Search NASA⌕ Search

SEARCH · Search NASA

Results for “off-design modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Demonstration System for Geological Thermal Energy Storage of Concentrating Solar Thermal

Energy storage is increasingly necessary as variable energy technologies are deployed. Seasonal energy storage can shift energy generation from the summer to the winter, but these technologies must have extremely large energy capacities and low costs. Geological Thermal Energy Storage (GeoTES) is proposed as a solution for long-term energy storage [1]. Excess thermal energy can be stored in permeable reservoirs such as aquifers and depleted hydrocarbon reservoirs for several months. The energy capacity cost of GeoTES is very low which makes it suitable for both daily- and seasonal storage of Concentrating Solar Thermal (CST) energy, thus enabling CST to provide value to electricity markets and thermal energy off-takers. A CST-GeoTES demonstration system has been funded by the U.S. Department of Energy, Solar Energy Technology Office. In this article, we will describe this demonstration system and progress that has been made in its development. The demonstration system will comprise a 2 MWth parabolic trough with an 8m aperture developed by Gossamer Space Frames, seven wells, and a 100 kWe power cycle. The demonstration system will be deployed in Kern County, California by Premier Resource Management. A techno-economic model for CST-GeoTES systems has also been developed [3] and is applied to the demonstration system and its planned future expansion. The model integrates the output of specialist models of each subsystem, which enables the performance and cost of both the subsurface and surface systems to be captured. Off-design models enable the performance to be evaluated at each hour of the year, before being aggregated to evaluate the economic potential of CST-GeoTES. Initial analysis indicates that CST-GeoTES can provide long duration energy storage capabilities with low marginal costs of energy capacity - leading to a low value of Levelized Cost of Storage (LCOS) compared to alternative technologies, see Figure 2. In this article, we investigate the cost and performance of the specific demonstration site being developed by PRM and explore a range of operational profiles that can deliver different value streams, such as daily and seasonal storage, capacity, and resiliancy.

14 SOLAR ENERGY↗

A Dual-Mode Hybrid System Combining Solar Thermal With Pumped Thermal Energy Storage

A hybrid system that delivers renewable electricity generation and electricity storage capabilities is introduced. This dual-mode hybrid system is based on Pumped Thermal Energy Storage (PTES) which uses a heat pump to convert electricity into thermal energy that is trans-ferred to silica particles which are stored in concrete silos. The stored heat is later converted back to electricity in a heat engine. The heat pump and heat engine use a closed Joule-Brayton cycle and fluidized bed heat exchangers. If the PTES system is co-located with an array of concentrating solar mirrors and a particle receiver, then the silica particles may also be heated up by the concentrating solar power (CSP) system. The PTES heat engine may also be used to convert the stored solar heat into electricity, thereby sharing this system between the PTES and CSP systems and reducing costs. However, this requires careful management of the heat engine off-design parameters. A thermodynamic model is used to evaluate the performance of the dual mode PTES-CSP hybrid system. The model accounts for turbomachinery effi-ciency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The hybrid system also requires the evaluation of the turbomachinery efficiency and pressure ratio at off-design conditions since the CSP system operates over different temperature ratios than the Carnot Battery. Several design variables and design modifications are investigated, such as pressure ratios and maximum temperatures.

14 SOLAR ENERGY↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

Techno-economic comparison of sCO 2 cycles for particle-based CSP at design-point conditions

In this work, we compare the techno-economic performance of supercritical carbon dioxide power cycles integrated in a particle CSP system. We model four core cycle configurations: simple (with optional bypass), recompression (with optional bypass), partial cooling, and turbine split flow, which each demonstrate different benefits in a CSP system, such as high efficiency, low cost, or large HTF temperature differences. We parametrically sweep cycle design variables for each configuration. The set of power cycle performance results are then combined with a design point particle CSP system model which calculates the system specific cost. The simple cycle and turbine split flow cycles have the best performance in the baseline results, with system specific costs of 5,912 and 5,899 $\$$/kWe respectively. In addition to the baseline set of results, we also vary key parameters and costs in a sensitivity study. The cycle designs with the best system performance limit their efficiency to ~45 %, despite demonstrating higher maximum efficiencies, due to the rapid increase in cost of recuperation as efficiencies rise. The simple cycle has strong performance in the analysis and is on average only 1.4 % worse than the optimal configuration. Lowered turbine inlet temperatures from the sensitivity study improve performance by reducing the PHX and turbine cost. Decreasing the inlet temperature from 700 to 625°C results in an >8 % decrease in system specific cost. Future work should expand sensitivity analyses to colder turbine inlet temperatures and calculate system performance by simulating annual performance with off-design solar and cycle component models.

