated native membranes. This structure reveals the first instance of simultaneous copper occupancy of the Cu C and Cu D sites, along with occupancy of the periplasmic Cu B site. Electron paramagnetic resonance (EPR) spectroscopic data indicate that the Cu B site is primarily occupied by Cu(II), while Cu C and Cu D are primarily occupied by diamagnetic ions, presumably Cu(I). Notably, a lipid molecule is bound between the Cu C and Cu D sites, separating them by ∼8.0 Å. The results underscore the importance of studying these enzymes in their native environments across species to resolve conserved and divergent molecular features.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Hot, Cold, or Just Right? Using a Wide-View Infrared Biometric Sensor to Improve Occupant Comfort and Reduce Overcooling in Buildings via Closed-loop Control (CRADA Final Report)

This research adds to the understanding of building energy management by fundamentally challenging the long-standing paradigm of controlling an environmental parameter—air temperature—and assuming occupant comfort will follow. The project developed and demonstrated a novel approach that directly senses physiological indicators of human comfort to enable closedloop, human-centric control of heating, ventilation, and air conditioning (HVAC) systems. This work shifts the focus from open-loop environmental control to a closed-loop system that prioritizes the occupants' actual thermal state. The primary benefit to the public is the potential for a simultaneous improvement in the quality of indoor environments, where people spend most of their time, and a significant reduction in national energy consumption. Overcooling, or the overuse of cooling energy in a way that discomforts occupants, wastes approximately 0.5 Quads of primary energy annually in U.S. commercial buildings and creates unproductive indoor environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Respiration Signal Pattern Analysis for Doppler Radar Sensor with Passive Node and Its Application in Occupancy Sensing of a Stationary Subject

Doppler radar node occupancy sensors are promising for applications in smart buildings due to their simple circuits and price advantage compared to quadrature radar sensors. However, single-channel sensitivity limitations may result in low sensitivity and misinterpreted motion rates if the detected subject is at or close to “null” points. We designed and tested a novel method to eliminate such limits, demonstrating that passive nodes can be used to detect a sedentary person regardless of position. This method is based on characteristics of chest motion due to respiration, found via both simulations and experiments based on a sinusoidal model and a more realistic model of cardiorespiratory motion. In addition, respiratory rate variability is considered to distinguish a true human presence from a mechanical target. Sensor node data were collected simultaneously with an infrared camera system, which provided a respiration signal reference, to test the algorithm with 19 human subjects and a mechanical target. The results indicate that a human presence was detected with 100% accuracy and successfully differentiated from a mechanical target in a controlled environment. The developed method can greatly improve the occupancy detection accuracy of single-channel radar-based occupancy sensors and facilitate their adoption in smart building applications.

Song, Chenyan

StOKeDMD: Streaming Occupation kernel dynamic mode decomposition

Dynamic mode decomposition (DMD) has become a common technique for constructing surrogate models for dynamical systems from observed system states. The Occupation Kernel DMD (OKDMD) method proposed in (Rosenfeld et al., 2022) and (Rosenfeld et al., 2024) is a Liouville operator based method that builds surrogate models from system state trajectories. Here, this paper proposes an extension of OKDMD to the case when the system states are observed in a streaming fashion, i.e., only a small fraction of the state trajectory is available at a given time. The developed method, Streaming Occupation Kernel DMD (StOKeDMD), accommodates the streaming data input by leveraging properties of specific choices of kernel functions and occupation kernels. We apply the StoKeDMD method as a compression method for streaming data, analyze the memory complexity, and demonstrate the performance of StoKeDMD in the compression of streaming data generated from a Lorenz system and a fluid flow simulation.

97 MATHEMATICS AND COMPUTING

Determination of Site Occupancy in the M–Pd–Zn (M = Cu, Ag, and Au) γ-Brass Phase by CALculation of PHAse Diagrams Modeling and Rietveld Refinement

The Pd–Zn γ-brass phase provides exciting opportunities for synthesizing site-isolated catalysts with precisely controlled Pd active site ensembles. Introducing a third metallic element into the γ-brass lattice further perturbs the catalytic active site ensembles. Here, in this work, we introduce coinage metallic elements M (M = Cu, Ag, and Au) into the Pd–Zn γ-brass phase and investigate the site occupation factors of each element in the γ-brass lattice. The CALculation of PHAse Diagrams (CALPHAD) modeling approach supported by energetics predicted by the density functional theory and X-ray and neutron diffraction with Rietveld refinement were used to identify the SOF on each Wyckoff site for various M amounts alloyed into the Pd–Zn γ-brass phase. The present analysis unveils the strong preference for Pd occupying the outer tetrahedral (OT) site in the γ-brass lattice, while the coinage metallic elements tend to substitute for Zn on the octahedral (OH) site. The determination of site occupancy in the bulk M–Pd–Zn γ-brass phase provides opportunities to investigate and tailor potential catalytically active site ensembles in the γ-brass phase materials.

36 MATERIALS SCIENCE

Seasonal changes in occupancy and activity patterns in native Collared Peccary and non-native wild pig and Common Warthog in southern Texas, the United States

Abstract Southern Texas, USA, is home to native collared peccaries (Dicotyles tajacu) and introduced populations of invasive wild pigs (generally Sus scrofa × domesticus hybrids) and non-native African warthogs (Phacochoerus africanus). Although these ecologically similar mammals co-occur in this region, the potential impacts of invasive suids on collared peccaries are poorly understood. We examined co-occupancy and activity pattern overlap of collared peccaries, wild pigs, and warthogs across 3 seasons (fall, winter, and spring) using remote camera data collected from Chaparral Wildlife Management Area, Cotulla, Texas (November 2020 to June 2021). Using activity pattern analyses and single and 2-species occupancy models incorporating habitat and climate characteristics, we found evidence of extensive spatial overlap between all species pairs and varying degrees of temporal overlap depending on species pairs and season. Collared peccaries and wild pigs displayed moderate temporal overlap across all seasons. Collared peccaries appeared to alter fall activity in the presence of wild pigs to be active earlier in the morning and less active during the day. Collared peccaries and warthogs had low-to-moderate temporal overlap (low in fall, winter; moderate in spring). Wild pigs and warthogs had low temporal overlap (fall, spring) and wild pigs appeared to alter activity in the presence of warthogs (fall), becoming less active during the day during peak warthog activity. Overall, our results suggest that peccary, wild pig, and warthog interactions and activity are dynamic and vary seasonally according to the ecology and preferred environmental conditions of each species. Given the potential for interspecific competition and disease transmission with Collared Peccary and other native wildlife, resource partitioning between wild pigs and warthogs needs to be further examined to aid in effective management strategies.

Kupferman, Caitlin A. (ORCID:0009000953554860)