Experimental characterization and analysis of phase change material-based thermal energy storage system for refrigerated display case

Refrigerated display cases that are used to store and exhibit food products in supermarkets and retail spaces consume a significant portion of the buildings’ total electricity. Importantly, the refrigeration-related energy cost and demand charges are greatly affected by the time-of-use electricity pricing and demand rates, which are at their maximum during peak hours, typically when refrigeration energy consumption is also high. Using energy storage to shift the refrigeration load from peak to off-peak hours can greatly reduce the operational costs in the supermarket. This study demonstrates a phase change material-based thermal energy storage (TES) system, specifically designed in stackable units, that can be integrated with an open vertical refrigerated display case. We perform numerical and experimental characterization that includes finite-difference modeling for the TES, prototype fabrication, and laboratory evaluation, followed by a preliminary system-level analysis to predict the impact of TES on the refrigerated case performance, energy use, and energy cost. The results show that the dedicated latent TES for refrigerated cases can provide a specific energy of 50.4 Wh/kg and a specific power of 15.5 W/kg. The TES can be charged during 12 h of the off-peak period and discharged at various rates during 4 to 6 h of the peak period, thereby shifting the refrigeration load from the peak to the off-peak period. Consequently, annual cost savings up to 19% can be achieved, depending on the thermal load, the summer/winter peak electricity pricing, and the transition temperature of the phase change material used.

25 ENERGY STORAGE↗

GSE Yearly Load Profiles for Each Airport Under Six Charging Scenarios

This dataset contains GSE yearly load profiles for each airport under six charging scenarios: (1) charging when the battery state of charge is insufficient for the next service using 40-kW chargers (S1); (2) charging when the battery state of charge is insufficient for the next service using 20-kW chargers (S2); (3) charging starts immediately after each GSE completes a service task using 40-kW chargers (S3); (4) charging starts immediately after each GSE completes a service task using 20-kW chargers (S4); (5) charging during off-peak hours using 40-kW chargers (S5); and (6) charging during off-peak hours using 20-kW chargers (S6). ![image](gse_load_profile_sample_day.png) GSE load profile of a sample day across different airport categories under charging scenario 1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Charger Requirements for GSE at Each Airport

This dataset contains the required number of chargers for GSE at each airport under six charging scenarios: (1) charging when the battery state of charge is insufficient for the next service using 40-kW chargers (S1); (2) charging when the battery state of charge is insufficient for the next service using 20-kW chargers (S2); (3) charging starts immediately after each GSE completes a service task using 40-kW chargers (S3); (4) charging starts immediately after each GSE completes a service task using 20-kW chargers (S4); (5) charging during off-peak hours using 40-kW chargers (S5); and (6) charging during off-peak hours using 20-kW chargers (S6).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fleet Size Requirements for Each GSE Type at Each Airport

This dataset contains the required number of vehicles for each GSE type at each airport under six charging scenarios: (1) charging when the battery state of charge is insufficient for the next service using 40-kW chargers (S1); (2) charging when the battery state of charge is insufficient for the next service using 20-kW chargers (S2); (3) charging starts immediately after each GSE completes a service task using 40-kW chargers (S3); (4) charging starts immediately after each GSE completes a service task using 20-kW chargers (S4); (5) charging during off-peak hours using 40-kW chargers (S5); and (6) charging during off-peak hours using 20-kW chargers (S6). ![image](gse-vehicles-chargers.png) Number of GSE vehicles per GSE type and chargers required for different airport categories under charging scenario 1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Communications Reliability for Vehicle Grid Integration

Electric Vehicles (EVs) adoption rate has been steadily increasing in the US leading to a growing number of charging stations including faster DC (Direct Current) chargers and slower Level 1 and Level 2 AC (Alternating Current) chargers. This increase in demand for electricity is further exacerbated by recent developments in Artificial Intelligence (AI) technology, advanced manufacturing, and digitization. These factors will require electric utilities to upgrade their infrastructure to keep up with the increasing electrical demand (especially during peak hours). An easy way to counteract the need for these upgrades is to shift a major chunk of active charge sessions (durations where there is energy transfer from charger to EV's propulsion battery) to off-peak hours thereby flattening the load curve and making the infrastructure more resilient. This concept is known as Smart Charge Management (SCM). EV owners also benefit from SCM since it lowers their charging costs and consequently their transportation costs by prioritizing charging during off-peak hours. SCM takes advantage of EV's capability to act as a controllable load or DER (Distributed Energy Resource). This report summarizes the reliability analysis performed on the communication required for two of these SCM use-cases. This analysis only focuses on SCM strategies for unidirectional charging (energy transfer from EVSE to EV or V1G) and not bidirectional charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Benefit-cost evaluation of an intra-regional air service in the Bay area