14 SOLAR ENERGY↗

Computer Program for the Design and Off-Design Performance of Turbojet and Turbofan Engine Cycles

The rapid computer program is designed to be run in a stand-alone mode or operated within a larger program. The computation is based on a simplified one-dimensional gas turbine cycle. Each component in the engine is modeled thermo-dynamically. The component efficiencies used in the thermodynamic modeling are scaled for the off-design conditions from input design point values using empirical trends which are included in the computer code. The engine cycle program is capable of producing reasonable engine performance prediction with a minimum of computer execute time. The current computer execute time on the IBM 360/67 for one Mach number, one altitude, and one power setting is about 0.1 seconds. about 0.1 seconds. The principal assumption used in the calculation is that the compressor is operated along a line of maximum adiabatic efficiency on the compressor map. The fluid properties are computed for the combustion mixture, but dissociation is not included. The procedure included in the program is only for the combustion of JP-4, methane, or hydrogen.

Morris, S. J.↗

Effect on Inlet Performance of a Cowl Visor and an Internal-Contraction Cowl for Drag Reduction at Mach Numbers 3.07 and 1.89

Two methods for reducing the external cowl angle, and hence the cowl pressure drag, were investigated on a two-dimensional model. One method used at both on- and off-design Mach numbers was the addition of a cowl visor that had the inner surface parallel to the free stream at 0 deg angle of attack. The other method investigated consisted in replacing the original cowl by a flatter cowl that also provided internal contraction. Both the visor and the internal-contraction cowl reduced the cowl pressure drag 64 percent or more. The visor had little effect on inlet performance at the design Mach number except to reduce the stability range slightly. At off-design, the visor caused an increase in critical pressure recovery.

Gertsma, Laurence W.↗

A Theory for Stability and Buzz Pulsation Amplitude in Ram Jets and an Experimental Investigation Including Scale Effects

From a theory developed on a quasi-one-dimensional-flow basis, it is found that the stability of the ram jet is dependent upon the instantaneous values of mass flow and total pressure recovery of the supersonic diffuser and immediate neighboring subsonic diffuser. Conditions for stable and unstable flow are presented. The theory developed in the report is in agreement with the experimental data of NACA-TN-3506 and NACA-RM-L50K30. A simple theory for predicting the approximate amplitude of small pressure pulsation in terms of mass-flow decrement from minimum-stable mass flow is developed and found to agree with experiments. Cold-flow tests at a Mach number of 1.94 of ram-jet models having scale factors of 3.15:1 and Reynolds number ratios of 4.75:1 with several supersonic diffuser configurations showed only small variations in performance between geometrically similar models. The predominant variation in steady-flow performance resulted from the larger boundary layer in the combustion chamber of the low Reynolds number models. The conditions at which buzz originated were nearly the same for the same supersonic diffuser (cowling-position angle) configurations in both large and small diameter models. There was no appreciable variation in stability limits of any of the models when the combustion-chamber length was increased by a factor of three. The unsteady-flow performance and wave patterns were also similar when considered on a reduced-frequency basis determined from the relative lengths of the model. The negligible effect of Reynolds number on stability of the off-design configurations was not anticipated in view of the importance of boundary layer to stability, and this result should not be construed to be generally applicable. (author)

Trimpi, Robert L↗

Summary report of the second wind tunnel test of the Boeing LFC model

An 8-ft span, 20-ft chord, 30 deg swept wing section having provisions for laminar boundary control over the first 30% of the upper surface and the first 15% of the lower surface was tested in a 5-ft by 8-ft wind tunnel to explore the sensitivity of laminar flow to various forms of disturbances such as surface imperfections, contamination, off-design pressure distribution (increased crossflow), and imposed noise. The test equipment used and instrumentation of the model are described. Typical results obtained from configurations with spanwise ridges and spanwise rows of disks are discussed as well as suction flow characteristics at reduced incidence.

George-Falvy, D.↗

Supercritical wing sections II: A handbook

The numerical aspect of theoretical work on transonics and supercritical wing sections are compiled. A model of the trailing edge is introduced which eliminates the loss of 15 to 20 percent experienced with heavily aft-loaded models, and it is indicated how drag creep can be reduced at off-design conditions. A rotated finite difference scheme is presented which can handle supersonic as well as subsonic free stream Mach numbers and leads to an effective three-dimensional program for the computation of transonic flow past an oblique wing. In the case of two-dimensional flow, the method is extended to take into account the displacement thickness computed by a semiempirical turbulent boundary layer correction. A series of supercritical wing sections is discussed together with comparisons between experimental and theoretical data. Computer programs and a brief manual for their operation are listed. It is shown that the programs furnish a physically adequate computer simulation of the compressible flows that arise in problems of transonic aerodynamics.

