Search NASA⌕ Search

SEARCH · Search NASA

Results for “on-line”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

First on-line commissioning experiments at the St. Benedict facility

Nuclear beta decays provide an excellent probe of fundamental symmetries due to their mediation by the weak interaction. In particular, precise measurements of these decays provide constraints on the unitarity of the Cabbibo-Kobayashi-Maskawa (CKM) quark-mixing matrix. While superallowed pure Fermi decays currently set the most precise limits, the alternative suite of superallowed mixed mirror decays has been ill-studied. These nuclei can provide an important consistency check of calculation and measurement methods employed for the pure Fermi decays, more critically needed now in the wake of a 2.4σ deviation from unitarity of the CKM matrix. In order to remedy the gap in data for mirror decays, the Superallowed Transition Beta-Neutrino Decay Ion Coincidence Trap (St. Benedict) facility is being commissioned at the University of Notre Dame’s Nuclear Science Laboratory (NSL). In this paper, we present first results of the commissioning of the St. Benedict facility on-line at the TwinSol radioactive beam facility. The results of initial commissioning experiments involving the St. Benedict gas catcher, RF carpet, RFQ ion guide and RFQ cooler-buncher will be presented.

beta decay↗

A Novel Optical Instrument for On-Line Measurement of Particle Size Distribution—Application to Clean Coal Technologies

A flow cell is a critical measurement interface for many optical instruments. However, the flows are often sampled under harsh conditions, such as under high pressure and/or high temperature, in the presence of particles, moisture, vapors with high dew points or corrosive gases. Therefore, obtaining a high-optical-quality flow cell that does not perturb the measurement is a significant challenge. To address this challenge, we proposed a new flow cell that employs a unique laminar coaxial flow field (for the purge and sample flows). A test system was built to conduct particle size distribution (PSD) measurements with no sampling bias using a state-of-the-art analyzer (Malvern Panalytical Insitec). The results revealed that the measurement zone is well defined solely by the sample flow, and the optical windows are well protected by the purge flow, with minimal risk of any depositions from the sample flow. Using this flow cell, the Insitec can successfully measure PSD under high pressure and temperature under moist, corrosive conditions without generating any sampling bias. Importantly, we successfully applied this flow cell for on-line PSD measurement for the flue gas of a 100 kWth pressurized oxy-coal combustor operating at 15 bara.

Cheng, Mao (ORCID:0000000213273900)↗

On-line Inductively Coupled Plasma Mass Spectrometry Reveals Material Degradation Dynamics of Au and Cu Catalysts during Electrochemical CO 2 Reduction

A significant challenge in commercializing electrochemical CO 2 reduction (CO 2 R) is achieving catalyst durability. Here, in this study, online inductively coupled mass spectrometry (ICP–MS) was used to investigate catalyst degradation via nanoparticle detachment and/or dissolution into metal ions under CO 2 R operating conditions in 0.1 M KHCO 3 . We developed an experimental framework with ex situ characterization to validate the online ICP–MS method for in situ evaluation of degradation from metal foils. By varying the applied potential and microenvironment (CO 2 vs N 2 -saturated electrolyte), we gained insights into the degradation of Au and Cu foils under CO 2 R and hydrogen evolution reaction (HER) conditions. While both Au and Cu foils were observed to be stable to dissolution in these regimes, degradation via nanoparticle detachment from the foil surface at the femtogram scale was observed as a function of reaction conditions, providing new insights into material degradation mechanisms. When applying potential steps at −0.1 and −1.0 V vs the reversible hydrogen electrode (RHE), Au was found to degrade via nanoparticle detachment under CO 2 R operating conditions more than under HER conditions, while Cu was found to degrade via nanoparticle detachment in similar amounts during both reactions. Au lost ∼1.8× more mass and ∼7.5× more nanoparticles than Cu under CO 2 R operating conditions. This study demonstrates the use of online ICP–MS to gain insight into the degradation of Au and Cu, the importance of studying unconventional degradation mechanisms such as nanoparticle detachment, and that online ICP–MS can be further utilized to gain fundamental understanding of catalyst durability for a variety of reaction systems.