Utilization of an iterative statistical model is presented to evaluate combinations of commuter airport sites and surface transportation facilities in confunction with service by a given commuter aircraft type in light of Bay Area regional growth alternatives and peak and off-peak regional travel patterns. The model evaluates such transportation options with respect to criteria of airline profitability, public acceptance, and public and private nonuser costs. It incorporates information modal split, peak and off-peak use of the air commuter fleet, terminal and airport cost, development costs and uses of land in proximity to the airport sites, regional population shifts, and induced zonal shifts in travel demand. The model is multimodal in its analytical capability, and performs exhaustive sensitivity analysis.

Haefner, L. E.↗

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]↗

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗

Advanced blade-shaped thermal energy storage device: Development and application

Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.

Blade-shaped↗

Joint Optimization of Multimodal Transit Frequency and Shared Autonomous Vehicle Fleet Size with Hybrid Metaheuristic and Nonlinear Programming

Shared autonomous vehicles (SAVs) bring competition to traditional transit services but redesigning multimodal transit network can utilize SAVs as feeders to enhance service efficiency and coverage. This paper presents an optimization framework for the joint multimodal transit frequency and SAV fleet size problem, a variant of the transit network frequency setting problem. The objective is to maximize total transit ridership (including SAV-fed trips and subtracting boarding rejections) across multiple time periods under budget constraints, considering endogenous mode choice (transit, point-to-point SAVs, driving) and route selection, while allowing for strategic route removal by setting frequencies to zero. Due to the problem’s non-linear, non-convex nature and the computational challenges of large-scale networks, we develop a hybrid solution approach that combines a metaheuristic approach (particle swarm optimization) with nonlinear programming for local solution refinement. To ensure computational tractability, the framework integrates analytical approximation models for SAV waiting times based on fleet utilization, multimodal network assignment for route choice, and multinomial logit mode choice behavior, bypassing the need for computationally intensive simulations within the main optimization loop. Applied to the Chicago metropolitan area’s multimodal network, our method illustrates a 33.3% increase in transit ridership through optimized transit route frequencies and SAV integration, particularly enhancing off-peak service accessibility and strategically reallocating resources.

Ng, Max↗

Load-Shifting Strategies for Cost-Effective Emission Reductions at Wastewater Facilities

Significant hourly variation in the carbon intensity of electricity supplied to wastewater facilities introduces an opportunity to lower emissions by shifting the timing of their energy demand. This shift could be accomplished by storing wastewater, biogas from sludge digestion, or electricity from on-site biogas generation. However, the life cycle emissions and cost implications of these options are not clear. Here, we present a multiobjective optimization framework for comparing cost- and emission-minimizing load-shifting strategies at a California case study facility with a relatively low carbon intensity grid and high spread in peak and off-peak electricity prices. We evaluate cost and emission trade-offs from the optimal flexible operation of both existing infrastructure and optimally sized energy flexibility upgrades. We estimate energy-related emission reductions of up to 9.0% with flexible operation of existing infrastructure and up to 16.8% with optimally sized storage upgrades. Only a fraction of these potential savings are realized under actual industrial energy tariffs and the EPA’s recommended social cost of carbon. Energy flexibility may hold promise as a short-term emission-saving solution for the wastewater sector, but the extent of savings is heavily dependent on the cost of carbon, electricity tariffs, and emission intensity of the regional electricity grid.

climate↗

Techno-Economic Analysis for the Addition of a Thermal Energy Storage System to a Central Plant

Increasing energy demand and rising peak loads present significant challenges for energy management in commercial and institutional settings. As climate change drives greater cooling needs, central plants must navigate the complex tradeoffs between operational efficiency, cost control, and grid stability. Thermal energy storage (TES) systems offer a viable solution by shifting energy consumption from peak to off-peak periods, thereby reducing peak demand, lowering utility expenses, and improving grid resilience. However, the success of TES implementation hinges on appropriate system sizing, effective control strategies, and alignment with local utility rate structures. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills. Drawing on historical load profiles and utility tariffs, we assess three TES sizing approaches and their corresponding control strategies from both energy and economic perspectives. This article utilizes a model-based approach to assess the impact of TES sizing and control strategies on the techno-economic feasibility of integrating TES into an existing central plant. The models employed for this analysis were calibrated using 4 years of historical data. Here, the results demonstrated that utility tariffs and the campus's operational profiles dictate the most feasible sizing and control methods. The findings offer valuable insights for institutions and commercial building managers exploring sustainable energy solutions. By demonstrating how optimized TES strategies can improve operational efficiency while achieving financial savings, this study highlights the potential for TES to align performance with cost effectiveness in real-world applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

