Search NASA⌕ Search

SEARCH · Search NASA

Results for “on-line”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

First on-line commissioning experiments at the St. Benedict facility

Nuclear beta decays provide an excellent probe of fundamental symmetries due to their mediation by the weak interaction. In particular, precise measurements of these decays provide constraints on the unitarity of the Cabbibo-Kobayashi-Maskawa (CKM) quark-mixing matrix. While superallowed pure Fermi decays currently set the most precise limits, the alternative suite of superallowed mixed mirror decays has been ill-studied. These nuclei can provide an important consistency check of calculation and measurement methods employed for the pure Fermi decays, more critically needed now in the wake of a 2.4σ deviation from unitarity of the CKM matrix. In order to remedy the gap in data for mirror decays, the Superallowed Transition Beta-Neutrino Decay Ion Coincidence Trap (St. Benedict) facility is being commissioned at the University of Notre Dame’s Nuclear Science Laboratory (NSL). In this paper, we present first results of the commissioning of the St. Benedict facility on-line at the TwinSol radioactive beam facility. The results of initial commissioning experiments involving the St. Benedict gas catcher, RF carpet, RFQ ion guide and RFQ cooler-buncher will be presented.

beta decay↗

A Novel Optical Instrument for On-Line Measurement of Particle Size Distribution—Application to Clean Coal Technologies

A flow cell is a critical measurement interface for many optical instruments. However, the flows are often sampled under harsh conditions, such as under high pressure and/or high temperature, in the presence of particles, moisture, vapors with high dew points or corrosive gases. Therefore, obtaining a high-optical-quality flow cell that does not perturb the measurement is a significant challenge. To address this challenge, we proposed a new flow cell that employs a unique laminar coaxial flow field (for the purge and sample flows). A test system was built to conduct particle size distribution (PSD) measurements with no sampling bias using a state-of-the-art analyzer (Malvern Panalytical Insitec). The results revealed that the measurement zone is well defined solely by the sample flow, and the optical windows are well protected by the purge flow, with minimal risk of any depositions from the sample flow. Using this flow cell, the Insitec can successfully measure PSD under high pressure and temperature under moist, corrosive conditions without generating any sampling bias. Importantly, we successfully applied this flow cell for on-line PSD measurement for the flue gas of a 100 kWth pressurized oxy-coal combustor operating at 15 bara.

Cheng, Mao (ORCID:0000000213273900)↗

Rapid monitoring of fermentations: a feasibility study on biological 2,3-butanediol production

2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be produced by the fermentation of sugars using an engineered strain of Zymomonas mobilis . These fermentations require continuous monitoring and modification of fermentation conditions to maximize 2,3-BDO yields and minimize the production of the undesired coproducts glycerol and acetoin. Because of the time required for sampling and off-line chromatographic measurement of fermentation samples, the ability of fermentation scientists to modify fermentation conditions in a timely manner is limited. The goal of this study was to test if near-infrared spectroscopy (NIRS) along with multivariate statistics could reduce the time needed for this analysis and enable real-time monitoring and control of the fermentation. In this work we developed partial least squares (PLS) calibration models to predict the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol in fermentations via NIRS using two different spectrometers and two different spectroscopy modalities. We first evaluated the feasibility of rapid NIRS monitoring through experiments where we measured the signals from each analyte of interest and built NIRS-based PLS models using spectra from synthetic samples containing uncorrelated concentrations of these analytes. All analytes showed unique spectral signatures, and this initial modeling showed that all analytes could be detected simultaneously. We then began work with samples from laboratory fermentation experiments and tested the feasibility of regression model development across two spectral collection modalities (at-line and on-line) and two instruments: a laboratory-grade instrument and a low-cost instrument with a more limited spectral range. All modalities showed promise in the ability to monitor Z. mobilis fermentations of glucose and xylose to 2,3-BDO. The low-cost instrument displayed a lower signal-to-noise ratio than the laboratory-grade instrument, which led to comparatively lower performance overall, but still provided sufficient accuracy to monitor fermentation trends. While the ease of use of on-line monitoring systems was favored as compared to at-line systems due to the lack of sampling required and potential for automated process control, we observed some decrease in performance due to the additional complexity of the sample matrix. We have demonstrated that NIRS combined with multivariate analysis can be used for at-line and on-line monitoring of the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol during Z. mobilis fermentations. The decrease in signal-to-noise ratio when using a low-cost spectrometer led to greater prediction error than the laboratory-grade spectrometer for at-line monitoring. The on-line monitoring modality showed great promise for real time process control via NIRS.

