Saffire Offgas Testing Strategy, International Offgas Round Robin Status & Results
No abstract available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract available
A better understanding of the decomposition process in the DWPF melter is desired to improve the melter offgas flammability model. Antifoam in DWPF is of interest because its presence contributes to the flammability of the melter offgas via formation of flammable gas species. Simulant formic/nitric and glycolic/nitric flowsheet SRAT/SME (melter feed) products were studied at several antifoam concentrations. In addition, redox measurements were compared to the offgas generation data to aid in the overall understanding of the feed decomposition process in the DWPF. A new method for quantitatively measuring the offgas species from simulated DWPF melter feed during heating was used to measure the offgas as a function of temperature. Results indicated that the form of the antifoam (degraded, pristine, or a surrogate) had a negligible effect on the offgas composition (including H 2 generation) or glass redox for the SB8 formic/nitric flowsheet. Antifoam concentration in the glycolic/nitric flowsheet feed had a negligible effect on the offgas composition (including H 2 generation) and glass redox. The glycolic/nitric flowsheet feed had significantly less (~ ¼) total H 2 generation in the offgas during melting compared to the formic/nitric flowsheet and is thought to be related to different reaction paths among the flowsheets.
The overall objective of this calculation is to develop design basis flowsheets for confirmation of equipment and piping design associated with the LAW melter offgas system (Systems LOP and LVP). Three flowsheet cases are developed. Minimum, maximum, and nominal offgas cases are developed assuming two melters in operation. The minimum, maximum, and nominal cases are expected during normal operation of the offgas system. An additional minimum case is developed assuming one melter is operating.
NASA has accumulated considerable experience in offgas testing of whole modules prior to their docking with the International Space Station (ISS). Since 1998, the Space Toxicology Office has performed offgas testing of the Lab module, both MPLM modules, US Airlock, Node 1, Node 2, Node 3, ATV1, HTV1, and three commercial vehicles. The goal of these tests is twofold: first, to protect the crew from adverse health effects of accumulated volatile pollutants when they first enter the module on orbit, and secondly, to determine the additional pollutant load that the ISS air revitalization systems must handle. In order to predict the amount of accumulated pollutants, the module is sealed for at least 1/5th the worst‐case time interval that could occur between the last clean air purge and final hatch closure on the ground and the crew's first entry on orbit. This time can range from a few days to a few months. Typically, triplicate samples are taken at pre‐planned times throughout the test. Samples are then analyzed by gas chromatography and mass spectrometry, and the rate of accumulation of pollutants is then extrapolated over time. The analytical values are indexed against 7‐day spacecraft maximum allowable concentrations (SMACs) to provide a prediction of the total toxicity value (T‐value) at the time of first entry. This T‐value and the toxicological effects of specific pollutants that contribute most to the overall toxicity are then used to guide first entry operations. Finally, results are compared to first entry samples collected on orbit to determine the predictive ability of the ground‐based offgas test.
Approximately 56 million gallons of nuclear waste are currently stored in 177 underground storage tanks at the Hanford site in Washington state. A portion of the tank waste is targeted for immobilization by converting the nuclear waste to borosilicate glass through a process called vitrification. During vitrification, emissions are produced in addition to the intended glass product. These emissions, contained in a volume above the molten glass called the plenum, are composed of water vapor, air components, aerosols, particulates, and other gaseous species that result from evaporation, reactions, and air influx. The formation of these gasses causes the surface of the glass to foam. To reduce foaming, sucrose is added to the waste stream before the conversion to glass. Sucrose also reduces the formation of hazardous gasses in the plenum including nitrous oxides, NOx, and carboxides, COx. However, if excess sucrose is present, the reactions that produce the gasses in the plenum will be incomplete, and increased levels of NOx and COx can be observed. The Waste Treatment and Immobilization Plant at the Hanford site is equipped with the technology to treat the plenum emissions. Though many tests have been run to determine the presence of particulates in the plenum emissions, there is does not exist an established method to confidently predict the composition of the gaseous species in the plenum prior to treatment without physical testing. A model was created in the process modeling software Aspen Plus to predict the composition of NOx and COx in the plenum. The model employs a constant stirred tank reactor and user-defined reaction chemistry to determine the plenum composition. To verify the model, the offgas predicted by the model were compared to available offgas data for ten different feed compositions. It is demonstrated that the developed Aspen Plus model is capable of predicting the composition of NOx and COx in the plenum.