Advancing Grid Resilience through Smart Charge Management: Findings from Maryland’s Pilot

This report presents research findings from a four-year Smart Charge Management (SCM) pilot program conducted by Maryland’s largest electric utilities—Baltimore Gas and Electric (BGE), Potomac Electric Power Company (Pepco), and Delmarva Power & Light (DPL)—to evaluate strategies for optimizing electric vehicle (EV) charging loads and enhancing grid stability. Supported by the U.S. Department of Energy (DOE), Argonne National Laboratory collaborated with all project partners and examined the effectiveness of Time-of-Use (TOU) and Load Balancing (LB) strategies in managing peak demand, deferring costly infrastructure upgrades, and reducing grid constraints at the feeder level. Using charging data from over 4,600 EV drivers, the study analyzed SCM’s impact on the distribution systems of BGE and Pepco, which consists of over 2000 feeders. Unlike prior research that focused on system-wide trends or synthetic feeders, this analysis offers granular, feeder-level insights based on real-world operational data. It highlights how transformer density, load profiles, and infrastructure constraints influence smart charging performance. Results show feeder-level conditions play a crucial role in SCM effectiveness, with most feeders benefiting more from LB, while TOU-based SCM may be sufficient for others. By 2035, LB reduced peak charging loads by 27% on average, compared to 23% under TOU-based SCM, though some feeders saw reductions exceeding 35%, while others experienced minimal impact. Feeders with higher transformer utilization and limited capacity benefited more from LB, which more effectively distributed charging demand during off-peak hours. Beyond reducing grid constraints, SCM offers long-term operational and financial benefits. By shifting EV charging demand strategically, utilities can optimize asset utilization, delay infrastructure investments, and enhance grid performance. In terms of infrastructure upgrade deferrals, at the feeder level, LB consistently reduced peak charging loads and resulting infrastructure upgrade costs, particularly in high EV enrollment areas, decreasing the number of overloaded transformers by up to 35%, while TOU-based SCM achieved 20-30% reductions depending on feeder characteristics. At the system level, LB has the potential to defer total upgrade costs by $\$$186 million for BGE, compared to $\$$159 million under TOU-based SCM. For Pepco, TOU-based SCM performed slightly better, deferring upgrade costs by $\$$30 million, compared to $\$$29 million under LB. Section 4.5 reviews some of the system differences between BGE and Pepco. However, as EV adoption scales, TOU-based SCM will introduce secondary peak charging loads, reinforcing the need for more advanced, adaptive SCM approaches to prevent new grid challenges. As EV adoption continues to grow, feeder-level managed charging strategies will be essential for mitigating grid stress, improving infrastructure efficiency, and maintaining energy affordability for consumers. This report provides critical insights for utilities, Public Utility Commissions (PUCs), and state agencies on the role of feeder-specific smart charging in infrastructure planning, policy development, and grid modernization. The findings underscore the importance of tailored, data-driven SCM solutions that align with local grid conditions, ensuring a resilient, cost-effective transition to increasing EV adoption while safeguarding distribution system performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Characterization of InCharge™ ICE-66 V2X Bidirectional DC Fast Charger

Vehicle-to-grid (V2G) technology extends the role of Plug-in Hybrid Vehicle’s (PHEV) and Battery Electric Vehicle’s (BEV) batteries beyond transportation by enabling bidirectional power transfer between the vehicle's onboard energy storage and the utility grid. Modern battery-powered vehicles are equipped with high-capacity battery packs that remain stationary and underutilized for the majority of their operational life. A vehicle used for daily commuting may be parked and connected to charging infrastructure for 18–20 hours per day, representing a significant untapped energy resource. When considered at scale, the aggregated storage capacity of a modest fleet of 10–15 vehicles within a single parking facility can reach the MWh range, sufficient to partially offset peak demand for a mid-size commercial building or contribute meaningful ancillary services to the local grid. The ability to charge during off-peak periods when electricity prices are low and discharge during peak demand when prices are high positions EV batteries as distributed energy arbitrage assets, with the potential to offset vehicle ownership and charging costs. Beyond energy arbitrage, V2G-capable assets can provide ancillary grid services through active and reactive power injections. Active power supports grid frequency regulation, while reactive power supports local voltage regulation. Together, these capabilities establish V2G as a technically promising and economically relevant pathway toward greater integration of battery-powered vehicles into the broader energy system.

33 ADVANCED PROPULSION SYSTEMS↗