Yan, Katherine [Stanford Univ., CA (United States)↗

Rapid monitoring of fermentations: a feasibility study on biological 2,3-butanediol production

2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be produced by the fermentation of sugars using an engineered strain of Zymomonas mobilis . These fermentations require continuous monitoring and modification of fermentation conditions to maximize 2,3-BDO yields and minimize the production of the undesired coproducts glycerol and acetoin. Because of the time required for sampling and off-line chromatographic measurement of fermentation samples, the ability of fermentation scientists to modify fermentation conditions in a timely manner is limited. The goal of this study was to test if near-infrared spectroscopy (NIRS) along with multivariate statistics could reduce the time needed for this analysis and enable real-time monitoring and control of the fermentation. In this work we developed partial least squares (PLS) calibration models to predict the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol in fermentations via NIRS using two different spectrometers and two different spectroscopy modalities. We first evaluated the feasibility of rapid NIRS monitoring through experiments where we measured the signals from each analyte of interest and built NIRS-based PLS models using spectra from synthetic samples containing uncorrelated concentrations of these analytes. All analytes showed unique spectral signatures, and this initial modeling showed that all analytes could be detected simultaneously. We then began work with samples from laboratory fermentation experiments and tested the feasibility of regression model development across two spectral collection modalities (at-line and on-line) and two instruments: a laboratory-grade instrument and a low-cost instrument with a more limited spectral range. All modalities showed promise in the ability to monitor Z. mobilis fermentations of glucose and xylose to 2,3-BDO. The low-cost instrument displayed a lower signal-to-noise ratio than the laboratory-grade instrument, which led to comparatively lower performance overall, but still provided sufficient accuracy to monitor fermentation trends. While the ease of use of on-line monitoring systems was favored as compared to at-line systems due to the lack of sampling required and potential for automated process control, we observed some decrease in performance due to the additional complexity of the sample matrix. We have demonstrated that NIRS combined with multivariate analysis can be used for at-line and on-line monitoring of the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol during Z. mobilis fermentations. The decrease in signal-to-noise ratio when using a low-cost spectrometer led to greater prediction error than the laboratory-grade spectrometer for at-line monitoring. The on-line monitoring modality showed great promise for real time process control via NIRS.

09 BIOMASS FUELS↗

Fluorescence Signatures of Rare Earth Metals during Precipitation in Various Conditions

Fluorescence spectroscopy is a widely used sensor methodology that analyzes light emitted from a compound or element as it decays from an excited state. This technique is very sensitive and selective, which is ideal to characterize analytes at lower limits of detection. Key example targets of significant industry and research interest include rare earth elements (REEs) such as dysprosium (Dy) and europium (Eu). These are widely used in advanced technologies including semiconductors, electric vehicle motors, lasers, and permanent magnets. Identifying new sources and responsible reutilization of REEs is essential, and new approaches to extract and recycle REEs could be notably enhanced through the integration of on-line sensors. The sensors can support faster process design, informed scale-up, and cost-effective deployment. This study covers the initial exploration of applying fluorescence-based on-line monitoring to REEs within a precipitation process. This study demonstrates the successful scale-up of a fluorescence -based sensing approach, from stationary cuvettes and small-volume microfluidic devices to continuous flow systems operating at the bench scale (10-25mL). This work also provides initial insight into the challenges of signal’s effects and utility within a turbid environment. Using a modular design for monitoring flowing solutions in a flow tube, fluorescence can be characterized for a variety of analytical targets. In this study, detection performance parameters between the cuvette and flow tube system were compared. Additionally, the response of Dy during precipitation by sodium bicarbonate in the two measurement designs was explored. This letter represents a starting point to bridge the gap between traditional fluorescence sensor measurements in a cuvette to future developments that explore the ability to integrate fluorescence sensors into extraction and separation processes at industrially relevant scales.

fluorescence↗

Development of an Attenuated Total Reflectance–Ultraviolet–Visible Probe for the Online Monitoring of Dark Solutions