This report describes the development and in facility demonstration of a Raman spectrometer to monitor known aluminum offgas components generated during the dissolution of Spent Nuclear Fuel at the Savannah River Site H-Canyon facility. The presence of these gases is an indicator that material is actively being dissolved. This process monitoring technique, which measures the offgas in real time, has the potential to improve the efficiency of facility operations. If the dissolution time is too short, time is wasted due to extended dissolution periods with additional probing of the dissolver pot to confirm that fragment levels are below the thresholds for continuing to the next charge or moving the dissolvent to a receiving tank. If the dissolution time is too long, time and energy are wasted.
NASA-STD-6001B states "all nonmetals tested in accordance with NASA-STD-6001 should be retested every 10 years or as required by the responsible program/project." The retesting of materials helps ensure the most accurate data are used in material selection. Manufacturer formulas and processes can change over time, sometimes without an update to product number and material information. Material performance in certain NASA-STD-6001 tests can be particularly vulnerable to these changes, such as material offgas (Test 7). In addition, Test 7 analysis techniques at NASA White Sands Test Facility were dramatically enhanced in the early 1990s, resulting in improved detection capabilities. Low level formaldehyde identification was improved again in 2004. Understanding the limitations in offgas analysis data prior to 1990 puts into question the validity and current applicability of that data. Case studies on Super Koropon (Registered trademark) and Aeroglaze (Registered trademark) topcoat highlight the importance of material retesting.
This system design description (SDD) defines the technical, functional, and performance requirements of the Low-Activity Waste (LAW) Facility primary offgas process system (LOP) and the LAW Facility secondary offgas/vessel vent process system (LVP). This document details waste treatment requirements, environmental compliance requirements, and authorization basis requirements of the LOP and LVP systems as they are currently known and understood.
Between 7 April and 11 April 2012 a chemist from the JSC Toxicology Group acquired samples of air in 500 ml evacuated canisters from the sealed Dragon Module at the Space-X facility at KSC. Three samples were taken of facility air (two before the test and one after the test), and a total of 9 samples were taken from the sealed module in triplicate at the following times: 0 hours, 48 hours, and 96 hours. The module contained 470 kg, which was 100% of the mass to be launched. Analytical data contained in the Toxicology Group Report (attached) show that the ambient facility air was clean except for almost 9 milligrams per cubic meter of isopropanol (IPA) in the sample taken at the end of the test. Space-X must ensure that IPA is not introduced into the module before it is sealed for launch. Other minor contaminants in the ambient air included the following: perfluoro(2-methyl)pentane and hexamethylcyclotrisiloxane. The first-acquired samples of each triplicate from the module were not analyzed. Analyses of pairs of samples that were taken during the test show excellent agreement between the pairs and a linear increase in the T-values during the 4 days of the test (figure below). The rate of increase averaged 0.124 T units per day. If the time from last purge of the module on the ground to crew first entry on orbit is 10 days, then the T value at first entry should be less than 1.2 units, which is well below the criterion of 3.0 for consideration of additional protection of the crew from offgas products. The primary contributors were as follows: trimethylsilanol (0.057), fluorotrimethylsilane (0.047), acetaldehyde (0.004), hexamethylcyclopentasiloxane (0.003), and toluene (0.002).