Bauer, F.↗

Supercritical wing sections 2, volume 108

A mathematical theory for the design and analysis of supercritical wing sections was previously presented. Examples and computer programs showing how this method works were included. The work on transonics is presented in a more definitive form. For design, a better model of the trailing edge is introduced which should eliminate a loss of fifteen or twenty percent in lift experienced with previous heavily aft loaded models, which is attributed to boundary layer separation. How drag creep can be reduced at off-design conditions is indicated. A rotated finite difference scheme is presented that enables the application of Murman's method of analysis in more or less arbitrary curvilinear coordinate systems. This allows the use of supersonic as well as subsonic free stream Mach numbers and to capture shock waves as far back on an airfoil as desired. Moreover, it leads to an effective three dimensional program for the computation of transonic flow past an oblique wing. In the case of two dimensional flow, the method is extended to take into account the displacement thickness computed by a semi-empirical turbulent boundary layer correction.

Bauer, F.↗

Evaluation of Rankine cycle air conditioning system hardware by computer simulation

A computer program for simulating the performance of a variety of solar powered Rankine cycle air conditioning system components (RCACS) has been developed. The computer program models actual equipment by developing performance maps from manufacturers data and is capable of simulating off-design operation of the RCACS components. The program designed to be a subroutine of the Marshall Space Flight Center (MSFC) Solar Energy System Analysis Computer Program 'SOLRAD', is a complete package suitable for use by an occasional computer user in developing performance maps of heating, ventilation and air conditioning components.

Healey, H. M.↗

Computations in turbulent flows and off-design performance predictions for airframe-integrated scramjets

The research activity focused on two main tasks: (1) the further development of the SCRAM program and, in particular, the addition of a procedure for modeling the mechanism of the internal adjustment process of the flow, in response to the imposed thermal load across the combustor and (2) the development of a numerical code for the computation of the variation of concentrations throughout a turbulent field, where finite-rate reactions occur. The code also includes an estimation of the effect of the phenomenon called 'unmixedness'.

Goglia, G. L.↗

Next Generation Heat Transfer Fluids for Two-Phase Immersion Cooling of Data Centers

The purpose of this study is to evaluate the performance of next generation dielectric fluids in a Two-Phase Immersion Cooling (2PIC) system, which was designed for use in data centers. Hence, this report contains the performance evaluations of a new developmental dielectric fluid, Opteon™ 2P50, in a commercially available small-scale 2PIC system under typical and off-design range of operating conditions. Accordingly, ambient temperature and thermal loads were varied to simulate different ambient conditions. Additionally, this research report describes the development of a semi-empirical lumped model to predict the energy efficiency of the 2PIC system using Opteon™ 2P50 across a wide range of conditions. The model aims to offer a comprehensive understanding of the system’s efficiency and potential improvements. The outcomes of this study are expected to contribute to the adoption of sustainable 2PIC cooling technologies in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DYNGEN: A program for calculating steady-state and transient performance of turbojet and turbofan engines

The DYNGEN, a digital computer program for analyzing the steady state and transient performance of turbojet and turbofan engines, is described. The DYNGEN is based on earlier computer codes (SMOTE, GENENG, and GENENG 2) which are capable of calculating the steady state performance of turbojet and turbofan engines at design and off-design operating conditions. The DYNGEN has the combined capabilities of GENENG and GENENG 2 for calculating steady state performance; to these the further capability for calculating transient performance was added. The DYNGEN can be used to analyze one- and two-spool turbojet engines or two- and three-spool turbofan engines without modification to the basic program. A modified Euler method is used by DYNGEN to solve the differential equations which model the dynamics of the engine. This new method frees the programmer from having to minimize the number of equations which require iterative solution. As a result, some of the approximations normally used in transient engine simulations can be eliminated. This tends to produce better agreement when answers are compared with those from purely steady state simulations. The modified Euler method also permits the user to specify large time steps (about 0.10 sec) to be used in the solution of the differential equations. This saves computer execution time when long transients are run. Examples of the use of the program are included, and program results are compared with those from an existing hybrid-computer simulation of a two-spool turbofan.