Optical spectroscopy is a valuable tool for on-line monitoring of a variety of processes. Ultraviolet-visible (UV-vis) spectroscopy in particular, can monitor the concentration of analytes as well as identify speciation and oxidation state. However, it can be difficult to impossible to employ UV-vis based sensors on chemical systems that are very dark (i.e., high optical density) as exceedingly short pathlengths are required (for transmission approaches) or effective means of backscattering are needed (for reflectance approaches). Examples of processes that would benefit significantly from the use of optical sensors and encounter these challenges include used nuclear fuel recycling and molten salts with high concentrations of dissolved uranium. Utilizing an attenuated total reflectance (ATR) UV-vis approach can overcome these challenges and allow for the measurement of solutions orders of magnitude more concentrated than transmission UV-vis. However, determining ideal sensor specifications for varied processes can be time consuming and expensive. Here, in this study, we evaluate the ability for a novel ATR-UV-vis probe to measure very concentrated solutions of Co(II) and Ni(II) nitrate as well as organic dyes (methylene blue, acid red 1, and crystal violet). This sensor design provides a modular method for exploring possible “pathlengths” by altering the exposed ATR fiber length. Also studied were approaches to loading and measuring the sensor cell. These results are compared to a traditional 1 cm cuvette measured by transmission UV-vis. It was found that the ATR-UV-vis probe was capable of measuring solutions 600 times more concentrated than the 1 cm cuvette. Advanced data analysis in the form of multivariate curve resolution (MCR) was used to analyze the speciation of methylene blue over a large concentration range. The application of this novel ATR-UV-vis probe to the interrogation of dark solutions is a promising avenue for use in on-line monitoring of nuclear processes.

47 OTHER INSTRUMENTATION↗

Exploring Fission–Fusion Synergies to Accelerate Compatibility Understanding

To address the significant commercial interest in fusion energy, it will be necessary to accelerate the compatibility research associated with liquid breeders including Li, eutectic Pb–Li and LiF-BeF 2 (FLiBe) molten salt. Particularly for FLiBe, compatibility understanding is limited especially for fusion relevant materials such as reduced activation ferritic-martensitic steels, SiC and V alloys. The historical knowledge associated with molten salt reactors (MSRs) and recent work to commercialize MSRs can benefit fusion research. Recent experimental and modeling work has improved understanding and this knowledge can be applied to fusion relevant materials. For liquid metals (LMs), the comparisons to Li and Pb–Li are less direct but nevertheless can help guide the pathway toward commercialization. For Pb–Li, Al-rich coatings have been shown to inhibit dissolution and potentially increase operating temperatures. For commercialization, the experience with sensors and on-line cleanup can help guide future developments. Thus, it is worth considering the potential for fission-related research with LMs and molten salts to help accelerate fusion research.

36 MATERIALS SCIENCE↗

Excited states in semi-magic 82 Ge populated in the βn-decay of 83 Ga

For this work, the βn and β-decay of the neutron-rich 83 Ga isotopes produced in proton-induced fission of 238 U were studied at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory using on-line mass separation and the hybrid-3Hen neutron-γ detector array. Excited states in semi-magic 82 Ge populated in βn decay of 83 Ga were identified using neutron-γ coincidences. The measured relative population of excited states in 82 Ge is compared with a βn emission model, where the neutron emission model combines the strength distribution obtained from the shell-model calculations with the statistical Hauser-Feshbach model.

3HEN↗

Multimodal In Situ Characterization Uncovers Unexpected Stability of a Cobalt Electrocatalyst for Acidic Sustainable Energy Technologies

An accelerated development of durable and affordable sustainable energy technologies is often hindered by a limited understanding of how non-precious materials within these systems degrade. In acidic proton exchange membrane fuel cells and water electrolyzers, metallic cobalt (Co) is considered an unstable component that is often combined with precious metals or other stabilizers. To understand the mechanisms behind Co instability, we employ an experimental platform that quantifies dissolution with on-line inductively coupled plasma mass spectrometry and product formation with electrochemical mass spectrometry during electrochemical testing, along with ex- situ characterization. Under varied conditions (electrocatalysis, time, gas-type saturation, and ion concentration), windows of Co stability are observed that are different than predicted with classical chemical thermodynamics, suggesting new stabilization and degradation mechanisms than previously understood. Notably, Co is active for the hydrogen evolution reaction (HER), with prolonged stability that is ~300 mV different than thermodynamically projected. Additionally, in an oxygenated environment, Co concurrently performs the HER and oxygen reduction reaction (ORR) yet undergoes different morphology changes and dissolution mechanisms. Interestingly, in the absence of electrocatalysis, there is a 22x decrease in dissolution in an oxygen-free environment, proposing a route to decrease Co losses during device shutdown protocols. Lastly, under more extreme operating conditions, Co becomes stable after a substantial amount of dissolution, suggesting that high concentrations of Co 2+ ions in the microenvironment induce the formation of a stable CoHO 2 surface. Altogether, these results can be leveraged to improve the design and development of more robust and cost-effective sustainable energy technologies, as well as promote strategic strategies for prolonged material utilization.