09 BIOMASS FUELS↗

Fluorescence Signatures of Rare Earth Metals during Precipitation in Various Conditions

Fluorescence spectroscopy is a widely used sensor methodology that analyzes light emitted from a compound or element as it decays from an excited state. This technique is very sensitive and selective, which is ideal to characterize analytes at lower limits of detection. Key example targets of significant industry and research interest include rare earth elements (REEs) such as dysprosium (Dy) and europium (Eu). These are widely used in advanced technologies including semiconductors, electric vehicle motors, lasers, and permanent magnets. Identifying new sources and responsible reutilization of REEs is essential, and new approaches to extract and recycle REEs could be notably enhanced through the integration of on-line sensors. The sensors can support faster process design, informed scale-up, and cost-effective deployment. This study covers the initial exploration of applying fluorescence-based on-line monitoring to REEs within a precipitation process. This study demonstrates the successful scale-up of a fluorescence -based sensing approach, from stationary cuvettes and small-volume microfluidic devices to continuous flow systems operating at the bench scale (10-25mL). This work also provides initial insight into the challenges of signal’s effects and utility within a turbid environment. Using a modular design for monitoring flowing solutions in a flow tube, fluorescence can be characterized for a variety of analytical targets. In this study, detection performance parameters between the cuvette and flow tube system were compared. Additionally, the response of Dy during precipitation by sodium bicarbonate in the two measurement designs was explored. This letter represents a starting point to bridge the gap between traditional fluorescence sensor measurements in a cuvette to future developments that explore the ability to integrate fluorescence sensors into extraction and separation processes at industrially relevant scales.

fluorescence↗

Autonomous power expert fault diagnostic system for Space Station Freedom electrical power system testbed

The goal of the Autonomous Power System (APS) program is to develop and apply intelligent problem solving and control to the Space Station Freedom Electrical Power System (SSF/EPS) testbed being developed and demonstrated at NASA Lewis Research Center. The objectives of the program are to establish artificial intelligence technology paths, to craft knowledge-based tools with advanced human-operator interfaces for power systems, and to interface and integrate knowledge-based systems with conventional controllers. The Autonomous Power EXpert (APEX) portion of the APS program will integrate a knowledge-based fault diagnostic system and a power resource planner-scheduler. Then APEX will interface on-line with the SSF/EPS testbed and its Power Management Controller (PMC). The key tasks include establishing knowledge bases for system diagnostics, fault detection and isolation analysis, on-line information accessing through PMC, enhanced data management, and multiple-level, object-oriented operator displays. The first prototype of the diagnostic expert system for fault detection and isolation has been developed. The knowledge bases and the rule-based model that were developed for the Power Distribution Control Unit subsystem of the SSF/EPS testbed are described. A corresponding troubleshooting technique is also described.

Truong, Long V.↗

Excited states in semi-magic 82 Ge populated in the βn-decay of 83 Ga

For this work, the βn and β-decay of the neutron-rich 83 Ga isotopes produced in proton-induced fission of 238 U were studied at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory using on-line mass separation and the hybrid-3Hen neutron-γ detector array. Excited states in semi-magic 82 Ge populated in βn decay of 83 Ga were identified using neutron-γ coincidences. The measured relative population of excited states in 82 Ge is compared with a βn emission model, where the neutron emission model combines the strength distribution obtained from the shell-model calculations with the statistical Hauser-Feshbach model.