The Pacific Northwest National Laboratory (PNNL) was tasked to perform Raman spectroscopy and laser induced breakdown spectroscopy (LIBS) testing on the melter off-gas condensate generated during low-activity waste process testing of a sample from Hanford Site tank AP-105 and/or evaporate from evaporation of the condensate. This was a proof-of-principle demonstration that Raman spectroscopy and LIBS have the potential to be used as analytical tools for in-line process analysis of key aqueous phase analytes in radioactive process streams associated with the Hanford Waste Treatment and Immobilization Plant. The work completed under this project complements work completed for WRPS with the development of in-line monitoring systems to characterize and quantify constituents of tank waste following Cs removal and filtration. The WRPS work is currently limited to Raman sensors and utilizes chemometric models for quantification of several anionic species in the sample system. It should be noted that while this approach can be applied to off-gas condensate streams, new chemometric models are needed to accurately quantify analytes under off-gas condensate conditions. The work completed under this project makes timely use of available samples and equipment at PNNL. The project utilized the opportunity to collect off-gas samples from planned AP-105 processing work and included the direct condensate and the evaporate from the DFLAW Radioactive Waste Test Platform. Samples were characterized by instruments already in place at PNNL including a Raman spectrometer optimized for in-line monitoring of flowing and stationary samples as well as a LIBS instrument, which was optimized for static liquid droplet analysis. The ultimate objective was to determine if these techniques could be used to qualitatively characterize analytes present within the off-gas samples. The testing confirmed the use of the Raman as an in-line monitoring system was able to qualitatively observe NO 3 - , NO 2 - , aluminum (as aluminate, Al(OH) 4 - ), SO 4 2- , CrO 4 2- , CO 3 2- , and PO 4 3- in the AP-105 melter feed evaporator condensate samples. The testing also confirmed LIBS as a potential useful technique for in-line monitoring, able to qualitatively detect Na, N, Al, and tentatively Cr and Cl in a simulant stock evaporate solution.
Savannah River Remediation (SRR) tasked Savannah River National Laboratory (SRNL) to examine glycolate destruction in radioactive samples emulating the proposed process. Experiments with radioactive Defense Waste Processing Facility (DWPF) condensates were performed to demonstrate the oxidation of glycolate using sodium permanganate. One test each was performed for Off-Gas Condensate Tank (OGCT) and Slurry Mix Evaporator Condensate Tank (SMECT) samples received. Condensates were blended with Recycle Collection Tank (RCT) heel simulant and Slurry Mix Evaporator (SME) product containing glycolate to represent typical RCT compositions with estimated nominal entrainment of glycolate. A permanganate to glycolate (P/G) molar ratio targeting 5.7 decreased sample glycolate concentration below Ion Chromatography (IC), glycolate method reporting limits in less than 2 hours for the OGCT sample and in less than 8 hours for the SMECT sample.
The project goal is to study adsorbent materials and adsorption conditions in order to develop recommendations to improve the current BWR off-gas treatment operations with respect to cost savings. ANL tasks included a literature survey on relevant information for the adsorption of radionuclides (e.g., Xe and Kr), including adsorption coefficients on various charcoals, the effect of radionuclide concentration and moisture, and alternative sorption materials; participate in meetings and teleconferences as needed; prepare reports and support efforts INL and other organization Team Members.
This presentation provides flowrate and compositional information on process off gas generated from a Hydrothermal Liquefaction test conducted with sludge. Density and viscosity data as a function of temperature on biocrude properties from this test are also provided. Data can be used for comparisons, preliminary estimates, modeling and as preliminary data for stakeholders
On September 26 and September 28,2012 a chemist from the JSC Toxicology Group acquired samples of air in 500 m1 evacuated canisters from the sealed Space-Xl Dragon Module. One sample was also acquired from Space-X Facility near the module at the start of the test. Samples of the module air were taken in triplicate once the module had been sealed, and then taken again in triplicate 1.98 days later. Ofthe triplicate samples, the first served as a line purge, and the last two were analyzed. The results of 5 samples are reported.