Dissolution↗

Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗

Customized Bayesian optimization for efficient beam tuning at the facility for rare isotope beams

Bayesian optimization (BO) has recently emerged as a powerful approach for on-line beam tuning, and it is rapidly gaining adoption across accelerator facilities due to its flexibility and efficiency in handling complex optimization tasks. At the Facility for Rare Isotope Beams, rapid and reliable tuning is essential to support the delivery of diverse ion species. To improve the practicality of BO in this setting, we implemented several enhancements, including scalarized composite objective construction for multicriteria optimization, asynchronous evaluation for better resource utilization, prior-mean-assisted optimization to accelerate convergence, and a local search strategy for rapid completion of the task. We present the details of these methods, discuss challenges-encountered, and share our experience applying them to specific beam-tuning tasks.

Accelerators & storage rings↗

Binding energies, charge radii, spins, and moments: Odd-odd Ag isotopes and discovery of a new isomer

We report on the masses and hyperfine structure of ground and isomeric states in 114,116,118,120 Ag isotopes, measured with the phase-imaging ion-cyclotron-resonance technique (PI-ICR) with the JYFLTRAP mass spectrometer and the collinear laser spectroscopy beamline at the Ion Guide Isotope Separator On-Line facility, Jyväskylä, Finland. We measured the masses and excitation energies, electromagnetic moments, and charge radii, and firmly established the nuclear spins of the long-lived states. A new isomer was discovered in 118 Ag and the half-lives of 118 Ag long-lived states were reevaluated. We unambiguously pinned down the level ordering of all long-lived states, placing the inversion of the 𝐼 = 0 − and 𝐼 = 4 + states at 𝐴 = 118 (𝑁 = 71). As a result, we compared the electromagnetic moments of each state to empirical single-particle moments to identify the dominant configuration where possible.

90 ≤ A ≤ 149↗

Adaptive Online Model Update Algorithm for Predictive Control in Networked Systems

In this article, we introduce an adaptive on-line model update algorithm designed for predictive control applications in networked systems, particularly focusing on power distribution systems. Unlike traditional methods that depend on historical data for offline model identification, our approach utilizes real-time data for continuous model updates. This method integrates seamlessly with existing online control and optimization algorithms and provides timely updates in response to real-time changes. This methodology offers significant advantages, including a reduction in the communication network bandwidth requirements by minimizing the data exchanged at each iteration and enabling the model to adapt after disturbances. Furthermore, our algorithm is tailored for non-linear convex models, enhancing its applicability to practical scenarios. The efficacy of the proposed method is validated through a numerical study, demonstrating improved control performance using a synthetic IEEE test case.

data-driven model predictive control↗

Closing the loop: model-predictive control for a closed-circuit reverse osmosis system

This article presents a model-predictive controller (MPC) for the maximization of the energy efficiency of a closed-circuit desalination reverse osmosis (CCRO) system. CCRO is a process for producing drinking water that is based on a cyclic operation with the following two phases: (a) filtration and (b) drain. In this article, we test model predictive control for optimal control of this process. The most important features of our approach are as follows: (a) the selection of a model structure that enables reliable forecasts of the filtration phase (up to 3 h), (b) an on-line model calibration strategy that ensures model forecast reliability, and (c) the satisfaction of equipment safety and operational constraints on the selected setpoints. We challenge this through deliberate introduction of changes in the unmeasured feed concentration and the applied constraints. Our results indicate that frequent model parameter updates are critical to maintain model reliability for MPC purposes. In addition, we illustrate that parameter identifiability is not guaranteed and that deliberate variation in flow rates is necessary even though the process never operates in steady state. Finally, MPC can compute flow rate setpoints that maximize the energy efficiency of the CCRO process while satisfying the applicable equipment and safety constraints.