Sellers, J. F.↗

Tests of a mixed compression axisymmetric inlet with large transonic mass flow at Mach numbers 0.6 to 2.65

A 38.8-cm (15.28-in.) capture diameter model of a mixed-compression axisymmetric inlet system with a translating cowl was designed and tested. The internal contours, designed for Mach number 2.65, provided a throat area of 59 percent of the capture area when the cowl was retracted for transonic operation. Other model features included a boundary-layer removal system, vortex generators, an engine airflow bypass system, cowl support struts, and rotating rakes at the engine face. All tunnel testing was conducted at a tunnel total pressure of about 1 atm (a unit Reynolds number of about 8.53 million/m at Mach number 2.65) at angles of attack from 0 deg to 4 deg. Results for the following were obtained: total-pressure recovery and distortion at the engine face as a function of bleed mass-flow ratio, the effect of bleed and vortex generator configurations on pressure recovery and distortion, inlet tolerance to unstart due to changes in angle of attack or Mach number, surface pressure distributions, boundary-layer profiles, and transonic additive drag. At Mach number 2.65 and with the best bleed configurations, maximum total pressure recovery at the engine face ranged from 91 to 94.5 percent with bleed mass-flow ratios from 4 to 9 percent, respectively, and total-pressure distortion was less than 10 percent. At off-design supersonic Mach numbers above 1.70, maximum total-pressure recoveries and corresponding bleed mass flows were about the same as at Mach number 2.65, with about 10 to 15 percent distortion. In the transonic Mach number range, total pressure recovery was high (above 96 percent) and distortion was low (less than 15 percent) only when the inlet mass-flow ration was reduced 0.02 to 0.06 from the maximum theoretical value (0.590 at Mach number 1.0).

Smeltzer, D. B.↗

Advanced Low NO Sub X Combustors for Supersonic High-Altitude Aircraft Gas Turbines

A test rig program was conducted with the objective of evaluating and minimizing the exhaust emissions, in particular NO sub x, of three advanced aircraft combustor concepts at a simulated, high altitude cruise condition. The three combustor designs, all members of the lean reaction, premixed family, are the Jet Induced Circulation (JIC) combustor, the Vortex Air Blast (VAB) combustor, and a catalytic combustor. They were rig tested in the form of reverse flow can combustors in the 0.127 m. (5.0 in.) size range. Various configuration modifications were applied to each of the initial JIC and VAB combustor model designs in an effort to reduce the emissions levels. The VAB combustor demonstrated a NO sub x level of 1.1 gm NO2/kg fuel with essentially 100% combustion efficiency at the simulated cruise combustor condition of 50.7 N/sq cm (5 atm), 833 K (1500 R) inlet pressure and temperature respectively and 1778 K (3200 R) outlet temperature on Jet-A1 fuel. Early tests on the catalytic combustor were unsuccessful due to a catalyst deposition problem and were discontinued in favor of the JIC and VAB tests. In addition emissions data were obtained on the JIC and VAB combustors at low combustor inlet pressure and temperatures that indicate the potential performance at engine off-design conditions.

Roberts, P. B.↗

Study of two axisymmetric inlets designed for Mach 3.5

Results from wind-tunnel tests of two large-scale models of axisymmetric mixed-compression inlet systems designed for Mach number 3.5 are compared. One inlet incorporated a 'traveling'-bleed system in an effort to achieve maximum transonic engine airflow supply. The other inlet required only a 'fixed'-bleed system, but had 21 percent less transonic airflow supply. The inlet with fixed bleed appears more attractive, if auxiliary airflow systems are used to increase the transonic airflow supply, because it can be 45 percent shorter and would be considerably lighter than the traveling-bleed inlet. In addition, the fixed-bleed inlet offers more operating-control margin at supersonic Mach numbers when the inlet is started. Further, its off-design performance is higher because separation of the flow in the subsonic diffuser can be avoided - something that apparently cannot be done with a traveling-bleed inlet without reducing the transonic airflow supply. Finally, it appears that the management and efficiency of bleed airflow for the fixed-bleed inlet can be improved using analytical methods verified by the tests.

Sorensen, N. E.↗

Advanced low NO/x/ combustors for supersonic high-altitude aircraft gas turbines

A test rig program was conducted with the objective of evaluating and minimizing the exhaust emissions, in particular NO(x), of two advanced aircraft combustor concepts at a simulated, high-altitude cruise condition. The two combustor designs, both members of the lean-reaction, pre-mixed family, are known as the Jet Induced Circulation (JIC) combustor and the Vortex Air Blast (VAB) combustor and were rig tested in the form of reverse flow can combustors in the 0.127-m size range. Various configuration modifications were applied to each of the initial JIC and VAB combustor model designs in an effort to reduce the emissions levels. The VAB combustor demonstrated a NO(x) level of 1.1 gm NO2/kg fuel with essentially 100 percent combustion efficiency at the simulated cruise combustor condition of 507 kPa, 833 K inlet pressure and temperature, respectively and 1778 K outlet temperature on Jet-A1 fuel. In addition, emissions data were obtained at low combustor inlet pressure and temperatures that indicate the potential performance at engine off-design conditions.

Roberts, P. B.↗