The Defense Waste Processing Facility has experienced significant issues with the stripping and recovery of mercury in the Chemical Processing Cell (CPC). The stripping rate has been inconsistent, often resulting in extended processing times to remove mercury to the required endpoint concentration. The recovery of mercury in the Mercury Water Wash Tank has never been high, and has decreased significantly since the Mercury Water Wash Tank was replaced after the seventh batch of Sludge Batch 5. Since this time, essentially no recovery of mercury has been seen. Pertinent literature was reviewed, previous lab-scale data on mercury stripping and recovery was examined, and new lab-scale CPC Sludge Receipt and Adjustment Tank (SRAT) runs were conducted. For previous lab-scale data, many of the runs with sufficient mercury recovery data were examined to determine what factors affect the stripping and recovery of mercury and to improve closure of the mercury material balance. Ten new lab-scale SRAT runs (HG runs) were performed to examine the effects of acid stoichiometry, sludge solids concentration, antifoam concentration, form of mercury added to simulant, presence of a SRAT heel, operation of the SRAT condenser at higher than prototypic temperature, varying noble metals from none to very high concentrations, and higher agitation rate. Data from simulant runs from SB6, SB7a, glycolic/formic, and the HG tests showed that a significant amount of Hg metal was found on the vessel bottom at the end of tests. Material balance closure improved from 12-71% to 48-93% when this segregated Hg was considered. The amount of Hg segregated as elemental Hg on the vessel bottom was 4-77% of the amount added. The highest recovery of mercury in the offgas system generally correlated with the highest retention of Hg in the slurry. Low retention in the slurry (high segregation on the vessel bottom) resulted in low recovery in the offgas system. High agitation rates appear to result in lower retention of mercury in the slurry. Both recovery of mercury in the offgas system and removal (segregation + recovery) from the slurry correlate with slurry consistency. Higher slurry consistency results in better retention of Hg in the slurry (less segregation) and better recovery in the offgas system, but the relationships of recovery and retention with consistency are sludge dependent. Some correlation with slurry yield stress and acid stoichiometry was also found. Better retention of mercury in the slurry results in better recovery in the offgas system because the mercury in the slurry is stripped more easily than the segregated mercury at the bottom of the vessel. Although better retention gives better recovery, the time to reach a particular slurry mercury content (wt%) is longer than if the retention is poorer because the segregation is faster. The segregation of mercury is generally a faster process than stripping. The stripping factor (mass of water evaporated per mass of mercury stripped) of mercury at the start of boiling were found to be less than 1000 compared to the assumed design basis value of 750 (the theoretical factor is 250). However, within two hours, this value increased to at least 2000 lb water per lb Hg. For runs with higher mercury recovery in the offgas system, the stripping factor remained around 2000, but runs with low recovery had stripping factors of 4000 to 40,000. DWPF data shows similar trends with the stripping factor value increasing during boiling. These high values correspond to high segregation and low retention of mercury in the sludge. The stripping factor for a pure Hg metal bead in water was found to be about 10,000 lb/lb. About 10-36% of the total Hg evaporated in a SRAT cycle was refluxed back to the SRAT during formic acid addition and boiling. Mercury is dissolved as a result of nitric acid formation from absorption of NO x . The actual solubility of dissolved mercury in the acidic condensate is about 100 times higher than the actual concentrations measured. Mercury metal present in the MWWT from previous batches could be dissolved by this acidic condensate. The test of the effect of higher SRAT condenser temperature on recovery of mercury in the MWWT and offgas system was inconclusive. The recovery at higher temperature was lower than several low temperature runs, but about the same as other runs. Factors other than temperature appear to affect the mercury recovery. The presence of chloride and iodide in simulants resulted in the formation of mercurous chloride and mercurous iodide, respectively, in the offgas system. Actual waste data shows that the chloride content is much less than the simulant concentrations. Future simulant tests should minimize the addition of chloride. Similarly, iodine addition should be eliminated unless actual waste analyses show it to be present; currently, total iodine is not measured on actual waste samples.