closed-circuit reverse osmosis↗

OpenCSP Step-by-Step: Getting Started Guide for Windows (V.1.0)

This document provides a step-by-step tutorial on how to set up OpenCSP for both users and developers. It is meant to support novice users and does not require software engineering experience. It is a detailed extension of the OpenCSP getting started on-line documentation, found here: https://opencsp.readthedocs.io/en/main/contributing.html#getting-started. For an overview of OpenCSP overall, see the OpenCSP website: https://opencsp.sandia.gov. For details on OpenCSP components and algorithm, see the references.

97 MATHEMATICS AND COMPUTING↗

Preliminary Plan to Inform Testing of a Heat Exchanger Test Article

This report presents a preliminary plan to guide the qualification testing of advanced heat exchanger (HX) components for nuclear-to-industrial heat transfer applications. The objective is to establish a defensible, physics-based methodology that integrates computational modeling, targeted experimentation, and in-service inspection considerations to demonstrate component performance and reliability under representative reactor conditions. The analysis identifies Sodium-cooled Fast Reactor (SFR) and High-Temperature Gas-cooled Reactor (HTGR) systems as reference configurations in terms of temperature, pressure, and chemical environment. Within these operating envelopes, dominant degradation mechanisms— including creep–fatigue interaction, flow-induced vibration, corrosion, and diffusion-bond deterioration—were evaluated to define test requirements. A comprehensive computationalexperimental framework is proposed to support life prediction and qualification activities. The framework couples high-fidelity structural-mechanics, thermal-hydraulic, and fluid-structure interaction models with accelerated degradation testing to produce a traceable linkage between microstructural evolution, mechanical performance, and remaining useful life (RUL). The approach adheres to established Verification, Validation, and Uncertainty Quantification (VVUQ) standards (ASME V&V 10/20; NUREG-2152) and incorporates a digital-twin architecture for continuous model refinement through data assimilation. The plan further outlines testing methodologies, including pre-test analyses, test-loop design parameters, and sensor placement strategies that maximize information yield while maintaining mechanistic fidelity. Complementary sections describe in-service inspection (ISI), on-line monitoring (OLM), and structural-health-monitoring (SHM) techniques applicable to compact HX geometries typical of advanced reactors. Collectively, these activities establish the technical foundation for demonstrating 40-60-year equivalent service life of advanced heat exchangers in support of the U.S. Department of Energy’s Advanced Reactor and Integrated Energy Systems programs. The forthcoming phase will execute the defined pre-test analyses, initiate hardware fabrication, and implement the integrated testing campaign to validate the proposed qualification methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

New U.S. Data Tools are Playing a Crucial Role in Decarbonizing Buildings at Speed, Scale, and Low Cost

Preparing buildings for retrofits traditionally requires expensive on-site audits or timeintensive simulation models. As a result, the majority of buildings fail to pursue cost-saving retrofits. To address these barriers, the U.S. Department of Energy (DOE) has introduced the Building Efficiency Targeting Tool for Energy Retrofits (BETTER)-a new, free, on-line tool that utilizes a data-driven analytical engine and user-friendly web interface to automatically analyze a building's monthly energy usage in response to weather conditions. The tool benchmarks a building's electric and fossil energy usage against peers; estimates energy, cost, and emissions reductions at the building and portfolio levels; recommends energy efficiency measures; and prioritizes buildings for net-zero energy retrofits. Thanks to interoperability with the DOE's Standard Energy Efficiency Data (SEED) platform, BETTER is supporting U.S. jurisdictions to prepare buildings for retrofit at speed, scale, and low cost to comply with energy policies. This paper discusses the use of BETTER and SEED by one of the branches of the California state government to streamline a retrofit program across 455 public non-residential buildings to align with state goals to reduce greenhouse gas emissions. It describes the organization's challenge to reduce energy consumption across a geographically diverse, aging portfolio; explores how BETTER and SEED improved workflow efficiency; presents preliminary results, including avoiding audit costs of $3.28 million and developing the groundwork for retrofit projects estimated to prevent emission of 2,271 t CO2e annually; and provides guidance for other jurisdictions seeking similar results.

BETTER↗