3HEN↗

Multimodal In Situ Characterization Uncovers Unexpected Stability of a Cobalt Electrocatalyst for Acidic Sustainable Energy Technologies

An accelerated development of durable and affordable sustainable energy technologies is often hindered by a limited understanding of how non-precious materials within these systems degrade. In acidic proton exchange membrane fuel cells and water electrolyzers, metallic cobalt (Co) is considered an unstable component that is often combined with precious metals or other stabilizers. To understand the mechanisms behind Co instability, we employ an experimental platform that quantifies dissolution with on-line inductively coupled plasma mass spectrometry and product formation with electrochemical mass spectrometry during electrochemical testing, along with ex- situ characterization. Under varied conditions (electrocatalysis, time, gas-type saturation, and ion concentration), windows of Co stability are observed that are different than predicted with classical chemical thermodynamics, suggesting new stabilization and degradation mechanisms than previously understood. Notably, Co is active for the hydrogen evolution reaction (HER), with prolonged stability that is ~300 mV different than thermodynamically projected. Additionally, in an oxygenated environment, Co concurrently performs the HER and oxygen reduction reaction (ORR) yet undergoes different morphology changes and dissolution mechanisms. Interestingly, in the absence of electrocatalysis, there is a 22x decrease in dissolution in an oxygen-free environment, proposing a route to decrease Co losses during device shutdown protocols. Lastly, under more extreme operating conditions, Co becomes stable after a substantial amount of dissolution, suggesting that high concentrations of Co 2+ ions in the microenvironment induce the formation of a stable CoHO 2 surface. Altogether, these results can be leveraged to improve the design and development of more robust and cost-effective sustainable energy technologies, as well as promote strategic strategies for prolonged material utilization.

Dissolution↗

Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗

Customized Bayesian optimization for efficient beam tuning at the facility for rare isotope beams

Bayesian optimization (BO) has recently emerged as a powerful approach for on-line beam tuning, and it is rapidly gaining adoption across accelerator facilities due to its flexibility and efficiency in handling complex optimization tasks. At the Facility for Rare Isotope Beams, rapid and reliable tuning is essential to support the delivery of diverse ion species. To improve the practicality of BO in this setting, we implemented several enhancements, including scalarized composite objective construction for multicriteria optimization, asynchronous evaluation for better resource utilization, prior-mean-assisted optimization to accelerate convergence, and a local search strategy for rapid completion of the task. We present the details of these methods, discuss challenges-encountered, and share our experience applying them to specific beam-tuning tasks.

Accelerators & storage rings↗

Closing the loop: model-predictive control for a closed-circuit reverse osmosis system

This article presents a model-predictive controller (MPC) for the maximization of the energy efficiency of a closed-circuit desalination reverse osmosis (CCRO) system. CCRO is a process for producing drinking water that is based on a cyclic operation with the following two phases: (a) filtration and (b) drain. In this article, we test model predictive control for optimal control of this process. The most important features of our approach are as follows: (a) the selection of a model structure that enables reliable forecasts of the filtration phase (up to 3 h), (b) an on-line model calibration strategy that ensures model forecast reliability, and (c) the satisfaction of equipment safety and operational constraints on the selected setpoints. We challenge this through deliberate introduction of changes in the unmeasured feed concentration and the applied constraints. Our results indicate that frequent model parameter updates are critical to maintain model reliability for MPC purposes. In addition, we illustrate that parameter identifiability is not guaranteed and that deliberate variation in flow rates is necessary even though the process never operates in steady state. Finally, MPC can compute flow rate setpoints that maximize the energy efficiency of the CCRO process while satisfying the applicable equipment and safety constraints.

closed-circuit reverse osmosis↗

OpenCSP Step-by-Step: Getting Started Guide for Windows (V.1.0)

This document provides a step-by-step tutorial on how to set up OpenCSP for both users and developers. It is meant to support novice users and does not require software engineering experience. It is a detailed extension of the OpenCSP getting started on-line documentation, found here: https://opencsp.readthedocs.io/en/main/contributing.html#getting-started. For an overview of OpenCSP overall, see the OpenCSP website: https://opencsp.sandia.gov. For details on OpenCSP components and algorithm, see the references.