The H-Canyon facility will be used to dissolve Pu metal for subsequent purification and conversion to plutonium dioxide (PuO 2 ) using Phase II of HB-Line. To support the new mission, the development of a Pu metal dissolution flowsheet which utilizes concentrated (8-10 M) nitric acid (HNO 3 ) solutions containing potassium fluoride (KF) is required. Dissolution of Pu metal in concentrated HNO 3 is desired to eliminate the need to adjust the solution acidity prior to purification by anion exchange. The preferred flowsheet would use 8-10 M HNO 3 , 0.015-0.07 M KF, and 0.5-1.0 g/L Gd to dissolve the Pu up to 6.75 g/L. An alternate flowsheet would use 8-10 M HNO 3 , 0.05-0.2 M KF, and 1-2 g/L B to dissolve the Pu. The targeted average Pu metal dissolution rate is 20 mg/min-cm 2 , which is sufficient to dissolve a “standard” 2250-g Pu metal button in 24 h. Plutonium metal dissolution rate measurements showed that if Gd is used as the nuclear poison, the optimum dissolution conditions occur in 10 M HNO 3 , 0.04-0.05 M KF, and 0.5-1.0 g/L Gd at 112 to 116 °C (boiling). These conditions will result in an estimated Pu metal dissolution rate of ~11-15 mg/min-cm 2 and will result in dissolution times of 36-48 h for standard buttons. The recommended minimum and maximum KF concentrations are 0.03 M and 0.07 M, respectively. The data also indicate that lower KF concentrations would yield dissolution rates for B comparable to those observed with Gd at the same HNO 3 concentration and dissolution temperature. To confirm that the optimal conditions identified by the dissolution rate measurements can be used to dissolve Pu metal up to 6.75 g/L in the presence of representative concentrations of Fe and Gd or B, a series of experiments was performed to demonstrate the flowsheets. In three of the five experiments, the offgas generation rate during the dissolution was measured and samples were analyzed for hydrogen gas (H 2 ). The use of 10 M HNO 3 containing 0.03-0.05 M KF, 0.5-1.0 g/L Gd, and 1.9 g/L Fe resulted in complete dissolution of the metal in 2.0-3.5 h. When B was used as the neutron poison, 10 M HNO 3 solutions containing 0.05-0.1 M KF, 1.9 g/L Fe, and 1 g/L B resulted in complete dissolution of the metal in 0.75-2.0 h. Dissolution rates estimated using data from the flowsheets demonstrations agreed reasonably well with the measured rates; although, a discrepancy was observed in the Gd system. The presence of 1 g/L Gd or B in the dissolving solution had about the same effect on the dissolution rate. The predominant Pu valence in the dissolving solution was Pu(IV). The concentration of Pu(VI) was evaluated by UV-visible spectroscopy and was estimated to be significantly less than 1 wt %. The offgas generation rates and H 2 concentrations measured in the offgas from experiments performed using 10 M HNO 3 containing 0.05 M KF, 1.9 g/L Fe and either 1 g/L Gd or B were approximately the same. These data support the conclusion that the presence of either 1 g/L Gd or B had the same general effect on the dissolution rate. The calculated offgas generation during the dissolutions was 0.6 mol offgas/mol of Pu. The H 2 concentration measured in the offgas from the dissolution using Gd as the neutron poison was approximately 0.5 vol %. In the B system, the H 2 ranged from nominally 0.8 to 1 vol % which is about the same as measured in the Gd system within the uncertainty of the analysis. The offgas generation rate for the dissolution performed using 10 M HNO 3 containing 0.03 M KF, 0.5 g/L Gd, and 1.9 g/L Fe was approximately a factor of two less than produced in the other dissolutions; however, the concentration of H 2 measured in the offgas was higher. The adjusted concentration ranged from 2.7 to 8.8 vol % as the dissolution proceeded. Higher concentrations of H 2 occur when the Pu dissolution proceeds by a metal/acid reaction rather than nitrate oxidation. The higher H 2 concentration could be attributed to the reduced activity of the fluoride due to complexation with Pu as the dissolution progressed. Dissolution of Pu metal at 20 °C in 10 M HNO 3 containing 0.05 M KF showed that the Pu metal dissolves slowly without any visible gas generation. As the Pu metal dissolves, it forms a more-dense Pu-bearing solution which sank to the bottom of the dissolution vessel. The dissolved Pu did not form a boundary layer around the sample and failed to distribute homogeneously due to minimal (thermally-induced) mixing. This indicates that in the H-Canyon dissolver insert, the Pu will diffuse out of the insert into the bulk dissolver solution where it will disperse. At 35 °C, the Pu metal dissolved without visible gas generation. However, due to thermal currents caused by maintaining the solution at 35 °C, the dissolved Pu distributed evenly throughout the dissolver solution. It did not form a boundary layer around the sample.