97 MATHEMATICS AND COMPUTING↗

Preliminary Plan to Inform Testing of a Heat Exchanger Test Article

This report presents a preliminary plan to guide the qualification testing of advanced heat exchanger (HX) components for nuclear-to-industrial heat transfer applications. The objective is to establish a defensible, physics-based methodology that integrates computational modeling, targeted experimentation, and in-service inspection considerations to demonstrate component performance and reliability under representative reactor conditions. The analysis identifies Sodium-cooled Fast Reactor (SFR) and High-Temperature Gas-cooled Reactor (HTGR) systems as reference configurations in terms of temperature, pressure, and chemical environment. Within these operating envelopes, dominant degradation mechanisms— including creep–fatigue interaction, flow-induced vibration, corrosion, and diffusion-bond deterioration—were evaluated to define test requirements. A comprehensive computationalexperimental framework is proposed to support life prediction and qualification activities. The framework couples high-fidelity structural-mechanics, thermal-hydraulic, and fluid-structure interaction models with accelerated degradation testing to produce a traceable linkage between microstructural evolution, mechanical performance, and remaining useful life (RUL). The approach adheres to established Verification, Validation, and Uncertainty Quantification (VVUQ) standards (ASME V&V 10/20; NUREG-2152) and incorporates a digital-twin architecture for continuous model refinement through data assimilation. The plan further outlines testing methodologies, including pre-test analyses, test-loop design parameters, and sensor placement strategies that maximize information yield while maintaining mechanistic fidelity. Complementary sections describe in-service inspection (ISI), on-line monitoring (OLM), and structural-health-monitoring (SHM) techniques applicable to compact HX geometries typical of advanced reactors. Collectively, these activities establish the technical foundation for demonstrating 40-60-year equivalent service life of advanced heat exchangers in support of the U.S. Department of Energy’s Advanced Reactor and Integrated Energy Systems programs. The forthcoming phase will execute the defined pre-test analyses, initiate hardware fabrication, and implement the integrated testing campaign to validate the proposed qualification methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Interactive display/graphics systems for remote sensor data analysis

A color-television display system and interactive graphics equipment on-line to an IBM 360/44 computer are used to develop a variety of interactive displays which aid in analyzing remote sensor data. These interactive displays are used to: (1) analyze data from a multispectral scanner; (2) develop automatic pattern recognition systems based on multispectral scanner measurements; and (3) analyze data from non-imaging sensors such as the infrared radiometer and microwave scatterometer.

Eppler, W. G.↗

Automatic microscopy for mitotic cell location.

Advances are reported in the development of an automatic microscope with which to locate hematologic or other cells in mitosis for subsequent chromosome analysis. The system under development is designed to perform the functions of: slide scanning to locate metaphase cells; conversion of images of selected cells into binary form; and on-line computer analysis of the digitized image for significant cytogenetic data. Cell detection criteria are evaluated using a test sample of 100 mitotic cells and 100 artifacts.

Herron, J.↗

Study to design and develop remote manipulator system

Human performance measurement techniques for remote manipulation tasks and remote sensing techniques for manipulators are described for common manipulation tasks, performance is monitored by means of an on-line computer capable of measuring the joint angles of both master and slave arms as a function of time. The computer programs allow measurements of the operator's strategy and physical quantities such as task time and power consumed. The results are printed out after a test run to compare different experimental conditions. For tracking tasks, we describe a method of displaying errors in three dimensions and measuring the end-effector position in three dimensions.

Hill, J. W.↗

Real-time gross actinide monitoring in extreme (10 6 :1) beta-gamma background fluid streams using mini-ATMFDs

Real-time, trace alpha activity monitoring in extreme mixed radiation fields is a well-known challenge in fission product-rich streams containing mixtures of beta-gamma-alpha radiation-emitting isotopes, arising due to the extreme 10 6 :1 ratio of background beta-gamma vs. alpha radiation activity levels. This paper presents results from a novel approach to addressing this challenge, based on Tensioned Metastable Fluid Detector (TMFD) sensing technology. An acoustically driven technique was developed and tested at Purdue University (using dissolved Rn-Po and U-chain alpha emitters), and validated (with dissolved Pu) at Savannah River National Laboratory for real-time monitoring of alpha activity in the 100–10,000 dpm/mL range.

Environmental Monitoring↗